• 제목/요약/키워드: Internal and External Evaluation

검색결과 438건 처리시간 0.025초

타이어와 차량 쏠림 I-시험결과 (Tire and Vehicle Pull I-Experimental Results)

  • 이정환;이주완
    • 한국자동차공학회논문집
    • /
    • 제8권4호
    • /
    • pp.194-201
    • /
    • 2000
  • It is called vehicle pull when a vehicle drifts in the lateral direction under the straight-ahead motion with no steering or external input. Recently vehicle pull draws attention as one of the critical evaluation items from the customers on the vehicle quality. It is generally recognized that the vehicle pull is complex phenomena due to internal and external factors. In this paper the relations between vehicle pull and ire were investigated through close survey on the road test results from the final inspection of car manufactures. Through this investigation the factors are identified which play an important role in causing vehicle pull problem.

  • PDF

백시트 종류에 따른 태양전지 모듈의 방열 특성 평가 (Evaluation of Heat Transfer Characteristics of PV Module with Different Backsheet)

  • 배수현;오원욱;강윤묵;이해석;김동환
    • Current Photovoltaic Research
    • /
    • 제6권2호
    • /
    • pp.39-42
    • /
    • 2018
  • When the PV module is illuminated in a high temperature region, solar cells are also exposed to the high temperature external environment. The operating temperature of the solar cell inside the module is increased, which causes the power drops. Various efforts have been made to reduce the operating temperature and compensate the power of solar cells according to the outdoor temperature such as installing of a cooling system. Researches have been also reported to lower the operating temperature of solar cells by improving the heat dissipation properties of the backsheet. In this study, we conducted a test to measure the internal temperature of each module components and the external temperature when the light was irradiated according to the surrounding temperature. Backsheets with different thermal conductivities were compared in the test. Finally, in order to explain the temperature difference between the solar cell and the outside of the module, we proposed an evaluation method of the heat transfer characteristics of photovoltaic modules with different backsheet.

Comparative clinical and radiologic evaluation between patients undergoing standard reversed shoulder arthroplasty or bony increased offset

  • Tiago Amorim-Barbosa;Ana Ribau;Helder Fonte;Luis Henrique Barros;Rui Claro
    • Clinics in Shoulder and Elbow
    • /
    • 제26권1호
    • /
    • pp.3-9
    • /
    • 2023
  • Background: Modifications of the medialized design of Grammont-type reverse shoulder arthroplasty (RSA) using a bony increased offset (BIO-RSA) has shown better clinical results and fewer complications. The aim of this study is to compare the clinical results, complications, and radiological outcomes between patients undergoing standard RSA and BIO-RSA. Methods: A retrospective review was performed of 42 RSA procedures (22 standard RSA and 20 BIO-RSA). With a minimum of 1 year of follow-up, range of motion (ROM), Constant shoulder score (CSS), visual analog scale (VAS), and subjective shoulder score (SSS) were compared. Radiographs and computed tomography (CT) scan were examined for scapular notching, glenoid and humeral fixation, and graft healing. Results: At a mean follow-up of 27.6 months (range, 12-48 months), a significant difference was found for active-internal rotation (P=0.038) and for passive-external rotation (P=0.013), with better results in BIO-RSA. No other differences were found in ROM, CSS (P=0.884), VAS score, and SSS. Graft healing and viability were verified in all patients with CT scan (n=34). The notching rate was 28% in the standard RSA group and 33% in the BIO-RSA group, but the standard RSA had more severe notching (grade 2) than BIO-RSA (P=0.039). No other significative differences were found in glenoid and humeral fixation. Conclusions: Bone-graft lateralization is associated with better internal and external rotation and with less severe scapular notching compared to the standard RSA. Integration of the bone graft occurs effectively, with no relevant changes observed on radiographic evaluation. Level of evidence: III.

급성 견봉쇄골관절 탈구에서 변형된 Phemister 술식과 C-C sling 술식의 결과 비교 (The Surgical Treatment of Acute Acromioclavicular Joint Dislocation Using C-C Sling Method and Modified Phemister Operation)

  • 전철홍;심대무;정을오;이종명;이병창;김정우
    • Clinics in Shoulder and Elbow
    • /
    • 제9권1호
    • /
    • pp.60-67
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the method of using coraco-clavicular (C-C) sling with modified Phemister operation by postoperative clinical results, radiologic analysis and complications. Materials and Methods: 33 patients of acromioclavicular joint dislocation were included in this study. Thirteen patients were treated with simple C-C sling method and twenty patients were treated with modified Phemister operation. The assesment of clinical and radiological evaluation were performed and the final results were examined by using the Weitzman's classification. Results: In the final result of C-C sling method group, forward elevation $161^{\circ}$, external rotation $70^{\circ}$, internal rotation T8 level, Visual Analogue Scale (VAS) 83.3 points were checked. In modified Phemister operation group, forward elevation $155^{\circ}$, external rotation $67^{\circ}$, internal rotation T6 level, VAS 83.8 points were checked. In coracoclavicular distance of C-C sling method group, pre-operation 12.82 mm and last follow up 8.37 mm were checked. In modified Phemister operation group, pre-operation 12.8 mm and last follow up 7.7 mm were checked. In functional evaluation by the Weitzman criteria, C-C sling group had excellent 8, good 1, fair 1 and modified Phemister group had excellent 13, good 4, fair 3. Conclusion: C-C sling method would be the better than the Modified Phemister operation because of short operation time and smaller skin incision.

주상복합의 실외기 형태에 따른 냉방시스템 성능 평가 (The performance evaluation of outdoor unit cooling system in a residential apartment complex)

  • 경서경;김윤진;임정희;김병선
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 추계학술발표대회 논문집
    • /
    • pp.263-268
    • /
    • 2008
  • In a residential complex case, the efficiency of land use are maximized, but a variation of external condition such as load in-equality, the increase in wind velocity and solar radiation by a height causes increasing energy in a building. Besides, because of increasing window size for a lighting and a view, it comes heating load in winter and cooling load in summer. A choice of cooling-system is important for this reason. Recently an internal high-rise residential complex installs an air-cooling system and operates individual heating. However, this study applies water-cooling used one public cooling-tower instead of an air-cooling system, also with an efficiency test of an air and a water-cooling system, consider an internal applicability.

  • PDF

탑재비행시험용 무선 점검장치 개발에 대한 연구 (A Study on Development of Wireless Check-up Device for Captive Flight Test)

  • 류상규;주정현;고명준
    • 한국군사과학기술학회지
    • /
    • 제22권4호
    • /
    • pp.501-508
    • /
    • 2019
  • In this paper, a study on a wireless check-up method of test equipment for captive flight test(CFT) was conducted. For CFT, test equipment is mounted on a POD, and check-up is carried on the test equipment's. For check-up the POD wirelessly, battery, power distribution unit, wireless communication devices were designed within the POD, and a check-up device is designed outside of the POD. Once the external check-up device sends a 'start signal' to the POD, it performs the overall check-up procedures and transmits the 'end signal' to the external check-up device. Detailed check-up results are stored in an internal storage device, and are possible to read from external check-up device if necessary, thereby improving the reliability of the wireless check-up. By implementing and applying these wireless check-up system, the reliability of the check-up was enhanced by dynamical and movable check-up, and safety is guaranteed as the check-up was carried without access to the aircraft.

Short-term Comparison of Supervised Rehabilitation and Home-based Rehabilitation for Earlier Recovery of Shoulder Motion, Pain, and Function after Rotator Cuff Repair

  • Song, Si-Jung;Jeong, Tae-Ho;Moon, Jung-Wha;Park, Han-Vit;Lee, Si Yung;Koh, Kyoung-Hwan
    • Clinics in Shoulder and Elbow
    • /
    • 제21권1호
    • /
    • pp.15-21
    • /
    • 2018
  • Background: This study was undertaken to compare the outcome of supervised and home exercises with respect to range of motion (ROM), pain, and Single Assessment Numeric Evaluation (SANE). We further correlated the ROM recovery and pain reduction as well. Methods: The study included 49 patients who underwent arthroscopic rotator cuff repair. Rehabilitation was initiated after 4 weeks of immobilization. A total of 29 patients performed supervised exercise 3 times a week. Standardized education and brochures for review were provided to the remaining 20 patients who insisted on home rehabilitation. Statistical analysis was performed for comparing pain Numerical Rating Scale (NRS), SANE, and ROM. In addition, we also evaluated the correlation between pain and ROM. Results: Comparison of the two groups revealed no significant differences in forward flexion, internal rotation, abduction, and pain NRS. However, SANE at the 9th week (63.8 vs. 55.0, p=0.038) and improvement of external rotation from the 5th to the 9th week (17.6 vs. 9.3, p=0.018) were significantly higher in the supervised exercise group as compared to the home exercise group. Correlation of pain NRS with forward flexion, external rotation, internal rotation and abduction were statistically not significant (correlation coefficient=0.032 [p=0.828], -0.255 [p=0.077], 0.068 [p=0.642], and -0.188 [p=0.196], respectively). Conclusions: The supervised rehabilitation after arthroscopic rotator cuff repair showed better improvement in external rotation and higher SANE score after 4 weeks of rehabilitation exercise. However, no statistically significant correlation was observed between the recovery of ROM and short-term pain relief.

자긴가공된 두꺼운 실린더의 피로균열 전파수명평가 (Fatigue crack propagation life evaluation of an autofrettaged thick-walled cylinder)

  • 이송인;김진용;정세희;고승기
    • 대한기계학회논문집A
    • /
    • 제22권2호
    • /
    • pp.321-329
    • /
    • 1998
  • To ensure the structural integrity of the autofrettaged thick-walled cylinder subjected to cyclic internal pressure loading, the fatigue crack propagation life of the cylinder was evaluated. Stress intensity factors of the external cracked cylinder due to internal pressure and autofrettage loadings were calculated using the finite element method. The fatigue crack propagation lives of the cylinder based on the fracture mechanics concepts were predicted and compared to the experimental fatigue lives evaluated from the C-shaped simulation specimens. There were good correlations between the predicted and experimental fatigue lives within a factor of 3 for the single and double grooved C-shaped simulation specimens. Predicted fatigue crack propagation lives of the double grooved cylinders were about 1.5-5 times longer than those of the single grooved cylinders depending on the levels of autofrettage.

공동주택 습식 진공 외단열시스템 성능 평가 (Performance Evaluation of Adhesively Fixed External Insulation and Finish System Using Vacuum Insulation Panels for Apartment Buildings)

  • 박시현;임재한;송승영
    • KIEAE Journal
    • /
    • 제13권6호
    • /
    • pp.45-53
    • /
    • 2013
  • For the target goal of Zero-energy House construction in 2025, the government announced that the insulation regulations will be continuously enhanced. It has been predicted that high-performance insulation materials, such as vacuum insulation panel (VIP), should be used to decrease the thickness of outer walls. The aim of this study was to evaluate the performance of adhesively fixed external insulation and finish system (EIFS) with VIP. The energy performance of a base model with conventional internal insulation system and three alternatives of EIFS with VIP were analyzed by three-dimensional heat transfer simulation. Construction cost and convenience of each alternative were also evaluated and compared. As results, effective alternatives in terms of each performance as well as overall performance considering the weighting factors of each performance were suggested.

부하의 낮은 업적에 대한 상사의 반응에 관한 연구 (Empirical Study on the Supervisor's Responses to the Subordinate's Poor Performance)

  • 홍용기
    • 경영과정보연구
    • /
    • 제8권
    • /
    • pp.25-43
    • /
    • 2002
  • Performance evaluation continues to receive attention today as it has for the past few decades. The problem addressed in this paper concerns the relationship between supervisor's causal attributions and their subsequent responses behavior. Previous study in personnel and other disciplines has indicated the importance of causal attributions in the interpretation of poor performance. However, most study has focused on antecedents of attributions than supervisor's responses to the subordinate's poor performance. The objective of this study was to investigate the effects of supervisor's causal attributions and subordinate's responses to a subordinate's poor performance. Specifically, using in the public sector context, the study examined the effects to two dimensions of causal attributions: locus of causality and stability, as well as on the punitiveness of supervisors's responses. The result supported that when the subordinate is internal causes for the performance failure, supervisor's responses were more punitive. Consistent with previous studies, internal attributions were found to result in more punitive behavior than external attribution. In addition, attributions to effort and luck were found to result in more punitive behavior than attributions to ability and task difficulty. Thus, the first hypothesis and second hypothesis supported. These result suggest the importance of appropriately for performance evaluation.

  • PDF