• Title/Summary/Keyword: Internal Table

Search Result 208, Processing Time 0.036 seconds

Sensitivity Analyses of Influencing Factors on Stability in Soil Cut Slope (토사 절토사면 안정성 영향인자의 민감도 분석)

  • Yoo, Nam-Jae;Park, Byung-Soo;Jun, Sang-Hyun;Cho, Han-Ki
    • Journal of Industrial Technology
    • /
    • v.26 no.B
    • /
    • pp.73-81
    • /
    • 2006
  • A sensitivity analysis about effects of influencing factors on the stability of Soil cut slope was performed. Slope stability analyses were carried out under dry, rainy and seismic conditions. Dominant factors controlling the slope stability were chosen such as cohesion and internal friction angle, unit weight of soil, water table and seismic horizontal coefficient used for the slope stability during earthquake. Parametric stability analysis with those factors was performed for sensitivity analysis. As results of analyzing the sensitivity of factors under dry and rainy conditions, effects of cohesion, internal friction angle and unit weight of soil on the stability of slope are more critical in the dry condition than in the rainy condition. Cohesion and internal friction angle are more dominant factors influencing the slope stability irrespective of dry or rainy conditions than unit weight of soil and the horizontal seismic coefficient. The unit weight and the horizontal seismic coefficient affects crucially the stability according to conditions of slope formation and dry or rainy seasons. For the effect of horizontal seismic coefficient on stability of slope, safety factor of slope is not affected significantly by dry or rainy conditions. However, increase of the horizontal seismic coefficient under the rainy condition floes reduce the safety factor significantly rather than the dry condition. Therefore, it is needed that the location of the water table is assigned appropriately to satisfy the required safety factor of stability in the case of checking slope stability for the rainy and seismic conditions.

  • PDF

Vibration characteristic of rubber isolation plate-shell integrated concrete liquid-storage structure

  • Cheng, Xuansheng;Qi, Lei;Zhang, Shanglong;Mu, Yiting;Xia, Lingyu
    • Structural Engineering and Mechanics
    • /
    • v.81 no.6
    • /
    • pp.691-703
    • /
    • 2022
  • To obtain the seismic response of lead-cored rubber, shape memory alloy (SMA)-rubber isolation Plate-shell Integrated Concrete Liquid-Storage Structure (PSICLSS), based on a PSICLSS in a water treatment plant, built a scale experimental model, and a shaking table test was conducted. Discussed the seismic responses of rubber isolation, SMA-rubber isolation PSICLSS. Combined with numerical model analysis, the vibration characteristics of rubber isolation PSICLSS are studied. The results showed that the acceleration, liquid sloshing height, hydrodynamic pressure of rubber and SMA-rubber isolation PSICLSS are amplified when the frequency of seismic excitation is close to the main frequency of the isolation PSICLSS. The earthquake causes a significant leakage of liquid, at the same time, the external liquid sloshing height is significantly higher than internal liquid sloshing height. Numerical analysis showed that the low-frequency acceleration excitation causes a more significant dynamic response of PSICLSS. The sinusoidal excitation with first-order sloshing frequency of internal liquid causes a more significant sloshing height of the internal liquid, but has little effect on the structural principal stresses. The sinusoidal excitation with first-order sloshing frequency of external liquid causes the most enormous structural principal stress, and a more significant external liquid sloshing height. In particular, the principal stress of PSICLSSS with long isolation period will be significantly enlarged. Therefore, the stiffness of the isolation layer should be properly adjusted in the design of rubber and SMA-rubber isolation PSICLSS.

Effect of Platelet Activation on Pulmonary Hypertension in Chronic Obstructive Pulmonary Diseases (만성폐쇄성폐질환에서 혈소판 활성도가 폐동맥 고혈압에 미치는 영향)

  • Kim, Hyung-Jung;Nam, Moon-Suk;Kwon, Hyuck-Moon;Ahn, Chul-Min;Kim, Sung-Kyu;Lee, Won-Young;Song, Kyung-Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.40 no.2
    • /
    • pp.147-152
    • /
    • 1993
  • Background: There is evidence that platelet is activated in chronic obstructive pulmonary disease and activated platelet with injured endothelium contribute to the pathogenesis of pulmonary hypertension, prognostic factor of chronic obstructive pulmonary disease. So, we have investigated platelet function further in chronic obstructive pulmonary disease and effect of platelet activation on pulmonary hypertension. Method: We studied platelet aggregation ratio and alpha-granule products such as platelet factor 4(PF4) and beta-thromboglobulin (${\beta}$-TG) in control subjects and COPD without and with pulmonary hypertension subjects. Result: 1) The platelet aggregation ratio (PAR) was $0.99{\pm}0.04$ in control subjects, $0.98{\pm}0.05$ in COPD without pulmonary hypertension subjects and $0.89{\pm}0.08$ in COPD with pulmonary hypertension subjects. The platelet aggregation ratio of COPD subjects was tend to decrease than that of control subjects and the ratio of COPD with pulmonary hypertension subjects was significantly lower than that of control subjects. 2) The platelet factor 4 (PF4, IU/ml) was $4.7{\pm}1.2$ in control subjects, $18.6{\pm}4.9$ in COPD without pulmonary hypertension subjects and $57.2{\pm}12.7$ in COPD with pulmonary hypertension subjects. The level of COPD subjects was significantly higher than that of control subjects and the level of COPD with pulmonary hypertension subjects was significantly higher than that of COPD without pulmonary hypertension subjects. 3) The beta-thromboglobulin (${\beta}$-TG, IU/ml) was $34.4{\pm}5.8$ in control subjects, $80.4{\pm}18.1$ in COPD without pulmonary hypertension subjects and $93.0{\pm}14.0$ in COPD with pulmonary hypertension subjects. The level of COPD subjects was significantly higher than that of conrtrol subjects and the level of COPD with pulmonary hypertension subjects was tend to increase than that of COPD without pulmonary hypertension subjects. 4) There was no correlation between the clinical parameters and PAR, PF4 and ${\beta}$-TG but there was significant correlation among PAR, PF4 and ${\beta}$-TG. Conclusion: The platelet is activated in chronic obstructive pulmonary disease and the platelet of COPD with pulmonary hypertension is tend to be activated more than that of COPD without pulmonary hypertension. So, activated platelet may involve in the pathogenesis and maintenance of pulmonary hypertension in COPD subjects and modulation of platelet activity that might reduce pulmonary hypertension needs to be determined.

  • PDF

Dynamic Friction Behavior of Interfaces Between Dense Dry Granular Soils and Construction Material(Concrete) (조밀한 건조조립토와 건설재료(콘크리트) 사이의 동마찰계수)

  • 김대상
    • Journal of the Korean Geotechnical Society
    • /
    • v.17 no.6
    • /
    • pp.207-213
    • /
    • 2001
  • Shaking table tests to investigate the dynamic friction behavior of interfaces between dense dry granular soils and construction material(concrete) were performed and the results are reported. The results show the variation of dynamic interface friction coefficients between dense dry granular soils and construction material was small in the sliding velocity range employed in this study. It was also observed that dynamic interface friction coefficients decreased as mean grain sizes of granular soils increased. These coefficients were compared with the friction coefficients obtained from the peak internal friction angles of the same granular soils by plane strain compression tests.

  • PDF

A study on residual stress distribution in surface grinding (평면연삭에서의 잔류응력 분포에 관한 연구)

  • 김경년;정재천;김기선
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.13 no.6
    • /
    • pp.109-118
    • /
    • 1991
  • In this study, it is intended to investigate the effect of the grinding conditions such as table feed, down feed, cross feed of residual stress distribution. And this distribution is investigated upon the grinding direction and the its orthogonal direction at ground layers. The material is used carbon steel (SM20C) which usually used to motor axis. And in order to be considered as Bernoulli-Euler beam, the dimension of the specimen is appropriately designed. According as corroiding the ground surface, the residual stress layers are removed and strain which occured on account of unbalance of internal stress is detected by rosette-gate. Through A/D converter and computer, these values are saved and evaluated residual stress by stress-strain relation formula. Finally, these results are diagrammatized with Auto Cad. The results obtained are as follows. As the depth from the ground surface increases in grinding direction and its orthogonal direction, tensile residual stress exists in the surface, and subsequently it becomes compressive residual stress as it goes downward. As the table feed, the cross feed and the down feed increase, maximum residual stress is transformed form the tensile to the compressive.

  • PDF

Performance Improvement of Asynchronous Mass Memory Module Using Error Correction Code (에러 보정 코드를 이용한 비동기용 대용량 메모리 모듈의 성능 향상)

  • Ahn, Jae Hyun;Yang, Oh;Yeon, Jun Sang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.3
    • /
    • pp.112-117
    • /
    • 2020
  • NAND flash memory is a non-volatile memory that retains stored data even without power supply. Internal memory used as a data storage device and solid-state drive (SSD) is used in portable devices such as smartphones and digital cameras. However, NAND flash memory carries the risk of electric shock, which can cause errors during read/write operations, so use error correction codes to ensure reliability. It efficiently recovers bad block information, which is a defect in NAND flash memory. BBT (Bad Block Table) is configured to manage data to increase stability, and as a result of experimenting with the error correction code algorithm, the bit error rate per page unit of 4Mbytes memory was on average 0ppm, and 100ppm without error correction code. Through the error correction code algorithm, data stability and reliability can be improved.

A Study on Table Top Display for Cooperation (협업을 위한 Table Top Display 연구)

  • Kim, Hyung-Kwan;Lee, Yang-Weon;Lee, Chil-Woo
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2008.05a
    • /
    • pp.163-165
    • /
    • 2008
  • 본 논문은 공간적인 제약을 벗어난 협업을 위하여 사용자가 서로의 모습을 확인할 수 있고, 직접적인 터치에 공간적인 터치(손 형상 및 제스처 인식)를 통하여 보다 자유롭고 직관적인 시스템 제어를 추구 하는 테이블 탑 디스플레이를 제안한다. 테이블 탑 디스플레이는 FTIR(Frustrated Total Internal Reflection : 내부 전반사 장애 현상) 방식이 아닌 TouchLight방식과 HoloWall방식을 조합하여 손 형상 및 제스처 인식을 할 수 있도록 설계하였다.

Reduction of Radiation Dose to Eye Lens in Cerebral 3D Rotational Angiography Using Head Off-Centering by Table Height Adjustment: A Prospective Study

  • Jae-Chan Ryu;Jong-Tae Yoon;Byung Jun Kim;Mi Hyeon Kim;Eun Ji Moon;Pae Sun Suh;Yun Hwa Roh;Hye Hyeon Moon;Boseong Kwon;Deok Hee Lee;Yunsun Song
    • Korean Journal of Radiology
    • /
    • v.24 no.7
    • /
    • pp.681-689
    • /
    • 2023
  • Objective: Three-dimensional rotational angiography (3D-RA) is increasingly used for the evaluation of intracranial aneurysms (IAs); however, radiation exposure to the lens is a concern. We investigated the effect of head off-centering by adjusting table height on the lens dose during 3D-RA and its feasibility in patient examination. Materials and Methods: The effect of head off-centering during 3D-RA on the lens radiation dose at various table heights was investigated using a RANDO head phantom (Alderson Research Labs). We prospectively enrolled 20 patients (58.0 ± 9.4 years) with IAs who were scheduled to undergo bilateral 3D-RA. In all patients' 3D-RA, the lens dose-reduction protocol involving elevation of the examination table was applied to one internal carotid artery, and the conventional protocol was applied to the other. The lens dose was measured using photoluminescent glass dosimeters (GD-352M, AGC Techno Glass Co., LTD), and radiation dose metrics were compared between the two protocols. Image quality was quantitatively analyzed using source images for image noise, signal-to-noise ratio, and contrast-to-noise ratio. Additionally, three reviewers qualitatively assessed the image quality using a five-point Likert scale. Results: The phantom study showed that the lens dose was reduced by an average of 38% per 1 cm increase in table height. In the patient study, the dose-reduction protocol (elevating the table height by an average of 2.3 cm) led to an 83% reduction in the median dose from 4.65 mGy to 0.79 mGy (P < 0.001). There were no significant differences between dose-reduction and conventional protocols in the kerma area product (7.34 vs. 7.40 Gy·cm2, P = 0.892), air kerma (75.7 vs. 75.1 mGy, P = 0.872), and image quality. Conclusion: The lens radiation dose was significantly affected by table height adjustment during 3D-RA. Intentional head off-centering by elevation of the table is a simple and effective way to reduce the lens dose in clinical practice.

A Study on Building Internal Tables in Christianity of the 5th Edition of Korean Decimal Classification (기독교 분야 내부보조표 설정에 관한 연구 - 한국십진분류법 제5판을 중심으로 -)

  • Jeong, Yu Na;Chung, Yeon-Kyoung
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.24 no.3
    • /
    • pp.29-51
    • /
    • 2013
  • The purpose of this study is to develop internal tables in Christian religion in the 5th edition of Korean Decimal Classification. The scope of the Christianity, its structure of various classification schemes, and the concepts of internal tables were analyzed. The contents of several textbooks were analyzed for the scope of the discipline and the classification schemes and internal tables of DDC, UDC, NDC, LCC, Classification of the Library of Union Theological Seminary and the Classification of the Korea Theological Library were compared. And then, internal tables in Bible, sermon, worship, church history were built and those tables were evaluated by librarians and experts in the fields. And finally, internal tables of the Christiainity and new headings were suggested. New internal tables in Christianity will increase the effectiveness of information retrieval and it will provide a foundation for developing internal tables in other disciplines.

Study of Internal Flow in the supersonic Nozzle by the Hydraulic Analogy (수력학적 상사를 적용한 초음속 노즐 내부 유동 연구)

  • Lee, Ji-Hyung;Lee, Kyung-Hun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.477-482
    • /
    • 2009
  • Though rocket nozzle flow is very important to the rocket performance, the direct measurement is very difficult because of high temperature and high pressure gas flow. Then the experiment utilizing the hydraulic analogy has been developed for such a problem. Supersonic flows through an axisymmetric De Laval nozzle of solid rocket motor was simulated in a 2-D sluice-type water-table designed and manufactured utilizing hydraulic analogy. Methods to minimize or account for non-analogous effects in the hydraulic system must be reviewed for the quantitative application of the hydraulic analogy. In this application the water table is inclined slightly, so that gravity acceleration has a small component in the direction of motion, thus compensating for the effect of friction. Flow visualization leads to better understanding of the analogous system. Within the experimental errors, it is shown that the hydraulic analogy can be used as an effective tool for the study of two dimensional isentropic flows of gases in many fields.

  • PDF