• Title/Summary/Keyword: Internal Matching

Search Result 185, Processing Time 0.029 seconds

Exploring the Ways to Apply Korean Traditional Medical Practices to the International Classification of Health Interventions through Focus Group Discussion (초점집단토론을 통한 국제의료행위분류의 한의의료행위 적용 방안 연구)

  • Kim, Mikyung;Kim, Eun-Jin;Cho, Yun-Jung;Han, Chang-ho
    • The Journal of Korean Medicine
    • /
    • v.41 no.3
    • /
    • pp.125-137
    • /
    • 2020
  • Objectives: This study was aimed to present the experts' opinions for the successful application of Korean traditional medical practices (KTMPs) to the International Classification of Health Intervention (ICHI). Methods: Two doctors of Korean Medicine and two health information managers who had tried coding 131 KTMPs using ICHI participated in the focus group discussion. The remarks from the discussion were summarized according to the thematic analysis method. Results: The participants expected ICHI to be mainly used for statistics when applied to TKMPs. It can be used for payment systems as well, but it was expected that additional work would be required. They thought the current version of the ICHI did not sufficiently reflect the KMTPs of the real world, and even the interventions already included in the ICHI were not explained enough in the system. They thought it would not be easy to explain more KTMPs within the current structure of the ICHI, but they also said it seemed possible. In the process, rather than adding entirely new stem codes, it would be better to generate new combinations of the existing codes, to suppose subdivided codes, and to utilize the include terms or extension codes. Conclusions: For the successful introduction of ICHI, clarifying the definition of each intervention of KTMPs is a top priority. In addition, it is necessary to continue the matching work of ICHI - KMPTs and also required to make this effort together with the field of traditional medicine and complementary medicine worldwide.

Design of temperature sensing circuit measuring the temperature inside of IC (IC내부 온도 측정이 가능한 온도센서회로 설계)

  • Kang, Byung-jun;Kim, Han-seul;Lee, Min-woo;Son, Sang-hee;Jung, Won-sup
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2012.10a
    • /
    • pp.838-841
    • /
    • 2012
  • To avoid the damage to circuit and performance degradation by temperature changes, temperature sensing circuit applicable to the IC is proposed in this paper. Temperature sensing is executed by PTAT circuit and power saving mode is activated by internal switch if internal temperature is in high. Also, characteristics of current matching are increased by using current mirror and cascode circuits. From the simulation results, this circuit is operating in action mode if input signal is in low. But it immediately goes into power saving mode if output signal is in high. It shows the output voltage of 1V at $75^{\circ}C$ and 1.75V at $125^{\circ}C$ in action mode and near 0 V(0V~ 7uV) in power saving mode.

  • PDF

Studies on Comply-composites bonded with Particleboard and Veneer or Plywood (삭편판과 단판 또는 합판을 구성 접착한 콤플라이 복합재에 관한 연구)

  • Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.86-101
    • /
    • 1990
  • The primary objective of this research was to investigate the strength properties of Comply, a composite panel. fabricated with particle board as core material and veneer or plywood as face and back. 20types of comply composites were manufactured according to the four specific gravity levels(0.5, 0.6, 0.7 or 0.8) of particleboard core and three veneer or two plywood thicknesses for face and back. They were tested and compared with matching particleboard (control) on moisture content. specific gravity, bending properties(MOE, MOR SPL). nail resistance and internal bond strength. The obtained results were summarized as follows: The increasing effect of modulus of elasticity was shown by the increase of face and back veneer or plywood thickness. The modulus of rupture and stress at proportional limit of the comply composites bonded with 3mm thick veneers or 3mm thick plywood face and back were higher than 2mm thick veneer or 2mm thick plywood as face and back. Both of modulus of rupture and stress at proportional limit on bending of Comply were higher than those of control board. Also the modulus of elasticity of Comply showed much higher than that of control board. The nail resistance of Comply, composed of plywood as face and back was higher than that of veneer. The nail resistance of control board was higher than that of Comply at Sp.Gr 0.7 and 0.8 core boards. Internal bond of Comply, composed of 1mm and 2mm thick veneer as face and back was higher than that of 3mm thick veneer. The increasing effect of modulus of elasticity was shown by the increase of shelling ratio in Comply composed of veneer and plywood as face and back. The modulus of rupture was increased by the increment of shellmg ratio in Compiy, composed of plywood as face and back. The modulus of elasticity and modulus of. rupture of comply were higher than those of particleboard(control) in effect of shelling ratio. Therefore it was concluded that the mechanical property values of Comply were clearly greater than those of particleboard(control).

  • PDF

Comparison of Radial Artery and Saphenous Vein Composite Y Grafts during Off-pump Coronary Artery Bypass

  • Wi, Jin-Hong;Joo, Hyun-Chel;Youn, Young-Nam;Song, Suk-Won;Kim, Tae Hoon;Yoo, Kyung-Jong
    • Journal of Chest Surgery
    • /
    • v.46 no.4
    • /
    • pp.265-273
    • /
    • 2013
  • Background: The safety and efficacy of arterial composite grafts for total arterial revascularization have been demonstrated. The saphenous vein (SV) is a widely used graft because of its accessibility, sufficient length, and ease of manipulation. Our aim was to compare mid-term outcomes of saphenous vein Y-grafts with radial artery Y-grafts joined by anastomosis to the left internal thoracic artery. Materials and Methods: Records of off-pump coronary artery bypass grafting with composite Y-grafts based on the left internal thoracic artery technique in 552 patients were analyzed retrospectively. After propensity score matching, 79 radial arterial (RA) composite grafts (RA group) and 79 saphenous vein composite grafts (SV group) were compared. The duration of mean follow-up was $24.6{\pm}14.6$ months (range, 1 to 55 months). Results: There were no differences in surgical mortality, all-cause mortality, or morbidity among the groups. Rates of 4-year survival were 91.7% and 96.3% in the RA and SV groups, respectively (p=0.519). The coronary reintervention-free survival rate and freedom from major adverse cardiovascular or cerebrovascular events were similar in the two groups (p=0.685, p=0.564). Conclusion: Construction of composite Y-grafts using the radial artery or saphenous vein showed similar mid-term results. Long-term follow-up and randomized trials will be needed to confirm our present conclusions.

Research about pulse diagnostic technique out of "Nan Jing hoeju jeonjung" ("난경회주전정(難經滙注箋正)"중(中) 맥진(脈診)에 관한 연구(硏究))

  • Park, Keun-Jung;Yoon, Chang-Yeol
    • Journal of Haehwa Medicine
    • /
    • v.15 no.2
    • /
    • pp.39-52
    • /
    • 2006
  • We came to the conclusion as follows from the research about pulse diagnostic technique (脈診) out of "Nan Jinghoeju jeonjung" (難經滙注箋正). 1. "Nan Jing" is practical medical book for clinician and holds different opinions about three portions and nine takings(三部九候脈法) from Huang Di Nei Jing's Taking the pulse of Bu Jung Chim Chon Kwan Chuk((浮中沈 寸關尺) is a quite creative means which has been a important role to future generation. 2. We pointed the differences between western medical science and traditional medical science. And can explain the pulse in western medicine divided from twelve channels of Oriental Medicine. We can explain special connection between heart and lungs using the theory of systemic & pulmonary circulation in western medicine. And this can be a basement of Lung controls every pulse theory in oriental medicine. 3. We have negative assertion about viewing the human body using theory of Yin and Yang-Five Elements. And have poor opinion of explaining about the matching internal organs to Chon Kwan Chuk using the theory of Yin and Yang-Five Elements. 4. We pointed out the mistake that Porak & Sang hwa act for heart. We took pulses considering heart is a real actual internal organ as others. 5. We denied the theory of Man's Chuk pulse is always weak(男子尺脈恒弱) & Woman's Chuk pulse is always strong(女子尺脈恒盛). The physical form of man and woman is not different from each other considering their inheritances from forefather & same shape of organs. So, we cannot insist on the theory.

  • PDF

Positioning by using Speed and GeoMagnetic Sensor Data base on Vehicle Network (차량 네트워크 기반 속도 및 지자기센서 데이터를 이용한 측위 시스템)

  • Moon, Hye-Young;Kim, Jin-Deog;Yu, Yun-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.14 no.12
    • /
    • pp.2730-2736
    • /
    • 2010
  • Recently, various networks have been introduced in the car of the internal and external sides. These have been integrated by one HMI(Human Machine Interface) to control devices of each network and provide information service. The existing vehicle navigation system, providing GPS based vehicle positioning service, has been included to these integrated networks as a default option. The GPS has been used to the most universal device to provide position information by using satellites' signal. But It is impossible to provide the position information when the GPS can't receive the satellites' signal in the area of tunnel, urban canyon, or forest canopy. Thus, this paper propose and implement the method of measuring vehicle position by using the sensing data of internal CAN network and external Wi-Fi network of the integrated car navigation circumstances when the GPS doesn't work normally. The results obtained by implementation shows the proposed method works well by map matching.

3-Port Circulator for X-Band Radar (X-Band 레이더를 위한 3-포트 서큘레이터)

  • Yoon, Sung-Hyun
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.2
    • /
    • pp.355-362
    • /
    • 2015
  • In this study, we have fabricated 9.385[GHz] circulator that is composed of WR112 waveguide and Ferrite for X-band radar. For designing Ferrite, B/R mode(Below Resonance mode) was used and calculated the condition of 120 degree rotation of the electric field in Ferrite and calculated internal DC magnetic field and external DC magnetic field. Also, dielectric materials of the same shape with Ferrite was filled between two Ferrite for improving the performance of the circulator, including impedance matching, bandwidth, quality factor, insertion loss. To obtain optimum shape of the Ferrite and dielectric material, we used CST MWS. Simulation result of the circulator is that 1.02 : 1 VSWR, -40dB isolation, 0.2dB insertion loss and measurement result is that 1.03 : 1, -38dB, 1.2dB at 9.385[GHz]. We can get good agreement at isolation and VSWR, but insertion loss was 1 dB great than simulation result.

Impact of inland waters on highly pathogenic avian influenza outbreaks in neighboring poultry farms in South Korea

  • Ahmad, Saleem;Koh, Kyeyoung;Yoo, Daesung;Suh, Gukhyun;Lee, Jaeil;Lee, Chang-Min
    • Journal of Veterinary Science
    • /
    • v.23 no.3
    • /
    • pp.36.1-36.14
    • /
    • 2022
  • Background: Since 2003, the H5 highly pathogenic avian influenza (HPAI) subtype has caused massive economic losses in the poultry industry in South Korea. The role of inland water bodies in avian influenza (AI) outbreaks has not been investigated. Identifying water bodies that facilitate risk pathways leading to the incursion of the HPAI virus (HPAIV) into poultry farms is essential for implementing specific precautionary measures to prevent viral transmission. Objectives: This matched case-control study (1:4) examined whether inland waters were associated with a higher risk of AI outbreaks in the neighboring poultry farms. Methods: Rivers, irrigation canals, lakes, and ponds were considered inland water bodies. The cases and controls were chosen based on the matching criteria. The nearest possible farms located within a radius of 3 km of the case farms were chosen as the control farms. The poultry farms were selected randomly, and two HPAI epidemics (H5N8 [2014-2016] and H5N6 [2016-2017]) were studied. Conditional logistic regression analysis was applied. Results: Statistical analysis revealed that inland waters near poultry farms were significant risk factors for AI outbreaks. The study speculated that freely wandering wild waterfowl and small animals contaminate areas surrounding poultry farms. Conclusions: Pet birds and animals raised alongside poultry birds on farm premises may wander easily to nearby waters, potentially increasing the risk of AI infection in poultry farms. Mechanical transmission of the AI virus occurs when poultry farm workers or visitors come into contact with infected water bodies or their surroundings. To prevent AI outbreaks in the future, poultry farms should adopt strict precautions to avoid contact with nearby water bodies and their surroundings.

Development of Operational Technology and Integrated Measurement Information Management System for the Radioactivity Measurement Device (방사능 측정장치 운영 기술 및 측정정보 통합관리 시스템 개발)

  • Dong-Sik Jin;Kyeong-Ryeong Kim;Jae-Geun Lee
    • Journal of radiological science and technology
    • /
    • v.47 no.3
    • /
    • pp.183-195
    • /
    • 2024
  • Additional functional upgrades to the large-area compton camera (LACC) measurement device that can provide characteristics evaluation information (nuclear species and radioactivity) and two-dimensional or three-dimensional distribution imaging information of radioactive materials existing in surface or internal of concrete structures are required in terms of work stability and efficiency in order to apply to actual decommissioning sites such as nuclear power plants or medical cyclotron facilities by using this measurement device. To this purpose, the technology that allows radiation workers to intuitively and visually check the distribution of radioactive materials in advance by matching the two-dimensional distribution imaging information of radioactive materials obtained through the LACC measurement device and visual imaging of the measurement zone (10 m × 5 m) was developed. In addition, the separate system that can automatically adjust the position (height) in units of the measurement area size (0.7 m × 0.3 m × 0.8 m) of the LACC measurement device was developed and the integrated management system for characteristics evaluation information and two-dimensional or three-dimensional distribution imaging information obtained per unit of measurement for radioactive materials was developed. These functional upgrades related to LACC measurement device can improve work efficiency and safety when measuring radioactivity of concrete structures and enable the establishment of appropriate decommissioning strategies using radioactivity measurement information for decommissioning nuclear power plants or medical cyclotron facilities.

Enhanced Prediction for Low Complexity Near-lossless Compression (낮은 복잡도의 준무손실 압축을 위한 향상된 예측 기법)

  • Son, Ji Deok;Song, Byung Cheol
    • Journal of Broadcast Engineering
    • /
    • v.19 no.2
    • /
    • pp.227-239
    • /
    • 2014
  • This paper proposes an enhance prediction for conventional near-lossless coder to effectively lower external memory bandwidth in image processing SoC. First, we utilize an already reconstructed green component as a base of predictor of the other color component because high correlation between RGB color components usually exists. Next, we can improve prediction performance by applying variable block size prediction. Lastly, we use minimum internal memory and improve a temporal prediction performance by using a template dictionary that is sampled in previous frame. Experimental results show that the proposed algorithm shows better performance than the previous works. Natural images have approximately 30% improvement in coding efficiency and CG images have 60% improvement on average.