• Title/Summary/Keyword: Internal Loss Analysis

Search Result 356, Processing Time 0.025 seconds

Influence of Internal Partition of Simple Extension Chamber on the Acoustic Transmission Loss (단순 확장 관 내부 파티션이 음향 투과손실에 미치는 영향해석)

  • Park, Jeong-Pil;Jeong, Weui-Bong;Ahn, Se-Jin
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.690-692
    • /
    • 2014
  • To identify characterization of a simple extension chamber that have the two internal partition, produce the curve to estimate the transmission loss without the computer analysis. For helpful for internal optimum design, identify the characteristic of internal partition on transmission loss. Made estimated transmission loss curve by function of relationship of internal partition and transmission. Check the similarity of predicted transmission loss and analysis transmission loss. Usage of the predicted transmission loss made by relationship of internal partition and transmission loss is good information to place the internal partition so as to maximize the transmission loss on target frequency at optimal design on muffler.

  • PDF

A Study on Internal Loss Analysis of Totem Pole Bridgeless PFC and Efficiency Improvement using Parallel Switch (토템폴 브릿지리스 PFC의 내부 손실 분석과 병렬 스위치를 사용한 효율 개선에 관한 연구)

  • Yoo, Jeong Sang;Gil, Yong Man;Yu, Seung Hyup;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.22-27
    • /
    • 2020
  • In this paper, a generalized efficiency equation was proposed to estimate the internal loss of the SMPS (switched-mode power supply) with 3 variables. The first variable was an internal loss not related to the load current such as auxiliary power, the second was a loss proportional to the current such as diode loss, and the third was a loss proportional to square of the current such as conduction loss. Especially, theoretical internal losses of the totem pole bridgeless PFC which is widely used for high efficiency SMPS were expressed as output function to compare generalized efficiency equation. In addition, in order to reduce the conduction loss of the switch, when a multiple switch were paralleled, the correlation with the efficiency was analyzed and shown as a graph. In order to confirm the degree of the parallel switch structure on the efficiency improvement, a 2kW class totem pole bridgeless PFC was constructed and the effectiveness of the analysis was confirmed by comparing the generalized efficiency equation and theoretical loss analysis results with experimental data.

A Study on the Internal Loss and Efficiency Analysis by Loss Factors in PFC Switching Rectifier (PFC 스위칭 정류기에서 손실인자에 의한 내부손실과 효율분석에 관한 연구)

  • Tae Young Ahn
    • Journal of the Semiconductor & Display Technology
    • /
    • v.23 no.2
    • /
    • pp.50-54
    • /
    • 2024
  • In this paper, we propose a theoretical method to systematically analyze the power conversion efficiency of a single-phase PFC switching rectifier. Boost-type PFC was organized in order of highest correlation with load current using steady-state analysis results and introduced the concept of loss factor. The loss factors for each major element are summarized and presented in a table. This paper makes it easier to understand the internal loss and power conversion efficiency of the rectifier for loss factors. Lastly, to confirm the validity of the efficiency analysis results reflecting the loss factors, loss and efficiency analysis of the 2.5kW PFC rectifier was performed. The results were compared with data from a 2.5kW PFC circuit for evaluation. As a result, the usefulness of power conversion efficiency analysis reflecting the loss factors proposed in this paper was confirmed.

  • PDF

Performance analysis of mixed-flow fans considering the low flow characteristics (저유량 특성을 고려한 사류 송풍기의 성능 해석)

  • Oh, Hyoung Woo;Kim, Kwang-Yong
    • 유체기계공업학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.110-115
    • /
    • 2000
  • The mean streamline analysis using the empirical loss correlations has been developed for performance prediction of industrial mixed-flow fan impellers in the present study. New simple, but effective, models for the additional Euler input work characteristic and an internal recirculation loss due to internal flow reversal under the low flowrate conditions are proposed in this paper. Comparison of overall performance predictions with six sets of test data of mixed-flow fans is accomplished to demonstrate the accuracy of the proposed models. Predicted performance curves by the present set of loss models agree fairly well with experimental data for a variety of mixed-flow fan impellers over the entire operating conditions. The prediction method presented herein can be used efficiently in the conceptual design phase of mixed-flow fan impellers.

  • PDF

A Study on the Loss Reduction Method of Reinforcing Bar through Case Study

  • Park, U-Yeol;Jung, Hyeon-Ok;Kang, Tai-Kyung;Cho, Hun-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.10 no.4
    • /
    • pp.123-132
    • /
    • 2010
  • Rebar work accounts for approximately 30% of the total construction costs for rebars and concrete. Recently, the high rising prices of rebars have become one of the principle factors of rising construction costs. Therefore, construction companies are putting much effort into loss reduction of rebars. Consequently, in this study, we wished to present loss reduction methods of rebars before the preparation of the placing drawings. To devise such methods, we collected previous case studies and analyzed methods that were applied for loss reduction. As a result of the analysis, we were able to find the following methods for loss reduction of rebars: method of reducing the number of splices at the mat foundation, method of reducing splice length at the internal columns or walls of the underground parking lot, method of reducing cap-ties of internal beams of basement floors excluding perimeter beams, and method of reducing anchorage length at the internal column or wall of the underground parking lot. Based on those analysis results, we presented our own loss reduction methods of rebars. Applying our methods resulted in considerable loss reduction.

In-hospital malnutrition among adult patients in a national referral hospital in Indonesia

  • Dyah Purnamasari;Nur Chandra Bunawan;Dwi Suseno;Ikhwan Rinaldi;Drupadi HS Dillon
    • Nutrition Research and Practice
    • /
    • v.17 no.2
    • /
    • pp.218-227
    • /
    • 2023
  • BACKGROUND/OBJECTIVES: Malnutrition during hospitalization is linked to increased morbidity and mortality, but there are insufficient studies observing clinical factors contributing to weight loss during hospitalization in Indonesia. This study was therefore undertaken to determine the rate of weight loss during hospitalization and the contributing factors. SUBJECTS/METHODS: This was a prospective study involving hospitalized adult patients aged 18-59 yrs, conducted between July and September 2019. Body weight measurement was taken at the time of admission and on the last day of hospitalization. The factors studied were malnutrition at admission (body mass index < 18.5 kg/m2), immobilization, depression (Beck Depression Inventory-II Indonesia), polypharmacy, inflammatory status (neutrophil-lymphocytes ratio; NLR), comorbidity status (Charlson Comorbidity Index; CCI), and length of stay. RESULTS: Totally, 55 patients were included in the final analysis, with a median age of 39 (18-59 yrs) yrs. Of these, 27% had malnutrition at admission, 31% had a CCI score > 2, and 26% had an NLR value of ≥ 9. In all, 62% presented with gastrointestinal symptoms, and depression was documented in one-third of the subjects at admission. Overall, we recorded a mean weight loss of 0.41 kg (P = 0.038) during hospitalization, with significant weight loss observed among patients hospitalized for 7 days or more (P = 0.009). The bivariate analysis revealed that inflammatory status (P = 0.016) was associated with in-hospital weight loss, while the multivariate analysis determined that the contributing factors were length of stay (P < 0.001) and depression (P = 0.019). CONCLUSIONS: We found that inflammatory status of the patient might influence the incidence of weight loss during hospitalization, while depression and length of stay were independent predictors of weight loss during hospitalization.

A Study on the Optimal Design of LLC Resonant Half-bridge dc-dc Converter Using a Steady-state Model with Internal Loss Resistors (내부 손실 저항이 있는 정상상태 모델을 이용한 LLC 공진형 하프 브리지 dc-dc컨버터의 최적 설계에 관한 연구)

  • Yoo, Jeong Sang;Ahn, Tae Young
    • Journal of the Semiconductor & Display Technology
    • /
    • v.21 no.3
    • /
    • pp.80-86
    • /
    • 2022
  • In this paper, the optimal design and circuit simulation verification results of an LLC resonant half-bridge dc-dc converter using a steady-state model with internal loss resistance are reported. Above all, the input/output voltage gain and frequency characteristic equations in the steady-state were derived by reflecting the internal loss resistance in the equivalent circuit. Based on the results, an LLC resonant half-bridge dc-dc converter with an input voltage of 360-420V, an output voltage of 54V, and a maximum power of 3kW was designed, and to verify the design, the PSIM circuit simulation was executed to compare and analyze the result. In particular, the operating range of the converter could be drawn from the frequency characteristic graph of the voltage gain, and when the converter was operated under light and maximum load conditions, it was confirmed that similar results were obtained by comparing simulation results and calculation results in the switching frequency characteristic graph. In addition, the change of the switching frequency with respect to the load current at each input voltage was compared with the calculated value and the simulation result. As a result, it was possible to confirm the usefulness of the analysis result reflecting the internal loss resistance proposed in this paper and the process of the optimal design.

Application of Piezoelectric Smart Structures for Statistical Energy Analysis (압전 지능 구조물을 이용한 통계적 에너지 해석 기법)

  • 김재환;김정하;김재도
    • Journal of KSNVE
    • /
    • v.11 no.2
    • /
    • pp.257-264
    • /
    • 2001
  • In this research, piezoelectric smart structures are applied for SEA(Statistical Energy Analysis), which is well known approach for high frequency analysis. A new input power measurement based on piezoelectric electrical power measurement is proposed and compared with the conventional method in SEA. As an example, a simple aluminum beam on which piezoelectric actuator is attached is considered. By measuring the electrical impedance and electrical current of the piezoelectric actuator, the electrical power given on the actuator is found and this is In turn converted into the mechanical energy. From the measured value of the stored energy of the beam, the Internal loss factor is calculated and this value shows a good agreement with that given by the conventional method as well as the theoretical value. To compare the coupling loss factor, L-shape beam system which consists of a aluminum beam subsystem and a steel beam subsystem coupled by three pin is taken as second example. The input power and stored energy of each subsystem are found by the proposed approach. The coupling loss factor found by the electrical input power obtained from the piezoelectric actuator exhibits similar trend to the value found by the conventional method as well as the theoretical value. In conclusion, the use of SEA for high frequency application of piezoelectric smart structures is Possible. Especially, the input power that is essential for SEA can be found accurately by measuring the electrical input power of the piezoelectric actuator.

  • PDF

Theoretical Modeling of the Internal Power Flow and Absorption Loss of the Air Mode Based on the Proposed Poynting Vector Analysis in Top-emitting Organic Light-emitting Diodes

  • Kim, Jiyong;Kim, Jungho;Kim, Kyoung-Youm
    • Journal of the Korean Physical Society
    • /
    • v.73 no.11
    • /
    • pp.1663-1674
    • /
    • 2018
  • We propose the Poynting vector analysis of the air mode in a top-emitting organic light-emitting diode (OLED) by combining the transfer matrix method and dipole source term. The spatial profiles of the time-averaged optical power flow of the air mode are calculated inside and outside the multilayer structure of the OLED with respect to the thickness of the semi-transparent top cathode and capping layer (CPL). We elucidate how the micro-cavity effect controlled by the thickness variation of the semi-transparent top cathode or CPL affects the internal optical power and absorption loss inside the OLED multilayer and the external optical power coupled into the air. When the calculated absorption loss and external power obtained by the proposed Poynting vector and currently-used point dipole models are compared, two calculation results are identical, which demonstrates the validity of the two models.

Flow Characteristics of Cryogenic Butterfly Valve for LNG Carrier (Part 1 : CFD Analysis and its Comparison with Experimentation) (LNG선용 버터플라이밸브의 유동특성에 관한 연구 (제1부 : CFD해석과 실험결과의 비교))

  • Kim, Sang-Wan;Choi, Young-Do;Kim, Jung-Hwan;Lee, Young-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.2
    • /
    • pp.13-19
    • /
    • 2008
  • Butterfly valves are widely used as control valves for industrial process. For the definition of optimum configuration of the valve, wide range of related studies has been actively conducted in the case of working fluids of water or air under the normal temperature. Recently, internal flow and performance characteristics of cryogenic butterfly valve for LNG carrier take a growing interest in the field of research and development. Therefore, present study is aimed to investigate the internal flow and performance characteristics of the cryogenic butterfly valve because the study result for the valve can be hardly found at present. Part 1 of this paper describes the study result of a butterfly valve model under the condition of the normal temperature. Succeeding Part 2 of this paper will describe the internal flow characteristics of a cryogenic butterfly valve for LNG carrier. The results of Part 1 show that pressure loss coefficients and flow rate coefficients obtained by the present experiment and CFD analysis agree well each other. Moreover, internal flow visualization for the valve by CFD analysis and PIV measurement have revealed complicated flow patterns of the internal flow field in detail.