• Title/Summary/Keyword: Internal Element

Search Result 1,359, Processing Time 0.03 seconds

Design of Tissue-Transfer Container Using Thermoelectric Element Module

  • Park, Yong Pil;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • v.18 no.2
    • /
    • pp.66-69
    • /
    • 2017
  • The internal temperature of human-tissue transfers must be steadily maintained regardless of the external environmental changes. An ice pack and dry ice are the coolants for the transfer containers for which heat-insulating materials such as EPP (expended polypeopylene and EPS (expended polystrene) are used; however, changes of the external temperature/pressure and the melting of the coolants that is due to a long carriage result in changes of the internal temperature, and this makes it difficult to maintain the temperature. Accordingly, the thermoelectric element was used to design/manufacture a transfer container to maintain the internal temperature regardless of the external environmental changes. As a result of the measurement of the changes of the internal temperatures of the manufactured thermoelectric-element container and the EPS container over time, the internal temperature of the EPS container was increased, whereas the internal temperature of the thermoelectric-element container was maintained. The temperature of the distilled water that was poured into the containers indicated a pattern identical to that of the internal temperature.

A study on the solution stability by the position of internal nodes in hihger order isoparametric elements (고차 등매개요소에서 내부절점의 위치와 해의 안정성 연구)

  • Lee, Joon-Hee;Lim, Jang-Keun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.12
    • /
    • pp.1973-1983
    • /
    • 1997
  • Higher order isoparametric elements are usually used in the finite element analysis because they can represent easily the geometric shape of a complex structure ad can improve the solution quality. When these elements are used, the position of internal nodes affects greatly on the solution accuracy. Decreasing of the accuracy related to the position of internal nodes is due to non-conformal mapping often results in an unstable Jacobian value. This paper, in order to remove this difficulty, suggests a modified shape function which can establish conformal mapping between two coordinate systems. Numerical experiments with the proposed shape function show that a stable solution can be obtained without respect to the position of internal nodes, and offer convenience that one can take arbitrarily the position of internal nodes considering only the geometric shape of element boundaries.

Spectral Element Analysis of the Pipeline Conveying Internal Unsteady Fluid (내부 비정상 유동을 갖는 파이프계의 스펙트럼요소해석)

  • Park, Jong-Hwan;Lee, U-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.12 s.243
    • /
    • pp.1574-1585
    • /
    • 2005
  • In this paper, a spectral element model is developed for the uniform straight pipelines conveying internal unsteady fluid. Four coupled pipe-dynamics equations are derived first by using the Hamilton's principle and the principles of fluid mechanics. The transverse displacement, the axial displacement, the fluid pressure and the fluid velocity are all considered as the dependent variables. The coupled pipe-dynamics equations are then linearized about the steady state values of the fluid pressure and velocity. As the final step, the spectral element model represented by the exact dynamic stiffness matrix, which is often called spectral element matrix, is formulated by using the frequency-domain solutions of the linearized pipe-dynamics equations. The FFT-based spectral dynamic analyses are conducted to evaluate the accuracy of the present spectral element model and also to investigate the structural dynamic characteristics and the internal fluid transients of an example pipeline system.

An Analysis of Internal & External Duct Acoustic Fields by Using a Finite Element Method (유한요소법을 이용한 도관 내부 및 외부 음장해석)

  • 이재규;이덕주
    • Journal of KSNVE
    • /
    • v.3 no.2
    • /
    • pp.169-178
    • /
    • 1993
  • Internal & External duct acoustic fields are calculated by using a finite element method. The geometry is assumed as an axisymmetric duct. External acoustic field; outside the duct, and combined internal & external acoustic fields are solved. For both cases a far field's nonreflecting boundary condition is enforced by using a wave envelope element, which is a kind of finite element. First, a pulsating sphere and an oscillating sphere problem are calculated to verify the external problems, and the results are compared with exact solutions. When the wave envelope element is applied at the far boundary, the calculated finite element solutions show good agreements with the exact solutions. Secondly, the combined internal & external duct acoustic fields are calculated and visualized when monopole sources are distributed inside the duct. It is observed that the directivity of sound intensity outside the duct is beaming toward the axis for high frequency sources.

  • PDF

Spectral Element Vibration Analysis of the Pipeline Conveying Internal Flow (내부유동을 갖는 파이프 진동의 스펙트럴요소해석)

  • Oh, Hyuck-Jin;Kang, Kwan-Ho;Lee, U-Sik
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.2
    • /
    • pp.294-301
    • /
    • 2003
  • It is of often important to accurately predict the flow-induced vibration or dynamic instability of a pipeline conveying internal high speed flow in advance, which requires a very accurate solution method. In this study, first the dynamic equations for the axial and transverse vibrations of a pipeline are reduced from a set of pipe-dynamic equations derived in the previous study and then the spectral element model is formulated. The accuracy of the spectral element method (SEM) is then verified by comparing its results with the results obtained by finite element method (FEM). It is shown that the present spectral element model provides very accurate solutions by using an extremely small number of degrees-of-freedom when compared with FEM. The dynamics of a sample pipeline is investigated with varying the axial tension and the speed of internal flow.

A Case Report of Broca’s Aphasia after Cerebral Infarction by Korean Medical Treatment including Five-Element Acupuncture (오행침자법(五行鍼刺法)을 포함한 한방치료로 호전된 뇌경색 후 발생한 Broca 실어증 치험 1례)

  • Kim, Tae-ryun;Lim, Hyun-chan;Jeon, Sang-yun
    • The Journal of Internal Korean Medicine
    • /
    • v.37 no.3
    • /
    • pp.568-577
    • /
    • 2016
  • Objective: To report the case of a patient suffering from Broca’s aphasia after cerebral infarction, which was improved by Korean medical treatments, especially five-element acupuncture.Methods: To relievesymptoms, Korean medicine treatments such as acupuncture, moxibustion, and herb medication were performed. To evaluate the effect of the treatments, articulation accuracy, vowel accuracy, and the sequential motion rate of articulator were checked.Result: After treatments for 28 days, the symptoms were improved.Conclusion: This report suggests that five-element acupuncture can be effectively used for patients with Broca’s aphasia after cerebral infarction.

An Evaluation of the Effect of Internal Thinning Defect on the Failure Pressure of Elbow (곡관의 손상압력에 미치는 내부 감육결함의 영향 평가)

  • Kim, Jin-Weon;Kim, Tae-Soon;Park, Chi-Yong
    • Journal of the Korean Society of Safety
    • /
    • v.18 no.4
    • /
    • pp.28-34
    • /
    • 2003
  • In the present study, three-dimensional finite element analysis was performed to investigate the effects of internal wall thinning defect on the failure pressure of elbow in the piping system and to develop the failure pressure evaluation model. From the results of finite element analysis, the failure pressure was derived by employing local stress criteria, and the effects of thinning location, bend radius, and defect geometry on the failure pressure of internally wall thinned elbow were investigated. Also, based on these investigations and previous model developed to estimate the failure pressure of elbow with an external pitting defect, the failure pressure evaluation model to be applicable to the elbow containing an internal thinning defect was proposed and compared with the results of finite element analysis. The failure pressure calculated by the model agreed well with the results of finite element analysis.

Optimisation of symmetric laminates with internal line supports for maximum buckling load

  • Walker, M.
    • Structural Engineering and Mechanics
    • /
    • v.6 no.6
    • /
    • pp.633-641
    • /
    • 1998
  • Finite element solutions are presented for the optimal design of symmetrically laminated rectangular plates with various types of internal line supports. These plates are subject to a combination of simply supported, clamped and free boundary conditions. The design objective is the maximisation of the biaxial buckling load. This is achieved by determining the fibre orientations optimally with the effects of bending-twisting coupling taken into account. The finite element method coupled with an optimisation routine is employed in analysing and optimising the laminated plate designs. The effect of internal line support type and boundary conditions on the optimal ply angles and the buckling load are numerically studied. The laminate behavior with respect to fibre orientation changes significantly in the presence of internal line supports as compared to that of a laminate where there is no internal supporting. This change in behavior has significant implications for design optimisation as the optimal values of design variables with or without internal supporting differ substantially.

Vibration Analysis of the Pipeline with Internal Unsteady Fluid Flow by Using Spectral Element Method (스펙트럴요소법을 이용한 내부 비정상류를 갖는 파이프에 대한 진동해석)

  • Seo, Bo-Sung;Cho, Joo-Yong;Lee, U-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.4 s.109
    • /
    • pp.387-393
    • /
    • 2006
  • In this paper, a spectral element model is developed for the uniform straight pipelines conveying internal unsteady fluid flow. The spectral element matrix is formulated by using the exact frequency-domain solutions of the pipe-dynamics equations. The spectral element dynamic analysis is then conducted to evaluate the accuracy of the present spectral element model and to investigate the vibration characteristics and internal fluid characteristics of an example pipeline system.

A Study on the Joint Element Connection of Joint Element Structure Method (JES 공법의 JOINT ELEMENT 이음부에 관한 연구)

  • 엄기영;박명준
    • Journal of the Korean Society for Railway
    • /
    • v.5 no.3
    • /
    • pp.133-141
    • /
    • 2002
  • Recently developed JES(Joint Element Structure) Method was researched as a more safe and economic method than other under pass construction method and was applied to many construction sites. The joint element connection of JES Method is the most important factor for the to behavior of structure. The connection of JES method is filled with the mortar, and the steel and mortar of connections produce the same behavior as one material. The results of experience and numerical analysis are following: The maximum internal stress of connection is decided by the end of connection. also, The connection of joint element structure method have sufficient internal stress against fatigue.