• Title/Summary/Keyword: Internal Defect

Search Result 444, Processing Time 0.04 seconds

INFLUENCE OF INCLUSION ON INTERNAL DEFECT IN MULTI-STAGE EXTRUSION

  • Yoshida Y.;Fukaya Y.;Yukawa N.;Ishikawa T.;Ito K.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.10b
    • /
    • pp.51-54
    • /
    • 2003
  • Internal defects such as chevron crack occasionally occur in the process of cold extrusion or cold drawing. It is known that the existence and property of inclusion greatly influences the generation of the internal crack. However, in the plastic working field, research about the effect of the inclusion on the fracture is not theoretically analyzed. This paper describes effects of the physical property of inclusion on the internal fracture generation in the process. Prediction of fracture was evaluated by critical damage value calculated by the equation of Cockcroft & Latham and its change by the inclusion physical property such as size and stiffness was investigated.

  • PDF

Effect of Shrinkage Defect on Fracture Impact Energy of A356 Cast Aluminum Alloy (A356 알루미늄 합금의 파단 충격에너지에 대한 수축공결함의 영향)

  • Chul, Hwang-Seong;Kwak, Si-Young
    • Journal of Korea Foundry Society
    • /
    • v.34 no.1
    • /
    • pp.22-26
    • /
    • 2014
  • Internal defects, such as shrinkage during casting, cause stress concentrations and initiate cracking. Therefore, it is important to understand the effects of internal defects on the mechanical properties including the impact behavior. This study evaluates the effects of internal casting defects on the impact performance of A356 Al-alloy castings. The internal shrinkage defects in the casting impact specimen are scanned using an industrial Computed Tomography (CT) scanner, and drop impact tests are performed with varing impact velocities on the A356 casting aluminium specimen ($10mm{\times}10mm$ section area) in order to locate the fracture energy under an impact load. The specimens with defects with a diameter less than 0.35 mm exhibit equivalent fracture impact energies of approximately 32 J and those with a 1.7 mm diameter defect reduced the fracture impact energy by 35%.

Comparison of Polar Maps of Dipyridamole Stress/Rest MIBI Myocardial SPECT and Coronary Angiography in Coronary Artery Disease (관동맥질환에서 디피리다몰부하 $^{99m}Tc$-MIBI 심근 SPECT 극성지도와 관동맥 조영소견의 비교)

  • Lee, Myung-Chul;Lee, Dong-Soo;Lee, Myung-Yong;Choi, Chang-Woon;Sohn, Dae-Won;Chung, June-Key;Lee, Myong-Mook;Park, Young-Bae;Seo, Jung-Don;Lee, Young-Woo;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.1
    • /
    • pp.51-58
    • /
    • 1993
  • We have anlayzed the polar maps of dipyridamole stress/rest $^{99m}Tc$-MIBI SPECT and compared the quantitated perfusion defects of dipyridamole stress polar map and the findings of coronary angiography in 56 pateints with coronary artery diseases. We performed the same day dipyridamole stress-rest myocardial SPECT, reconstructed the polar maps according to Cedars-Sinai method and quantitated perfusion detects of total myocardium and the territory of each artery, comparing the polar maps of patients with normal files. Stenosis more than 50 percent was considered significant and myocardial ischemic score was calculated as summed score of percents of main coronary arteries. Positive concordance of myocardial SPECT with coronary angiography were 82.6% with left anterior descending artery (LAD), 85.7% with left circumflex artery (LCx) and 78.6% with right coronary artery (RCA). Perfusion defect of SPECT polar map and the stenosis of coronary artery showed the contingency phi of 0.55 (p<0.0001) with total atreries, 0.38 (p = 0.016) with LAD, 0.50 (p<0.0001) with LCx and 0.40 (p = 0.007) with RCA. Dipyridamole stress percent defect of polar map was correlated with myocardial ischemic score with Spearman's rho of 0.47 (p = 0.001) in total arteries, 0.48 (p=0.001) in LAD, 0.56 (p < 0.001) in LCx and 0.38 (p=0.002) in RCA. These findings revealed that defect of the dipyridamole stress myocardial $^{99m}Tc$-MIBI SPECT and the percent extent of this defect were related with significant artery stenosis of individual arteries and the degree of stenosis. We thought that we could use the defects in the polar map of dipyridamole stress $^{99m}Tc$-MIBI SPECT for the quantification of myocardiasl perfusion decrease.

  • PDF

Modeling for the Fatigue Analysis of Al Alloy Casting Containing Internal Shrinkage Defect (내부 결함을 포함하는 알루미늄 합금 주조품의 피로해석을 위한 모델링)

  • Lee, Sung-Won;Kim, Hak-Ku;Hwang, Ho-Young;Kwak, Si-Young
    • Journal of Korea Foundry Society
    • /
    • v.30 no.5
    • /
    • pp.196-200
    • /
    • 2010
  • The structural stress and fatigue behavior of tensile specimen containing internal shrinkage defect were modeled. Real shrinkage defect in casting was scanned by industrial CT (computed tomography), and subsequently its shape was simplified by ellipsoidal primitives for the structural analysis (S.S.M., shape simplification method). The analysis results were compared with the results by real shrinkage shape without any simplification process. It was possible to consider real shrinkage of casting in stress analysis and the method to predict fatigue life of casting with defect was proposed.

A Study on the Development of Aluminum Piston by Forging Process (알루미늄 단조 피스톤의 개발에 관한 연구)

  • Kim, Y.H.;Bae, W.B.;Kim, H.S.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.9
    • /
    • pp.30-36
    • /
    • 1997
  • In this study, the development of an aluminum forged piston was tried to substitute the cast piston, in which there were internal defects such as blow hole and shrink pipe. A gasoline engine piston was chosen as an example for developing the forged piston. Before aluminum forging, model, material (plasticine) test was carried out to investigate the forgeability and internal flow pattern of the forged piston at room temperature. From the result of model material test, an aluminum piston to be forged was redesigned. The aluminum pistion was forged in hot process. The quality of a forged piston was compared with that of a cast piston in the point of mechanical properties, internal defect and microstructure. It was proved that the forged piston was superior to the cast piston.

  • PDF

A Case Report of Ventricular Septal Defect with Bacterial Endocarditis and Pulmonic Valve Vegetation (심실중격결손증 환자에서 심내막염 및 폐동맥판막 증식물이 관찰되었던 1예 보고)

  • Park, Wha-Chong;Kim, Young-Jo;Sim, Bong-Sup;Kim, Chong-Suhl;Lee, Dong-Hyup;Lee, Cheol-Joo;Cho, Bum-Koo
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.241-247
    • /
    • 1985
  • Bacterial endocarditis has been well recognized as an important complication of congenital heart disease, such as ventricular septal defect, patent ductus arteriosus or pulmonary stenosis. The incidence of right sided bacterial endocarditis is lesser than left sided bacterial endocarditis. Also, pulmonic valve vegetation has been thought to be relatively uncommon. And pulmonary embolism is common in the patients with right sided bacterial endocarditis. So in a patient with fever and evidence of recurrent pulmonary infarction, changing heart murmurs and scattered pneumonic infiltrates, one should direct attention to the heart as a possible source of the infection. Echocardiography with M-mode, 2-D and Doppler mode represents the only noninvasive technic available for detecting vegetations in bacterial endocarditis. In fact, the technic is more sensitive in identifying these lesions than angiography. We experienced a case of ventricular septal defect with bacterial endocarditis, pulmonic valve vegetation and multiple pulmonary embolism diagnosed with Echocardiogram and lung scan, and confirmed by operation. Patch repair of ventricular septal defect, resection of pulmonic valve and vegetation and artificial valve formation with pericardium were done.

  • PDF

Design and Fabrication of Rogowski-type Partial Discharge Sensor for Insulation Diagnosis of Cast-Resin Transformers (몰드 변압기의 절연 진단을 위한 로고우스키형 부분방전 센서의 설계 및 제작)

  • Lee, Gyeong-Yeol;Kim, Sung-Wook;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.6
    • /
    • pp.594-602
    • /
    • 2022
  • Cast-resin transformers are widely installed in various electrical power systems because of their low operating cost and low influence on external environmental factors. However, when they have an internal defect during the manufacturing process or operation, a partial discharge (PD) occurs, and eventually destroys the insulation. In this paper, a Rogowski-type PD sensor was studied to replace commercial PD sensors used for the insulation diagnosis of power apparatus. The proposed PD sensor was manufactured with four different types of PCB-based winding structures, and it was analyzed in terms of the detection characteristics for standard calibration pulses and the changes of the output voltage according to the distance. The output increased linearly in accordance with the applied discharge amount. It was confirmed that the hexagon structure sensor had the highest sensitivity, because the winding cross-sectional area of the sensor was larger than others. In addition, as the distance from the defect increased, the output voltage of the sensors decreased by 7.32% on average. It was also confirmed that the attenuation rate according to the distance decreased as the input discharge amount increased. For the application of this new type sensor, PD electrode system was designed to simulate the void defect. Waveforms and PRPD patterns measured by the proposed PD sensors at DIV and 120% of DIV were the same as the results measured by MPD 600 based on IEC 60270. The proposed PD sensors can be installed on the inner wall of the transformer tank by coating its surfaces with a non-conductive material; therefore, it is possible to detect internal defects more effectively at a closer distance from the defect than the conventional sensors.