• Title/Summary/Keyword: Intermittent Signal

Search Result 41, Processing Time 0.023 seconds

Study on the Measurements of Architectural Acoustie by Cross-Correlation Methods (상호상관법에 의한 건축음향측정에 관한 연구)

  • Park, Byoung-Jeon;Shin, Young-Moo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.42-52
    • /
    • 1990
  • A method of measuring impulse response of acoustic system, two kinds of cross-correlation methods (the direct correlation method and the M-sequence modulation correlation method) were applied. According to the direct correlation method, by using stationary random noise source and by calculating the cross-correlation function between the sourece and the output signal, equivalent impulse response can be obtained not being influenced by the back ground noises. By applying this method, the measurement of echo-time patterns in rooms and oblique incident sound absorption characteristics of sound absorbing materials was carried out. In the case of the M-sequence modulation correlation method which was contrived by Aoshima, an intermittent random nosie modulated by M-sequence signal is used as the source signal, and the cross-correlation function between the M-sequence signal and the squared output signal is calculated. According to this method, equivalent energy impulse response (squared impulse response) of te propagation system can be obtained without being influenced by the back ground noises and the air fluctuation caused by wind. As the applcaition of this measuring method to the architectural acoustics, the meaurements of echo-time patterns, reverberation decays and sound pressure lev디 distributions in rooms and sound insulation efficiencies in buildings were carried out. From these experimental studies, it has been found that this M-sequence modulation correlation method is markedly useful especially for the field masurement of sound insulation under high back ground noise condition.

  • PDF

Cable Fault Detection Improvement of STDR Using Reference Signal Elimination (인가신호 제거를 이용한 STDR의 케이블 고장 검출 성능 향상)

  • Jeon, Jeong-Chay;Kim, Taek-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.450-456
    • /
    • 2016
  • STDR (sequence time domain reflectometry) to detect a cable fault using a pseudo noise sequence as a reference signal, and time correlation analysis between the reference signal and reflection signal is robust to noisy environments and can detect intermittent faults including open faults and short circuits. On the other hand, if the distance of the fault location is far away or the fault type is a soft fault, attenuation of the reflected signal becomes larger; hence the correlation coefficient in the STDR becomes smaller, which makes fault detection difficult and the measurement error larger. In addition, automation of the fault location by detection of phase and peak value becomes difficult. Therefore, to improve the cable fault detection of a conventional STDR, this paper proposes the algorithm in that the peak value of the correlation coefficient of the reference signal is detected, and a peak value of the correlation coefficient of the reflected signal is then detected after removing the reference signal. The performance of the proposed method was validated experimentally in low-voltage power cables. The performance evaluation showed that the proposed method can identify whether a fault occurred more accurately and can track the fault locations better than conventional STDR despite the signal attenuation. In addition, there was no error of an automatic fault type and its location by the detection of the phase and peak value through the elimination of the reference signal and normalization of the correlation coefficient.

Intraparenchymal Sylvian Fissure Meningioma

  • Ko, Byung-Su;Jung, Shin;Jung, Tae-Young;Kim, In-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.2
    • /
    • pp.120-122
    • /
    • 2007
  • Meningiomas arise from meningothelial cells that line the arachnoid membrane. So most meningiomas are dural-based lesion. But meningiomas without dural-attachment do occur and are less common. We report our experience of intraparenchymal sylvian fissure menigioma. A 21-year-old female presented with a one-month history of headache that was associated with long-term intermittent partial seizure. CT revealed about $4.5{\times}4.3{\times}5.5cm$ sized calcified mass with enhancement in right temporal lobe. On MR imaging, the lesion was observed in the right temporal lobe that was low-signal intensity on T2WI and iso-signal intensity on T1WI with well enhancement. Operation was performed via right orbitocranial approach. The internal surface of dura was intact. Tumor was totally removed except the capsule of tumor adhered to main trunk of middle cerebral artery. The histopathology showed meningioma, psammomatous type. Intraparenchymal meningioma should be considered in the differential diagnosis of intraaxial lesions in patients of any age group.

A Study on the Application of Acoustic Emission Measurement for the In-process Detection of Milling Tools' Wear and Chipping (밀링 공구마멸과 치핑의 검출을 위한 음향방출 이용에 관한 연구)

  • Yoon, J.H.;Kang, M.S.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.11 no.1
    • /
    • pp.31-37
    • /
    • 1991
  • Acoustic emission(AE) signals detected during metal cutting were applied as the experimental test to sensing tool wear and chipping on the NC vertical milling machine. The in-process detection of cutting tool wear including chipping, cracking and fracture has been investigated by means of AE in spite of vibration or noise through intermittent metal cutting, then the following results were obtained 1) When the tool wear is increased suddenly, or the amplitude of AE signals changes largely, it indicates chipping or breaking of the insert tip. 2) It was confirmed that AE signal is highly sensitive to the cutting speed and tool wear. 3) At the early period of cutting, the wear were large and RMS value increased highly by the influence of minute chipping and cracking, etc. Therefore, the above situations should be considered for the time when the tool would be changed.

  • PDF

Case Study of Intermittent Engine Hesitation Fault Diagnosis By CKPS Fault (LPI차량에서 CKPS불량으로 주행 중 간헐적인 엔진부조 현상의 고장진단)

  • Kim, Sung Mo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.6
    • /
    • pp.624-629
    • /
    • 2014
  • The purpose of this study is to carry out the task of engine hesitation which occurred intermittently in driving due to the defective CKPS of LPI vehicles. As the result of the wrong data from the equipment of D-logger, the signal error of CKPS caused the engine hesitation. We performed a study in the followings to analyze and investigate the cause effectively. First, we have investigated the control wiring harness and connector pin contact defect inspection. Second, we have inspected the defection of CKPS separately. From this study, it was found that the engine hesitation were caused by the bad durability and we have showed how to diagnosis the fault of the engine hesitation intermittently while driving. Therefore, it is determined that we have to improve the durability of the CKPS through a strict quality control and to increase the reliability.

An Experimental Study on Two Parameter Control for Radiant Floor Heating System

  • Cho, Sung-Hwan;Tae, Choon-Seob;Jang, Chel-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.136-147
    • /
    • 1998
  • An experimental facility consisting of two 3$\times$4.4$\times$2.8m rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparison of two different control strategies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study: (ⅰ) conventional on-off control based on feedback from room air temperature (ⅱ) TPSC(two parameter switching control )(ⅲ) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.

  • PDF

A Study on Micro ED-Drilling of cemented carbide (초경합금의 미세방전 드릴링에 관한 연구)

  • Kim, Chang-Ho;Kang, Soo-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.9 no.5
    • /
    • pp.1-6
    • /
    • 2010
  • The wavelet transform is a popular tool for studying intermittent and localized phenomena in signals. In this study the wavelet transform of cutting force signals was conducted for the detection of a tool failure in turning process. We used the Daubechies wavelet analyzing function to detect a sudden change in cutting signal level. A preliminary stepped workpiece which had intentionally a hard condition was cut by the inserted cermet tool and a tool dynamometer obtained cutting force signals. From the results of the wavelet transform, the obtained signals were divided into approximation terms and detailed terms. At tool failure, the approximation signals were suddenly increased and the detailed signals were extremely oscillated just before tool failure.

Mouse Somatosensory Cortex Stimulation Using Pulse Modulated Transcranial Magnetic Stimulation (구형파 변조된 경두개 자기자극을 이용한 쥐의 감각피질 자극실험)

  • Sun, Sukkyu;Seo, Taeyoon;Huh, Yeowool;Cho, Jeiwon;Kwon, Youngwoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.5
    • /
    • pp.482-485
    • /
    • 2016
  • In this work, a transcranial magnetic stimulation(TMS) experiment on animals is performed to stimulate the brain cortex of the mouse using modulated signals. The proposed TMS system is composed of the inverter, transformer, capacitor, variable inductor, and stimulation coil to generate 1.5 mT magnetic field in the brain cortex of the mouse. The stimulation signal is modulated to square wave where the carrier frequency is swept from 85 to 91 kHz to investigate the stimulation effect. The experimental result shows that when the carrier frequency of the stimulation signal is lower than 89 kHz, the reaction of the mouse does not change while the stimulation signal which has the carrier frequency higher than 89 kHz results in decreasing the threshold of the stimulus for the pressure.

Effects on Localization by the Period Variation of Measured Position (위치인식 신호획득 주기변화에 의한 위치추정값 영향)

  • Shin, Changjoo;Kwon, Osoon;Seo, Jungmin;Kang, Hyoun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.3
    • /
    • pp.23-28
    • /
    • 2019
  • A track type underwater construction robot(URI-R) which can trench on seabed is being developed by Korea Institute of Ocean Science & Technology. During the underwater trenching work, the robot is exposed high intensive noise and vibration so the underwater localization signal may not be obtained properly by the acoustic tracking system. Therefore it is necessary to research about continuous localization even though the measured position signal comes in intermittently. In this paper, the experiments were carried out on land to simulated the underwater operating environment characteristics. To estimate its position, inertial navigation system and global navigation satellite system are used. The effects of the period variation while localizing is investigated by the experiments, and the application for URI-R is proposed.

Analysis of Reference Signal for Immunity Test of Sound System and Television Broadcast Receiver (음향 기기 및 TV 방송 수신기의 내성 시험용 기준 신호 분석)

  • Choi, Su-Na;Cho, Sung-Woong;Park, Seung-Keun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.7
    • /
    • pp.805-814
    • /
    • 2012
  • Intermittent or periodic signals with undulating amplitudes of mobile devices cause interference noise at audible frequency to the sound system which is installed nearby. In this regard, it is recently issued that the intermittently transmissions of LTE mobile phones cause the interference noises with sound systems, similar to that of GSM mobile phones. For retaining the immunity to noises, a national regulation KN20 suggests a 1 kHz AM 80 % and a CDMA modulation signal as reference signals for immunity test of sound and television broadcast receiver. In this paper, the effects of interference noises of AM and CDMA are compared with those of GSM and LTE, and the improvement of reference signal for national immunity test of sound systems is suggested. It is recommended to delete the CDMA modulation signal from reference signals for immunity test because it hardly cause interference noise with sound systems. On the other hand, it is desirable to select the modulation signal of LTE instead of CDMA as a reference signal for immunity test of sound system and television broadcast receiver because many people use the LTE service and it is analysed that the LTE signal causes considerable interference noises.