• 제목/요약/키워드: Intermittent Generation

검색결과 70건 처리시간 0.024초

Intermittent Fasting Modulates Immune Response by Generating Tregs via TGF-β Dependent Mechanisms in Obese Mice with Allergic Contact Dermatitis

  • Sang-Chul Han;Jung-Il Kang;Youn Kyung Choi;Hye-Jin Boo;Weon-Jong Yoon;Hee-Kyoung Kang;Eun-Sook Yoo
    • Biomolecules & Therapeutics
    • /
    • 제32권1호
    • /
    • pp.136-145
    • /
    • 2024
  • People with obesity maintain low levels of inflammation; therefore, their exposure to foreign antigens can trigger an excessive immune response. In people with obesity or allergic contact dermatitis (ACD), symptoms are exacerbated by a reduction in the number of regulatory T cells (Tregs) and IL-10/TGF-β-modified macrophages (M2 macrophages) at the inflammatory site. Benefits of intermittent fasting (IF) have been demonstrated for many diseases; however, the immune responses regulated by macrophages and CD4+T cells in obese ACD animal models are poorly understood. Therefore, we investigated whether IF suppresses inflammatory responses and upregulates the generation of Tregs and M2 macrophages in experimental ACD animal models of obese mice. The IF regimen relieved various ACD symptoms in inflamed and adipose tissues. We showed that the IF regimen upregulates Treg generation in a TGF-β-dependent manner and induces CD4+T cell hypo-responsiveness. IF-M2 macrophages, which strongly express TGF-β and inhibit CD4+T cell proliferation, directly regulated Treg differentiation from CD4+T cells. These results indicate that the IF regimen enhances the TGF-β-producing ability of M2 macrophages and that the development of Tregs keeps mice healthy against ACD exacerbated by obesity. Therefore, the IF regimen may ameliorate inflammatory immune disorders caused by obesity.

독립형 마이크로그리드내 풍력발전출력이 주파수 품질에 미치는 영향 분석 (Study on Impact of Wind Power in Grid Frequency Quality of Stand-alone Microgrid)

  • 허재선;김재철
    • 조명전기설비학회논문지
    • /
    • 제30권3호
    • /
    • pp.79-85
    • /
    • 2016
  • This paper analyzed the influence of wind power fluctuations in grid frequency of a stand-alone microgrid that is hybrid generation system with diesel generator, wind turbine, and Battery Energy Storage System (BESS). The existing island area power system consists of only diesel generators. So the grid frequency can be controllable from load change. But hybrid generation system with Renewable Energy Sources (RES) such as wind energy that has the intermittent output can bring power quality problems. BESS is one of the ways to improve the intermittent output of the RES. In this paper, we analyzed the role of BESS in a stand-alone microgrid. We designed a modelling of wind power system with squirrel-cage induction generator, diesel power system with synchronous generator, and BESS using transient analysis program PSCAD/EMTDC. And we analyzed the variation of the grid frequency according to the output of BESS.

고조파 전류가 변압기 진동에 미치는 영향에 관한 연구 (The Study of the Harmonic Currents Effects on the Transformer Vibration)

  • 김수열;김연환;김장목;임익헌;이현
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.106-111
    • /
    • 2000
  • EP(Electrostatic Precipitator) has been used to keep the natural environment from fly-ash in the industrial fields and operated in intermittent PEC(Pulse Energized Control) mode to improve dust-collecting efficiency. Intermittent PEC mode induces low-frequency harmonic currents into power system, therefore EP transformer vibrates. This continuous transformer vibration developes transformer abnormal audio-noise and if it is too much or operates in the region of natural frequency, transformer will be damaged in the end. EP interruption caused by transformer damage results in power generation stopped, power quality down and economic loss. Therefore, this paper explains harmonic currents and transformer vibration-core vibration, winding vibration, and proposes the measures of suppressing the vibration with EP operated in intermittent PEC mode. And this results is proposed to be used for future EP transformer design or EP control method to operate EP-concerned equipment safely keeping from system faults caused by transformer vibration.

  • PDF

Control strategies of energy storage limiting intermittent output of solar power generation: Planning and evaluation for participation in electricity market

  • Sewan Heo;Jinsoo Han;Wan-Ki Park
    • ETRI Journal
    • /
    • 제45권4호
    • /
    • pp.636-649
    • /
    • 2023
  • Renewable energy generation cannot be consistently predicted or controlled. Therefore, it is currently not widely used in the electricity market, which requires dependable production. In this study, reliability- and variance-based controls of energy storage strategies are proposed to utilize renewable energy as a steady contributor to the electricity market. For reliability-based control, photovoltaic (PV) generation is assumed to be registered in the power generation plan. PV generation yields a reliable output using energy storage units to compensate for PV prediction errors. We also propose a runtime state-ofcharge management method for sustainable operations. With variance-based controls, changes in rapid power generation are limited through ramp rate control. This study introduces new reliability and variance indices as indicators for evaluating these strategies. The reliability index quantifies the degree to which the actual generation realizes the plan, and the variance index quantifies the degree of power change. The two strategies are verified based on simulations and experiments. The reliability index improved by 3.1 times on average over 21 days at a real power plant.

독립형 소형 태양광/풍력 복합발전시스템의 출력안정화를 위한 보조 전력보상장치개발에 관한 연구 (The Auxiliary Power Compensation Unit for Stand-Alone Photovoltaic/Wind Hybrid Generation System)

  • 박세준;윤정필;강병복;윤형상;차인수;임중열
    • 한국태양에너지학회 논문집
    • /
    • 제24권3호
    • /
    • pp.47-54
    • /
    • 2004
  • Photovoltaic energy and wind energy are highly dependent on the season, time and extremely intermittent energy sources. Because of these reasons, in view of the reliability the photovoltaic and the wind power generation system have many problems(energy conversion, energy storage, load control etc.) comparing with conventional power plant. In order to solve these existing problems, hybrid generation system composed of photovoltaic(500W) and wind power system(400W) was suggested. But, hybrid generation system cannot always generate stable output due to the varying weather condition. So, the auxiliary power compensation unit that uses elastic energy of spiral spring was added to hybrid generation system for the present study. It was partly confirmed that hybrid generation system was generated a stable outputs by spiral spring was continuously provided to load.

임플란트 지대주 삭제시의 발생열에 관한 연구 (A Study on the heat generation during implant abutment preparation)

  • 이호진;송광엽;장태엽
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.27-33
    • /
    • 2003
  • Excessive heat generation at the implant-bone interface may cause irreversible bone damage and loss of osseointegration. The effect of heat generation in vitro at the implant surface caused by abutment reduction with high-speed dental turbine was examined. Titanium-alloy abutments connected to a titanium alloy screw-implant embedded in an acrylic-resin block in a $37^{\circ}C$ water bath were prepared. Temperature changes were recorded via embedded thermocouples at the cervix and apex of the implant surface. Analysis of variance for repeated measures was used to compare seven treatment groups. Fifty seconds of continuous cutting with air and water coolant caused a mean temperature increase of $1.24^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $2.50^{\circ}C$ at apex and $1.64^{\circ}C$ at cervix. But, continuous cutting with air coolant caused a mean temperature increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Preparation of implant abutment does not lead to detrimental effect on peri-implant tissues provided that adequate cooling. However, without water cooling, extreme overheating could be provoked, reaching the critical temperature that would lead to irreversible bone damage within only a few seconds.

Supersonic Moist Air Flow with Condensation in a Wavy Wall Channel

  • Ahn, Hyung-Joon;Kwon, Soon-Bum
    • Journal of Mechanical Science and Technology
    • /
    • 제15권4호
    • /
    • pp.492-499
    • /
    • 2001
  • The characteristics of Prand시-Meyer expansion of supersonic flow with condensation along a wavy wall in a channel are investigated by means of experiments and numerical analyses. Experiments are carried out for the case of moist air flow in an intermittent indraft supersonic wind tunnel. The flow fields are visualized by a Schlieren system and the distributions of static pressure along the upper wavy wall are measured by a scanning valve system with pressure transducers. In numerical analyses, the distributions of streamlines, Mach lines, iso-pressure lines, and iso-mass fractions of liquid are obtained by the two-dimensional direct marching method of characteristics. The effects of stagnation temperature, absolute humidity, and attack angle of the upper wavy wall on the generation and the locations of generation and reflection of an oblique shock wave are clarified. Futhermore, it is confirmed that the wavy wall plays an important role in the generation of an oblique shock wave and that the effect of condensation on the flow fields is apparent.

  • PDF

열병합발전 아파트의 난방조절방식과 온열환경 (Thermal Environment and Heating Regulation System of the Co-Generation Apartment)

  • 윤정숙
    • 대한가정학회지
    • /
    • 제30권3호
    • /
    • pp.131-140
    • /
    • 1992
  • The purpose of this study was to investigate the heating regulation systems and the thermal environment of the Co-Generation apartment house in winter. Personal self-administration and interview method were used in the survey of this study. The respondents were 352 housewives who resided in Mokdong apartement using Co-Generation heating systems. Data was analyzed using SPSS PC+ computer package. The results of this study were summarised as follow; The typical patterns of heating regulation systems were intermittent and partial heating in the living room and bedroom exclusive of kitchen area. The present condition of the thermal environment were relatively warm in winter and Heatng regulation systems were influenced by type of location. Determinants of the thermal sensation and thermal comfort were the type of location of apartment as a architectural factor, clo as a personal factor.

  • PDF

Modified Differential Protection for Transformers in Wind Farms

  • George, Sujo P.;Ashok, S
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.78-88
    • /
    • 2018
  • The liberalization of electricity market and environmental concerns are the major driving forces for the development of Distributed Generation (DG). The mode of grid-connected wind power generation is becoming popular and has matured as a reliable DG technology. The voltage generated by the wind generator is stepped up to the higher voltage by the transformers before connecting to the grid. Operating algorithm of the differential relays for transformer protection used in the wind farms need to be modified to take care of the dynamic nature of fault current caused by the intermittent nature of the wind power. An algorithm for the differential relay is proposed in which dual slope characteristics are adjusted with varying fault level situation according to the wind generator in service as well as with the wind speed. A case study conducted for a typical wind farm shows that the proposed method avoids mal-operation of the differential relay in varying wind power conditions.

낙동강 소유역 경지에서의 비점오염원 물질 발생 및 배출 특성 (Generation and Discharge Characteristics of Non-point Pollutants from Farmlands of Small Watershed for Nak-dong River)

  • 정용준;남광현;민경석
    • 한국물환경학회지
    • /
    • 제20권4호
    • /
    • pp.333-338
    • /
    • 2004
  • This study was carried out to investigate the generation and discharge characteristics of non-point pollutants from farmlands in Nak-dong river basin. Annual unit generation load of nitrogen and phosphorus by fertilization in the test paddy field was almost similar to those calculated by the fertilization standards of district agricultural technology center, but it was extremely higher in case of the test dry field. By comparing annual total generation load of nutrients from fertilization to the data of fertilizer marketing, the accurate forecasting of generation load of pollutants was achieved by marketing data. The annual total discharge ratio of nutrients through infiltration and overflow from the farmland of the test paddy field were 9.5% and 1.1%, respectively, and those in the test dry field were 22.0% and 0.1%, respectively. The monthly discharge load of nutrients were shown the highest proportioned to the discharge load from lands, but it showed higher in phosphorus, which was caused by the intermittent discharge of phosphorus accumulated in drainage.