• Title/Summary/Keyword: Intermediate pressure

Search Result 273, Processing Time 0.029 seconds

An Experimental Study on the Optimal Intermediate Pressure of a 2-Stage Compression Heat Pump Using River Water (하천수 열원 2단압축 열펌프의 최적 중간압에 관한 실험적 연구)

  • Park, Cha-Sik;Jung, Tae-Hun;Joo, Young-Ju;Kim, Yong-Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.6
    • /
    • pp.333-339
    • /
    • 2009
  • The objective of this study is to predict optimal intermediate pressure of a 2-stage compression heat pump system using river water. To determine the maximum performance of the 2-stage compression heat pump system, the experimental evaluations on the 2-stage compression cycle were carried out under various operating conditions. Electronic expansion valves were applied to control intermediate pressure and superheat. Based on the experimental data, an empirical correlation for predicting optimal intermediate pressure which considering cycle operating parameters was developed. The present correlation was verified by comparing the predicted data with the measured data. The predictions showed a good agreement with the measured data within a relative deviation of ${\pm}4%$ at various operating conditions.

Performance Analysis of Simultaneous Heating & Cooling Water Making System(I)-Simulation (냉.온열 동시 제조시스템의 성능분석(I)-Simulation)

  • Park, Seong-Ryong;Park, Jun-Tack;An, Young-Hun
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.266-271
    • /
    • 2001
  • In this study, the performance of the simultaneous heating & cooling water making system using R134a was investigated by simulation. The most important effect upon heating COP was intermediate pressure depending on input water temperature. With the input water temperature of $10^{\circ}C\;and\;20^{\circ}C$, optimum intermediate pressure were 923 and 1040kPa, respectively. At that optimum intermediate pressure, the maximum heating COP of the system operated between $0^{\circ}C$ evaporating temperature and $70^{\circ}C$ condensing temperature were 4.15 and 3.83. With installation of the subcoolers in high or low pressure section, the system COP was increased by reducing the refrigerant mass flow rate. Under the optimum pressure and $10^{\circ}C$ input water temperature, it was found that heating COP was maximized when the low-subcooler and high-subcooler capacity rate were taken by 14% and 13%, respectively.

  • PDF

Wind pressure provisions for gable roofs of intermediate roof slope

  • Stathopoulos, Theodore;Wang, Kai;Wu, Hanqing
    • Wind and Structures
    • /
    • v.4 no.2
    • /
    • pp.119-130
    • /
    • 2001
  • The paper addresses the suitability of wind pressure coefficients specified in contemporary design standards and codes of practice for gable roofs of intermediate slope (roof angle $10^{\circ}-30^{\circ}$). In a recent research study, a series of low building models with different roof slopes in this intermediate range were tested in a boundary layer wind tunnel under simulated open country terrain conditions. This was different from the original study in the 70's, which produced the current provisions on the basis of a model tested only for a single roof slope (4:12) in this range. The results of the study suggest that a modification to the American wind provisions would be warranted to make them more representative of the true local and area-averaged wind loads imposed on gable roofs of intermediate slope.

Compression Power and Exergy Analysis in a Dry Ice Production Cycle with 3-stage Compression (3단압축 드라이아이스 제조사이클의 압축동력과 엑서지 해석)

  • 이근식
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.6
    • /
    • pp.550-560
    • /
    • 2000
  • In order to minimize compression power and analyze the cause of exergy loss for a dry ice production cycle with 3-stage compression, the variation of compression power was investigated and the exergy analysis was peformed for the cycle. In this cycle, $CO_2$, is used both as a refrigerant and as a raw material for dry ice. The behavior of compression power and irreversibility in the cycle were examined as a function of intermediate pressure. From this result, the conditions for the minimum compression power were obtained in terms of the first stage or the third stage pressure. In addition, the irreversibilities for the cycle were investigated with respect to the efficiency of compressor. Result shows that the optimum pressure is not consistent with the conventional pressure obtained from the equal-pressure-ratio assumption. This is mainly due to the change in mass flow rate of the intermediate stage compressor by the flash gas evaporation from the flash drums. Most important is that the present exergy analysis enabled us to find bad performance components for the cycle and informed us of methods to improve the cycle performance.

  • PDF

Comparisons of Foot Pressure Patterns between Experienced Skiers and Intermediate Skiers during Alpine Skiing (알파인 스킹 시 상급 스키어와 중급 스키어 간의 족저압력 패턴 비교)

  • Kim, Joo-Nyeon;Yoo, Si-Hyun;Ha, Sung-He;Kim, Jin-Hae;Ryu, Ji-Seon;Park, Sang-Kyoon;Yoon, Suk-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.1
    • /
    • pp.19-26
    • /
    • 2014
  • This study investigated foot pressure patterns between experienced skiers and intermediate skiers during alpine skiing. Five experienced skiers and five intermediate skiers participated in this study. Foot pressure measurement system was used to measure vertical ground reaction force (vGRF) and contact area under the six plantar regions. Each participant was asked to perform basic parallel turns and carved turns on a $18^{\circ}$ groomed slope. Each right turn was divided into the initiation phase, the steering phase 1 and 2. For the initiation phase of the basic parallel turns, significantly greater contact area was found on the LRF and RRF of the intermediate skiers (p<.05) and significantly greater vGRF was found on the LRF of the intermediate skiers (p<.05). Also significantly greater vGRF and contact area were found on the LRF and RRF of the intermediate skiers at the steering phase 1 (p<.05) and on the LRF of the intermediate skiers at the steering phase 2 (p<.05). For the carved turns, significantly greater vGRF and contact area were found on the LRF and RRF of the intermediate skiers at all three phase (p<.05). On the other hand, significantly greater vGRF was found on the RFF of the experienced skiers at the steering phase 1 (p<.05). Also significantly greater vGRF and contact area were found on the RMF of the experienced skiers at the steering phase 2 (p<.05). In order to increase performance, we suggest that the intermediate skiers should be unweighted at the initiation phase and shift the body weight to the forefoot of the outer foot at the steering phase 1. Also, the outer ski should be loaded more than the both skis at the steering phase 1 and 2.

Design Characteristics Analysis for Very High Temperature Reactor Components (VHTR 초고온기기 설계특성 분석)

  • Kim, Yong Wan;Kim, Eung Seon
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.85-92
    • /
    • 2016
  • The operating temperature of VHTR components is much higher than that of conventional PWR due to high core outlet temperature of VHTR. Material requirements and technical issues of VHTR reactor components which are mainly dominated by high temperature service condition were discussed. The codification effort for high temperature material and design methodology are explained. The design class for VHTR components are classified as class A or B according to the recent ASME high temperature reactor design code. A separation of thermal boundary and pressure boundary is used for VHTR components as an elevated design solution. Key design characteristics for reactor pressure vessel, control rod, reactor internals, graphite reflector, circulator and intermediate heat exchanger were analysed. Thermo-mechanical analysis of the process heat exchanger, which was manufactured for test, is presented as an analysis example.

Determination of Cadmium, Chromium and Lead in Polymers by ICP-OES Using a High Pressure Asher (HPA)

  • Cho, Hong-Je;Myung, Seung-Woon
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.489-497
    • /
    • 2011
  • The proposed method for an effective assay of Cd, Cr and Pb in several polymer samples has been validated. The determination was carried out using ICP-OES after a high pressure asher (HPA) digestion at pressure and temperatures up to 13 MPa and $320^{\circ}C$, respectively. Polymer based materials were totally oxidized with nitric acid in a HPA chamber and determined by ICP-OES. Validation parameters such as linearity, matrix effect, limit of dectection (LOD), limit of quantitation (LOQ), accuracy and precision (repeatibility, intermediate precision and reproducibility) were assessed. The LOD and LOQ in the sample were ranged from 0.98 to 1.18 mg $kg^{-1}$ and 2.93 to 3.55 mg $kg^{-1}$, respectively, relying on the analyte. The proposed method had a good accuracy and precision for repeatability, intermediate precision with respect to days and analysts and reproducibility expressed as inter-laboratory study. The developed method was simple to use, suitable and applicable to various kinds of polymers.

Evaluation of High Temperature Structural Integrity of Intermediate Heat Exchanger in a Steady State Condition for PGSFR (PGSFR중간열교환기의 정상상태 고온 구조 건전성 평가)

  • Lee, Seong-Hyeon;Koo, Gyeong-Hoi;Kim, Sung-Kyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.12 no.1
    • /
    • pp.107-114
    • /
    • 2016
  • Four cylindrically shaped IHXs(Intermediate Heat Exchangers) are installed in the PHTS(Primary Heat Transfer System) of the PGSFR(Prototype Gen IV Sodium cooled Fast Reactor). As for the IHX, the temperature difference of structure is inevitable result caused by heat transfer between primary coolant sodium and IHTS(Intermediate Heat Transport System) sodium. It is necessary to evaluate the high temperature structural integrity of IHXs which operate at the elevated temperature condition over the creep temperature. In this paper, the high temperature structural integrity of IHX under assumed loading conditions has been reviewed according to ASME code.

Optimal Intermediate Process Design in Forging by Genetic Algorithm (유전 알고리즘을 이용한 단조공정중 중간 공정 최적설계)

  • 정제숙;황상무
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1997.03a
    • /
    • pp.155-158
    • /
    • 1997
  • The investigation deals with of a intermediate process condition hving a bolt-shaped final product where it is required to extend tool-life in forging. In this study, optimization of the design variables is conducted by a genetic algorithm, where the fitness values are evaluated on the basis of FEM analysis model. The approach is applied to the determination of the intermediate process conditions which are optimal with regard to minimization of peak die pressure.

  • PDF

Performance Evaluation of a Two-Stage Compression Heat Pump System for District Heating (지역난방용 2단 압축 히트펌프 시스템 성능평가)

  • Park, Cha-Sik;Cha, Dong-An;Kwon, Oh-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.7
    • /
    • pp.585-590
    • /
    • 2012
  • The objective of this study is to investigate the performance of a two-stage compression heat pump system for district heating. The experimental setup of heat pump consists of compressor, condenser, evaporator, expansion device, intercooler, flash tank, oil separator and accumulator. The experimental evaluations on the two-stage compression cycle were carried out under various operating conditions which were heat source temperature, the degree of compressor inlet superheat, and intermediate pressure. The temperature ranges of unutilized energy as the heat source were used in the test conditions. As the heat source temperature increased from $10^{\circ}C$ to $30^{\circ}C$, the COP and heating capacity of the heat pump system increased by 22.6% and 45.8%, respectively. The performance of the two-stage heat pump system increased by 5.2% with the variation of the intermediate pressure in the same heat source temperature conditions.