• Title/Summary/Keyword: Interior Temperature

Search Result 487, Processing Time 0.026 seconds

University Students' Housing Satisfaction of the University Dormitory - Focusing on the Gwangju & Chonnam Area - (대학생의 기숙사 실내공간에 대한 주거만족도 - 광주.전남지역을 중심으로 -)

  • Kim, Mi-Hee;Oh, Ji-Young
    • Journal of the Korean housing association
    • /
    • v.19 no.6
    • /
    • pp.145-155
    • /
    • 2008
  • This study examined the actual use and users‘ satisfaction with the university dormitories in Gwangju and Chonnam and analyse the related variables that affect on them. Self-administered questionnaires were provided to 200 university students from Gwangju and the Chonnam area. The collected data was used to conduct comparative and descriptive statistical analysis: T-test Below are the study findings. Female students express more satisfaction with community affinity than male students in the satisfaction about socio-psychological environment. Students residing in the rooms for 2 persons express more satisfaction with the division of private space with common space, study appropriateness etc. than those residing in the rooms for 4 persons. Students residing in the cluster-type rooms express more satisfaction with the division of private space with common spaces study appropriateness and relationship with other students in other rooms etc. In relation to the room environment, female students express less dissatisfaction with the noise than male students. Students residing in the rooms for 2 persons express more satisfaction with the room size, interior temperature pleasantness, brightness etc. than those residing the in rooms for 4 persons. Students residing in the cluster-type rooms express more satisfaction with the bed size, the condition of interior finishing, interior temperature pleasantness, brightness and interior air pleasantness etc. than those residing in unit-rooms. In relation to common using environment, male students express more satisfaction with the library than female students. And students residing in the rooms for 4 persons and those residing in the cluster-type rooms express more satisfaction with lounge than those residing in the rooms for 2 persons and those residing in the unit-rooms. Organizing the university domitory planning according to the students' demands, based on this study, the change to general function of domitory in sleeping, studying, leisure activity and culture acitivity is needed. Interior environment technical factor of interior air pleasantness and noise should be improved.

Influence of Interior Design Elements on Spatial Satisfaction and Preference for Coffeeshop Space (커피전문점의 실내디자인 요소 변화에 따른 공간 만족도 분석)

  • Choi, You-Jin;Lee, Ji-Hyun;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.4
    • /
    • pp.364-375
    • /
    • 2012
  • This study investigates the effects of interior design elements on the satisfaction and preference for space. Field measurements and surveys were conducted in three coffeeshops where various interior design elements were applied. Results indicate that movable tables and chairs for two people were preferred in the space. They need to be placed flexibly according to the visitors' needs to improve satisfaction for convenience. To improve spatial satisfaction, the brightness of color applied to wall surfaces was recommended to be lower than that of color used for floor surfaces. The surfaces of space and interior design elements such as furniture also need to be kept clean. Lamps with lower color temperature were effective to enhance spatial satisfaction. Light sources should be shielded when a pendant lighting system with general diffuse type was used in space. Natural daylight through window was also required for better satisfaction level. Multiple linear regression implied that the cozy feeling by electric light, existence of daylight, flexible layouts for tables and chairs, color and quality of material for tables and floor were significant contributors to overall spatial satisfaction.

High Temperature Gas Nitriding of Fe-20Mn-12Cr-1Cu Damping Alloy (Fe-20Mn-12Cr-1Cu 제진합금의 고온가스 질화처리)

  • Sung, Jee-Hyun;Kim, Yeong-Hee;Sung, Jang-Hyun;Kang, Chang-Yong
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.26 no.3
    • /
    • pp.105-112
    • /
    • 2013
  • The microstructural changes of Fe-20Mn-12Cr-1Cu alloy have been studied during high temperature gas nitriding (HTGN) at the range of $1000^{\circ}C{\sim}1150^{\circ}C$ in an atmosphere of nitrogen gas. The mixed microstructure of austenite and ${\varepsilon}$-martensite of as-received alloy was changed to austenite single phase after HTGN treatment at the nitrogen-permeated surface layer, however the interior region that was not affected nitrogen permeation remained the structure of austenite and ${\varepsilon}$-martensite. With raising the HTGN treatment temperature, the concentration and permeation depth of nitrogen, which is known as the austenite stabilizing element, were increased. Accordingly, the depth of austenite single phase region was increased. The outmost surface of HTGN treated alloy at $1000^{\circ}C$ appeared Cr nitride. And this was in good agreement with the thermodynamically calculated phase diagram. The grain growth was delayed after HTGN treatment temperature ranges of $1000^{\circ}C{\sim}1100^{\circ}C$ due to the grain boundary precipitates. For the HTGN treatment temperature of $1150^{\circ}C$, the fine grain region was shown at the near surface due to the grain boundary precipitates, however, owing to the depletion of grain boundary precipitates, coarse grain was appeared at the depth far from the surface. This depletion may come from the strong affinity between nitrogen and substitutional element of Al and Ti leading the diffusion of these elements from interior to surface. Because of the nitrogen dissolution at the nitrogen-permeated surface layer by HTGN treatment, the surface hardness was increased above 150 Hv compared to the interior region that was consisted with the mixed microstructure of austenite and ${\varepsilon}$-martensite.

Variation of Spatial Cognition According to Visual Perception and Psychological Responses for Lighting Environments in Rest Space (휴게실 공간의 조명환경에 대한 시각적 감지 및 심리적 반응에 따른 공간 인지도 변화)

  • Kim, Jae-Sang;Lee, Ji-Hyun;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.5
    • /
    • pp.443-453
    • /
    • 2012
  • This study examines visual perception and spatial satisfaction according to lighting conditions. Field measurements and surveys were performed in three rest space of university buildings where various lighting conditions were employed. Results indicate that overall impression of space improved when low color temperature, such as 3,000 K governed overall lighting environment and accent lighting was used for wall surfaces. Lighting conditions that kept uniform illuminance levels using area light sources containing fluorescent lamps with 6,500 K failed to keep favorable spatial satisfaction for space. High color temperature was not recommended for lighting in rest space. Asymmetrical illuminance levels formed by low color temperature such as 3000 K is recommended to keep positive mood and improve spatial satisfaction in rest space. Overall impression of the space was influenced by visual comfort, color temperature, spatial satisfaction and brightness. Spatial satisfaction for space was effectively impacted by psychological comfort, color temperature and overall impression for lighting conditions. Psychological comfort in space was influenced by color temperature, spatial satisfaction and visual annoyance from reflected light.

A Study on the Oxygen Index of Interior Wallpapers at Elevated Temperature (실내 내장 벽지의 고온산소지수에 대한 연구)

  • Oh, Kyu-Hyung;Lee, Sung-Eun;Kim, Hwang-Jin
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.57-62
    • /
    • 2008
  • Most of all the Korean home use a wallpaper as a decoration and finishing of interior. One of the fire spread factor in a house is a combustion of wall paper. There were some research concerning oxygen index in a ambient temperature. The purpose of this study is to investigate the difference of oxygen index of a wallpaper between ambient and high temperature and a effect on the fire spreading. Based on the result, the difference of oxygen index between ambient temperature and high temperature showed $5{\sim}8%$. Difference of 0.1% of oxygen index show big differences in combustion length of sample. Therefore, it was found that the decrease of oxygen index at elevated temperature is a important factor in fire spread.

Analysis on Visual Perception and Mood for Color of Light in a Small Office (소규모 사무실의 조명 색 변화에 따른 시각적 감지 및 무드 변화 분석)

  • Kang, Min-Hye;Kim, Soo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.4
    • /
    • pp.287-296
    • /
    • 2011
  • This study examines the influences of correlated color temperature and illuminance on visual perception and temporary mood sensation in a small office. Field measurements and surveys were conducted in a full-scale mock-up model. Twenty subjects participated in the survey under six lighting conditions formed by three color temperature and two illuminance levels. Results indicate that 4000 K color temperature was effective to mitigate glare sensation from light source. Lamps with low color temperature such as 2700 K was not recommended for office lighting since they are likely to caused glare and visual discomfort. Preferred color temperature was 4000 K and 6500 K for 750 lx and 500 lx target illuminance respectively. The increase of illuminance was not an effective contributor to improve mood perception. The illuminance should be lower than 500 lx to achieve good mood, but the illuminance level in office space should be considered with visual performance simultaneously. This study suggests that fluorescent lighting fixtures with 4000 K lamps would be usefully used for office lighting since they formed friendly conditions for better visual performance.

The Effect of Casting Conditions on Shrinkage and Porosity of A356.2 Alloys (A356.2 합금의 수축과 기공에 미치는 주조 조건의 영향)

  • Jeon, Gyu-Tae;Kim, Ki-Young;Kim, Suk-Jun
    • Journal of Korea Foundry Society
    • /
    • v.37 no.6
    • /
    • pp.193-198
    • /
    • 2017
  • In this study, volumes of shrinkage and porosity of A356.2 alloys during casting were analyzed as a function of melt temperature, pouring diameter, mold temperature, and Sr content. The temperature of the melt barely affected the shrinkage and porosity formation. The pouring diameter determined the pouring rate, and it was proportional to the shrinkage, yet no relationships with the density of porosity were observed. When the mold was heated at $400^{\circ}C$, shrinkage and porosity in the alloy increased above the one in the mold without heating. However, the mold without heating experienced interior shrinkage and the porosity was mainly distributed near interior shrinkage. The addition of Sr to the melt resulted in more shrinkage and less porosity.

NUMERICAL ANALYSIS OF THERMAL FLOW OF CABIN INTERIOR AND DE-ICING ON AUTOMOBILE GLASS (자동차 내부 열유동해석 및 전방유리면의 해빙 전산해석)

  • Song D. W.;Park W. G.;Jang K. L.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.75-80
    • /
    • 2005
  • The present work was undertaken to numerically analyze the defrosting phenomena of windshield glass. In order to analysis the phase change from frost to water on windshield glass by discharging hot air from a defroster nozzle, the flow and the temperature field of the cabin interior, the heat transfer through the windshield glass, and the phase change of frost should be solve simultaneously. In the present work, the flow field was obtained by solving 3-D incompressible Navier-Stokes equations, and the temperature field was computed from the incompressible energy equation. The phase change process was solved by the enthalpy method. For the code validation, the temperature and the phase change of the driven cavity were calculated. The calculation showed a good agreement with other numerical results. Then, the present code was applied to the defrosting problem of a real automobile, and a good agreement with the experimental data was also obtained.

  • PDF

Comparison of combustion gas release for FRP and seat cover materials to the Furnace temperature (연소온도 조건에 따른 FRP 및 시트커버 내장재의 연소가스 발생량 비교)

  • Lee, Duck-Hee;Jung, Woo-Sung;Lee, Cheul-Kyu;Yu, Mun-Chun
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.1527-1532
    • /
    • 2007
  • We have evaluated the toxicity of interior materials for the railway passenger car by checking the release of $CO_2$, CO, NOx, SO2, HCl, HF, HBr, HCN. The NOx is one of the most effective for the determination of Toxic Index R value. It is generally known that the mechanism of thermal NOx generation without the Interior Material nitrogen source. This study started from the idea to check the NOx difference according to the furnace temperature. But from the results, it was revealed that NOx is not so sensitive for the furnace temperature in case of solid burning. Other gases such as HCN, CO were more changeable to the furnace Temp. We reported the test result as for toxicity index r(x).

  • PDF

Rotating Flows in a Circular Cylinder with Unstable Stratification (불안정 성층화를 가진 원통형 용기 내의 회전유동에 관한 연구)

  • Kim, Jae-Won
    • Journal of computational fluids engineering
    • /
    • v.3 no.2
    • /
    • pp.27-38
    • /
    • 1998
  • Rotating flow of a stratified fluid contained in a circular cylinder with unstable temperature gradient imposed on the side wall of it has been numerically studied. The temperatures at the endwall disks are constant. The top disk of the container is coider than that of the bottob disk, as much as the temperature difference n${\Delta}$T, (0${\leq}$n${\leq}$3). Flows in the vessel are driven by an impulsive rotation of the hot bottom disk with respect to the central axis of the cylinder. Flow details have been acquired. For this flow, the principal balance in the interior core is characterized by a relationship between the radial temperature gradient and the vertical shear in the azimuthal velocity. As the buoyancy effect becomes appreciable, larger portions of the meridional fluid transport are long-circuit from the bottom disk to the interior region via the side wall.

  • PDF