• Title/Summary/Keyword: Interior Temperature

Search Result 487, Processing Time 0.026 seconds

A Study on the Imfluence of the Pipe Line of Boiler for Flame Distribution of Combustion Furnace (연소로의 화염분포가 보일러 관로에 미치는 영향에 관한 연구)

  • Cho, Dong-Hyun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.6
    • /
    • pp.1435-1441
    • /
    • 2014
  • The fire took place in the synthetic heat transfer fluid boiler used in production process of medium density fiberboard. This study investigated pressure distribution of the first, second and third passes and the temperature in the fire burner. The boiler's internal fluid is unsteady due to the out of order inverter. As the operation continues, the flame's flow and speed are unsteady. The synthetic heat transfer fluid leak spouted about 120kg/min in the form of vapor in the early period of the fire. The flame extended to the second and third passes. The highest temperature of the second and third pass is $1059^{\circ}C$ and $1007^{\circ}C$, respectively. The synthetic heat transfer fluid spouted through the cracked part of the fire box in the first pass and accumulated on the turn table. Therefore, it is expected that the temperature of the interior of the fire box is above $1200^{\circ}C$. The temperature of the burner rises to a maximum level several times in a short period. On account of that, several explosions occur in the fire burner. Pressure distribution at steady state in combustion furnace is 2~5mAq and pressure distribution at inverter under fault condition in combustion furnace is 10~-53mAq. The decrement of coil thickness measurement for synthetic heat transfer fluid boiler is 0~5mm.

Edge effects confirmed at the clear-cut area of Korean red pine forest in Uljin, eastern Korea

  • Jung, Song Hie;Lim, Chi Hong;Kim, A Reum;Woo, Dong Min;Kwon, Hye Jin;Cho, Yong Chan;Lee, Chang Seok
    • Journal of Ecology and Environment
    • /
    • v.41 no.10
    • /
    • pp.290-301
    • /
    • 2017
  • Background: Forest edges create distinctive ecological space as adjacent constituents, which distinguish between different ecosystems or land use types. These edges are made by anthropogenic or natural disturbance and affects both abiotic and biotic factors gradually. This study was carried out to assess edge effects on disturbed landscape at the pine-dominated clear-cut area in a genetic resources reserve in Uljin-gun, eastern Korea. This study aims to estimate the distance of edge influence by analyzing changes of abiotic and biotic factors along the distance from forest edge. Further, we recommend forest management strategy for sustaining healthy forest landscapes by reducing effects of deforestation. Results: Distance of edge effect based on the abiotic factors varied from 8.2 to 33.0 m. The distances were the longest in $Mg^{2+}$ content and total nitrogen, $K^+$, $Ca^{2+}$ contents, canopy openness, light intensity, air humidity, $Na^+$ content, and soil temperature followed. The result based on biotic factors varied from 6.8 to 29.5 m, coverage of tree species in the herb layer showed the longest distance and coverage of shrub plant in the herb layer, evenness, species diversity, total coverage of herb layer, and species richness followed. As the result of calculation of edge effect by synthesizing 26 factors measured in this study, the effect was shown from 11.0 m of the forest interior to 22.4 m of the open space. In the result of stand ordination, Rhododendron mucronulatum, R. schlippenbachii, and Fraxinus sieboldiana dominated arrangement of forest interior sites and Quercus mongolica, Vitis amurensis, and Rubus crataegifolius dominated spatial distribution of the open area plots. Conclusions: Forest interior habitat lies within the influence of both abiotic and biotic edge effects. Therefore, we need a forest management strategy to sustain the stability of the plant and further animal communities that depend on its stable conditions. For protecting forest interior, we recommend selective logging as a harvesting method for minimizing edge effects by anthropogenic disturbance. In fact, it was known that selective logging contributes to control light availability and wind regime, which are key factors affecting microclimate. In addition, ecological restoration applying protective planting for the remaining forest in the clear-cut area could contribute to prevent continuous disturbance in forest interior.

A Study on hospital color plan by color sensibility palette - Korea University Guro hospital new building in the object (색채 감성 팔레트를 이용한 병원의 색채계획 연구 - 고려대학교 구로병원 신사옥을 대상으로 -)

  • Moon, Eun-Bae
    • Korean Institute of Interior Design Journal
    • /
    • v.16 no.2 s.61
    • /
    • pp.295-302
    • /
    • 2007
  • The use of colors plays an important role in the field of space design. The selection of proper colors influences on people who use space by making the most of the psychological and physical functions of colors. Especially, the medical space is relatively more important than other indoor spaces in the selection of colors. The medical space has to be something to do with diversity and functions, and at the same time with stability and quietude, as well as the space with general convenient facilities. Color is not only related to the expression but also to the distinction of things and the existence. It also functions as a visual language. Human beings depend heavily on the function of color as a visual language. According to previous studies, human beings depend on color by 80% of the whole range of eyesight. Thus, color is an important factor in recognizing things and space. For example, in hospital, it Is very important to apply proper colors to various medical treatment spaces for the sake of patients' rest and healing. Various colors which do not consider the function of patients' rest and healing may make the space confusing against the change of space and structure. It is also important to apply colors to the change of space and structure. Another key point that I would like to make is that color has visual, direct and physical influence on the human body. For example, the color red with long wavelength serves to regulate body temperature. Research on the color scheme for hospitals should consider both physical and psychological factors. That is why the research should be carried out in depth through continuous clinical demonstration. The present research aims to outline color planning.

Analysis of Hygrothermal Performance of Wood Frame Walls according to Position of Insulation and Climate Conditions

  • Kang, Yujin;Chang, Seong Jin;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.2
    • /
    • pp.264-273
    • /
    • 2016
  • The insulation of a building envelope influences the hygrothermal performance as well as the thermal performance of the building. While most of Korean wood frame houses have an interior insulation system, the exterior insulation system with high thermal performance has recently been applied. While it can be effective in energy savings for better insulation performance, without consideration of the moisture, condensation and mould growth can occur. Therefore, in this study, hygrothermal behaviour, water content, and mould growth were analyzed using hygrothermal simulation of an exterior wall of a wood frame house with which the interior insulation and exterior insulation systems were applied. The wall layer included Wall A (Interior insulation) and Wall B (Exterior insulation). The U-values were identified as 0.173 and $0.157W/m^2K$, respectively. The total water content and OSB absolute water content of Wall A were confirmed to be higher than those of Wall B, but the absolute water content did not exceed the reference value of 20%. The moisture content of the two walls was determined to be stable in the selected areas. However, mould growth risk analysis confirmed that both Wall A and Wall B were at risk of mould growth. It was confirmed that as the indoor setting temperature decreased, the mould index and growth rate in the same area increased. Therefore, the mould growth risk was affected more by indoor and outdoor climate conditions than by the position of the insulation. Consequently, the thermal performance of Wall B was superior to that of Wall A but the hygrothermal performances were confirmed to be similar.

A Study on Relations between Deterioration of Physical Functions due to Aging and Bathroom Design Guidelines for the Elderly (노화로 인한 신체적 기능 쇠퇴와 고령자를 위한 욕실 디자인 가이드라인 관계 연구)

  • Lee, Yeun-Sook;Lim, Hyun-Jin;Lee, Ji-Hye;Ahn, Chang-Houn
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.5
    • /
    • pp.188-198
    • /
    • 2013
  • Advancement toward aging society has presented the importance of house planning in consideration of the elderly, increasing the necessity of such planning. Therefore the importance of indoor design guideline for elderly houses has been stressed and the understanding of the aging in regard to this trend will create more mature spaces. In line with this trend the purpose of this study is to study the medical factors related with bathroom interior design guidelines of the existing elderly houses from the viewpoint of deteriorating physical functions due to aging process. In order to research the deterioration of physical functions due to aging literatures of medical and exercise physiology were used and concerning the existing bathroom design guidelines for the aged people, the guideline items of behavior facilitation, physiological maintenance and perceptual maintenance aspects out of Murtha & Lee's user benefit criteria(1976) related with physical functions were selected to research in relation with the knowledge about the deterioration phenomena of physical functions. Physical aging and deterioration aspects were classified from the viewpoint of musculoskeletal disorder, cardiovascular disorder, respiratory disorder, gastronomy disorder, urology disorder, somatosensory disorder, endocrine disorder, immune disorder, nervous disorder and skin diseases and these were utilized in interpreting total 100 items of bathroom design guideline. Because bathroom is the space where many physical movements are done, it had the closest relationship with the deterioration of musculoskeletal health in general and as bathroom is the space where people use water and feel the difference in temperature and moisture more than other spaces, deterioration of skin and somatosensory health had the next closest relationship. The result of this study revealed that regarding the deterioration of physical functions of the elderly people in aspect of their perceptibility as designers will design creatively and sincerely based on its relationship with nervous system in future, the result of this study will be used to develop better spatial designs efficiently to meet for the aging society.

Effect of Increased Oxygen Content due to Intensive Milling on Phase and Microstructural Development of Silicon Nitride

  • Kim, Hai-Doo;Ellen Y. Sun;Paul F. Becher;Kim, Hyo-Jong;Han, Byung-Dong;Park, Dong-Soo
    • Journal of the Korean Ceramic Society
    • /
    • v.38 no.5
    • /
    • pp.405-411
    • /
    • 2001
  • Compacts of a mixture of fine $\alpha$-Si$_3$N$_4$powders, 6% $Y_2$O$_3$and 1% $Al_2$O$_3$were attrition milled time on phase and microstructural development in silicon nitride ceramics. The sintered surface and the interior showed different behaviors in phase and microstructral developments. Increased oxygen content with increased milling time of powder mixture leads to the formation of Si$_2$$N_2$O phase at temperatures as low as 155$0^{\circ}C$. Si$_2$$N_2$O is stable in the interior of the samples but unstable in the surface region of the specimen sintered at higher temperature. This results in a duplex structure where the interior consists of Si$_2$$N_2$O grains dispersed in $\beta$-Si$_3$N$_4$matrix and a surface which contains only $\beta$-Si$_3$N$_4$. The alpha to beta phase transformation and the microstructural development are shown to be influenced by the formation and decomposition of the Si$_2$$N_2$O.

  • PDF

Development of Intelligence comfortable Air Handling System Based on LonWorks (LonWorks 기반의 지능형 쾌적 공조 시스템 개발)

  • Kim, Gwan-hyung;Kang, Sung-in;Hwang, Yeong-yeun;Byun, Gi-sig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.273-275
    • /
    • 2009
  • In recent years, many home machines have been developed in order to design and control comfortable interior inside houses. For such task, important factors are temperature, natural and interior lights, and space and control of relative factors each other. This paper presents novel sensor module inside houses, which is designed based on these factors through the PMV (Predicted Mean Vote) standard using information about home state. Moreover, LonWorks based power line communication technique is utilized for control interior lights and air-conditioners by means of wireless remote controllers. This mechanism is systemically operated via intelligent control framework.

  • PDF

The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment (기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구)

  • Kim, Seohoon;Kim, Jonghun;Yoo, Seunghwan;Jeong, Hakgeun;Song, Kyoodong
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.

Decay Rate of the Nitrogen Dioxide in Indoor Residence Using Mass Balance Model (물질수지 모델을 이용한 주택 실내의 이산화질소 감소율)

  • 유승진;배현주;양원호;정문호
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.2
    • /
    • pp.145-152
    • /
    • 2001
  • The purpose of this study was to determine nitrogen dioxide(NO$_2$) decay rate by reaction between NO$_2$ and interior materials in Korean residence. The results of this research could be helpful to choose the interior construction materials and to study on reduction of indoor air pollutants. The results of this research are as follows; For 30 residences in Seoul and Incheon from October 2000 to march 2001, the mean of infiltration rate was 0.70$\pm$0.44 ACH, and single-detached houses (7 houses) and apartments (19 houses) were 0.97$\pm$0.55 ACH and 0.61$\pm$0.34 ACH, respectively. The $CO_2$ decay followed approximately first-order process ($R^2$=0.97$\pm$0.02). There existed a statistic significance in filtration rate between houses built in 1980’s and built in 1990’s by t-test (p<0.02). Mean of NO$_2$ decay rates in 26 residence3s except 4 residences was 0.94$\pm$0.49hr$^{-1}$ , and also 0.86$\pm$0.49hr$^{-1}$ , 0.97$\pm$0.50hr$^{-1}$ in single-detached houses and apartments, respectively. Mean NO$_2$ decay rates in houses built in 1980’s were 0.78$\pm$0.37hr$^{-1}$ , 1.33$\pm$1.03hr$^{-1}$ , respectively. Nothing were showed statistical significance among indoor temperature, indoor humidity, and NO$_2$ decay rate. However, NO$_2$ decay rates had a tendency to increase by increase of temperature and humidity. Average volume/surface of participated houses was 0.55$\pm$0.07m and mean NO$_2$ deposition velocity was calculated as 1.46$\pm$0.59msec$^{-1}$ .

  • PDF

Implementation of Smart Control System based on Intelligent Dimming with LEDs

  • Lee, Geum-Boon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.5
    • /
    • pp.127-133
    • /
    • 2016
  • In this paper, an intelligent dimming control system is designed and implemented with the human visual response function using CDS sensor, PIR sensor and temperature sensor, etc. The proposed system is designed to detect a moving object by PIR sensor and to control the LED dimming considering the human visual response. Also, the dimming of LED light can modulate on the app, and simultaneously control dimming in real-world environments with smart phone app. A high-temperature warning or a fire hazard information is transmitted to user's smart phone according to sensor values and Data graph are provided as part of data visualization. Connecting the hardware controller, the proposed intelligent smart dimming control system is expected to contribute to the power reduction interior LED, smart grid building and saving home combining with internet of things.