• Title/Summary/Keyword: Interference temperature

Search Result 315, Processing Time 0.025 seconds

The Development of Electric Ballast for a Instant Start/Restart of Metalhalide Lamp (메탈핼라이드램프용 순시점등/재점등 전자식안정기 개발)

  • Kim, Su-Kyoung;Jang, Woo-Jin
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.9-15
    • /
    • 2004
  • The most shortcoming of metalhalide lamps is what the instant restarting cannot be realized when the arc tube is in the hot condition. The discharge starting voltage of arc tube in the hot condition is much higher than in the cold condition. Therefore it takes about five minutes to restart the metalhalide lamps, that is to say, it is possible to start when the pressure and the temperature are decreased. But, if the lamp is restarted in the hot condition, we must supply the high voltage pulse with 20[kV] at the both electrode of lamp. The proposed electronic ballast is consist of a electromagnetic interference(EMI) filter, a power factor correction(PFC) circuit, a flyback converter, a half-bridge inverter, and a high voltage igniter circuit. By this composition we can start/restart the lamp with the voltage 20[kV], even if the lamp is in the hot condition.

Development of an ACL Anchor: Effects of the Design Parameters on the Performance of a New Anterior Cruciate Ligament Fixation Device

  • Kim, Jong-Dae;Oh, Chae-Youn;Kim, Cheol-Sang
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.132-138
    • /
    • 2008
  • We investigated the biomechanical properties of a newly designed self-expansion type anterior cruciate ligament (ACL) anchor. The ACL anchor consists of the ring section giving the elastic force, the wedge for maintaining in contact with the femur tunnel wall and the link suspending hamstring graft or artificial ligament. The main design parameters that determine the performance of this device were the expansion angle (${\theta}$) and the thickness ($t_R$). The Ti6Al4V anchors were heated after inserting in a jig for 1 hour at $800^{\circ}C$ in a protective argon gas atmosphere and allowed to cool to room temperature in the furnace. In order to investigate the influence of the expansion angle and the thickness of the ring on the biomechanical properties of the anchor, the maximum pull-out load, stiffness and slippage of the ACL anchor were measured using the pull-out tester, and statistical analyses were also executed. The present results showed that the design parameters gave a significant effect on the performance of the self- expansion type of anchor. The pull-out load of the ACL anchors significantly increased as the thickness of the ring section was increased, having a similar trend for both expansion angles. The ACL anchor showed about 2.5 times higher values of the pull-out load than that of the minimum load (500N)required for the "accelerated rehabilitation". The optimum ${\theta}$ and $t_R$ values of this ACL anchor were suggested to have sufficient resistance against the pull-out force, high stiffness and relatively low slippage after ACL reconstruction.

Formation and Chemical Leaching of a Non-Equilibrium Al(Fe-Cu) Alloy Powder produced by Rod-Milling (Rod Milling에 의해 제작된 비평형 Al(Fe-Cu) 합금 분말의 형성 및 Chemical Leaching)

  • 김현구;명화남
    • Journal of Powder Materials
    • /
    • v.9 no.5
    • /
    • pp.359-364
    • /
    • 2002
  • We report the structure, thermal and magnetic properties of a non-equilibrium $Al_{0.6}(Fe_{50}Cu_{50})_{0.4}$ alloy powder produced by rod milling and chemical leaching. An X-ray diffractometry(XRD), a transmission electron microscope(TEM), a differential scanning calorimeter(DSC), a vibrating sample magnetometer(VSM), and superconducting quantum interference device(SQUID) were utilized to characterize the as-milled and leaching specimens. The crystallite size reached a value of about 8.82 nm. In the DSC experiment, the peak temperatures and crystallization temperatures decreased with increasing milling time. The activation energy of crystallization is 200.5 kJ/mole for as-milled alloy powder. The intensities of the XRD peaks of as-milled powders associated with the bcc type $Al_{0.5}Fe_{0.5}$ structure formative at $350^{\circ}C$ sharply increase with increasing annealing temperature. Above $400^{\circ}C$, peaks alloted to $Al_{0.5}Fe_{0.5}$ and $Al_{5}Fe_{2}$ are observed. After annealing at $600^{\circ}C$ for 1h, the leached Ll specimen transformed into bcc $\alpha$-Fe and fcc Cu phases, accompanied by a change in the structural and magnetic properties. The saturation magnetization decreased with increasing milling time, and a value of about 8.42 emu/g was reached at 500 h of milling. The coercivity reached a maximum value of about 142.7 Oe after 500 h of milling. The magnetization of leached specimens as function of fields were higher at 5 K, and increased more sharply at 5 K than at 100 K.

A study on the cause Analysis and solution of an overheated NGR of the Main Transformer (변압기 중성점 접지리액터 과열원인분석 및 해소방안에 관한 연구)

  • Park, Gil-Soo;Park, Soo-Hong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.2
    • /
    • pp.262-267
    • /
    • 2011
  • In the power system, the transformer's neutral earth reactor line 1 grounding failure may occur. By limiting the magnitude of the failure grounding current flow, it will aid to reduce the failure of the transformer. Consequently, this also may avoid the failure of the disconnection of the industrial insulator line that cause by melting. Besides, utilizing the decreasing circuit breaker or others related equipment can use to avoid the possibility of explosion of the transformer. If the failure happen during the operation of the power system, a huge interference will definitely may occur. Therefore, by installing the DONGBUSAN S/S #3M.Tr neutral earth reactor among TOP and BOTTOM BRACE part in the power system, the causes of the rising temperature and reason of the over-current flow that cause by over-current can be analyze.

CHARACTERISTICS OF THE FAIRCHILD 486 CCD AT MAIDANAK ASTRONOMICAL OBSERVATORY IN UZBEKISTAN (우즈베키스탄 Maidanak 천문대 Fairchild 486 CCD의 기본적인 특성)

  • Lim, Beom-Du;Sung, Hwan-Kyung;Karimov, R.;Ibrahimov, M.
    • Publications of The Korean Astronomical Society
    • /
    • v.23 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • Understanding of the basic characteristics of an astronomical instrument is a prerequisite to obtaining reliable data from the instrument. We have analyzed more than 1,000 calibration images from the Fairchild 486 CCD (hereafter the Maidanak 4k CCD system) attached to the AZT-22 1.5m telescope at Maidanak Astronomical Observatory in Uzbekistan. The Maidanak 4k CCD system supports three readout modes through 1, 2, or 4 amplifiers. In most cases observers use 4-amplifier readout mode to save time. We have tested the stability and seasonal variation of zero levels and confirm that two quadrants of the images (Amp 1 & 2) show no appreciable seasonal variation. but the other two quadrants (Amp 3 & Amp 4) show an evident seasonal variation in the bias level. The Cryo Tiger, the cooling system used at the Maidanak 4k CCD system, maintains the CCD temperature at -108'E, and effectively suppresses the dark electrons. The mean value versus the variance plot of the flat images does not show the expected relation for an ideal Poisson noise distribution and this is attributed to the large variation in quantum efficiency between different pixels. In addition, we confirm that there is no appreciable difference in gain between readout amplifiers, but there is a large variation in quantum efficiency across CCD chip especially in U. Due to the finite length of shutter opening and closing time, the effective exposure time varies across the science images. We introduce two parameters to quantify the effect of this uneven illumination and present a method to remove these effects. We also present a method to remove the interference patterns appearing in the images obtained with longer wavelength filters and investigate the spatial variation of the point spread function.

Structural health monitoring of a newly built high-piled wharf in a harbor with fiber Bragg grating sensor technology: design and deployment

  • Liu, Hong-biao;Zhang, Qiang;Zhang, Bao-hua
    • Smart Structures and Systems
    • /
    • v.20 no.2
    • /
    • pp.163-173
    • /
    • 2017
  • Structural health monitoring (SHM) of civil infrastructure using fiber Bragg grating sensor networks (FBGSNs) has received significant public attention in recent years. However, there is currently little research on the health-monitoring technology of high-piled wharfs in coastal ports using the fiber Bragg grating (FBG) sensor technique. The benefits of FBG sensors are their small size, light weight, lack of conductivity, resistance corrosion, multiplexing ability and immunity to electromagnetic interference. Based on the properties of high-piled wharfs in coastal ports and servicing seawater environment and the benefits of FBG sensors, the SHM system for a high-piled wharf in the Tianjin Port of China is devised and deployed partly using the FBG sensor technique. In addition, the health-monitoring parameters are proposed. The system can monitor the structural mechanical properties and durability, which provides a state-of-the-art mean to monitor the health conditions of the wharf and display the monitored data with the BIM technique. In total, 289 FBG stain sensors, 87 FBG temperature sensors, 20 FBG obliquity sensors, 16 FBG pressure sensors, 8 FBG acceleration sensors and 4 anode ladders are installed in the components of the back platform and front platform. After the installation of some components in the wharf construction site, the good signal that each sensor measures demonstrates the suitability of the sensor setup methods, and it is proper for the full-scale, continuous, autonomous SHM deployment for the high-piled wharf in the costal port. The South 27# Wharf SHM system constitutes the largest deployment of FBG sensors for wharf structures in costal ports to date. This deployment demonstrates the strong potential of FBGSNs to monitor the health of large-scale coastal wharf structures. This study can provide a reference to the long-term health-monitoring system deployment for high-piled wharf structures in coastal ports.

Speckle Noise Reduction of Ultrasonic NDT Using Adaptive Filter in WT Domain (웨이브렛 변환 평면에서 적응 필터를 이용한 초음파 비파괴검사의 스펙클 잡음 감소)

  • Jon, C.W.;Jon, K.S.;Lee, Y.S.;Lee, J.;Kim, D.Y.;Kim, S.H.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.21-29
    • /
    • 1996
  • Industrial equipment, such as power plant, is required to operate reliably, continuously and economically under rather severe conditions of temperature, stress, and enbironment. To test structural integrity and fitness, ultrasonic nondestructive testing is used because of effectiveness and simplicity. In this paper, wavelet transform based least mean square(LMS) algorithm is applied to reduce the influence of the interference occurring between randomly positioned small scatters. The RUN test is performed to check the nonstationarity of the speckle noise signal. The performance of this new approach is compared with that of the time domain LMS algorithm by means of condition numbers, signal-to-noise ratio and 3-D image. As a result, the wavelet transform based LMS algorithm shows better performance than the time domain LMS algorithm in this experiment.

  • PDF

Design and Implementation of Low Power Touch Screen Controller for Mobile Devices (모바일용 저전력 터치 스크린 제어 회로 설계 및 구현)

  • Park, Sang-Bong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.12 no.6
    • /
    • pp.279-283
    • /
    • 2012
  • In is paper, we design and implement the low power, high speed touch screen controller that calculates and outputs the coordinate of touch point on the touch screen of mobile devices. The system clock is 10HMz, the number of input channels is 21, standby current is $20{\mu}A$, dynamic range of input is 140pF~400pF and the response time is 0.1ms/frame. It contains the power management unit for low power, automatic impedance calibration unit in order to adapt to humidity, temperature and evaluation board, adjacent key and pattern interference suppression unit, serial interface unit of I2C and SPI. The function and performance is verified by using FPGA and $0.18{\mu}m$ CMOS standard process. The implemented touch screen is designed for using in the double layer ITO(Indium Thin Oxide) module with diamond pattern and single layer ITO module for cost-effective which are applied to mobile phone or smart remote controller.

Micropattern generation by holographic lithography and fabrication of quantum wire array by MOCVD (홀로그래픽 리소그래피에 의한 미세패턴 형성과 MOCVD에 의한 양자세선 어레이의 제작)

  • Kim, Tae-Geun;Cho, Sung-Woo;Im, Hyun-Sik;Kim, Young;Kim, Moo-Sung;Park, Jung-Ho;Min, Suk-Ki
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.114-119
    • /
    • 1996
  • The use of holographic interference lithography and removal techniques to corrugate GaAs substrate have been studied. The periodic photoresist structure, which serves as a protective mask during etching, is holographically prepared. Subsequently periodic V-grooved pattern is formed on the GaAs substrate by conventional a H$_{2}$SO$_{4}$-H$_{2}$O$_{2}$-H$_{2}$O wet etching. The linewidth of a GaAs pattern is about 0.4$\mu$m and the depth is 0.5$\mu$m A quantum wires(QWRs) array is well formed on the V-grooved substrate by MOCVD (metalorganic chemical vapor deposition) growth of GaAs/Al$_{0.5}$Ga$_{0.5}$As (50$\AA$/300$\AA$) quantum wells. The formation of QWR array is confirmed by the temperature dependent photoluminescence (PL) measurement. The intensive PL peak with a FWHM of 6meV at 21K shows the high quality of the QWR array.

  • PDF

Effects of Mn-dopping in Orthoferrite $LaFeO_3$ (Orthoferrite $LaFeO_3$에서의 Mn 치환 효과)

  • 채광표;이성환;이성호;이영배
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.2
    • /
    • pp.81-85
    • /
    • 2000
  • Crystallographic and magnetic properties of the Mn-doped orthoferrite LaFe$_{1-x}$Mn$_{x}$ O$_3$(0.0$\leq$x$\leq$O.4) system have been investigated by means of x-ray diffractometry, M ssbauer spectroscopy, vibrating sample magnetometer and super-conducting quantum interference device. The structure of the system was found to be orthorhombic distorted perovskite structure. At room temperature, the M ssbauer spectra for x=0.0 consists of one Zeeman sextets from Fe$^{3+}$ ions at octahedral sites. The M ssbauer spectra of two Zeeman sextets (x$\leq$0.1) change one Zeeman sextets and a paramagnetic doublet (x=0.4). The saturation magnetization increases but the coercivity decreases with increasing x in LaFe$_{1-x}$Mn$_{x}$ O$_3$.

  • PDF