• 제목/요약/키워드: Interference screw

검색결과 60건 처리시간 0.02초

생분해성 간섭나사를 이용한 전방 십자 인대 재건술 후 발생한 결절종 - 증례보고 - (Pretibial Ganglion after Anterior Cruciate Ligament Reconstruction with Bioabsorbable Interference Screw fixation $(Bioscrew^{\circledR})$ - A Case Report -)

  • 송은규;심상돈;김명선
    • 대한관절경학회지
    • /
    • 제6권2호
    • /
    • pp.188-191
    • /
    • 2002
  • 자가 슬괵건을 이용한 전방 십자인대의 재건술시 사용되는 Poly-L-Lactic-Acid 성분의 생분해성 간섭나사로 인한 합병증은 많지 않다. 저자들은 전방 십자 인대 재건술시 생분해성 간섭나사로 이식건을 고정 후 경골 터널 전방에 발생한 결절종에 대해 결절종 절제술과 동시에 간섭나사를 제거한1예에 대해 보고하는 바이다.

  • PDF

축 수직단면 형상정의에 대한 대형 스크류의 가공시 공구간섭검사 (Tool interference check in machining of large screws defined by cross-section view)

  • 안중환
    • 한국생산제조학회지
    • /
    • 제9권3호
    • /
    • pp.169-177
    • /
    • 2000
  • In machining screws which are important members in mono pumps or progressive cavity pumps CNC turning center with 3 axes is usually used. This sort of screw machining requires large amount of CL data points and rotational tools are used in machining. When working out the CL data points consideration of possible tool interference is important in order to avoid undercut. This paper describes the checking methods of tool interference in the screw machining on the CNC turning center. First of all a specific shape of a screw cross-section that could commonly be applied to all screws was chosen and then possible tool interference associated with that shape was identified. Checking method was mathematically developed and verified. This checking method will be utilized in the CAM system developed by the authors for screw machining on the 3-axis CNC turning center.

  • PDF

전 십자 인대 재건술에서 대퇴골측 고정 방법의 초기 안정성의 비교 (Comparison of Primary Stability of Different Femoral Fixation Techniques in Anterior Cruciate Ligament Reconstruction)

  • 송은규;이근배;이문
    • 대한관절경학회지
    • /
    • 제2권1호
    • /
    • pp.85-92
    • /
    • 1998
  • Various methods for fixation of graft have been widely used for reconstruction of anterior cruciate ligament. However, the biomechanical strength of each fixation techniques are not fully understood. The purpose of this study is to compare the pull out strength of different fixation techniques which is probably the most important factor for the success at the initial stage of healing. Biomechanical test was carried out to measure and compare the pull out tensile strength of five different fixation techniques in 35 pig(Yorkshire) knees. ANOVA and Duncan multiple comparison test was applied for statistical analysis. In the two fixation techniques with bone patellar tendon bone graft, the mean maximum tensile strength was $1333.4{\pm}148.5N$ with titanium interference screw, while it was $1310.1{\pm}168.9N$ with biodegradable interference screw. The failure mode were pulled out of bone plugs from the femoral tunnel in majority cases. In the fixations with hamstring tendon, the mean maximum tensile strength were $1405.9{\pm}135.1N$ with SemiFix screw, $820.3{\pm}104.5N$ with biodegradable interference screw, and $682.1{\pm}54.2N$ with Endobutton. The mode of failure was variable in each technique. The tendon was pulled out from the tunnel in biodegradable interference screw fixation, the screw was bent in the SemiFix system, and the polyester tape were ruptured or the buttons were pulled into tunnel in Endobutton fixation. The mean maximum tensile strength of two interference screws with bone patellar tendon bone was statistically comparable to that of SemiFix with hamstring tendon. However biodegradable interference screw and Endobutton with hamstring tendon showed weaker maximum tensile strength than above three fixation techniques (P<0.05).

  • PDF

생분해성 간섭나사를 이용한 전방십자인대 재건술 후 발생한 지연성 염증반응 - 증례 보고 - (The Delayed Inflammatory Reaction after Anterior Cruciate Lligament Reconstruction with a Bioabsorbable Interference Screw Fixation - A Case Report -)

  • 임홍철;노경선;양재혁
    • 대한관절경학회지
    • /
    • 제10권1호
    • /
    • pp.87-90
    • /
    • 2006
  • 자가 슬개건을 이용한 전방십자인대 재건술 시 사용되는 생분해성 간섭나사로 인한 합병증은 많지 않다. 저자들은 슬개건을 사용한 전방십자인대 재건술 시 생분해성 간섭 나사로 이식건을 고정 후 경골과 대퇴골 터널에 발생한 지연성 염증반응 1예에 대해 보고하고자 한다.

  • PDF

전방 십자 인대 재건술 후 후방으로 전위된 대퇴 간섭 나사의 후방 경격막 도달법을 이용한 제거 - 증례 보고 - (Removal of a Femoral Interference Screw that Migrated Posteriorly after ACL Reconstruction, Using Posterior Trans-septal Portal - A Case Report -)

  • 안진환;이상학;하해찬
    • 대한관절경학회지
    • /
    • 제10권2호
    • /
    • pp.187-191
    • /
    • 2006
  • 전방 십자 인대 재건술 후 대퇴 간섭 나사가 후방 구획으로 전위된 예는 극히 드물게 보고되고 있다. 이는 대개의 경우 기계적인 증상을 일으키므로 수술적인 제거술이 요구된다. 그러나 나사를 관절경적으로 제거하는 것은 기술적으로 어려운 술기이며 특히, 나사가 후방 구획으로 이동되었으나 전방 십자 인대가 잘 유지되어 있는 경우, 혹은 나사 주위가 막으로 둘러 쌓여 있을 경우 관절경적 제거는 더욱 어렵다. 저자들은 전방 십자 인대 재건술 후 재건 인대가 생착된 11년 후에 대퇴 간섭 나사가 후방 구획으로 전위된 1예를 보고하고자 한다. 저자들은 경우 가장 힘든 후방 구획에 위치한 전위된 대퇴 간섭 나사를 전방십자인대 이식건의 손상 없이 후방 경격막 도달법을 이용한 관절경적으로 제거하여 좋은 결과를 얻었기에 문헌고찰과 함께 보고하고자 한다.

  • PDF

워엄 스크루 가공용 사이드 밀링의 공구 간섭 시뮬레이션 (The Cutting Tool-workpiece Interference Simulation for Worm Screw Machining by Side Milling)

  • 이민환;김선호;안중환
    • 한국정밀공학회지
    • /
    • 제28권1호
    • /
    • pp.11-18
    • /
    • 2011
  • A worm screw is widely used in a geared motor unit for motion conversion from rotation to linear. For mass production of a high quality worm, the current rolling process is substituted with the milling process. Since the milling process enables the integration of all operations of worm manufacturing on a CNC(Computer Numerical Control) lathe, productivity can be remarkably improved. In this study, the tooling system for side milling on a CNC lathe to improve machinability is developed. However, the cutting tool-workpiece interference is important factors to be considered for producing high quality worms. For adaptability of various worms machining, the tool-workpiece interference simulation system based on a tool-tip trajectory model is developed. The developed simulation system is verified through several kinds of worms and experimental results.

워엄 스크루 가공을 위한 플래내터리 밀링의 공구 간섭 시뮬레이션 (The Cutting Tool-workpiece Interference Simulation for Worm Screw Machining by Planetary Milling)

  • 이민환;김선호;안중환
    • 한국정밀공학회지
    • /
    • 제26권12호
    • /
    • pp.47-54
    • /
    • 2009
  • A worm screw is widely used in a geared motor unit for motion conversion from rotation to linear. For mass production of a high quality worm, the current rolling process is substituted with the milling process. Since the milling process enables the integration of all operations of worm manufacturing on a CNC(Computer Numerical Control) lathe, productivity can be remarkably improved. In this study, the tooling system for planetary milling on a CNC lathe to improve machinability is developed. However, the cutting tool-workpiece interference is important factors to be considered for producing high quality worms. For adaptability of various worms machining, the tool-workpiece interference simulation system based on a tool-tip trajectory model is developed. The developed simulation system is verified through several kinds of worms and experimental results.

슬괵건을 이용한 전방십자인대 재건술시 횡고정 핀과 간섭나사를 이용한 대퇴터널 고정술 -수술 수기- (Cross-Pin and Interference Screw Femoral Fixation in Anterior Cruciate Ligament Reconstruction using Hamstring Tendon -Technical Note-)

  • 인용;박원종;박종범;홍승환
    • 대한관절경학회지
    • /
    • 제6권1호
    • /
    • pp.60-63
    • /
    • 2002
  • 목적 : 네 겹의 슬괵건을 이용한 전방십자인대 재건술시 대퇴터널을 횡고정 핀과 흡수성 간섭나사로 함께 고정하는 수기를 소개하고자 한다. 수술 술기 : 반건양건과 박건을 채취하여 네 겹으로 준비하였다. 경골터널과 대퇴터널을 만드는데 대퇴터널의 깊이는 35 mm로 하였다. Rigidfix system의 가이드를 삽입하고 가이드의 위쪽 관에만 구멍을 내었다. 이식건을 통과시킨후 횡고정 핀 을 고정하였다. 이후 이식건을 경골쪽으로 당기면서 흡수성 간섭 나사로 고정하였다. 결론 : 슬괵건 전방십자인대 재건술시 횡고정 핀과 흡수성 간섭나사를 이용한 대퇴터널 고정은 강한 초기 고정과 이식건의 골통합을 촉진시킬 수 있는 좋은 방법으로 사료되어 소개하였다.

  • PDF

간섭나사를 이용한 관절경적 상완 이두건 대흉근 상부 건 고정술의 임상적 결과 (Clinical Results of Arthroscopic Biceps Long Head Tenodesis Above the Pectoralis Major Using an Interference Screw)

  • 최상수;강홍제;김정우;김종윤;김동문;김광미
    • Clinics in Shoulder and Elbow
    • /
    • 제16권2호
    • /
    • pp.94-99
    • /
    • 2013
  • 목적: 간섭나사(interference screw)를 이용한 관절경적 상완 이두건 대흉근 상부 건 고정술의 임상적 결과를 분석하고자 하였다. 대상 및 방법: 2008년 1월부터 2010년 1월까지 간섭나사를 이용한 관절경적 상완 이두건 장두의 대흉근 상부 건 고정술을 시행한 환자를 대상으로 하였고, 이 중 최소 1년 이상 추시 가능하였던 30예를 대상으로 하였다. 그 중 회전근 개 파열을 동반한 경우는 20예였다. 결과는 VAS, ASES, 상완 이두건 구의 통증, 고정실패 및 변형 정도로 판단하였다. 결과: 최종 추시에서 모든 환자에서 수술 전에 비해 VAS, ASES점수는 의미 있게 호전되었으나(p<0.05), 5예(17%)에서 견관절 전방 통증 및 상완 이두건 구의 압통이 존재하였고, 3예(10%)에서 고정실패로 인한 Popeye 변형이 존재하였다. 또한, 회전근 개 파열을 동반하지 않는 군에서 파열을 동반한 군보다 좋은 결과를 얻을 수 있었다(p<0.05). 결론: 상완 이두건 근위부 병변에 의한 통증이 있는 환자에서 간섭나사를 이용한 관절경적 상완 이두건 장두의 대흉근 상부 건 고정술은 좋은 결과를 얻을 수 있어 유용한 치료방법으로 사료되나, 17%에서 상완 이두건구에 압통이 존재해 이에 대한 추가적 연구가 필요할 것으로 사료된다.

사체 아킬레스건을 이용한 경골관통터널방식의 후방십자인대 재건술 - 간섭나사 및 이중고정핀 방식에 따른 초기연신 및 활주율 평가 - (The Posterior Cruciate Ligament (PCL) Reconstruction by the Transtibial Tunnel Method using Cadaveric Achilles Tendon Grafts - Evaluation of the Initial Lengthening and the Slippage Ratio due to the Interference Screw Fixation and Double Cross-Pin Fixation -)

  • 김철웅;배지훈;오동준
    • 대한기계학회논문집A
    • /
    • 제33권4호
    • /
    • pp.430-439
    • /
    • 2009
  • Posterior Cruciate Ligament (PCL) plays an important role in knee extension. Rotational instability due to injured PCL can be restored by various PCL reconstruction methods. In this study, the initial lengthening affected by fixation device and location was demonstrated, and furthermore, the slippage and the relationship between lengthening ratio and slippage ratio in the calcaneus and soft tissue fixation methods was newly suggested. Eight specimens of proximal tibia and Achilles tendon grafts were harvested from four cadavers and divided into four groups in regard to the four different types of transtibial fixation techniques. The cyclic load ranged from 50 N to 250 N applied to each graft fixed to proximal tibia in 55 degrees. The initial lengthening ratio to the total elongation has been approximately constant regardless of the fixation methods. The soft tissue fixation method with an interference screw showed about 56.4% slippage ratio to the total elongation and the same method with a double cross-pin presented about 45.4% slippage ratio. The soft tissue fixation method with an interference screw demonstrated approximately 2 mm less total elongation and about 13% more slippage than lengthening because of poor fixation compared to the same method with a double cross-pin.