• Title/Summary/Keyword: Interference correction

Search Result 141, Processing Time 0.023 seconds

A Study on the Design and Implementation of a DSSS-based MODEM for a Right Termination System(FTS) (대역확산방식 비행종단시스템의 모뎀설계와 구현에 관한 연구)

  • Lim Keumsang;Kim Jaehwan;Cho Hyangduck;Kim Wooshik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2C
    • /
    • pp.175-183
    • /
    • 2006
  • This letter proposes a Direct Sequence Spread Spectrum (DS-SS)-based Flight Termination System(FTS) and show the simulation results and implements the system using FRGAs. The DS-SS FTS has immunity interference signals and the influence of jamming signal. Moreover, a DS-SS FTS can provides effects on an authentication and encryption with spread codes. And the system uses more less power than an analog FM system. We used Reed-Solomon (32, 28) code and triple Data Encryption Standard(3DES) for error correction and data encryption. Also we used counter algorithm for unauthenticated device's attack The spread codes of In-phase channel and Quadrature channel were generated by Gold sequence generators. The system was implemented in Altera APEX20K100E FPGA for the ground system and EPF10K100ARC240-3 for the airborne system.

Correction of Transverse Discrepancy with Slowly Maxillary Expansion by Hyrax type expander in Adult Patient (성인에서 Hyrax 장치로 완속상악확장하여 폭경부조화를 개선한 증례)

  • Kwak, Kyoung Ho;Kim, Seong Sik;Kim, Yong-Il;Park, Soo-Byung;Son, Woo-Sung
    • The Journal of the Korean dental association
    • /
    • v.55 no.6
    • /
    • pp.400-410
    • /
    • 2017
  • Approximately 30% of adult patients who want orthodontic treatment have transverse discrepancy with insufficient width of the maxilla. Particularly, in Class III patients requiring orthognathic surgery, the frequency of insufficient width of the maxillary arch related to respiratory problems is high. We report a case of non-surgical maxillary expansion using a Hyrax type expander with an orthognathic surgery, based on the reports that the ratio of non-fused midpalatal suture is not high in adults. A 30 years and 2 months old woman with a long face showed an Angle Class III with a vertical growth pattern. Class III molar and canine relation, anterior edge bite, and mandibular incisor compensatory lingual inclination were observed. The posterior buccal overjet seemed to be appropriate, but I diagnosed that there was a transverse discrepancy, for the following reasons. The inter-canine and inter-molar widths were sufficient but excessive lingual inclination of the mandibular molars was observed when assessing the bucco-lingual inclination based on the center of resistance of the maxillary and mandibular first molar. For this reason, it was expected that intercuspal interference would occur during orthodontic decompensation. Therefore, slow maxillary expansion using Hyrax type expander was performed and 2-jaw rotation surgery was performed to improve aesthetic and occlusion. Adults can also improve width discrepancy by non-surgical methods, which can avoid SARPE requiring additional surgery or segmental surgery lacking stability and predictability.

  • PDF

Transmission performance Improvement of Wireless ATM Cell in Fading Channel (페이딩 채널에서 무선 ATM 셀전송 성능개선에 관한 연구)

  • Chung, Boo-Young;Park, Ki-Sik;Kang, Young-Heung;Cho, Sung-Joon;Lee, Jin
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.2
    • /
    • pp.179-190
    • /
    • 1998
  • One of the most important topics of recent years is that a multimedia technology such as wireless ATM has been introduced in radio systems for video, voice and data transmission. A major problem in such systems is the occurrence of errors due to multipath fading or interference. To combat this problem, forward error correction (FEC) coding is commonly used as a means of eliminating these errors. This paper has analyzed theoretically the effect of fading to design effective wireless ATM system. The BER, CLR, and CER of wireless ATM system adopting FEC coding and diversity reception techniques have been derived in fading environment. Also, simulations of BER and CLR have been carried out and compared with the above theoretical results.

  • PDF

Pre-service teachers' errors and difficulties in task modification focusing on cognitive demand (수학 예비교사들이 과제의 인지적 노력 수준 변형에서 겪는 오류와 어려움)

  • Kang, Hyangim;Choi, Eunah
    • The Mathematical Education
    • /
    • v.60 no.1
    • /
    • pp.61-76
    • /
    • 2021
  • The purpose of this study is to analyze the errors and difficulties which pre-service secondary teachers shows during the task modification in consideration of the cognitive demand and to provide significant implications to the pre-service teacher education program related to the modification of the mathematical tasks. In the pursuit of this purpose, tasks were selected from perpendicular bisector units and 24 pre-service teachers were asked to modify the tasks to higher and lower level tasks. After the modification activities, opportunities for reflection and modification were provided. The findings from analysis are as follows. Pre-service teachers had a difficulty to distinguish between PNC tasks and PWC tasks. Also, We identified the interference phenomena that pre-service teachers depended on the apparent elements of the task. Pre-service teachers showed a tendency to overlook the learning objectives and learning hierarchy during the task modification, and to focus on some types of task modification. However, pre-service teachers were able to have meaningful learning opportunities and extend the category of tools to technology including Geogebra through self-reflection and correction activities on task modification. The above results were summed up and we presented the implications to the task modification program in the pre-service secondary teacher education.

Trace-Back Viterbi Decoder with Sequential State Transition Control (순서적 역방향 상태천이 제어에 의한 역추적 비터비 디코더)

  • 정차근
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.40 no.11
    • /
    • pp.51-62
    • /
    • 2003
  • This paper presents a novel survivor memeory management and decoding techniques with sequential backward state transition control in the trace back Viterbi decoder. The Viterbi algorithm is an maximum likelihood decoding scheme to estimate the likelihood of encoder state for channel error detection and correction. This scheme is applied to a broad range of digital communication such as intersymbol interference removing and channel equalization. In order to achieve the area-efficiency VLSI chip design with high throughput in the Viterbi decoder in which recursive operation is implied, more research is required to obtain a simple systematic parallel ACS architecture and surviver memory management. As a method of solution to the problem, this paper addresses a progressive decoding algorithm with sequential backward state transition control in the trace back Viterbi decoder. Compared to the conventional trace back decoding techniques, the required total memory can be greatly reduced in the proposed method. Furthermore, the proposed method can be implemented with a simple pipelined structure with systolic array type architecture. The implementation of the peripheral logic circuit for the control of memory access is not required, and memory access bandwidth can be reduced Therefore, the proposed method has characteristics of high area-efficiency and low power consumption with high throughput. Finally, the examples of decoding results for the received data with channel noise and application result are provided to evaluate the efficiency of the proposed method.

A clinical study on the effects of myocardial protection during open heart surgery (개심술에서 술중 심근보호효과에 관한 임상적연구)

  • 김근호
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.230-240
    • /
    • 1987
  • Cardioplegia and myocardial protection were performed under cardiopulmonary bypass during open-heart surgery with the use of cold St. Thomas Hospital cardioplegic solution [4=C] for the coronary artery perfusion and normal saline solution [4- C] for the topical cardiac cooling. To maintain the state of myocardial protection, coronary artery reperfusion was carried out using St. Thomas Hospital cardioplegic solution at the interval of 30 minutes. A total number of patients studied were 57 cases, including 37 cases of correction for congenital cardiac anomalies and 20 cases for acquired heart valvular diseases. Cardiopulmonary bypass time during the surgery was observed to be average of 87.89*47.55 hours, aortic cross-clamping time to be average of 76.68~44.27 hours raging from 30 to 191 minutes. In order to evaluate the effects of myocardial protection in the surgery, serum enzyme levels were determined. To observe the relationship between aortic cross-clamping time and myocardial protection effects, patients studied were divided into the following 3 groups. I group: aortic cross-clamping time, 60 minutes, II group: aortic cross-clamping time, 90 minutes, III group: aortic cross-clamping time, over 91 minutes. 1. Changes in serum enzyme levels in postoperative period. [1] SCOT; The postoperative value [increased over 200 units] for ischemic myocardial injury during operation was observed in 11 cases [19.3% of the total] of the total patients studied, of which 4 cases [13.3%] in I group, 1 case [10.0%] in II group, and 6 cases [35.3%] in III group. [2] LDH; The positive value [increased over 900 units] for ischemic myocardial injury during operation was observed in 9 cases [15.7% of the total] of the total patients studied, of which 2 cases [6.6%] in I group, 1 case [10.0%] in II group, and 6 cases [35.3%] in III group. [3] CPK; The positive value [increased over 800 units] for ischemic myocardial injury during operation was observed in 10 cases [17. 5% of the total] of the total patients studied, including 4 cases [13. 3%] in I group, 1 case [10.0%] in II group, and 5 cases [29.4%] in III group. 2. The myocardial protection method used in the present study was demonstrated to be effective for the myocardial protection in the surgery with aortic cross-clamping time of up to 90 minutes. A few ischemic myocardial injury were observed in the surgery with aortic cross-clamping time over 91 minutes, but no significant cardiac dysfunction was noted. The surgery with aortic cross-clamping time of up to 191 minutes did not appear to give rise any significant interference with postoperative recovery.

  • PDF

The viterbi decoder implementation with efficient structure for real-time Coded Orthogonal Frequency Division Multiplexing (실시간 COFDM시스템을 위한 효율적인 구조를 갖는 비터비 디코더 설계)

  • Hwang Jong-Hee;Lee Seung-Yerl;Kim Dong-Sun;Chung Duck-Jin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.2 s.332
    • /
    • pp.61-74
    • /
    • 2005
  • Digital Multimedia Broadcasting(DMB) is a reliable multi-service system for reception by mobile and portable receivers. DMB system allows interference-free reception under the conditions of multipath propagation and transmission errors using COFDM modulation scheme, simultaneously, needs powerful channel error's correction ability. Viterbi Decoder for DMB receiver uses punctured convolutional code and needs lots of computations for real-time operation. So, it is desired to design a high speed and low-power hardware scheme for Viterbi decoder. This paper proposes a combined add-compare-select(ACS) and path metric normalization(PMN) unit for computation power. The proposed PMN architecture reduces the problem of the critical path by applying fixed value for selection algorithm due to the comparison tree which has a weak point from structure with the high-speed operation. The proposed ACS uses the decomposition and the pre-computation technique for reducing the complicated degree of the adder, the comparator and multiplexer. According to a simulation result, reduction of area $3.78\%$, power consumption $12.22\%$, maximum gate delay $23.80\%$ occurred from punctured viterbi decoder for DMB system.

A Clinical Study on the Effects of Myocardial Protection of St. Thomas Hospital Cardioplegic Solution During Open Heart Surgery (개심술에서 St. Thomas Hospital 심정지액의 심근보호효과에 관한 임상적 연구)

  • Kim, Yeong-Hak;Kim, Geun-Ho
    • Journal of Chest Surgery
    • /
    • v.22 no.2
    • /
    • pp.225-233
    • /
    • 1989
  • Cardioplegia and myocardial protection were performed under cardiopulmonary bypass during open heart surgery with the use of St. Thomas Hospital cardioplegic solution [4 [C] for the coronary artery perfusion and normal saline solution [4[ c] for the topical cardiac cooling. To maintain the state of myocardial protection, coronary artery reperfusion was carried out using St. Thomas Hospital cardioplegic solution at the interval of 30 minutes. A total number of patients studied were 57 cases, including 37 cases of correction for congenital anomalies and 20 cases for acquired heart diseases. Cardiopulmonary bypass time during the surgery was observed to be average of 87.89*47.55 hours, aortic cross-clamping time [ACCT] to be average of 76.68*44.27 hours raging from 30 to 191 minutes. In order to evaluate the effects of myocardial protection in the surgery, serum enzyme levels were determined. To observe the relationship between ACCT and myocardial protection effects, patients studied were divided into the following 3 groups. I group: ACCT 60 minutes, II group: ACCT 90 minutes, III group: ACCT over 91 minutes [1] SGOT; The positive value [increased over 200 units] for ischemic myocardial injury during operation was observed in 11 cases [19.3% of the total] of the total patients studied, of which 4 cases [13.3%] in I group, 1 case [10.0%] in II group, and 6 cases [35.3%] in III group. [2] LDH; The positive value [increased over 900 units] for ischemic myocardial injury during operation was observed in 9 cases [15.7% of the total] of the total patients studied, of which 2 cases [6.6%] in I group, 1 case [10.0%] in II group and 6 cases [35.3%] in III group. [3] CPK; The positive value [increased over 800 units] for ischemic myocardial injury during operation was observed in 10 cases [17.5% of the total] of the total patients studied, including 4 cases [13.3%] in I group, 1 case [10.0%] in II group, and 5 cases [29.4%] in III group [4] The myocardial protection method used in the present study was demonstrated to be effective for the myocardial protection in the surgery with ACCT of up to 90 minutes. A few ischemic myocardial injury were observed in the surgery with ACCT over 91 minutes, but no significant cardiac dysfunction was noted. The surgery with ACCT of up to 191 minutes did not appear to give rise any significant interference with postoperative recovery.

  • PDF

Shipboard Active Phased Array Antenna System for Satellite Communications (위성 통신용 선박 탑재 능동 위상배열 안테나 시스템)

  • 전순익;채종석;오승엽
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.10
    • /
    • pp.1089-1097
    • /
    • 2002
  • In this paper, the novel shipboard Active Phased Array Antenna(APAA) system for maritime mobile satellite communications is introduced. The antenna uses novel technologies like wide range hybrid tracking, single antenna elements with both of Rx and Tx, asymmetrical array structure, interference isolation between Rx and Tx, and error correction method from frequency scan effect. The antenna has single aperture for both of Rx and Tx with 32 $\times$ 4 two-dimensional array. The antenna has two beams. Its frequencies are 7.25 ~ 7.75 GHz for Rx and 7.9 ~ 8.4 GHz for Tx. The antenna gains are 35.4 dBi for Rx and 35.7 dBi for Tx, those are 54 % of efficiency. The electrically steering ranges are $\pm$35$^{\circ}$ of elevation direction and $\pm$4$^{\circ}$ of azimuth direction. The mechanical control ranges at hybrid tracking capability are continuous 360$^{\circ}$ of azimuth direction and $\pm$10$^{\circ}$ of elevation direction. The antenna has 2.2$^{\circ}$ of 3 dB beamwidth, -14 dB of sidelobe level, and 21 dB of cross-pol suppression. The antenna performance was measured by near field measurement set. Its system performance was tested on the ship motion simulator and with the satellite transponder simulator. The test result showed that its tracking error was within -3 dB from its peak gain under motion condition. The antenna system was tested by real modulated Direct Broadcasting Satellite(DBS) signals to check its communication processing function.

Erlang capacity for the reverse link of an imperfect power controlled DS/CDMA cellular system in multipath fading environments (다중경로 페이딩 환경에서 불완전 전력제어된 DS/CDMA 셀룰라 시스템의 역방향 링크에 대한 얼랑용량)

  • Kim, Hang-Rae;Kim, Nam
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.37 no.5
    • /
    • pp.1-9
    • /
    • 2000
  • In this paper, for the reverse link of a imperfect power controlled DS/CDMA cellular system when a mobile radio channel is a Rayleigh distributed multipath fading channel, A extended DS/CDMA blocking probability formula considering both shadowing and multipath fading is derived. Erlang capacity and equivalent channel number considering shadowing are analyzed and compared with those considering both shadowing and multipath fading, respectively. The DS/CDMA blocking probability is calculated based on the analysis method that obtains Erlang capacity and ICF(interference correction factor) using the median value of $E_{b(i)}$/ $I_{0}$ corresponding to each reverse link user Assuming that the blocking probability set 2%, it is observed that the Erlang capacity is 19.97 Erlang at the data rate $R_{b}$=9.6 kbps and 11.67 Erlang at the data rate $R_{b}$=14.4 kbps and then is less 16% and 19% than the Erlang capacity considering shadowing only, respectively. It is also shown that the effect of multipath fading must not be ignored and then exact Erlang capacity and equivalent channel numbers that the DS/CDMA cellular system can support are provided.d.d.d.

  • PDF