• Title/Summary/Keyword: Interfacial water

Search Result 339, Processing Time 0.031 seconds

An Experimental Investigation of the Interfacial Condensation Heat Transfer in Steam/water Countercurrent Stratified Flow in a Horizontal Pipe

  • Chu, In-Cheol;Yu, Seon-Oh;Chun, Moon-Hyun;Kim, Byong-Sup;Kim, Yang-Seok;Kim, In-Hwan;Lee, Sang-Won
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.565-570
    • /
    • 1998
  • An interfacial condensation heat transfer phenomenon in a steam/water countercurrent stratified flow in a nearly horizontal pipe has been experimentally investigated. The present study has been focused on the measurement of the temperature and velocity distributions within the water layer. In particular, the water layer thickness used in the present work is large enough so that the turbulent mixing is limited and the thermal stratification is established. As a result, the thermal resistance of the water layer to the condensation heat transfer is increased significantly. An empirical correlation of the interfacial condensation heat transfer has been developed. The present correlation agrees with the data within $\pm$15%

  • PDF

Molecular Area and Interfacial Tension Behavior of Span 20 and Tween series surfactants at water/air interface (Span 20과 Tween계 계면활성제의 물/공기 계면에서의 분자면적과 계면장력 거동)

  • 김천희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.24 no.7
    • /
    • pp.1065-1072
    • /
    • 2000
  • The molecular areas and the interfacial tension behavior of ten nonionic surfactants, i.e., Span 20 and Tween 20, 40, 60. 80, 21, 61, 81, 65, & 85 are tested to assay their effects on the wetting and liquid retention properties of hydrophilic and hydrophobic fibrous materials. The molecular areas at water/air interface are derived from Gibbs’adsorption equations. The following conclusions are drawn from the results: 1) Span 20 is efficient in lowering the interfacial tension and effective in adsorption at the water/air interface, resulting in the low interfacial tension at critical micelle concentration (${\gamma}$$_{CMC}$) and a small molecular area($\omega$), 2) when the hydrophiles of the surfactants are constant, $\omega$’s increase as hydrophobe carbon numbers of the surfactants increase, 3) when the hydrophobes are constant, ${\gamma}$$_{CMC}$’s and $\omega$’s increase as the hydrophile ethylene oxide units increase, indicating effectiveness and efficiency is parallel in this case, 4) the ethylene oxide unit length as a hydrophile has greater influence on u than the hydrophobe chain length.han the hydrophobe chain length.gth.

  • PDF

A Study on the Mechanical Properties of Interfacial Transition Zone (ITZ) of Lightweight High Strength Concrete Via Nanoindentation (나노 인덴테이션을 통한 경량 고강도 콘크리트 Interfacial Transition Zone (ITZ)의 역학적 특성에 관한 연구)

  • Im, Su-Min;Bae, Sung-Chul
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.8 no.4
    • /
    • pp.537-544
    • /
    • 2020
  • The interfacial transition zone(ITZ) which is the boundary layer between cement composites and aggregates is considered to be the region of gradual transition, heterogeneous, and the weakest part of concrete. For the development of lightweight high strength concrete, it is essential to evaluate the mechanical properties of ITZ between high strength concrete with low water-binder ratio and lightweight aggregates. However, the mechanical properties of ITZ are not well established due to its high porosity and complex structure. Furthermore, the properties of ITZ in concrete using lightweight aggregates are dominated by more various variations (e.g. water-binder ratio, water absorption capacity of aggregate, curing conditions) than normal-weight aggregate concrete. This study aims to elucidate the mechanical properties of ITZ in lightweight high-strength cement composites according to the types of aggregates and the aggregate sizes. Nanoindentation analysis was used to evaluate the elastic modulus of ITZ between high strength cement composites with the water-binder ratio of 0.2 and normal sand, lightweight aggregate with different aggregate siz es of 2mm and 5mm in this study.

One-Dimensional Model for Flow Resistance of Floodplain Vegetation in Compound Open-Channel Flow (복단면 개수로흐름에서 홍수터 식생의 흐름저항을 반영한 1차원 모형)

  • Park, Moon-Hyeong
    • Journal of Korea Water Resources Association
    • /
    • v.43 no.6
    • /
    • pp.517-524
    • /
    • 2010
  • In this study, the 1D apparent shear stress model for vegetated compound open-channel flows was suggested. To consider the effect of momentum exchange between main channel and floodplain, the eddy viscosity concept was used in the present model. The interfacial eddy viscosity in the interface of main channel and floodplain was determined from the 3D Reynolds stress model. The evaluated interfacial eddy viscosity appears to be good agreement with those proposed previously. To investigate the effect of interfacial eddy viscosity, sensitive analysis was carried out. the computed backwater profiles are nearly identical with respect to the value of the interfacial eddy viscosity. However, the discharge conveyed by the floodplain changes is proportional to the interfacial eddy viscosity. Finally, the changes of the interfacial eddy viscosity due to the vegetation density and vegetation height were examined. The computed results of interfacial eddy viscosity are in proportion to the vegetation density and vegetation height, and the interfacial eddy viscosity has a range of $(2-5)\;{\times}\;10^{-4}$.

Interfacial Condensation Heat Transfer for Countercurrent Steam-Water Stratified Flow in a Circular Pipe

  • Chu, In-Cheol;Chung, Moon-Ki;Yu, Seon-Oh;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.32 no.2
    • /
    • pp.142-156
    • /
    • 2000
  • An experimental study of steam condensation on a subcooled thick water layer (0.018 ~0.032 m) in a countercurrent stratified flow has been performed using a nearly horizontal circular pipe. A total of 103 average interfacial condensation heat transfer coefficients were obtained and parametric effects of steam and water flow rates and the degree of subcooling on condensation heat transfer were examined. The measured local temperature and velocity distributions in the thick water layer revealed that there was a thermal stratification due to the lack of full turbulent thermal mixing in the lower region of the water layer Two empirical Nusselt number correlations, one in terms of average steam and water Reynolds numbers, and the water Prandtl number, and the other in terms of the Jakob number in place of the Prandtl number, which agree with most of the data within $\pm$ 25%, were developed based on the bulk flow properties. Comparisons of the present data with existing correlations showed that the present data were significantly lower than the values predicted by existing correlations.

  • PDF

Characteristics Correlations Between Fiber-Reinforced and Interfacial Adhesion in Carbon fiber reinforced Cement composite Prepared by Slurry Method. (슬러리법에 의한 탄소섬유보강 시멘트복합체의 제조에서 보강섬유와 계면결착제와의 상관특성)

  • Choi, Eung-Kyoo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.2 no.3
    • /
    • pp.131-138
    • /
    • 2002
  • The objective of the study is to examine the characteristic correlations between reinforcing carbon fiber and interfacial adhesion agent since the interfacial adhesion strength between reinforcing carbon fiber and matrices is believed to be an essential element influencing the physical properties in carbon fiber reinforced cement composite using slurry method. The integrity of interfacial adhesion between reinforcing fiber and cement not only affects the quality of fiber reinforced cement composite but also influences to a large degree the physical properties of the cement composite when producing carbon fiber reinforced cement composite using slurry method. Having analyzed the physical properties 1.e., water content, tensile strength, flexural strength and flexural toughness of carbon fiber reinforced cement composite specimens, C-PAM(cation polyacrylamide) was determined to be an optimum interfacial adhesion agent. The study has also demonstrated that interfacial adhesion strength varies largely on the content and type of the reinforcing fiber. Judging from magnified view of the tensile shear cross-section using VMS(video microscope system), interfacial adhesion strength between reinforcing fiber and matrices is affected by the type of interfacial adhesion agent. According to the result of the experiments, C-PAM was determined to be an ideal interfacial adhesion agent when using carbon fiber in producing carbon fiber reinforced cement composite with the optimum content of carbon fiber being established.

Improved performance of polyamide nanofiltration membranes by incorporating reduced glutathione during interfacial polymerization

  • Jiao, Zhiwei;Zhou, Linjie;Wu, Mengyuan;Gao, Kang;Su, Yanlei;Jiang, Zhongyi
    • Korean Journal of Chemical Engineering
    • /
    • v.35 no.12
    • /
    • pp.2487-2495
    • /
    • 2018
  • Inspired by the specific amino acid sequence Asn-Pro-Ala (NPA) of water channel aquaporins (AQPs), we fabricated polyamide (PA) nanofiltration (NF) membranes by introducing reduced glutathione (GSH) in interfacial polymerization (IP) method. Fourier transform infrared spectroscopy (ATR-FTIR), X-ray photoelectron spectrometry (XPS), scanning electron microscope (SEM), atomic force microscopy (AFM), zeta potential and static water contact angle measurement were employed to characterize the chemical composition, morphology, electronegativity and hydrophilicity of the NF membranes. The water flux of GSH/PIP-TMC NF membrane reached $32.00L\;m^{-2}h^{-1}$ at 0.2 MPa, which was approximately twice than that of pristine PIP-TMC NF membrane when the ratio of GHS to piperazidine (PIP) was 40% during IP process. More water channels were built as GSH was embedded into PA layer. The fabricated NF membranes also took on potent rejection for dyes and $Na_2SO_4$. This study presents a simple and facile method to simulate water channels-based biological materials which may find potential application in water treatment.

Effect of Diffusion on the Interfacial Adhesion of Poly(hydroxy ether) Coated Caron Fibers (계면확산에 의한 Poly(hydroxy ether) 코팅된 탄소섬유의 계면접착력 변화 연구)

  • 강현민;윤태호
    • Composites Research
    • /
    • v.12 no.6
    • /
    • pp.15-21
    • /
    • 1999
  • Carbon fibers were coated with carboxy modified poly(hydroxy ether)(C-PHE, water dispersed), water soluble polymers poly(hydroxy ether ethanol amine)(PHEA) or water insoluble poly(hydroxy ether)(PHE). Interfacial shear strength of polymer coated carbon fibers was measured by micro-droplet tests with vinyl ester resin, and approximately 30 samples were tested. The interfacial adhesion of poly-mers to carbon fibers was also evaluated, and diffusion behavior of polymer films in vinyl ester resin was investigated. The carbon fibers after testing and diffusion samples were analysed by SEM in order to understand adhesion mechanism. Interfacial shear strength of carbon fibers was enhanced by the coating of PHE and C-PHE which have good or marginal solubility in vinyl ester resin, respectively, but not by the coating of PHEA possibly due to the poor solubility in vinyl ester resin.

  • PDF

The Nature of Water in Tactic Poly (2-Hydroxyethyl Methacrylate) Hydrogels

  • Kim, Eui-Hwan;Jeon, Sang-Il;Yoon, Sung-Chul;Jhon, Mu-Shik
    • Bulletin of the Korean Chemical Society
    • /
    • v.2 no.2
    • /
    • pp.60-66
    • /
    • 1981
  • The hypothesis that three classes of water exist in hydrogels, namely X water (free water-like), Z-water (bound water-like), and Y water (interfacial water-like), has been verified and generally accepted. To further check the validity of this hypothesis and to study the nature of X, Y, and Z water as conformation changes, several experiments have been done using Tactic Poly(2-hydroxyethyl methacrylate) (P-HEMA) gels. Thermal expansively data for tactic P-HEMA gel was obtained. In each case of isotactic and syndiotactic P-HEMA, the higher water content gels showed an extremely sharp volume change at $0^{\circ}C$, indicating the presence of normal free water-like. Lower water content gels showed no anomalous change in thermal expansion, indicating that the water is bound water-like. The medium water content gels exhibited intermediate behavior. These results were also confirmed by bulk gel conductivity measurments. The differential scanning calorimeter(DSC) experiment was simply introduced to further verify the bound water-like quantities which was obtained by the method of dilatometry and specific conductivity. Observing the amounts of X, Y, and Z water with the change of tacticity, the similar content of bound water-like may be due to the same primary structure of isotactic and syndiotactic polymer and the difference in free and interfacial water-like content may be due to the difference in secondary and tertiary structure of tactic polymer. Therefore, as the polymer conformation varies, the free and interfacial water-like content will be varied. In order to demonstrate these concepts, Russel et al.'s CPK space-filling molecular models of isotactic and syndiotactic P-HEMA was utilized.

Electron Tunneling and Electrochemical Currents through Interfacial Water Inside an STM Junction

  • Song, Moon-Bong;Jang, Jai-Man;Lee, Chi-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.1
    • /
    • pp.71-74
    • /
    • 2002
  • The apparent barrier height for charge transfer through an interfacial water layer between a Pt/Ir tip and a gold surface has been measured using STM technique. The average thickness of the interfacial water layer inside an STM junction was controlled by the amount of moisture. A thin water layer on the surface was formed when relative humidity was in the range of 10 to 80%. In such a case, electron tunneling through the thin water layer became the majority of charge transfers. The value of the barrier height for the electron tunneling was determined to be 0.95 eV from the current vs. distance curve, which was independent of the tip-sample distance. On the other hand, the apparent barrier height for charge transfer showed a dependence on tip-sample distance in the bias range of 0.1-0.5 V at a relative humidity of approximately 96%. The non-exponentiality for current decay under these conditions has been explained in terms of electron tunneling and electrochemical processes. In addition, the plateau current was observed at a large tip-sample distance, which was caused by electrochemical processes and was dependent on the applied voltage.