• 제목/요약/키워드: Interfacial stability

검색결과 265건 처리시간 0.024초

Review of Entrainment and Interfacial Stability in Thermosyphons and Capillary-Driven Heat Pipes

  • Kim, B.H.;Kim, C.J.
    • 태양에너지
    • /
    • 제18권3호
    • /
    • pp.205-215
    • /
    • 1998
  • Entrainment in thermosyphons and heat pipes was characterized in view of the interfacial stability associated with the critical Weber number and the entrainment limit at the onset of liquid entrainment from the liquid or wicked interface. Both literature review and theoretical analysis on the entrainment models were peformed in order to evaluate accuracy of the predicted value. For this purpose, the models were categorized in two groups according to their entrainment mechanism and interfacial configurations, i.e., the wave-induced entrainment and the shear-induced entrainment, respectively. Thus, the twelve models(five models for the wave-induced entrainment and seven for the shear induced entrainment) were examined to obtain individual trends and their discrepancies from the general tendency of the overall models. As a result, the critical Weber numbers and entrainment limits were calculated and represented as a function of vapor temperature for the chosen characteristic dimensions of the interface.

  • PDF

Translucent Microemulsion의 제조 공정과 안정성 (Manufacturing Process of Translucent Microemulsion and Its Stability)

  • 배덕환;신재섭
    • 한국응용과학기술학회지
    • /
    • 제17권3호
    • /
    • pp.167-173
    • /
    • 2000
  • The process variables for the manufacture of translucent microemulsion prepared with 2-octyl dodecanol, 12-hydroxy stearic acid cholesteryl , POE(40)HCO and 1,3-butandiol were examined initially (primary emulsion) and following aging for three months. The techniques empolyed in this study were particle size, turbidity, interfacial tension and microfluidizer. Particle size analysis and turbidity measurement to evaluate the emulsion stability were used. It was concluded that the process of the emulsification was an important indicator of the stability of the translucent microemulsion. From the particle size and and turbidity measurement of translucent microemulsion, adding the surfactant to the oil phase before the emulsification was found to be the most important factor for the stability of emulsions. We found that interfacial tension of the adding the surfactant to the oil phase is lower than that of the adding the surfactant to aqueous phase. In spite of hydrophilic surfactant, adding the surfactant to aqueous phase produced inferior emulsion to that to oil phase.

Application of Hyperbolic Two-fluids Equations to Reactor Safety Code

  • Hogon Lim;Lee, Unchul;Kim, Kyungdoo;Lee, Won-Jae
    • Nuclear Engineering and Technology
    • /
    • 제35권1호
    • /
    • pp.45-54
    • /
    • 2003
  • A hyperbolic two-phase, two-fluid equation system developed in the previous work has been implemented in an existing nuclear safety analysis code, MARS. Although the implicit treatment of interfacial pressure force term introduced in momentum equation of the hyperbolic equation system is required to enhance the numerical stability, it is very difficult to implement in the code because it is not possible to maintain the existing numerical solution structure. As an alternative, two-step approach with stabilizer momentum equations has been selected. The results of a linear stability analysis by Von-Neumann method show the equivalent stability improvement with fully-implicit solution method. To illustrate the applicability, the new solution scheme has been implemented into the best-estimate thermal-hydraulic analysis code, MARS. This paper also includes the comparisons of the simulation results for the perturbation propagation and water faucet problems using both two-step method and the original solution scheme.

도포된 오일의 변화에 따른 Epoxy/EPDM 계면의 교류 절연 파괴 특성에 관한 연구 (A Study on the AC Interfacial Breakdown Properities of the Interface between Epoxy/EPDM with the variation of spreaded oil)

  • 배덕권;이수길;정일형;이준웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.897-899
    • /
    • 1999
  • In this paper, the interfacial dielectric breakdown phenomenon of interface between Epoxy/EPDM (ethylene propylene diene terpolymer) was discussed, which affects stability of insulation system of power delivery devices. Specimen structure was designed by using MAGSOFT's FLUX2D based on the finite elements method. Design concepts is to reduce the effect of charge transport from electrode in the process of breakdown and to have the tangential electrical potential with the Epoxy/EPDM interface. AC interfacial breakdown phenomenon of was investigated by variation of interfacial conditions oil and temperature which are supposed to have influence on the interfacial breakdown strength. Interfacial breakdown strength was improved by spreading oil over interfacial surface. The decreasing ratio of the AC interfacial breakdown strength in non-oiled specimens was increased by the temperature rising and its of oiled specimens was not affected by temperature.

  • PDF

Stability analysis on the concrete slab of the highest concrete-faced rock-fill dam in South Korea

  • Baak, Seung-Hyung;Cho, Gye-Chun;Song, Ki-Il
    • Geomechanics and Engineering
    • /
    • 제13권5호
    • /
    • pp.881-892
    • /
    • 2017
  • Design and management of concrete slabs in concrete-faced rock-fill dams are crucial issues for stability and overall dam safety since cracks in the concrete face induced by stress, shrinkage, and deterioration can cause severe leakage from the reservoir into the dam. Especially, the increase of dam height to a certain level to enhance the storage capacity and to improve hydraulic stability can lead to undesirable deformation behavior and stress distribution in the existing dam body and in the concrete slabs. In such conditions, simulation of a concrete slab with a numerical method should involve the use of an interface element because the behavior of the concrete slab does not follow the behavior of the dam body when the dam body settles due to the increase of dam height. However, the interfacial properties between the dam body and the concrete slab have yet to be clearly defined. In this study, construction sequence of a 125 m high CFRD in South Korea is simulated with commercial FDM software. The proper interfacial properties of the concrete slab are estimated based on a comparison to monitored vertical displacement history obtained from the concrete slab. Possibility of shear strength failure under the critical condition is investigated based on the simplified model. Results present the significance of the interfacial properties of the concrete slab.

Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value

  • Yoon, Hong-Gi;Heo, Seong-Joo;Koak, Jai-Young;Kim, Seong-Kyun;Lee, Su-Young
    • The Journal of Advanced Prosthodontics
    • /
    • 제3권1호
    • /
    • pp.10-15
    • /
    • 2011
  • PURPOSE. This study investigated the influence of bone quality and surgical technique on the implant stability quotient (ISQ) value. In addition, the influence of interfacial bone quality, directly surrounding the implant fixture, on the resonance frequency of the structure was also evaluated by the finite element analysis. MATERIALS AND METHODS. Two different types of bone (type 1 and type 2) were extracted and trimmed from pig rib bone. In each type of bone, the same implants were installed in three different ways: (1) Compaction, (2) Self-tapping, and (3) Tapping. The ISQ value was measured and analyzed to evaluate the influence of bone quality and surgical technique on the implant primary stability. For finite element analysis, a three dimensional implant fixture-bone structure was designed and the fundamental resonance frequency of the structure was measured with three different density of interfacial bone surrounding the implant fixture. RESULTS. In each group, the ISQ values were higher in type 1 bone than those in type 2 bone. Among three different insertion methods, the Tapping group showed the lowest ISQ value in both type 1 and type 2 bones. In both bone types, the Compaction groups showed slightly higher mean ISQ values than the Self-tapping groups, but the differences were not statistically significant. Increased interfacial bone density raised the resonance frequency value in the finite element analysis. CONCLUSION. Both bone quality and surgical technique have influence on the implant primary stability, and resonance frequency has a positive relation with the density of implant fixture-surrounding bone.

LSGM계 고체산화물 연료전지의 계면안정성을 위한 완층층의 도입 (Introduction of a Buffering Layer for the Interfacial Stability of LSGM-Based SOFCs)

  • 김광년;문주호;손지원;김주선;이해원;이종호;김병국
    • 한국세라믹학회지
    • /
    • 제42권9호
    • /
    • pp.637-644
    • /
    • 2005
  • In order to find a proper buffering material which can prohibit an unwanted interfacial reaction between anode and electrolyte of LSGM-based SOFC, we examined a gadolinium doped ceria and scandium doped zirconia as a candidate. For this examination, we investigated the microstructural and phase stability of the interface under different buffering layer conditions. According to the investigation, ceria based material induced a serious La diffusion out of the LSGM electrolyte resulted in the formation of very resistive $LaSrGa_3O_7$ phase at the interface. On the other hand zirconia based material was directly reacted with LSGM electrolyte and thus produced very resistive reaction products such as $La_2Zr_2O_7,\;Sr_2ZrO_4,\;LaSrGaO_4\;and\;LaSrGa_3O_7$. From this study we found that an improper buffering material induced the higher internal cell resistance rather than an interfacial stability.

도라지 추출물로부터 천연계면활성제의 개발 (Development of a Natural Surfactant from Extracts of Platycodon Grandiflorum)

  • 김희진;박숙경;김보영;홍슬기;조성기;김동욱
    • Korean Chemical Engineering Research
    • /
    • 제46권2호
    • /
    • pp.227-232
    • /
    • 2008
  • 화장품용 천연계면활성제를 개발하기 위해 도라지(platycodon grandiflorum) 껍질에서 유기용매를 이용하여 추출물을 얻었다. 도라지 추출물의 화장품용 계면활성을 측정하기 위해 계면장력, 용해도, 기포력, 분산력, 유화력, 유화활성, 유화안정성을 측정하였고 피부자극을 평가하기위해 첩포시험을 실시하였다. 도라지 사포닌 함량이 0.005 wt%일 때 castor oil에 대한 계면장력은 11.5 dyn/cm로 비교대상인 Tween 40이나 quillaja bark보다 낮은 계면활성을 보여주었다. 도라지 추출물은 화장품에 유상으로 사용되는 olive oil, soybean oil, canola oil에 대해서도 우수한 유화활성과 유화안정성을 나타내었다. 2~5%의 도라지 추출물과 글리세린을 사용한 피부자극 시험에서는 도라지 추출물은 약간의 피부자극을 보여 주었다. 결론적으로 도라지 추출물은 화장품용 계면활성력은 양호하나 다소의 피부자극을 보여주었다.

Electrochemical Properties of Cathode according to the Type of Sulfide Electrolyte and the Application of Surface Coating

  • Yoon, Da Hye;Park, Yong Joon
    • Journal of Electrochemical Science and Technology
    • /
    • 제12권1호
    • /
    • pp.126-136
    • /
    • 2021
  • The electrochemical performance of all-solid-state cells (ASSCs) based on sulfide electrolytes is critically affected by the undesirable interfacial reactions between oxide cathodes and sulfide electrolytes because of the high reactivity of sulfide electrolytes. Based on the concept that the interfacial reactions are highly dependent on the type of sulfide electrolyte, the electrochemical properties of the ASSCs prepared using three types of sulfide electrolytes were observed and compared. The Li2MoO4-LiI coating layer was also introduced to suppress the interfacial reactions. The cells using argyrodite electrolyte exhibited a higher capacity and Coulombic efficiency than the cells using 75Li2S-22P2S5-3Li2SO4 and Li7P3S11 electrolytes, indicating that the argyrodite electrolyte is less reactive with cathodes than other electrolytes. Moreover, the introduction of Li2MoO4-LiI coating on the cathode surface significantly enhanced the electrochemical performance of ASSCs because of the protection of coating layer. Pulverization of argyrodite electrolyte is also effective in increasing the capacity of cells because the smaller size of electrolyte particles improved the contact stability between the cathode and the sulfide electrolyte. The cyclic performance of cells was also enhanced by pulverized electrolyte, which is also associated with improved contact stability at the cathode/electrolyte. These results show that the introduction of Li2MoO4-LiI coating and the use of pulverized sulfide electrolyte can exhibit a synergic effect of suppressed interfacial reaction by the coating layer and improved contact stability owing to the small particle size of electrolyte.

Effect of Electron Beam Irradiation on the Interfacial and Thermal Properties of Henequen/Phenolic Biocomposites

  • Pang, Yansong;Yoon, Sung Bong;Seo, Jeong Min;Han, Seong Ok;Cho, Donghwan
    • 접착 및 계면
    • /
    • 제6권4호
    • /
    • pp.12-17
    • /
    • 2005
  • Natural fiber/phenolic biocomposites with chopped henequen fibers treated at various levels of electron beam irradiation (EBI) were made by means of a matched-die compression molding method. The interfacial property was explored in terms of interfacial shear strength measured by a single fiber microbonding test. The thermal properties were studied in terms of storage modulus, tan ${\delta}$, thermal expansion and thermal stability measured by dynamic mechanical analysis, thermomechanical analysis and thermogravimetric analysis, respectively. The result showed that the interfacial and thermal properties depend on the treatment level of EBI done to the henequen fiber surfaces. The present result also demonstrates that 10 kGy EBI is most preferable to physically modify the henequen fiber surfaces and then to improve the interfacial property of the biocomposite, supporting earlier results studied with henequen/poly (butylene succinate) and henequen/unsaturated polyester biocomposites.

  • PDF