• Title/Summary/Keyword: Interfacial breakdown strength

Search Result 35, Processing Time 0.023 seconds

Breakdown Characteritics of XLPE/EPDM on the Treatment Condition of the Interfacial layer (XLPE/EPDM의 계면처리조건에 따른 절연파괴 특성)

  • 한성구;조정형;이창종;박양범;박강식;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.230-233
    • /
    • 1996
  • In this paper, We intended to evaluate characteristics of XLPE/EPDM interface which exists in the cable joint. Because the fault was mainly occurred in this interface. We investigated breakdown characteristics of XLPE/EPDM double layered insulator as a funtion of temperature, pressure, annealing time, kinds of jointmaterial. It was shown that breakdown strength of XLPE/EPDM insulators is higher that of XLPE/XLPE or EPDM/EPDM

  • PDF

Improvement of Interfacial Performances on Insulating and Semi-conducting Silicone Polymer Joint by Plasma-treatment

  • Lee, Ki-Taek;Huh, Chang-Su
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.1
    • /
    • pp.16-20
    • /
    • 2006
  • In this paper, we investigated the effects of short-term oxygen plasma treatment of semiconducting silicone layer to improve interfacial performances in joints prepared with a insulating silicone materials. Surface characterizations were assessed using contact angle measurement and x-ray photoelectron spectroscopy (XPS), and then adhesion level and electrical performance were evaluated through T-peel tests and electrical breakdown voltage tests of treated semi-conductive and insulating joints. Plasma exposure mainly increased the polar component of surface energy from $0.21\;dyne/cm^2$ to $47\;dyne/cm^2$ with increasing plasma treatment time and then leveled off. Based on XPS analysis, the surface modification can be mainly ascribed to the creation of chemically active functional groups such as C-O, C=O and COH on semi-conductive silicone surface. This oxidized rubber layer is inorganic silica-like structure of Si bound with three to four oxygen atoms ($SiO_x,\;x=3{\sim}4$). The oxygen plasma treatment produces an increase in joint strength that is maximum for 10 min treatment. However, due to brittle property of this oxidized layer, the highly oxidized layer from too much extended treatment could be act as a weak point, decreasing the adhesion strength. In addition, electrical breakdown level of joints with adequate plasma treatment was increased by about $10\;\%$ with model samples of joints prepared with a semi-conducting/ insulating silicone polymer after applied to interface.

Research for Phenomena of XLPE/EPDM Interface (XLPE/EPDM 계면현상에 관한 연구)

  • Kim, Ji-Hwan;Ko, Kwang-Chul;Nam, Jin-Ho;Suh, Kwang-S.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1407-1409
    • /
    • 1998
  • It was investigated that space charge characteristics and Breakdown characteristics of XLPE/EPDM laminates as a function of interfacial condition. When the chemical A was pasted in laminate interface, there was little space charge in XLPE/EPDM interface and it was shown that breakdown strength of XLPE/EPDM laminate was influenced by laminate condition.

  • PDF

Electrical characteristics on the interfacial heat treatment time between XLPE/EPDM laminates (XLPE/EPDM 계면의 열처리 시간에 따른 전기적 특성)

  • Choi, W.C.;Lee, C.J.;Kim, S.K.;Jo, D.S.;Park, K.S.;Kim, J.S.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1503-1506
    • /
    • 1997
  • The main fault in this interface is that power cable insulating materials are mainly composed of a double layered structure, XLPE/EPDM laminates in cable joint. In this paper, we instituted the interface of normal and degassed XLPE/EPDM and then investigated the breakdown and conduction characteristics as a function of heat treatment time. The results showed that conduction and breakdown strength was influenced by volatile crosslinking by-products which remained inside the insulating material during the production of XLPE and EPDM, especially during heat treatment process. And micro voids and surface roughness also influenced the conduction current and breakdown strength.

  • PDF

Effects of Interfacial Conditions on Breakdown Strength of XLPE/EPDM Laminates (XLPE/EPDM의 계면조건이 절연파괴강도에 미치는 영향)

  • Choi, W.C.;Lee, C.J.;Jo, D.S.;Park, K.S.;Kim, J.S.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1273-1275
    • /
    • 1998
  • The main faults at cable joint are mainly originate from double layered structure, which is composed of different kinds of materials such as XLPE/EPDM laminatest. In this paper, to investigate the effect of interfacial condition and coagents on dielectric strength of XLPE/EPDM, we prepared XLPE/grease/EPDM, XLPE/grease + coagent/EPDM laminates. Dielectric strength of the XLPE/EPDM laminates pasted with the grease compounded crosslinking coagent (TMPTA, TMPTMA) is higher than that of the laminates paseted with the grease without coagent.

  • PDF

Analysis of Insulating Reliability in Epoxy Composites (Epoxy 복합체의 절연 신뢰도 해석)

  • 임중관;천민우;박용필
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.724-728
    • /
    • 2001
  • In this study, the dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. The dielectric breakdown characteristics origin in epoxy composites were examined and various effects of dielectric breakdown on epoxy composites were also discussed. As a result, first of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. And the breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised, the electric field is concentrated, and the acceleration of electron and the growth of electron avalanche are early accomplished. In the case of filled specimens with treating silane, the breakdown strength become much higher since this suggests that silane coupling agent improves interfacial combination and relaxs electric field concentration. Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1%, the applied field value needed to be under 21.5㎹/cm.

  • PDF

A Study on Thermal, Mechanical and Electrical Properties as Silane Treated Epoxy/MICA Composites (실란처리된 Epoxy/MICA 콤포지트의 열적, 기계적 전기적 특성연구)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.213-218
    • /
    • 2013
  • In this study, epoxy/mica composite was prepared by mixing with mechanical stirrer together with homogenizer, and the effect of amino-type silane coupling agent was also studied. To reduce the viscosity without any decrement of other properties, 1,4-Butanediol diglycidyl ether (1,4-BDGE) as an aliphatic epoxy reactive diluent was introduced to the epoxy/mica composite in order to use as vanish for high voltage motor and generator stator winding. It was confirmed by scanning electron microscopy (SEM) observation that interfacial characteristics between organic epoxy and inorganic mica was modified by coupling agent treatment so that glass transition temperature increased, and tensile strength and electrical breakdown strength increased. The properties were estimated by Weibull statistical analysis and the ac electrical breakdown strength was 20.2% modified by treating silane coupling agent.

Evaluation of Electrical Degradation in Epoxy Composites by DC Dielectric Breakdown Properties (DC 절연파괴 특성을 이용한 Epoxy 복합체의 전기적 열화 평가)

  • 임중관;박용필
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2002.11a
    • /
    • pp.779-783
    • /
    • 2002
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were simulated by Weibull distribution probability. As a result, first of all, speaking of dielectric breakdown properties, the more hardener increased the stronger breakdown strength at low temperature because of cross-linked density by the virtue of ester radical. And the breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised, the electric field is concentrated, and the acceleration of electron and the growth of electron avalanche are early accomplished. In the case of filled specimens with treating silane, the breakdown strength become much higher since this suggests that silane coupling agent improves interfacial combination and relaxs electric field concentration. Finally, from the analysis of weibull distribution, it was confirmed that as the allowed breakdown probability was given by 0.1%, the applied field value needed to be under 21.5MVcm.

  • PDF

Compatibilizing Effect of SEBS for Electrical Properties of LDPE/PS Blends (LDPE/PS 블렌드의 전기적 성질에 미치는 상용화제로서의 SEBS의 효과)

  • Kim Tae Young;Kim Dong Myung;Kim Won Jung;Lee Je Hyuk;Suh Kwang S.;Lee Tae Hee
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.3
    • /
    • pp.114-119
    • /
    • 2005
  • We investigated compatibilizing effects of electrical properties such as charge distributions and electrical breakdown in blends of low density polyethylene (LDPE) / polystyrene (PS) with poly [styrene-b-(ethylene-co-butylene)-b-styrene] (SEBS), the triblock copolymer. The blends with $70\;wt\%$ of LDPE and $30\;wt\%$ of PS were prepared through a melt blending in a batch type kneader at a temperature of $220^{\circ}C$ when the SEBS content increased up to $10\;wt\%$. Scanning electron microscopy (SEM) was investigated for observation of morphology of LDPE / PS blends increasing SEBS contents. The morphological observation showed that addition of SEBS results in the domain size reduction of the dispersed PS phase and a better interfacial adhesion between LDPE and PS phases. Measurements of space charge distributions for blends was carried out with pulsed electroacoustic (PEA) method. It was possible to observe that the amount of charge storage in the LDPE / PS blends decreased wiか increasing of SEBS content. The location of SEBS at a domain interface enables charges to move from one phase to the other via domain interface and results in a indicative decrease in the amount of space charge for the LDPE / PS blends with SEBS. Electrical breakdown strength of these blends was observed. It was found that the maximum breakdown strength of the blend was 51.55 kV/mm. These results were better than 38.38 kV/mm of LDPE used electrical insulator for cables and were caused by crystalinity of blends. Because the crystalinity of blends were lower than LDPE, electrical breakdown strength of LDPE / PS blends is higher than that of LDPE. We evaluated the possibility of these blends for insulating material substituted LDPE.

Electrical Characteristics of the Interfacial Layer between XLPE/EPDM Laminates on the Heat Treatment (열처리 조건에 따른 XLPE / EPDM 계면의 전기적 특성)

  • 최원창;이제정;김석기;조대식;한상옥;박강식
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.225-228
    • /
    • 1997
  • The main fault in this interface is that power cable insulating materials are mainly composed of a double layered structure, XLPE/FPDM laminates in cable joint. In this parer, we instituted the interface of XLPE/EPDM laminates and then investigated the breakdown and conduction characteristics as a function of heat treatment time. The results showed that conduction current was influenced by volatile crosslinking by-products which remained inside the insulating material during the production of XLPE and EPDM, especially during heat treatment process. And conduction current of XLPE/Oil 12500cSt/EPDM was more stable than XLPE/Grease/EPDM from the long heat treatment time. AC breakdown strength of silicone oil itself from the heat treatment was changed during the 4∼12 hour heat treatment time.

  • PDF