• 제목/요약/키워드: Interface monitoring

검색결과 768건 처리시간 0.033초

Vibration-based damage monitoring of harbor caisson structure with damaged foundation-structure interface

  • Lee, So-Young;Nguyen, Khac-Duy;Huynh, Thanh-Canh;Kim, Jeong-Tae;Yi, Jin-Hak;Han, Sang-Hun
    • Smart Structures and Systems
    • /
    • 제10권6호
    • /
    • pp.517-546
    • /
    • 2012
  • In this paper, vibration-based methods to monitor damage in foundation-structure interface of harbor caisson structure are presented. The following approaches are implemented to achieve the objective. Firstly, vibration-based damage monitoring methods utilizing a variety of vibration features are selected for harbor caisson structure. Autoregressive (AR) model for time-series analysis and power spectral density (PSD) for frequency-domain analysis are selected to detect the change in the caisson structure. Also, the changes in modal parameters such as natural frequency and mode shape are examined for damage monitoring in the structure. Secondly, the feasibility of damage monitoring methods is experimentally examined on an un-submerged lab-scaled mono-caisson. Finally, numerical analysis of un-submerged mono-caisson, submerged mono-caisson and un-submerged interlocked multiple-caissons are carried out to examine the effect of boundary-dependent parameters on the damage monitoring of harbor caisson structures.

Study on cognitive load of OM interface and eye movement experiment for nuclear power system

  • Zhang, Jingling;Su, Daizhong;Zhuang, Yan;QIU, Furong
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.78-86
    • /
    • 2020
  • The operation and monitoring (OM) interface is the digital medium between nuclear power system and operators. The cognitive load of OM interface has an important effect on the operation errors made by operator during OM task between operator and computer. The cognitive load model of OM interface is constructed for analysing the composition and influencing factors of OM interface cognitive load. And to study the coping strategies and methods for cognitive load of nuclear power system. An experiment method based on eye movement is proposed to measure the cognitive load of OM interface. Experiment case is carried out with 20 subjects and typical OM interface of a nuclear power system simulator. The OM interface is optimized based on the experiment results. And the results comparison between the original OM interface and the optimized OM interface shows that the cognitive load model and proposed method is valuable contributions in reducing the cognitive load and improving the interaction efficiency of OM tasks.

Development of an Agricultural Data Middleware to Integrate Multiple Sensor Networks for an Farm Environment Monitoring System

  • Kim, Joonyong;Lee, Chungu;Kwon, Tae-Hyung;Park, Geonhwan;Rhee, Joong-Yong
    • Journal of Biosystems Engineering
    • /
    • 제38권1호
    • /
    • pp.25-32
    • /
    • 2013
  • Purpose: The objective of this study is to develop a data middleware for u-IT convergence in agricultural environment monitoring, which can support non-standard data interfaces and solve the compatibility problems of heterogenous sensor networks. Methods: Six factors with three different interfaces were chosen as target data among the environmental monitoring factors for crop cultivation. PostgresSQL and PostGIS were used for database and the data middleware was implemented by Python programming language. Based on hierarchical model design and key-value type table design, the data middleware was developed. For evaluation, 2,000 records of each data access interface were prepared. Results: Their execution times of File I/O interface, SQL interface and HTTP interface were 0.00951 s/record, 0.01967 s/record and 0.0401 s/record respectively. And there was no data loss. Conclusions: The data middleware integrated three heterogenous sensor networks with different data access interfaces.

볼트 연결부 모니터링을 위한 다채널 무선 임피런스 센서노트와 EMI 인터페이스의 성능 분석 (Performance evaluation of EMI interface and multi-channel wireless impedance sensor node for bolted connection monitoring)

  • 윙 칵 유이;이포영;김정태
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2011년도 정기 학술대회
    • /
    • pp.36-39
    • /
    • 2011
  • In this paper, performance of EMI interface and multi-channel wireless impedance sensor node is evaluated for SHM on bolted connection. To achieve the objective, following approaches are implemented. Firstly, an interface washer is designed to monitor loosened bolt through the variation in EMI of interface washer due to change in preload in bolt. Secondly, a multi-channel wireless impedance sensor node based on Imote2 platform is designed for automated and cost-efficient impedance-based SHM on bolted connections. Finally, performance of the multi-channel wireless impedance sensor node and the interface washer are experimentally validated for a lab-scale bolted connection model. A damage monitoring method using RMSD index of EMI signatures is utilized to examine the strength of each individual bolted connection.

  • PDF

CAN 기반 제어 시스템 분석을 위한 인터페이스 유닛 설계 및 구현 (Design and Implementation of an Interface Unit for Analysis of a CAN-Based Control System)

  • 박병률;정구민;안현식;김도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.195-197
    • /
    • 2006
  • In this paper, an interface unit is designed to efficiently monitor transmission data in Controller Area Network(CAN)-based control systems. The CAN uses a serial multi master communication protocol that efficiently supports distributed real-time control with a very high level of data integrity, and communication speeds of up to 1Mbps. The interface unit is composed of a DSP controller which collects data on the CAN bus and transfers data to a personal computer via serial communication to save and display of interesting signals. The experimental system consists of three DSP controllers which represent electronic control units of a vehicle, an interface unit for analysing the data on the bus, and a graphic monitoring program coded on the Windows platform. The validity and the effectiveness of the proposed simple type of CAN interface unit are shown through the experimental results.

  • PDF

역사내 기존 시스템 인터페이스 방안 (A Plan of Existing System Interface within Station)

  • 이원재;안태기;신정렬
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1550-1555
    • /
    • 2011
  • This paper presents the system interface standard that are associated with additional devices like sensor nodes as well as fire monitoring panel, panic button and emergency call in city railroad environment. Existing fire monitoring panel, panic button and emergency call system is responsible for fire detection and alarm, emergency alarm and communication with the manager. Recently, researches that are associated with NVR-based intelligent integrated surveillance systems and existing alarm system are activated but most of the system is dedicated to it existing. In order to expand devices that is supported other monitoring function, separate device configuration or modification of integrated surveillance system are inevitable. In this study, interface standard between standard controller, integrated command center and each device that facilitate additional expansion of integrated surveillance system and avoid the extra cost is presented.

  • PDF

전화선자 인터텟을 이용한 3차원 원격 모니터링 시스템의 설계 (Design of 3-Dimensional Remote Monitoring System Using Telephone Line and Internet)

  • 양필수;김주환;김성호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.47-47
    • /
    • 2000
  • Most measuring devices are equipped with RS-232 or GPIB interface for communicating data with computers. If the measuring devices can be accessed by a server computer, the valuable information from the devices can be effectively shared with other computers via internet. But, if the measuring devices and the server computer are too far away, it is difficulty to directly connect them by RS232 interface. PSTN(Public Switched Telephone Network) refers to the world's collection of interconnected voice-oriented public telephone networks. Measuring computer system which is equipped with RS232 interface and modem for PSTN can be introduced to overcome the aforementioned distance problem, In this work, an internet based remote monitoring system which utilizes PSTN and VRML for 3-dimensional GUI is proposed.

  • PDF

Experimental investigation of magnetic-mount PZT-interface for impedance-based damage detection in steel girder connection

  • Ryu, Joo-Young;Huynh, Thanh-Canh;Kim, Jeong-Tae
    • Structural Monitoring and Maintenance
    • /
    • 제4권3호
    • /
    • pp.237-253
    • /
    • 2017
  • Among various structural health monitoring technologies, impedance-based damage detection has been recognized as a promising tool for diagnosing critical members of civil structures. Since the piezoelectric transducers used in the impedance-based technique should be bonded to the surface of the structure using bonding layers (e.g., epoxy layer), it is hard to maintain the as-built condition of the bonding layers and to reconfigure the devices if needed. This study presents an experimental investigation by using magnetically attached PZT-interface for the impedance-based damage detection in bolted girder connections. Firstly, the principle of the impedance-based damage detection via the PZT-interface device is outlined. Secondly, a PZT-interface attachment method in which permanent magnets are used to replace the conventional bonding layers is proposed. Finally, the use of the magnetic attraction for the PZT-interface is experimentally evaluated via detecting the bolt-loosening events in a bolted girder connection. Also, the sensitivity of impedance signatures obtained from the PZT-interface is analyzed with regard to the interface's material.

도시철도 역무실 통합 안전관리시스템 디스플레이의 Ecological Interface Design Prototype 개발 (Development of Ecological Interface Design Prototype on Integrated Safety Management System Display in Subway Station Office)

  • 이봉근;백지승;조성식;명노해;이덕희
    • 대한인간공학회지
    • /
    • 제29권4호
    • /
    • pp.661-665
    • /
    • 2010
  • Current subway station's office employee must perform safety management tasks by monitoring the various safety management systems. But these monitoring systems are limited in effective situational awareness and response to a state of emergency immediately. It is necessary to develop an integrated safety management system display. In this study, we developed subway station safety management system's (CCTV, fire detection & alarm system, screen door control equipment) integrated prototype display with ecological interface design framework and evaluated prototype display interface's usability with GOMS model. The result was that the ecological interface's performance was better than existing safety management system's interface.

진동기반 자기회귀모델을 통한 항만케이슨 지반-구조 경계부의 손상 모니터링 (Damage Monitoring in Foundation-Structure Interface of Harbor Caisson Using Vibration-based Autoregressive Model)

  • 이소라;이소영;김정태;박우선
    • 한국해안·해양공학회논문집
    • /
    • 제23권1호
    • /
    • pp.18-25
    • /
    • 2011
  • 본 연구에서는 진동기반 자기회귀모델을 이용하여 항만케이슨의 지반-구조 경계부 손상모니터링을 수행하였다. 이를 위해, 첫째, 케이슨 구조물의 지반-구조 경계부 손상모니터링을 위한 기법으로써 진동기반 자기회귀모델을 선정하였다. 둘째, 케이슨의 유한요소해석을 통하여 지반-구조 경계부 모니터링을 위한 진동기반 자기회귀모델 기법을 수치적으로 검증하였다. 마지막으로, 모형케이슨의 진동실험을 통해 진동기반 자기회귀모델 기법의 케이슨 지반-구조 경계부 손상 모니터링의 적용성을 검증하였다.