• 제목/요약/키워드: Interface condition

검색결과 1,191건 처리시간 0.026초

투명성과 강인 안정성을 고려한 1자유도 햅틱 인터페이스 제어기 설계 (1-DOF Haptic Interface Controller Design considering Transparency and Robust Stability)

  • 엄광식;서일홍
    • 대한전기학회논문지:시스템및제어부문D
    • /
    • 제49권4호
    • /
    • pp.213-219
    • /
    • 2000
  • In this paper, a controller design method is proposed for haptic interface considering transparency and robust stability. For this, a performance index for the transparency as performance measure is defined in the points of impedance matching and the optimal solution which is minimizing the performance index is obtained by solving H2 optimal problem. In haptic interface, the modeling uncertainties can be restricted to that of haptic device. To implement the robust stabilizing haptic controller to the uncertainties of haptic device, a robust stable condition using H$\infty$ norm from small gain theorem is proposed. To verify the effectiveness of the proposed haptic controller design scheme, numerical examples and experimental results are illustrated for virtual wall consisting of stiffness and damping factor.

  • PDF

화학적 영향을 고려한 토목섬유-지반 접촉면의 동적상대변위 (Dynamic Relative Displacement of Geosynthetic-Soil Interface Considering Chemical Effect)

  • 곽창원;오명학;장동인;박인준
    • 한국지반공학회논문집
    • /
    • 제32권11호
    • /
    • pp.73-81
    • /
    • 2016
  • 최근 늘어나고 있는 폐기물량에 따라 해상 폐기물 매립장의 건설이 연구되고 있으며, 매립장 내 폐기물의 보강 및 보호 목적으로 토목섬유가 널리 사용되고 있다. 토목섬유는 흙과의 접촉면을 형성하는데 지진시 접촉면에서의 동적 전단 거동이 폐기물 매립장의 지진시 거동 및 안정성을 지배하는 가장 중요한 요소이다. 따라서 접촉면 동적 전단거동 및 동적상대변위 파악이 매우 중요하다. 이러한 접촉면 거동은 주위 환경 및 하중조건에 의해 영향을 받으며 복잡한 응답을 보이므로 이론적 접근이 곤란하다. 본 연구에서는 침출수 내의 산성 및 염기성과 같은 성분이 반복 전단하중 상태에서 지반-토목섬유 접촉면의 동적 상대변위특성에 대하여 실내 시험을 수행하고 그 결과를 분석하였다. 이를 위하여 동적 접촉면 전단 시험기를 이용하여 산성 및 염기성 용액에 840일 장기수침 시료와 60일 단기수침시료에 대하여 반복 단순전단 시험을 수행 하였다. 그 결과 산성 및 염기성 조건 공통적으로 산성일 경우 접촉면의 상대변위가 가장 큰 값을 나타내어 접촉면 손상 정도의 크기가 상대적으로 큰 것으로 나타났다.

산업용 원심블로어 수치해석을 위한 수치모델 평가 (Evaluation of Numerical Models for Analysing an Industrial Centrifugal Blower)

  • 이종성;장춘만
    • 한국수소및신에너지학회논문집
    • /
    • 제23권6호
    • /
    • pp.688-695
    • /
    • 2012
  • The present study represents the effects of boundary condition on the performance of a centrifugal blower at the interference plane between rotational and stationary domains using three dimensional compressible Navier-Stocks equations. Two boundary conditions, frozen-rotor and stage, are compared to analyze the blower performance. Installation angle between the cutoff of a volute casing and a impeller blade is also introduced to evaluate the blower performance and to understand the internal flow inside the blower. Throughout numerical simulation, it is found that the frozen rotor interface method at the interference plane represents well the variations of flow field inside the blower compared to stage interface method. However, pressure has maximum two percent error according to the installation angles while pressure is almost constant for the stage interface method. And stage interface method can relatively well predict the blower performance. Detailed internal flows of the centrifugal blower are compared and analyzed by numerical simulation.

유비쿼터스 환경에서 다중 인터페이스를 탑재한 이동 단말의 인터페이스 선택 기법에 관한 연구 (A Study on the Interface Selection Scheme of Mobile Nodes with Multiple Interfaces in Ubiquitous Environments)

  • 김성철;문일영;조성준
    • 한국항행학회논문지
    • /
    • 제14권2호
    • /
    • pp.198-205
    • /
    • 2010
  • 유비쿼터스 환경에서 사용자가 언제 어디서나 네트워크에 접속할 수 있도록 하기 위해 다중 인터페이스 기술에 대한 관심과 연구가 늘고 있다. 본 논문에서는 다중 인터페이스를 탑재한 이동 단말이 이동 중에 단일 인터페이스만 고정적으로 이용하지 않고, 계속해서 변화하는 무선 채널의 상태에 따라 적절한 인터페이스를 적응적으로 이용하기 위한 기법을 제안한다. 본 논문에서 제안하는 기법은 각 인터페이스의 전송률과 패킷 오류율, 그리고 종단간 지연시간에 따라 가장 적절한 무선 인터페이스를 판단할 수 있다. 시뮬레이션 결과 본 논문에서 제안한 기법이 쓰였을 때 단일 인터페이스만 사용한 환경보다 약 20% 더 많은 패킷 전송을 할 수 있었다.

물이 토목섬유 사이의 접촉 전단강도에 미치는 영향 (The Effect of Water on the Interface Shear Strength between Geosynthetics)

  • 서민우;박준범;박인준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.321-328
    • /
    • 2002
  • Various geosynthetics used as liners or the Protection layers are installed in the solid waste landfill. The interface shear strength between geosynthetics installed at the slope of the landfill is a very important variable for the safe design of bottom and cover systems in the solid waste landfill. The interface shear strengths between (1) Geomembrane(GM)/Geotexile(GT) and (2) Geomembrane(GM)/Geosynthetic Clay Liner(GCL) were estimated by a large direct shear test in this study and were evaluated by the Mohr-Coulomb failure criterion. Especially, this research is focused on the effect of water which exists between geosynthetics because interfaces become easily wet or hydrated by rain, leachate and groundwater beneath liners. The strength reduction at large displacement and the effects of the magnitude of normal stresses and GCL hydration methods also investigated. The test results showed that the interface shear strength and shear behavior varied depending upon the magnitude of normal stresses, water at the interface, and hydration methods. Summary of secant friction angles, which could be used as reference values at a site where similar geosynthetics are installed, together with normal stress and hydration condition are presented.

  • PDF

FDS 기법과 HCIB법을 이용한 3차원 내면파 수치 모사 (NUMERICAL SIMULATION OF THREE-DIMENSIONAL INTERNAL WAVES USING THE FDS SCHEME ON THE HCIB METHOD)

  • 신상묵
    • 한국전산유체공학회지
    • /
    • 제17권1호
    • /
    • pp.8-15
    • /
    • 2012
  • A code developed using the flux-difference splitting scheme on the hybrid Cartesian/immersed boundary method is applied to simulate three-dimensional internal waves. The material interface is regarded as a moving contact discontinuity and is captured on the basis of mass conservation without any additional treatment across the interface. Inviscid fluxes are estimated using the flux-difference splitting scheme for incompressible fluids of different density. The hybrid Cartesian/immersed boundary method is used to enforce the boundary condition for a moving three-dimensional body. Immersed boundary nodes are identified within an instantaneous fluid domain on the basis of edges crossing a boundary. The dependent variables are reconstructed at the immersed boundary nodes along local normal lines to provide the boundary condition for a discretized flow problem. The internal waves are simulated, which are generated by an pitching ellipsoid near an material interface. The effects of density ratio and location of the ellipsoid on internal waves are compared.

SiCf/SiC 복합체의 특성에 미치는 열간가압소결 조건의 영향 (Effects of Hot Pressing Condition on the Properties of SiCf/SiC Composites)

  • 노비얀토 알피안;윤당혁
    • 한국세라믹학회지
    • /
    • 제48권5호
    • /
    • pp.335-341
    • /
    • 2011
  • Continuous SiC fiber-reinforced SiC-matrix composites ($SiC_f$/SiC) had been fabricated by electrophoretic infiltration combined with ultrasonication. Nano-sized ${\beta}$-SiC added with 12 wt% of $Al_2O_3-Y_2O_3$ additive and Tyranno$^{TM}$-SA3 fabric were used as a matrix phase and fiber reinforcement, respectively. After hot pressing at 5 different conditions, the density, microstructure and mechanical properties of $SiC_f$/SiC were characterized. Hot pressing at relatively severe conditions, such as $1750^{\circ}C$ for 1 and 2 h, resulted in a brittle fracture behavior due to the strong fiber-matrix interface in spite of their high flexural strength. On the other hand, toughened $SiC_f$/SiC composite could be achieved by hot pressing at milder condition because of the formation of weak interface in spite of the decreased flexural strength. These results proposed the importance of weak fiber-matrix interface in the fabrication of ductile $SiC_f$/SiC composite.

불연속 경계면을 갖는 광 방향성 결합기의 최적 결합효율을 위한 새로운 통합기준 (Novel Unified Criterion to Optimize Power Coupling at Optical Directional Couplers with Discontinuity Interface)

  • 호광춘
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2005년도 추계종합학술대회
    • /
    • pp.627-630
    • /
    • 2005
  • Novel unified criterion to optimize power coupling at optical directional couplers with discontinuous input/output interfaces is first defined and evaluated numerically. The numerical results reveal that maximum power transfer between guiding slabs without discontinuous interfaces is dominated by conventional phase-matching condition while the guiding structures with discontinuous interfaces has maximum power transfer at an equi-partition condition, which describes the power distribution condition between two rigorous modes propagating through optical couplers.

  • PDF

인터페이스 사용자 플랫폼의 구현을 위한 시각화 모듈 구성 (The Visualization Module Composition for Interface User Platform)

  • 김미연;서동조
    • 한국멀티미디어학회논문지
    • /
    • 제16권12호
    • /
    • pp.1482-1494
    • /
    • 2013
  • 이 연구개발의 결과 인터페이스 사용자 플랫폼은 최근 고도화된 인터페이스 기술의 특성을 반영하고 소셜 미디어에 의해 발생되는 정보를 활용하여 미래 도시에서 최적의 인터페이스 환경을 지원한다. 이는 미래 지능형 도시의 스마트 공간을 공간 사용자가 보다 쉽고 효율적인 인터페이스 환경에서 정보에 접근할 수 있도록 인터페이스 사용자 플랫폼 구성을 목적으로 하며, 플랫폼 구성을 위한 주요 모듈을 구성한다. 인터페이스 사용자 플랫폼 모듈은 시각화 서비스를 기본으로 하며, 시각화 에이전트, 시각화 소셜 네트워크, 시각 데이터, 시각 클래스, 시각화 아이콘, 시각지도, 시각화 서비스 등의 모듈로 구성된다. 본 연구에서는 전달하고자하는 정보를 포함하는 서비스 종류에 따라 적절한 인터페이스 기술을 적용할 수 있는 인터페이스 환경을 찾고자 본 연구의 최종 결과물인 "인터페이스 사용자 플랫폼"을 제시하였다.

지반-구조물 경계면의 루핑 포텐셜 평가 (Evaluation of Roofing Potential at the Ground-structure Interface)

  • 박정만;김강현;신종호
    • 한국지반환경공학회 논문집
    • /
    • 제19권3호
    • /
    • pp.25-33
    • /
    • 2018
  • 파이핑은 가장 대표적인 제방의 붕괴 유형으로 불투수성 수리구조물과 지반 경계면에서 Backward Erosion Piping인 루핑(Roofing)이 흔하게 발생한다. 루핑에 대한 검토는 주로 경험적 방법인 크립비를 이용하지만 이는 지반-구조물 경계면의 특성을 고려하지 않는 문제가 있다. 본 연구에서는 지반-구조물 경계면 특성이 루핑에 미치는 영향을 평가하기 위해 모형시험과 수치해석을 이용하여 파이핑 위험도를 고찰하였다. 모형시험에서 경계면 조도가 커질수록 파이핑 포텐셜이 감소함을 확인하였으며, 이를 수치해석에 적용하였다. 기존의 일반적인 수치해석방법은 수위차만을 고려하므로 경계면에서의 입자거동을 적절히 모사할 수 없다. 논문에서는 침투해석을 통해 침투력을 구하고, 입자해석기법을 이용해 파이핑의 입자거동을 모사한 침투-입자거동 연계해석을 수행하여 지반-구조물 경계면 조건에 따른 루핑 포텐셜을 조사하였다. 해석결과 경계면의 조도가 감소할수록 루핑 발생 확률이 증가함을 확인하였다.