• 제목/요약/키워드: Interface Unit

검색결과 621건 처리시간 0.027초

인터페이스 회로를 적용한 디젤기관의 배출가스특성에 관한 실험적 연구 (An Experimental Study on Diesel Engine of Exhaust Emission Characteristics by Interface Unit)

  • 한영출;김대열;백두성
    • 한국공작기계학회논문집
    • /
    • 제12권6호
    • /
    • pp.104-111
    • /
    • 2003
  • In order to collect the engine performance data and determine optimum engine conditions, engine performance test based on interface unit were tested This paper was carried out that engine' performance was developed using interface unit between personal computer and diesel engine. The results of the study are summarized as follows: Interface unit was developed. By using PAL, simulation was carried in order to logic's inspection. From this tea NO$_{x}$ were decreased, otherwise PM were increased. By using EGR system PM were increased by twice in the high load ranges, it was not seen to come into effect in the low load ranges. This system was tested D-l3 mode, the results were decreased more than 50% in the NO$_{x}$ emission.

CAN 기반 제어 시스템 분석을 위한 인터페이스 유닛 설계 및 구현 (Design and Implementation of an Interface Unit for Analysis of a CAN-Based Control System)

  • 박병률;정구민;안현식;김도현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.195-197
    • /
    • 2006
  • In this paper, an interface unit is designed to efficiently monitor transmission data in Controller Area Network(CAN)-based control systems. The CAN uses a serial multi master communication protocol that efficiently supports distributed real-time control with a very high level of data integrity, and communication speeds of up to 1Mbps. The interface unit is composed of a DSP controller which collects data on the CAN bus and transfers data to a personal computer via serial communication to save and display of interesting signals. The experimental system consists of three DSP controllers which represent electronic control units of a vehicle, an interface unit for analysing the data on the bus, and a graphic monitoring program coded on the Windows platform. The validity and the effectiveness of the proposed simple type of CAN interface unit are shown through the experimental results.

  • PDF

과학기술위성 2호 Reaction Wheel Assembly Interface Unit Proto Flight Model 개발 (Engineering Model Design and Implementation Proto Flight Model of Reaction Wheel Assembly Interface Unit for STSAT-2)

  • 김세일;강경인;이성호
    • 한국항공우주학회지
    • /
    • 제34권5호
    • /
    • pp.88-92
    • /
    • 2006
  • 과학기술위성 2호 사용되는 구동기인 반작용 휠(Reaction Wheel Assembly, RWA)과 위성 시스템을 연결해주는 인터페이스를 담당하는 Reaction Wheel Assembly Interface Unit(RIU)의 Proto Flight Model의 개발이 완료되고 동작시험을 마쳤다. RIU는 RWA에 공급되는 전원을 켜고 끄는 스위치와 명령을 주고 받는 위성탑재 컴퓨터(OBC)의 통신 회선을 선택하는 멀티플렉서, 그리고 RWA에 연결되는 물리적 통신라인으로 구성된다.

PLC 출력 구동을 위한 Wired Logic for Type Unit에 관한 연구 (A Study on Wired LogiC for Type Unit for PLC Output Driving)

  • 위성동;김태성
    • 전자공학회논문지T
    • /
    • 제36T권1호
    • /
    • pp.51-57
    • /
    • 1999
  • 본 논문은 온도센서 RSD. Pt 100Ω의 감지신호가 Temperature Controller의 릴레이 출력을 발생시키고 PLC 입력접점으로 입력시켜 1Scan Time으로 연산된 PLC 출력을 접점 P030에 Interface Unit를 연결시키므로 부하를 구동시키는 개발장비인 Wired Logic Type Unit에 대해서 기술하였다. 현재 PLC 교육장에서 프로그램 되어진 PLC가 부하를 구동시킬 수 있는 국내의 교육 PLC Test Kit로는 PLC와 부하 사이에 Interface 과정이 무시된 상태에서 PLC의 교육을 하도록 되어있다. 개발 키 트는 이 점을 보안하기 위해서 각종 센서 중 전자에서 언급한 온도 센서 Pt 100Ω을 이용한 온도 제어기의 릴레이 출력이 PLC 입력으로 피드백 되었을 때, 연산된 PLC 출력접점에 WLTU를 삽입시켜 PC, PLC와 부하 사이에 실시간 시스템으로 구동 시킬 수 있는 설비로, PLC 사용의 핵심원리를 쉽게 이해하고 알아 볼 수 있었다. 부하 Interface Unit인 WLTU의 구성은 구동 부분인 유 접점, 무접점, 센서, 지시 등, A접점, B접점 부하인 Motor로 나누었다.

  • PDF

Mini-MAP을 채택한 토큰-패싱 버스 네트워크의 MAC계층 구현에 관한 연구 (A Study on the Implementation of MAC Layer of Token-passing Bus Network Based on Mini-MAP)

  • 강문식;조병선;박민용;이상배
    • 전자공학회논문지B
    • /
    • 제28B권5호
    • /
    • pp.404-410
    • /
    • 1991
  • In this paper,a network interface unit of token-passing bus network and its driving software are implemented based on Mini-MAP. This network interface unit performs the function of MAC layer which is responsible for transmission and reception of frames as well as the management of logical ring. The driving software performs the management of data buffer and the report of errors, if ocoured, to the higher layer. Motorola MC68824 of is used as a TBC(Token Bus Controller) and Intel80186 as a CPU for network interface unit. The operation of network interface unit is verified by self-test which checks the functioning of TBC and CPU. In addition each module of driving software is tested to check the functions regarding transmission and reception of frames.

  • PDF

PC에서 유닛 제어를 위한 다중 스마트폰의 통신 인터페이스 연구 (Study on Communication Interface of Multiple Smartphones for Unit Control in a PC)

  • 정하민;김동헌
    • 제어로봇시스템학회논문지
    • /
    • 제19권6호
    • /
    • pp.520-526
    • /
    • 2013
  • This study presents the unit control of a PC (Personal Computer) program using multiple smartphones based on ad hoc communication. A design of the data packet that multiple smartphones send to a computer, and a framework that manages and controls the unit in a computer after analyzing the data packet, are proposed. As a result, multiple users are able to control their own units using their smartphones while seeing the monitor connected to a computer. In other words, multiple users can share the same game in a computer or control their units embedded in a system using their smartphones. An experimental result shows that a racing game in a PC can be realized by the proposed communication interface, where four iPhones are used to control their units in a computer. Thus, the proposed framework can be effectively used for unit control in a PC using multiple smartphones.

서비스 가로채기가 있는 네트워크 접속장치내의 유한버퍼의 분석 (Analysis of a finite buffer with service interruption in a network interface unit)

  • 김영한
    • 전자공학회논문지A
    • /
    • 제33A권2호
    • /
    • pp.1-7
    • /
    • 1996
  • In this paper, we analyzed the packet blocking probability of a finite buffer in a network interface unit. In general, a network interface unit which provides a means of interface between the network and computer has a microprocessor and a protocol processor for the network access protocols. It also has a receive buffer for the arriving packets from the network which is served by the microprocessor with service interruption by the protocol processor. In this paper, we modeled the receive buffer as a discrete time server with service interruption, and obtained the packet blocking probability using the mini-slot approximation.

  • PDF

32비트 멀티미디어 RISC CPU를 위한 버스 인터페이스 유닛의 설계 (VLSI design of a bus interface unit for a 32bit RISC CPU)

  • 조영록;안상준;이용석
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 하계종합학술대회논문집
    • /
    • pp.831-834
    • /
    • 1998
  • This paper describes a bus interface unit which is used in a 32bit high-performance multimedia RISC CPU including DSP unit. The main idea adopted in designing is that the bus interface unit enables the processor to provide on-chip functions for controlling memory and peripheral devices, including RAS-cAS multiplexing, DRAM refresh and parity generation and checking. The number of bus cycles used for a memory or I/O access is also defined by the processor, thus, no external bus controllers are required. All memories and peripheral devices can be connected directly, pin to pin, without any glue logic. That is the key point of the design.

  • PDF

전역적 비동기 지역적 동기 시스템을 위한 고성능 비동기식 접속장치 (A High Performance Asynchronous Interface Unit for Globally-Asynchronous Locally-Synchronous Systems)

  • 오명훈;박석재;최호용;이동익
    • 대한전자공학회논문지SD
    • /
    • 제40권5호
    • /
    • pp.321-334
    • /
    • 2003
  • GALS(Globally-Asynchronous Locally-Synchronous) 시스템은 대규모의 칩 설계 시에 설계의 용이성과 신뢰성을 확보할 수 있는 구조로 주목 받고 있다. 본 논문에서는 GALS 시스템에 필수적인 비동기 접속장치를 제안한다. 접속 장치는 크게 센더 모듈과 리시버 모듈로 구성되어 있으며, 센더 모듈에서는 부분적으로 내부 클록과는 무관하게 데이터 전송이 가능하다. 0.25um 공정의 게이트 레벨 표준 셀 라이브러리를 사용하여 설계하였고, 성능 향상 정도를 시뮬레이션을 통하여 예측할 수 있었다. 마지막으로, 접속장치를 장착한 GALS 구조의 예제 회로를 설계하여 올바르게 동작함을 확인하였다.