• Title/Summary/Keyword: Interchangeability Standard

Search Result 12, Processing Time 0.034 seconds

Obviousness Standard and Ease of Interchangeability in the Doctrine of Equivalents (기술혁신의 관점에서 본 균등요건의 치환자명성과 특허요건의 진보성의 관계)

  • Koo, Dae-Hwan
    • Journal of Legislation Research
    • /
    • no.41
    • /
    • pp.201-228
    • /
    • 2011
  • In 97hu2200, the Supreme Court of Korea suggested five requirements to apply the doctrine of equivalents, i.e. identity of problem-solving principles, interchangeability, ease of interchangeability, exception of known arts and file-wrapper estoppel. There have been arguments on whether the standard of ease of interchangeability could be regarded as the same as the obviousness standard in deciding patentability. The side who thinks that they are different (hereinafter, the side of difference) considers that the standard of ease of interchangeability is narrower than the obviousness standard. This side criticizes the side who thinks that they are the same each other (hereinafter, the side of the same) on the reason that doctrine of equivalents can be overly expanded. On the other hand, 'the side of the same' argues that every accused invention having no inventive step from the perspective of the patented invention should be considered to infringe. 'The side of the same' points that if the standard of ease of interchangeability is considered as narrower than the obviousness standard, 'grey area' should exist where the patent law cannot work. The difference between the two side may cause contradictory results in the decision of infringement under the doctrine of equivalents. Because 'the side of difference' construes claims narrowly than 'the side of the same,' an accused invention in the grey area is not regarded to infringe. 'The side of the same,' however, considers the accused invention to fall into the scope of the patent under the doctrine of equivalents. This paper concludes that the standard of ease of interchangeability should be regarded as the same as the obviousness standard from the perspective of economics of innovation.

Study on the Thermodynamic Properties and Combustion Information of Natural Gases from Various Producing Districts (산지별 천연가스들의 열 물성치 및 연소 정보 검토)

  • Lee, Chang-Eon;Hyun, Seung-Ho;Hwang, Cheol-Hong;Lee, Sung-Min;Ha, Young-Cheol;Lee, Kang-Jin
    • Journal of the Korean Society of Combustion
    • /
    • v.12 no.1
    • /
    • pp.38-47
    • /
    • 2007
  • The diversification of import districts of natural gas is trying to prepare an increase in the demand and price. The interchangeability of natural gases should be examined prior to supply to gas appliances, although compositional differences among natural gases are not large. The object of this study is to investigate numerically the thermodynamic and transport properties as well as information on combustion of 6 natural gases. Comparing the properties of BOG1 with those of standard gas, the maximum differences of heating value, Wobbe index, air-fuel ratio, and specific heat are 10%, 4%, 10% and 5.54%, respectively. That is, the BOG1 is required careful application. However, all gases except for BOG1 show the similar properties with standard gas. Finally, the combustion information such as flame temperature and burning velocity are examined. These results will provide the useful information related to the interchangeability of various natural gases in practical combustion appliances.

  • PDF

Experimental Study on the Flame Stable Region of Natural Gases from Various Producing Districts (산지별 천연가스의 화염 안정영역에 관한 실험적 연구)

  • Lee, Chang-Eon;Hong, Sung-Chang;Jeong, Young-Sik;You, Hyun-Seok;Lee, Seung-Jun;Her, Jae-Young;Hwang, Cheol-Hong
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.69-75
    • /
    • 2007
  • In this study, the difference of flame stability zone for natural gases from producing districts was studied experimentally using a new type of flame stability diagram. The similarity of stable flame zone between a domestic appliance and an interchangeability test(IT) burner is also examined. As a result, the stable flame zones expressed by limits curves of flame lifting and yellow tipping show the similar results in a domestic gas range and IT burner. Furthermore, IT burner can reproduce the flash back phenomena and show the distinct difference of fuel type as the burner diameter is increased. To suggest the new type of flame stability diagram in the respect of fuel interchangeability, the air flowrate and Wobbe fuel flowrate were adopted as axis coordinates. It can be identified that the new diagram can provide the useful information on the difference of flame stability zone, heat input rate and air-fuel ratio when a fuel is altered to other fuels under the identical operating conditions. Finally, the stable flame zones for natural gas of 6 type are compared, and the detailed information to use as the interchangeability fuels of standard natural gas is provided using the new type of flame stability diagram.

  • PDF

Analyses on Standard Formats of Spatial Imagery Information (공간영상정보 포맷 분석 및 표준화 방향)

  • 임정호;사공호상;권용대
    • Spatial Information Research
    • /
    • v.9 no.1
    • /
    • pp.31-50
    • /
    • 2001
  • This study has analyzed GeoTIFF, SDTS, HDF, and BIIF as the representative formats of spatial imagery information with two parts. First is to compare 4 formats with each other based on 4 comparison criteria (extensibility, interchangeability, current widespread use, long-term stability) by analyzing specification of each format. Second is to estimate current use and interchangeability of 4 formats between 5 commercial softwares used commonly. The result shows that GeoTIFF is currently better than three other formats. However, the more various spatial imagery information are and the larger capacity they have, the more formats are developed and updated, which means that only one format should not be considered as a standard format continuously. It is better to provide a standard format proper to the time through continuous research and sustainable policy support should be followed.

  • PDF

Estimation Method of the Interchangeability Using Equivalent Gases in a Partial Premixed Gas Appliance (등가가스를 이용한 부분예혼합 가스기기의 호환성 판정법)

  • Kim, Jong-Min;Lee, Seung-Ro;Ha, Young-Cheol;Lee, Sung-Min;Lee, Chang-Eon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.8
    • /
    • pp.761-766
    • /
    • 2010
  • The estimation method of the interchangeability in a partial premixed appliance about various compositions of natural gases using equivalent gases, experimentally. The results of the experiment in which equivalent gases were used compared with those obtained in experiments in which natural gases were used; Images of flames, lift-off limits, CO emissions, and incomplete combustion indices in KS standard for the domestic gas range were considered. From the comparison, it was observed that the length and color of the flame of the equivalent gases were almost the same as those of imported natural gases. Further, in the case of gases with Wobbe indices greater than 51 MJ/$m^3$, the KS standard for lifting limits was satisfied. Furthermore, in the case of gases with Wobbe indices less than 56.3 MJ/$m^3$, the CO mole fractions are in the range 95-100 ppm. Hence, the range of Wobbe indices 51-56.3 MJ/$m^3$ was proposed to be the range for interchangeability from the points of view of lifting limits and incomplete combustion, as prescribed in the domestic gas range in the case of imported natural gases.

Construction of Korean Korea CALS Standardization (한국적 CALS 표준화 구축방안)

  • 김철환;김규수;신영인
    • The Journal of Society for e-Business Studies
    • /
    • v.1 no.1
    • /
    • pp.117-140
    • /
    • 1996
  • CALS is recognized as a national response to the new chapter of information society. It is essential that the standardization in Korea should be constructed compatible with not only domestic but also international standardization trend. This study aims to propose a proper direction of CALS standardization in Korea, based on the international CALS standardization movement. This paper classifies standard into five types and provides a proper direction and guidance far each standard. As a trend of CALS standard, all ten data files are converted using SGML standard far the interchangeability of data among heterogenous systems. CAD and Graphic data arc also moving toward to the STEP as their standard. In this regard, this paper discusses how to implement SGML and STEP Model. Finally, this paper proposes a method how to construct an EDI system with CALS standard and how to establish a standard authorization institute which will be responsible far the standard authorization. Furthermore, this paper also proposes the CALS Test Network (CTN) as its experimental method.

  • PDF

Substation Automation System Design Process Based on IEC 61850 SCL (IEC 61850 SCL기반 변전소 자동화 시스템의 구성방법)

  • Zhang, Da-Peng;Rim, Seong-Jeong;Lee, Seung-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.62-64
    • /
    • 2006
  • With the advent of the international standard IEC 61850 for communication networks and systems in substations, utilities are beginning to implement substation automation systems (SAS) that can give support to interoperability, interchangeability and self-description features. This paper describes with the SAS design accordance with this new standard. After a brief introduction of IEC 61850 SCL, this paper addresses some issues related to the specification of an IEC 61850 based SAS, and describes the Substation Configuration Language (SCL) based on Extensible Markup Language (XML). The SAS design process is explored with examples including the Intelligent Electronic Device (IED) selection, Logical Nodes (LN) allocation and the related services and the SAS communication architecture.

  • PDF

Technical Trend on Standarization and Development of Mobile Fuel Cell (휴대용 연료전지 개발 및 표준화 동향)

  • Cho, Hye-Jung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.335-335
    • /
    • 2009
  • 산업의 고도화에 따라 소비자들이 사용하는 전기, 전자기기의 사용시간 연장에 대한 욕구가 강해지고 있으며, 이에 따라 기존 2차전지의 용량을 극대화하는 연구와 더불어 차별화하여 장시간 안정적으로 사용할 수 있는 신규 전원 개발이 요구되어 진다. 연료전지는 이러한 욕구를 충족시킬 수 있는 차세대 전지로서 충전 대기 시간 없이 연료의 교체만으로 언제 어디서나 전력을 공급할 수 있으며, 장시간 대용량이 요구되는 Outdoor 응용분야에서는 1, 2차 전지대비 무게/부피 에너지밀도(Wh/kg, Wh/L)와 에너지 비용($/Wh, \/Wh)면에서 높은 경쟁력을 가지고 있다. 이러한 휴대용 연료전지의 최근 개발동향을 소형 전자기기용 충전기, 산업용 UPS, APU 및 군사용 이동전원 분야로 나누어 소개하고자 한다. 또한, 이동용과 휴대용 연료전지에 대한 국제 연료전지 표준화기구의 최근 국제규격에 대해 소개하며, 이를 통해 대두되고 있는 기술적 이슈와 함께 국내 표준규격 채택에 필요한 제안을 하고자 한다. 국제표준화 분과위원회 (WG 7, 8, 9, 10)의 2009년 이후 표준화 활동계획을 공유함으로써 관련 연구개발 및 상용화 업체들의 이해를 돕고자 한다.

  • PDF

Developing Data Exchange Standard between Roadside-device and Traffic Information Center in accordance with ISO 15784 (ISO 15784를 적용한 교통정보센터와 노변장치간 데이터 교환 표준 개발 _ AVI를 중심으로)

  • Lee, Sang-Hyun;Son, Seung-Neo;Kim, Nam-Sun;Cho, Yong-Sung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.3
    • /
    • pp.29-41
    • /
    • 2013
  • This study set out to developing data exchange standard between roadside device and traffic information center fitted in a domestic environment by applying international standard ISO 15784. First, we defined message basic concept of 'Dialog' and essential elements should be defined to define the standard message for securing system compatibility by reference ISO 14817 and ISO 14827 Part 1. For defining standard message items exchanged between AVI and traffic information center, we formed Working Group under ITS Standards Technical Committee and analyzed data flow for ITS National Architecture, Standard messages of existing standards, and AVI operation messages actually operated on roadside now. So, we extracted 14 functionally needed messages and defined 28 standard messages adopting 'Dialog' concept. In case of the application protocol for data exchange standards, we defined basic requirements for securing interoperability and interchangeability considering domestic environment by analyzing reference standard of ISO 15784.

A Study on Communication Driver for Substation Automation based on IEC 61850 (IEC 61850 기반의 디지털 변전소를 위한 통신 드라이버에 관한 연구)

  • Lee, Yil-Hwa;Choi, Chul-Hwan;Han, Jin-Hee;Chun, Tae-Young;Shin, Yang-Hark
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.111-113
    • /
    • 2006
  • Substation automation is one of the key issues for the enhancement of the power industrial foundation. IEC 60850 is an international standard specifying communication network and systems in substation. It supports interchangeability and interoperability of equipments from different vendors. ACSI(Abstract communication service interface) specifies basic communication structure for substation and IEDs. It supports communication as well as various services without proper protocols. For actual communication, MMS(Manufacturing Message Specification : ISO 9506) is used to map ACSI services. Solutions for the development of communication driver based don IEC 61850 are proposed in this paper.

  • PDF