• 제목/요약/키워드: Interbody fusion

검색결과 147건 처리시간 0.029초

What are the Differences in Outcome among Various Fusion Methods of the Lumbar Spine?

  • Kang, Suk-Hyung;Kim, Young-Baeg;Park, Seung-Won;Hong, Hyun-Jong;Min, Byung-Kook
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권1호
    • /
    • pp.39-43
    • /
    • 2005
  • Objective: For Posterior lumbar interbody fusion(PLIF) various cages or iliac bone dowels are used with or without pedicle screw fixation(PSF). To evaluate and compare the clinical and radiological results of different fusion methods, we intend to verify the effect of added PSF on PLIF, the effect of bone cages and several factors which are thought to be related with the postoperative prognosis. Methods: One hundred and ninety seven patients with lumbar spinal stenosis and instability or spondylolisthesis underwent various fusion operations from May 1993 to May 2003. The patients were divided into five groups, group A (PLIF with autologous bone dowels, N=24), group B (PLIF with bone cages, N=13), group C (PLIF with bone dowels and PSF, N=37), group D (PLIF with bone cages and PSF, N=30) and group E (PSF with intertransverse bone graft, N=93) for comparison and analyzed for the outcome and fusion rate. Results: Outcome was not significantly different among the five groups. In intervertebral height (IVH) changes between pre- and post-operation, Group B ($2.42{\pm}2.20mm$) was better than Group A ($-1.33{\pm}2.05mm$). But in the Group C, D and E, the IVH changes were not different statistically. Fusion rate of group C, D was higher than that of Group A and B. But the intervertebral height(IVH) increased significantly in group B($2.42{\pm}2.20mm$). Fusion rate of group C and D were higher than that of group A and D. Conclusion: Intervertebral cages are superior to autologous iliac bone dowels for maintaining intervertebral height in PLIF. The additional pedicle screw fixation seems to stabilize the graft and improve fusion rates.

Comparison between Instrumented Mini-TLIF and Instrumented Circumferential Fusion in Adult Low-Grade Lytic Spondylolisthesis : Can Mini-TLIF with PPF Replace Circumferential Fusion?

  • Kim, Jin-Sung;Kim, Dong-Hyun;Lee, Sang-Ho
    • Journal of Korean Neurosurgical Society
    • /
    • 제45권2호
    • /
    • pp.74-80
    • /
    • 2009
  • Objective : To evaluate clinical and radiological results of two different fusion techniques in adult low-grade isthmic spondylolisthesis. Methods : Between November 2003 and December 2004, 46 consecutive patients underwent instrumented mini-transforaminal lumbar interbody fusion (mini-TLIF) (group I) at Wooridul Spine Hospital, Seoul, Korea. Between February 2003 and October 2006, 32 consecutive patients underwent instrumented circumferential fusion (group II) at Leon Wiltse Memorial Hospital, Suwon, Korea. The mean follow-up periods were 29.7 and 26.1 months, respectively. Results : Mean visual analog scale (VAS) scores for back and leg pain decreased, respectively, from 6.98 and 6.33 to 2.3 and 2.2 in group I and from 7.38 and 6.00 to 1.7 and 1.0 in group II. Mean Oswestry disability index (ODI) improved from 51.85% to 14.4% in group I and from 60% to 9.1% in group II. In both groups, VAS and ODI scores significantly changed from pre- to postoperatively (p<0.001), but postoperative outcome between groups was statistically not significant. Radiologic evidence of fusion was noted in 95.7% and 100% of the patients in group I and II, respectively. In both groups, changes in disc height, segmental lordosis, degree of listhesis, and whole lumbar lordosis between the pre- and postoperative periods were significant except whole lumbar lordosis in both groups. Conclusion : Clinical and functional outcomes demonstrate no significant differences between groups in treating back and leg pain of adult patients with low-grade isthmic spondylolisthesis. However, in terms of operative data (i.e. operation time and hospital stay), instrumented mini-TLIF demonstrated better results.

FEM을 이용한 Cage 삽입 시 안정성에 관한 연구 (A study on the placing cage stability using FEM)

  • 박기훈;박정호;조우석;김현수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1364-1367
    • /
    • 2003
  • These days, spinal interbody arthrodesis using fusion cage is very popular. The cage used for the spinal interbody arthrodesis is mainly inserted from the posterior of the spine. Accordingly, there could possibly occur damages at posterior and results in instability of structure. Moreover, one or two cages are inserted depending on the patients. In this study, it is attempted to evaluate the stability quantitatively by comparing two cases where one and two cages are inserted. For this purpose, a very fine 3-dimensional finite element model of vertebra is generated from the MRI data. From this vertebra model, two models are made: one with one cage and the other with two cages. Finally, finite element analys is performed for these two models and both of the mechanical behaviors are examined In addition, the effect on the stability is evaluated and compared quantitatively.

  • PDF

A Surgical Option for Multilevel Anterior Lumbar Interbody Fusion with Ponte Osteotomy to Achieve Optimal Lumbar Lordosis and Sagittal Balance

  • Suh, Loo-Ree;Jo, Dae-Jean;Kim, Sung-Min;Lim, Young-Jin
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권4호
    • /
    • pp.365-371
    • /
    • 2012
  • Objective : To document lumbar lordosis (LL) of the spine and its change during surgeries with the different height but the same angle setting of the anterior cage. Additionally, we attempted to determine if sufficient LL is achieved at different cage heights and to quantify the change in LL during multi-level anterior lumbar interbody fusion (ALIF). Methods : The medical records and radiographs of 42 patients who underwent more than 2 level ALIFs between 2008 and 2009 were retrospectively reviewed. We evaluated 3 parameters seen on lateral whole spine radiographs : LL, pelvic incidence (PI), and sagittal vertical axis (SVA). The mean follow-up time was 28.1 months and the final follow-up radiographs of all patients were reviewed at least 2 years after surgery. Statistical analysis was performed using the paired t-tests. Results : Lumbar lordosis had changed up to 30 degrees immediately and 2 years after surgery (preoperative mean LL, SVA : 22.45 degrees, 112.31 mm; immediate postoperative mean LL, SVA : 54.45 degrees, 37.36 mm; final follow-up mean LL, SVA : 49.56 degrees, 26.95 mm). Our goal of LL is to obtain as much PI as possible, preoperative mean PI value was $55.38{\pm}3.35$. The pre-operative and two year post-surgery follow-up mean of the Japanese Orthopedic Association score were $9.2{\pm}0.6$ and $13.2{\pm}0.6$ (favorable outcome rate : 95%), respectively. In addition, we were able to obtain good clinical outcomes and sagittal balance with a subsidence rate of 22.7%. Conclusion : We were able to achieve sufficient LL, such that it was similar to the PI, utilizing multi-level ALIF with the use of a tall cage with the same angle setting of the cage. We have found out that achieving sufficient lumbar lordosis and sagittal balance require an anterior lumbar cage with high angle and height.

A Morphometric Analysis of Neuroforamen in Grade I Isthmic Spondylolisthesis by Anterior Lumbar Interbody Fusion with Pedicle Screw Fixation

  • Lee, Dong-Yeob;Lee, Sang-Ho;Kim, Seok-Kang;Maeng, Dae-Hyeon;Jang, Jee-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • 제41권6호
    • /
    • pp.377-381
    • /
    • 2007
  • Objective : The aim of this study was to evaluate the morphometric changes in neuroforamen in grade I isthmic spondylolisthesis by anterior lumbar interbody fusion [ALIF]. Methods : Fourteen patients with grade I isthmic spondylolisthesis who underwent single level ALIF with percutaneous pedicle screw fixation were enrolled. All patients underwent standing lateral radiography and magnetic resonance imaging [MRI] before surgery and at 1 week after surgery. For quantitative analysis, the foraminal height, width, epidural foraminal height, epidural foraminal width, and epidural foraminal area were evaluated at the mid-portion of 28 foramens using T2-weighted sagittal MRI. For qualitative analysis, degree of neural compression in mid-portion of 28 foramens was classified into 4 grades using T2-weighted sagittal MRI. Clinical outcomes were assessed using Visual Analogue Sale [VAS] scores for leg pain and Oswestry disability index before surgery and at 1 year after surgery. Results : The affected levels were L4-5 in 10 cases and L5-S1 in 4. The mean foraminal height was increased [p<0.001], and the mean foraminal width was decreased [p=0.014] significantly after surgery. The mean epidural foraminal height [p<0.001], epidural foraminal width [p<0.001], and epidural foraminal area [p<0.001] showed a significant increase after surgery. The mean grade for neural compression was decreased significantly after surgery [p<0.001]. VAS scores for leg pain [p=0.001] and Oswestry disability index [p=0.001] was decreased significantly at one year after surgery. Conclusion : Foraminal stenosis in grade I isthmic spondylolisthesis may effectively decompressed by ALIF with percutaneous pedicle screw fixation.

Does the Access Angle Change the Risk of Approach-Related Complications in Minimally Invasive Lateral Lumbar Interbody Fusion? An MRI Study

  • Huang, Chunneng;Xu, Zhengkuan;Li, Fangcai;Chen, Qixin
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권6호
    • /
    • pp.707-715
    • /
    • 2018
  • Objective : To investigate the potential risk of approach-related complications at different access angles in minimally invasive lateral lumbar interbody fusion. Methods : Eighty-six axial magnetic resonance images were obtained to analyze the risk of approach-related complications. The access corridor were simulated at different access angles and the potential risk of neurovascular structure injury was evaluated when the access corridor touching or overlapping the corresponding structures at each angle. Furthermore, the safe corridor length was measured when the corridor width was 18 and 22 mm. Results : When access angle was $0^{\circ}$, the potential risk of ipsilateral nerve roots injury was 54.7% at L4-L5. When access angle was $45^{\circ}$, the potential risk of abdominal aorta, contralateral nerve roots or central canal injury at L4-L5 was 79.1%, 74.4%, and 30.2%, respectively. The length of the 18 mm-wide access corridor was largest at $0^{\circ}$ and it could reach 44.5 mm at L3-L4 and 46.4 mm at L4-L5. While the length of the 22 mm-wide access corridor was 42.3 mm at L3-L4 and 44.1 mm at L4-L5 at $0^{\circ}$. Conclusion : Changes in the access angle would not only affect the ipsilateral neurovascular structures, but also might adversely influence the contralateral neural elements. It should be also noted to surgeons that alteration of the access angle changed the corridor length.

Anterior Lumbar Interbody Fusion with Stand-Alone Interbody Cage in Treatment of Lumbar Intervertebral Foraminal Stenosis : Comparative Study of Two Different Types of Cages

  • Cho, Chul-Bum;Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • 제47권5호
    • /
    • pp.352-357
    • /
    • 2010
  • Objective : This retrospective study was performed to evaluate the clinical and radiological results of anterior lumbar interbody fusion (ALIF) using two different stand-alone cages in the treatment of lumbar intervertebral foraminal stenosis (IFS). Methods : A total of 28 patients who underwent ALIF at L5-S1 using stand-alone cage were studied [Stabilis$^{(R)}$ (Stryker, Kalamazoo, MI, USA); 13, SynFix-LR$^{(R)}$ (Synthes Bettlach, Switzerland); 15]. Mean follow-up period was 27.3 ${\pm}$ 4.9 months. Visual analogue pain scale (VAS) and Oswestry disability index (ODI) were assessed. Radiologically, the change of disc height, intervertebral foraminal (IVF) height and width at the operated segment were measured, and fusion status was defined. Results : Final mean VAS (back and leg) and ODI scores were significantly decreased from preoperative values (5.6 ${\pm}$ 2.3 ${\rightarrow}$ 2.3 ${\pm}$ 2.2, 6.3 ${\pm}$ 3.2 ${\rightarrow}$1.6 ${\pm}$ 1.6, and 53.7 ${\pm}$ 18.6 ${\rightarrow}$ 28.3 ${\pm}$ 13.1, respectively), which were not different between the two devices groups. In Stabilis$^{(R)}$ group, postoperative immediately increased disc and IVF heights (10.09 ${\pm}$ 4.15 mm ${\rightarrow}$ 14.99 ${\pm}$ 1.73 mm, 13.00 ${\pm}$ 2.44 mm ${\rightarrow}$ 16.28 ${\pm}$ 2.23 mm, respectively) were gradually decreased, and finally returned to preoperative value (11.29 ${\pm}$ 1.67 mm, 13.59 ${\pm}$ 2.01 mm, respectively). In SynFix-LR$^{(R)}$ group, immediately increased disc and IVF heights (9.60 ${\pm}$ 2.82 mm ${\rightarrow}$ 15.61 ${\pm}$ 0.62 mm, 14.01 ${\pm}$ 2.53 mm ${\rightarrow}$ 21.27 ${\pm}$ 1.93 mm, respectively) were maintained until the last follow up (13.72 ${\pm}$ 1.21 mm, 17.87 ${\pm}$ 2.02 mm, respectively). The changes of IVF width of each group was minimal pre- and postoperatively. Solid arthrodesis was observed in 11 patients in Stabilis group (11/13, 84.6%) and 13 in SynFix-LR$^{(R)}$ group (13/15, 86.7%). Conclusion : ALIF using stand-alone cage could assure good clinical results in the treatment of symptomatic lumbar IFS in the mid-term follow up. A degree of subsidence at the operated segment was different depending on the device type, which was higher in Stabilis$^{(R)}$ group.

The Formation of Extragraft Bone Bridging after Anterior Cervical Discectomy and Fusion : A Finite Element Analysis

  • Kwon, Shin Won;Kim, Chi Heon;Chung, Chun Kee;Park, Tae Hyun;Woo, Su Heon;Lee, Sung-Jae;Yang, Seung Heon
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권6호
    • /
    • pp.611-619
    • /
    • 2017
  • Objective : In addition to bone bridging inside a cage or graft (intragraft bone bridging, InGBB), extragraft bone bridging (ExGBB) is commonly observed after anterior cervical discectomy and fusion (ACDF) with a stand-alone cage. However, solid bony fusion without the formation of ExGBB might be a desirable condition. We hypothesized that an insufficient contact area for InGBB might be a causative factor for ExGBB. The objective was to determine the minimal area of InGBB by finite element analysis. Methods : A validated 3-dimensional, nonlinear ligamentous cervical segment (C3-7) finite element model was used. This study simulated a single-level ACDF at C5-6 with a cylindroid interbody graft. The variables were the properties of the incorporated interbody graft (cancellous bone [Young's modulus of 100 or 300 MPa] to cortical bone [10000 MPa]) and the contact area between the vertebra and interbody graft (Graft-area, from 10 to $200mm^2$). Interspinous motion between the flexion and extension models of less than 2 mm was considered solid fusion. Results : The minimal Graft-areas for solid fusion were $190mm^2$, $140mm^2$, and $100mm^2$ with graft properties of 100, 300, and 10000 MPa, respectively. The minimal Graft-areas were generally unobtainable with only the formation of InGBB after the use of a commercial stand-alone cage. Conclusion : ExGBB may be formed to compensate for insufficient InGBB. Although various factors may be involved, solid fusion with less formation of ExGBB may be achieved with refinements in biomaterials, such as the use of osteoinductive cage materials; changes in cage design, such as increasing the area of polyetheretherketone or the inside cage area for bone grafts; or surgical techniques, such as the use of plate/screw systems.

경추 물림 금속판을 이용한 경추 전방추체간 유합술 (Anterior Cervical interbody Fusion with Cervical Spine Locking Plate)

  • 박주태;안길영;이영태;안면환
    • Journal of Yeungnam Medical Science
    • /
    • 제14권1호
    • /
    • pp.209-219
    • /
    • 1997
  • 포항 성모병원 정형외과에서 실시한 경추 전방유합술 및 A-O금속판 고정술을 병행하여 치료하고 13개월이상(평균 20개월) 추시가 가능하였던 경추 추간판 탈출증 환자 11례 및 외상환자 3례를 대상으로 관찰하여 다음과 같은 결과를 얻었다. 1. 경추 추간판 탈출 환자 11례 중 상지 방사통을 호소한 경우가 8례이었으며 감각 둔화 및 근력약화를 호소한 환자가 3례이었다. 2. 외상의 기전으로는 굴곡 회전손상 3례이었다. 3. 고정범위는 1개 분절고정이 12례, 두개 분절고정이 2례이었으며 술후 분절수에 관계없이 필라델피아 보조기를 이용해 조기 보행을(평균 2일) 시작하였으며 이러한 조기 보행으로 인한 불편함의 호소는 없었다. 4. 골유합은 이종골을 사용한 1례에서의 불유합을 보였으나, 동종골을 사용한 13례에서는 전례 모두 유합(평균 12주)을 보임으로 이종골 보다는 동종골의 이식에서 높은 유합율을 보였다. 5. 추간판 탈출환자 전례에서 증상의 호전이 있었으며 불완전 마비가 있었던 외상환자 3례에서도 술후 추시 기간 중 Frankel분류상 B에서 C등급으로 호전되었다. 6. 술후 합병증은 금속판 파열 1례 및 일시적인 사성 2례를 제외한 환부 혈종이나 나사못 파열 등의 다른 합병증은 관찰되지 않았다. 이상의 결과를 종합해 보면 전방 도달법에 의한 전방유합술 및 물림나사와 금속판을 이용해 시술한 경추 추간판 탈출증 및 외상 환자에 있어서 수술적 치료가 안전하고 압박된 신경에 대한 감압, 충분한 안정성 확보로 인한 외고정 기간의 단축 및 신속한 골유합을 기대할 수 있는 방법이며 기존의 금속판과 달리 후방 피질골을 관통하지 않기 때문에 척수의 손상을 피할수 있으며 수술중 방사선 피폭량도 줄일수 있어 권장할 만한 방법으로 사료된다.

  • PDF