• Title/Summary/Keyword: Inter-harmonics

Search Result 16, Processing Time 0.024 seconds

Modification of IEC Flickermeter to Measure the Flicker Caused by Inter-Harmonics (상호고조파에 의한 플리커의 측정에 가능한 IEC 플리커미터의 설계)

  • Cho, Soo-Hwan;Jung, Jae-Ahn;Jang, Gil-Soo;Kwon, Sae-Hyuk
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.69-70
    • /
    • 2007
  • Now the IEC flicker measuring algorithms and its flicker index of $P_{st}$ and $P_{lt}$ are accepted internationally as standards. But it is recently found that IEC flickermeter has a main drawback that it cannot afford to detect the fluctuating patterns of voltage envelope caused by interharmonics higher than 102Hz in the 60Hz power system. This is brought about by two components of IEC flicker measuring steps, squaring and low-pass filtering. This paper presents the innate defect of IEC flickermeter and proposes a modified measuring method considering the voltage flickers by subharmonics and interharmonics.

  • PDF

A Highly Linear and Efficiency Class-F Power Amplifier using PBG and application EER Structure (EER 구조의 응용과 PBG를 이용한 고효율, 고선형성 Class-F 전력 증폭기)

  • Lee, Chong-Min;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.2
    • /
    • pp.81-86
    • /
    • 2007
  • In this paper, the Power Added Efficiency (PAE) and linearity of class-F PA has been improved by using the PBG structure and the application of EER structure, simultaneously. The adaptive bias control circuit has been employed to improve the PAE through the application of EER structure. The PBG structure has been adapted for improving the Linearity by suppressing the harmonics on the output of amplifier. The PAE and the 3rd Inter-Modulation Distortion (IMD) has improved 34.56%, 10.66 dB, compared with those of the conventional Doherty amplifier, respectively.

LTE-Advanced CA Features in 3GPP REL-12 and its Future (LTE-Advanced CA 기술 특징 및 진화 방향)

  • Lim, Su Hwan;Lee, Sang-Wook
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39A no.9
    • /
    • pp.497-507
    • /
    • 2014
  • This paper investigates the standard features of Carrier aggregation (CA), the related UE RF requirements in 3GPP release 12 and estimated CA evolution in future. The main CA feature of 3GPP release 12 in WG4 perspectives includes 2Uplink(UL) CA, 3Downlink(DL) CA and TDD-FDD CA. To support these features in UE, UE-to-UE coexistence problem and RF requirements generated by unwanted emissions such as inter-modulation and harmonics are analyzed. Also, future CA technology such as LTE in unlicensed bands is described.

An Interleaved Converter for 12-pulse Rectifier Harmonic Suppression

  • Li, Yuan;Yang, Wei;Cang, Sheng;Yang, Shiyan
    • Journal of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.1349-1362
    • /
    • 2017
  • In order to further improve the harmonic suppression capability of conventional 12-pulse rectifiers, this paper proposes a low harmonic 12-pulse rectifier using an Active Inter-Phase Reactor (AIPR). Through a detailed analysis of the relationship between the input current, output current and circulating current of the DC side, the mechanism where the AC grid side current harmonics can be suppressed by the DC side circulating current is revealed. On this basis, an interleaved APFC controlled by a DSP is designed and used as an AIPR along with an interphase reactor. A simulation is carried out with MATLAB/Simulink and an experiment is performed on a 9-kVA prototype. The obtained results verify the feasibility and validity of the proposed approach. Compared with a traditional 12-pulse rectifier, the THD can be reduced to 1/5 of the original value, and the capacity of the AIPR is only 2% of the load power. Thus, it is suitable for high-power applications.

A Fundamental Study of VIV Fatigue Analysis Procedure for Dynamic Power Cables Subjected to Severely Sheared Currents (강한 전단 해류 환경에서 동적 전력케이블의 VIV 피로해석 절차에 관한 기초 연구)

  • Chunsik Shim;Min Suk Kim;Chulmin Kim;Yuho Rho;Jeabok Lee;Kwangsu Chea;Kangho Kim;Daseul Jeong
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.60 no.5
    • /
    • pp.375-387
    • /
    • 2023
  • The subsea power cables are increasingly important for harvesting renewable energies as we develop offshore wind farms located at a long distance from shore. Particularly, the continuous flexural motion of inter-array dynamic power cable of floating offshore wind turbine causes tremendous fatigue damages on the cable. As the subsea power cable consists of the helical structures with various components unlike a mooring line and a steel pipe riser, the fatigue analysis of the cables should be performed using special procedures that consider stick/slip phenomenon. This phenomenon occurs between inner helically wound components when they are tensioned or compressed by environmental loads and the floater motions. In particular, Vortex-induced vibration (VIV) can be generated by currents and have significant impacts on the fatigue life of the cable. In this study, the procedure for VIV fatigue analysis of the dynamic power cable has been established. Additionally, the respective roles of programs employed and required inputs and outputs are explained in detail. Demonstrations of case studies are provided under severely sheared currents to investigate the influences on amplitude variations of dynamic power cables caused by the excitation of high mode numbers. Finally, sensitivity studies have been performed to compare dynamic cable design parameters, specifically, structural damping ratio, higher order harmonics, and lift coefficients tables. In the future, one of the fundamental assumptions to assess the VIV response will be examined in detail, namely a narrow-banded Gaussian process derived from the VIV amplitudes. Although this approach is consistent with current industry standards, the level of consistency and the potential errors between the Gaussian process and the fatigue damage generated from deterministic time-domain results are to be confirmed to verify VIV fatigue analysis procedure for slender marine structures.

A Fault Detecting Scheme for Short-Circuited Turn in a Permanent Magnet Synchronous Motor through a Current Harmonic Monitoring (전류 고조파 관찰을 통한 영구자석 동기전동기의 권선 단락 고장 진단 기법)

  • Kim, Kyeong-Hwa;Gu, Bon-Gwan;Jung, In-Soung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.167-178
    • /
    • 2010
  • To diagnose a stator winding fault caused by a short-circuited turn in a permanent magnet synchronous motor (PMSM), an on-line based fault detecting scheme during motor operation is presented. The proposed scheme is based on monitoring the second-order harmonic components in q-axis current obtained through the harmonic analysis and a winding fault is detected by comparing these components with those in normal conditions. The linear interpolation method is employed to determine harmonic data in arbitrary normal operating conditions. To verify the effectiveness of the proposed fault detecting scheme, a test motor to allow inter-turn short in the stator winding has been built. The entire control system including harmonic analysis algorithm and fault detecting algorithm is implemented using DSP TMS320F28335. The proposed scheme does not require any additional hardware and can effectively detect a fault during motor operation so long as the steady-state condition is satisfied.