• Title/Summary/Keyword: Inter-calibration

Search Result 212, Processing Time 0.026 seconds

Development and validation of an LC-MS/MS method for the simultaneous analysis of 26 anti-diabetic drugs in adulterated dietary supplements and its application to a forensic sample

  • Kim, Nam Sook;Yoo, Geum Joo;Kim, Kyu Yeon;Lee, Ji Hyun;Park, Sung-Kwan;Baek, Sun Young;Kang, Hoil
    • Analytical Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.35-47
    • /
    • 2019
  • In this study, high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was employed to detect 26 antidiabetic compounds in adulterated dietary supplements using a simple, selective method. The work presented herein may help prevent incidents related to food adulteration and restrict the illegal food market. The best separation was obtained on a Shiseido Capcell Pak(R) C18 MG-II ($2.0mm{\times}100mm$, $3{\mu}m$), which improved the peak shape and MS detection sensitivity of the target compounds. A gradient elution system composed of 0.1 % (v/v) formic acid in distilled water and methanol at a flow rate of 0.3 mL/min for 18 min was utilized. A triple quadrupole mass spectrometer with an electrospray ionization source operated in the positive or negative mode was employed as the detector. The developed method was validated as follows: specificity was confirmed in the multiple reaction monitoring mode using the precursor and product ion pairs. For solid samples, LOD ranged from 0.16 to 20.00 ng/mL and LOQ ranged from 0.50 to 60.00 ng/mL, and for liquid samples, LOD ranged from 0.16 to 20.00 ng/mL and LOQ ranged from 0.50 to 60.00 ng/mL. Satisfactory linearity was obtained from calibration curves, with $R^2$ > 0.99. Both intra and inter-day precision were less than 13.19 %. Accuracies ranged from 80.69 to 118.81 % (intra/inter-day), with a stability of less than 14.88 %. Mean recovery was found to be 80.6-119.0 % and less than 13.4 % RSD. Using the validated method, glibenclamide and pioglitazone were simultaneously determined in one capsule at concentrations of 1.52 and 0.53 mg (per capsule), respectively.

Modification and Validation of an Analytical Method for Dieckol in Ecklonia Stolonifera Extract (곰피추출물의 지표성분 Dieckol의 분석법 개선 및 검증)

  • Han, Xionggao;Choi, Sun-Il;Men, Xiao;Lee, Se-jeong;Oh, Geon;Jin, Heegu;Oh, Hyun-Ji;Kim, Eunjin;Kim, Jongwook;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.143-148
    • /
    • 2022
  • This study was to investigate an analytical method for determining dieckol content in Ecklonia stolonifera extract. According to the guidelines of International Conference on Harmonization. Method validation was performed by measuring the specificity, linearity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of dieckol using high-performance liquid chromatography-photodiode array. The results showed that the correlation coefficient of calibration curve (R2) for dieckol was 0.9997. The LOD and LOQ for dieckol were 0.18 and 0.56 ㎍/mL, respectively. The intra- and inter-day precision values of dieckol were approximately 1.58-4.39% and 1.37-4.64%, respectively. Moreover, intra- and inter-day accuracies of dieckol were approximately 96.91-102.33% and 98.41-105.71%, respectively. Thus, we successfully validated the analytical method for estimating dieckol content in E. stolonifera extract.

HPLC Analysis of Piroxicam in the Rabbit Plasma and its Bioavailability after the Transdermal Administration of Patches (토끼 혈장 중 피록시캄의 HPLC 분석 및 패취제 투여 후 경피흡수)

  • Shin, Dae-Hwan;Park, Seong-Hyeok;Lee, Gyeong-Bok;Lee, Chong-Kil;Chung, Youn-Bok
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.3
    • /
    • pp.177-183
    • /
    • 2009
  • A rapid and sensitive reversed-phase high performance liquid chromatography (HPLC) method was developed for the determination of piroxicam in the rabbit plasma. After a treatment of plasma sample by liquid-liquid extraction, the drug was analyzed on an HPLC system with ultraviolet detection at 330 nm. HPLC was carried out using reversed-phase isocratic elution with a C18 column, a mobile phase of a mixture of acetonitril, doubly deionized water and acetic acid 43.74:56.00:0.26 v/v%) at a flow rate of 1.1 mL/min. The chromatograms showed good resolution and sensitivity and no interference of plasma. The calibration curve for the drug in plasma sample was linear over the concentration range of 0.01-2.0 ${\mu}$g/mL. The intra- and inter-day assay accuracies of this method ranged from 86.82% to 108.33% of normal values and the precision did not exceed 13% of relative standard deviation. The plasma concentration of piroxicam decreased to below the quantifiable limit at 12 hr after the i.v. bolus administration to rabbits following dose of 0.375 mg/kg yielding a apparen t plasma half life of 1.38 hr. The transdermal route prolongs plasma levels of piroxicam. The bioavailability, calculated from the dose-adjusted ratio of the $AUC_{transdermal}$ to the $AUC_{i.v.}$, was 7.44%. The plasma concentration of piroxicam was detected by 48 hr after the transdermal administration of patch at a dose of 32 mg/kg. This method was suitable for cutaneous absorption studies of piroxicam in the rabbit after transdermal administration of different types of dosages of the drug.

Simultaneous Determination of Triterpenoid Saponins from Pulsatilla koreana using High Performance Liquid Chromatography Coupled with a Charged Aerosol Detector (HPLC-CAD)

  • Yeom, Hye-Sun;Suh, Joon-Hyuk;Youm, Jeong-Rok;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.5
    • /
    • pp.1159-1164
    • /
    • 2010
  • Several triterpenoid saponins from root of Pulsatilla koreana Nakai (Ranunculaceae) were studied and their biological activities were reported. It is difficult to analyze triterpenoid saponins using HPLC-UV due to the lack of chromophores. So, evaporative light scattering detection (ELSD) is used as a valuable alternative to UV detection. More recently, a charged aerosol detection (CAD) has been developed to improve the sensitivity and reproducibility of ELSD. In this study, we developed and validated a novel method of high performance liquid chromatography coupled with a charged aerosol detector for the simultaneous determination of four triterpenoid saponins: pulsatilloside E, pulsatilla saponin H, anemoside B4 and cussosaponin C. Analytes were separated by the Supelco Ascentis$^{(R)}$ Express C18 column (4.6 mm ${\times}$ 150 mm, 2.7 ${\mu}m$) with gradient elution of methanol and water at a flow rate of 0.8 mL/min at $30^{\circ}C$. We examined various factors that could affect the sensitivity of the detectors, including various concentrations of additives, the pH of the mobile phase, and the CAD range. Linear calibration curves were obtained within the concentration ranges of 2 - 200 ${\mu}g$/mL for pulsatilloside E, anemoside $B_4$ and cussosaponin C, and 5 - 500 ${\mu}g$/mL for pulsatilla saponin H with correlation coefficient ($R^2$) greater than 0.995. The limit of detection (LOD) and quantification (LOQ) were 0.04 - 0.2 and 2 - 5 ${\mu}g$/mL, respectively. The validity of the developed HPLC-CAD method was confirmed by satisfactory values of linearity, intra- and inter-day accuracy and precision. This method could be successfully applied to quality evaluation, quality control and monitoring of Pulsatilla koreana.

Development of Fingerprints for Quality Control of Acorus species by Gas Chromatography/Mass Spectrometry

  • Yu, Se-Mi;Kim, Eun-Kyung;Lee, Je-Hyun;Lee, Kang-Ro;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.5
    • /
    • pp.1547-1553
    • /
    • 2011
  • An effective analytical method of gas chromatography/mass spectrometry (GC/MS) was developed for the rapid determination of essential oils in the crude extract of Acorus species (Acorus gramineus, Acorus tatarinowii, and Acorus calamus). Major phenypropanoids (${\beta}$,${\alpha}$-asarone isomers, euasarone, and methyleugenol) and ${\beta}$-caryophyllene in Acorus species were used as marker compounds and determined for the quality control of herbal medicines. To extract marker compounds, various extraction techniques such as solvent immersion, mechanical shaking, and sonication were compared, and the greatest efficiency was observed with sonication extraction using petroleum ether. The dynamic range of the GC/MS method depended on the specific analyte; acceptable quantification was obtained between 10 and 2000 ${\mu}g/mL$ for ${\beta}$-asarone, 10 and 500 ${\mu}g/mL$ for ${\alpha}$-asarone, 10 and 200 ${\mu}g/mL$ for methyleugenol, and between 5 and 100 ${\mu}g/mL$ for ${\beta}$-caryophyllene. The method was deemed satisfactory by inter- and intra-day validation and exhibited both high accuracy and precision, with a relative standard deviation < 10%. Overall limits of detection were approximately 0.34-0.83 ${\mu}g/mL$, with a standard deviation (${\sigma}$)-to-calibration slope (s) ratio (${\sigma}$/s) of 3. The limit of quantitation in our experiments was approximately 1.13-3.20 ${\mu}g/mL$ at a ${\sigma}$/s of 10. On the basement of method validation, 20 samples of Acorus species collected from markets in Korea were monitored for the quality control. In addition, principal component analysis (PCA) and hierarchical cluster analysis (HCA) were performed on the analytical data of 20 different Acorus species samples in order to classify samples that were collected from different regions.

Liquid Chromatography-Tandem Mass Spectrometric Determination of Geniposide in Rat Plasma and its Pharmacokinetic Application

  • Jin, Ming Ji;Kim, In Sook;Kim, Dong-Hyun;Yoo, Hye Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2760-2764
    • /
    • 2013
  • Geniposide is a biologically active ingredient of gardenia fruit. A liquid chromatography-tandem mass spectrometric method was developed and validated for the determination of geniposide in rat plasma. The plasma samples were pretreated by solid-phase extraction and introduced into a BDS Hypersil $C_{18}$ column ($50{\times}2.1mm$, $5{\mu}m$) for chromatographic separation. The mobile phase consisted of 0.1% formic acid and 0.1% formic acid in acetonitrile, and gradient elution was performed at a flow rate of 0.25 mL/min. For mass spectrometric detection, multiple reaction monitoring was performed via an electrospray ionization source in positive mode. The calibration curve for geniposide was linear ($r^2=0.997$) in the concentration range of $0.005-1{\mu}g/mL$. The intra- and inter-day accuracies and precisions fulfilled the required criteria (${\pm}15%$). The developed method was subsequently used for pharmacokinetic analysis of geniposide after oral administration to rats at a dose of 50 mg/kg. The mean maximum plasma concentration of geniposide was $0.68{\pm}0.29{\mu}g/mL$ at $0.44{\pm}0.13h$, and the mean area under the plasma concentration versus time curve was $1.46{\mu}g{\cdot}h/mL$.

An 8-Gb/s/channel Asymmetric 4-PAM Transceiver with an Adaptive Pre-emphasis for Memory Interface (메모리 인터페이스를 위한 적응형 프리엠퍼시스를 가지는 8-Gb/s/채널 비균형 4-레벨 펄스진폭변조 입출력회로)

  • Jang, Young-Chan;Jun, Young-Hyun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.8
    • /
    • pp.71-78
    • /
    • 2009
  • An 8${\times}$8-Gb/s/channel 4-PAM transceiver was designed for high speed memory applications by using 70nm DRAM process with 1.35V supply. An asymmetric 4-PAM signaling scheme is proposed to increase the voltage and time margin of upper and lower eyes in 3-class eye opening. A mathematical basis shows that this scheme statistically reduces 33% of reference noise effect in a receiver. Also, an adaptive pre-emphasis scheme, which utilizes a lone-bit pulse with integrator at the receiver, is introduced to reduce ISI for a simple DRAM channel. In this scheme, an integrating clock timing calibration by using a pre-determined pattern is proposed for the optimum ISI measurement.

Simultaneous quantitative analysis of salivary cortisol and cortisone in Korean adults using LC-MS/MS

  • Lee, Sang-Hoo;Kwon, Soon-Ho;Shin, Hye-Jin;Lim, Hwan-Sub;Singh, Ravinder J.;Lee, Kyoung-Ryul;Kim, Young-Jin
    • BMB Reports
    • /
    • v.43 no.7
    • /
    • pp.506-511
    • /
    • 2010
  • The levels of salivary cortisol and cortisone in Korean adults were measured for the first time using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The salivary cortisol and cortisone were separated within 10 min. The regression coefficients (r) of the calibration curves were greater than 0.999 for the two steroids. The limits of quantitation (LOQ) were 0.2 ng/ml for cortisol and 1 ng/ml for cortisone. The intra-day precisions of the assay were <3.9% and 8.6% for cortisol and cortisone respectively, and the inter-day precisions were <1.9% and 4.3% for cortisol and cortisone, respectively. The salivary cortisone concentrations were approximately 4-9 times higher than those of salivary cortisol during the daytime. Diurnal rhythms, during which the cortisol and cortisone concentrations were higher in the morning than in the afternoon, were also observed. The present assay may be useful for the diagnosis of several adrenal dysfunctions in clinical biochemistry.

Simultaneous Determination of Six Bioactive Components in Guibi-tang by HPLC-DAD (HPLC-DAD를 이용한 귀비탕 중 6종 생리활성 물질의 동시분석법 확립)

  • Yang, Hye-Jin;Weon, Jin-Bae;Ma, Jin-Yeul;Ma, Choong-Je
    • Korean Journal of Pharmacognosy
    • /
    • v.41 no.4
    • /
    • pp.313-318
    • /
    • 2010
  • Guibi-tang, a traditional herbal medicine, is used for anti-oxidant, anti-osteoporosis, hemostasis and gastroprotection. To develop an analysis method of simultaneous determination of six compounds, swertisin, decursinol, glycyrrhizin, 6-gingerol, costunolide and decursin in Guibi-tang, a high performance liquid chromatography was used with diode array detector. Six bioactive components were separated on a SHISEIDO $C_{18}$ column ($5\;{\mu}m$, 4.6 mm I.D.${\times}$250 mm) with column temperature $30^{\circ}C$. The gradient elution was composed of water with 0.1% trifluoroacetic acid (TFA) and acetonitrile. UV wavelength was set at 230 nm, 254 nm and 330 nm, respectively. Calibration curve showed good linear regression ($R^2$ > 0.9999). The limits of detection (LOD) and the limits of quantification (LOQ) ranged in 0.03 - 0.23 ${\mu}g/ml$ and 0.08 - $0.70\;{\mu}g/ml$, respectively. The RSD values of intra- and inter-day test were in the range of 0.03 ~ 0.96% and 0.01 ~ 1.46%, respectively. The evaluated results of accuracy test were varied from 92.28% ~ 105.14% with RSD < 1.60%. In conclusion, this developed simultaneous determination method was accuracy and sensitive to the quality evaluation of Guibi-tang.

Development of an UPLC-DAD Method for Simultaneous Analysis of Eight Marker Compounds of Bulhwangeumjeonggi-san (UPLC-DAD를 이용한 불환금정기산의 다성분 동시분석법 개발)

  • Lee, Kyung-hee;Lamichhane, Ramakanta;Kumar, Sharma Dipak;Raj, Pandeya Prakash;Kim, Se-Gun;Jung, Hyun-Ju
    • Korean Journal of Pharmacognosy
    • /
    • v.47 no.4
    • /
    • pp.366-373
    • /
    • 2016
  • Bulhwangeumjeonggisan (BHGJGS) is a traditional herbal formulation generally used in the treatment of cold and gastritis. BHGJGS consists of eight herbal plants; Atractylodis Rhizoma, Magnoliae Cortex, Citri Pericarpium, Glycyrrhizae Radix, Agastachis Herba, Pinelliae Rhizoma, Zingiberis Rhizoma and Zizyphi Fructus. Complete standardization of this formulation has not been done yet. So, a simple and accurate method was developed and validated using Ultra Performance Liquid Chromatography (UPLC) with Diode Array Detector (DAD) for the standardization of BHGJGS. UPLC conditions were optimized using a c18 RP-Amide column with mobile phase; 0.1% phosphate buffer and acetonitrile, detection wavelength; 210 and 325 nm. The linearities of calibration curves were acceptable ($R^2$>0.9994), and the limit of detection and quantification were within the ranges of 0.011-0.091 and $0.034-0.277{\mu}g/ml$ respectively. The relative standard deviation (RSD) of intra- and inter-day precisions were under 3.61%. The RSD of repeatability was under 0.68 %. The results of recovery test were 94.4-107.9%, and the RSD were under 4.6%. The developed method was used to find the contents of standard constituents in BHGJGS mix extract powder, and two commercial formulation (A and B). The data show that the developed method was specific, sensitive, accurate, and precise for analysis of BHGJGS components.