Quality Assurance of Multileaf Collimator Using Electronic Portal Imaging (전자포탈영상을 이용한 다엽시준기의 정도관리)

  • ;Jason W Sohn
    • Progress in Medical Physics
    • /
    • v.14 no.3
    • /
    • pp.151-160
    • /
    • 2003
  • The application of more complex radiotherapy techniques using multileaf collimation (MLC), such as 3D conformal radiation therapy and intensity-modulated radiation therapy (IMRT), has increased the significance of verifying leaf position and motion. Due to thier reliability and empirical robustness, quality assurance (QA) of MLC. However easy use and the ability to provide digital data of electronic portal imaging devices (EPIDs) have attracted attention to portal films as an alternatives to films for routine qualify assurance, despite concerns about their clinical feasibility, efficacy, and the cost to benefit ratio. In this study, we developed method for daily QA of MLC using electronic portal images (EPIs). EPID availability for routine QA was verified by comparing of the portal films, which were simultaneously obtained when radiation was delivered and known prescription input to MLC controller. Specially designed two-test patterns of dynamic MLC were applied for image acquisition. Quantitative off-line analysis using an edge detection algorithm enhanced the verification procedure as well as on-line qualitative visual assessment. In conclusion, the availability of EPI was enough for daily QA of MLC leaf position with the accuracy of portal films.

  • PDF

Comparison of Treatment Plans with Multileaf Collimators of Different Leaf Widths (Leaf width가 다른 다엽 콜리메터에 의한 치료계획 비교)

  • Kim, Joo-Young;Lee, Doo-Hyun;Lee, Seok-Ho;Cho, Kwan-Ho;Park, Sung-Yong
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2004.11a
    • /
    • pp.126-129
    • /
    • 2004
  • We compared intensity-modulated radiotherapy (IMRT) treatment plans with commercially available multileaf collimators (MLCs) of different leaf width for intracranial lesions. Twelve cases previously treated with micro-MLCs(mMLCs) were replanned using the Varian 120 and 80 MLCs. These collimators have minimum leaf width of 3mm, 5 mm and 10 mm at isocenter, respectively. These three plans were compared with respect to the uniformity and the conformity indices, doses to normal tissue. For the uniformity index of planning target volume (PTV),there was no statistically significant difference between mMLCs with 120 MLCs (p = 0.06). However, there was a little difference between mMLCs with 80 MLCs (p = 0.001). Maximum target dose to the PTV showedno dependency with respect to the leaf width. On the contrary, there were statistically significant differences in the conformity indices between mMLCs and 120 MLCs (p = 0.003) and between mMLCs and 80 MLCs (p = 0.003).The volumetric increments for MLCs with leaf widths of 5 mm and 10 mm were 6.3% and 23.2% for the normal tissue Irradiated to = 50% dose, and 8.7% and 32.7% for the normal tissue Irradiated to = 70% dose, respectively, compared to the volume for MLCs with leaf width of 3 mm. This shows that for the sparing of normal tissue, MLCs with leaf width of 3 mm are more effective, compared to MLCs with leaf widths of 5 mm and 10 mm.

  • PDF

Methodologic Aspect of LINAC-based Stereotactic Radiosurgery (선형가속기 기반 뇌정위 방사선 수술기법)

  • Choi, Tae Jin
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.127-137
    • /
    • 2012
  • A conversing beam is firstly designed for radiosurgery by a neurosugern Lars Leksell in 1949 with orthogonal x-rays tube moving through horizontal moving arc to focusing the beam at target center. After 2 decades he composits 201 source of the Co-60 for gamma knife which beams focused at locus. Sveral linac-based stereotactic radiosurgery using the circular collimated beam which size range for 0.4~4.0 cm in a diameter by non-coplanar multiarc have been developed over the decades. The irregular lesions can be treated by superimposing with several spherical shots of radiation over the tumour volume. Linac based techniques include the use of between 4 and 11 non-co-planar arcs and a dynamic rotation technique and use photon beam energies in the range of 6~10 MV. Reviews of the characteristics of several treatment techniques can be found in the literature (Podgorsak 1989, Schell 1991). More in recent, static conformal beams defined by custom shaped collimators or a mini- or micro-multileaf collimator (mMLC) have been used in SRS. Finally, in the last few years, intensity-modulated mMLC SRS has also been introduced. Today, many commercial and in-house SRS programs have also introduced non-invasive immobilization systems include the cyberknife and tomotherapy and proton beam. This document will be compared the characteristics of dose distribution of radiosurgery as introduced gamma knife, BrainLab include photon knife in-house SRS program and cyberknife in currently wide used for a cranial SRS.

Determination of Phantom Scatter Factors for Small Photon Fields (소조사면 광자선의 팬톰산란인수 결정)

  • Oh, Young-Kee;Choi, Tae-Jin;Kim, Jin-Hee;Kim, Ok-Bae
    • Progress in Medical Physics
    • /
    • v.20 no.2
    • /
    • pp.106-111
    • /
    • 2009
  • Total scatter factor ($S_{cp}$), head scatter factor ($S_c$) and phantom scatter factor ($S_p$) are very important for accurate radiation therapy at stereotactic radiosurgery (SRS) with irregular field shape using micro-MLC and intensity modulated radiation therapy (IMRT) including many small field sizes. In this study we measured and compared $S_{cp}$ with reference ion chamber, pinpoint chamber and diode detector and adapted the resuls form diode detector. Head scatter factors for small field sizes were also measured with diode detector covered 1.5 cm-thick solid water build-up cap. Some errors like as electron contamination of 1~3% were included in the values of Sc but trend of total results of $S_c$ was coincided with basic theory. Phantom scatter factors for small field sizes were calculated form $S_{cp}$ and $S_c$. The results of $S_p$ were compared and were well-agreed with those of other authors.

  • PDF

The effect of endurance exercise and MitoQ intake on pathological characteristics in MPTP-induced animal model of Parkinson's disease (지구성 운동과 MitoQ 섭취가 MPTP로 유도된 파킨슨 질환 생쥐의 병리학적 특징에 미치는 영향)

  • Kim, Dong-Cheol;Um, Hyun Seob;Oh, Eun-Tak;Cho, Joon-Yong;Jang, Yongchul
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.4
    • /
    • pp.744-754
    • /
    • 2020
  • We investigated the whether endurance exercise and MitoQ intake mediated neuroprotection are associated with mitochondrial function in 1-methyl-4-phenyl-1,2,3,6 tetrahydropyridine(MPTP) -induced mice model of Parkinson's disease. C57BL/6 male mice were randomly assigned to five groups: Normal Conrol(NC, n=10), MPTP Control(MC, n=10), MPTP +MitoQ(MQ, n=10), MPTP + Exercise(ME, n=10) and MPTP + MitoQ + Exercise(MQE, n=10). Exercise intervention groups performed the treadmill exercise for 5days/week for 5 weeks with gradual increase of intensity. MitoQ intake groups consumed the MitoQ at a concentration of 250μmol by dissolving with water during experiment period. Our data demonstrated that ME and MQE group restored MPTP-induced motor dysfunction. In addition, treatment groups(MQ, ME and MQE) increased tyrosine hydroxylase levels, and suppressed the accumulation of α-synuclein levels. Futhermore, treatment groups modulated the mitochondrial function such as upregulated mitochondrial biogenesis, increased antioxidant enzyme, enhanced a anti-apoptotic protein(e.g., BCL2), and reduced a pro-apoptotic protein(e.g., BAX). Taken together, these results suggested that endurance exercise and MitoQ intake-mediated increase in mitochondrial function contributes to improvement of aggravated dopaminergic neuronal, resulting in attenuation of motor function of Parkinson's disease.

A Study on the Evaluation of 3D Dose Distribution using Normoxic Polymer Gel (정상산소 중합체 겔 선량계를 이용한 3차원 방사선량 평가에 관한 연구)

  • Chung, Se-Young;Kim, Young-Bum;Kwon, Young-Ho;Lee, Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.7-17
    • /
    • 2007
  • Purpose: As increasing complexity of modern radiotherapy technique, more developing dosimetry is required. Polymer gel dosimeters offer a wide range of potential applications with high resolution and assured quality in the thee-dimensional verification of complex dose distribution such as intensity-modulated radiotherapy (IMRT). The purpose of this study is to find the most sensitive and suitable gel as a dosimeter by varying its composition ratio and its condition such as temperature during manufacturing. Materials and Methods: Each polymer gel with various ratio of composition was irradiated with the same amount of photon beam accordingly. Various polymer gels were analyzed and compared using a dedicated software written in visual C++ which converts TE images to R2 map images. Their sensitivities to the photon beam depending on their composition ratio were investigated. Results: There is no dependence on beam energy nor dose rate, and calibration curve is linear. Conclusion: The polymer gel dosimeter developed by using anti-oxidant in this study proved to be suitable for dosimetry.

  • PDF

Evaluation of the Small Field of for the Detector Type Medical Linear Accelerator (의료용 선형가속기의 소조사면에 대한 검출기 종류에 따른 평가)

  • Lee, Dong-Woon;Jung, Kang-Kyo;Shin, Gwi-Soon;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.177-184
    • /
    • 2016
  • Recently linear accelerator of radiation therapy intensity modulated radiation therapy, stereotactic radiation therapy are widely used. Such radiation treatment techniques are generally difficult to exclude the small field by using the inverse treatment plan. It is necessary to dose an accurate measurement of characteristics of the small field. Thus, using different detectors to measure the volume of the effective percentage depth dose, beam profile, and the output factor of the small field was to evaluate the dose characteristics of each detector. Experimental results for the X-ray beam 6 MV energy beam quality($PDD_{20}/PDD_{10}$) is $10{\times}10cm^2$ Diode detector is as high as 2.4% compared to Pinpoint detector. All field size to lesser effective volume of Diode detector shows that it is far better than other detectors by more than 50% of small penumbra, therefore spatial resolution far excellent. In field size $2{\times}2cm^2$ Semiflex detector was measured about 2% less than the other detector. Field size $1{\times}1cm^2$ is that there is no judgment about the validity show the difference between 20%. Field size $1{\times}1cm^2$ from the measured values of the Diode detector and Pinpoint detector showed a 13% difference. Less than field size $3{\times}3cm^2$ the feed to the difference between the output factor of the effective volume of the detector to be used for the effective volume available to the detector.

Postoperative radiotherapy for ependymoma

  • Jung, Jinhong;Choi, Wonsik;Ahn, Seung Do;Park, Jin Hong;Kim, Su Ssan;Kim, Young Seok;Yoon, Sang Min;Song, Si Yeol;Lee, Sang-Wook;Kim, Jong Hoon;Choi, Eun Kyung
    • Radiation Oncology Journal
    • /
    • v.30 no.4
    • /
    • pp.158-164
    • /
    • 2012
  • Purpose: To evaluated the patterns of failure, survival rate, treatment-related toxicity and prognostic factors in postoperative radiotherapy of patients with ependymoma. Materials and Methods: Thirty patients who underwent surgery and postoperative radiotherapy for ependymoma between the period of June 1994 and June 2008 were reviewed retrospectively. The age of patients ranged from 21 months to 66 years (median, 19 years). Seventeen patients had grade II ependymoma, and 13 had grade III anaplastic ependymoma according to the World Health Organization grading system. The postoperative irradiation was performed with 4 or 6 MV photon beam with median dose of 52.8 Gy (range, 45 to 63 Gy), and radiation field including 2 cm beyond the preoperative tumor volume. Median follow-up period was 51 months (range, 12 to 172 months). Results: Fourteen out of 30 (46.7%) patients experienced recurrence, and 12 of those died. Among those 14 patients who experienced recurrence, 11 were in-field and 3 were out-of-field recurrence. The 5-year overall survival (OS) and progression-free survival (PFS) rates were 66.7% and 56.1%, respectively. On univariate analysis, tumor grade was a statistically significant prognostic factor for OS and PFS. There were two complications after surgery and postoperative radiotherapy, including short stature and facial palsy on the left side. Conclusion: We observed good survival rates, and histologic grade was a prognostic factor affecting the OS and PFS. Almost all recurrence occurred in primary tumor site, thus we suggest further evaluation on intensity-modulated radiotherapy or stereotatic radiosurgery for high-risk patients such as who have anaplastic ependymoma.

Dosimetric evaluation of Tomotherapy and four-box field conformal radiotherapy in locally advanced rectal cancer

  • Yu, Mina;Jang, Hong Seok;Jeon, Dong Min;Cheon, Geum Seong;Lee, Hyo Chun;Chung, Mi Joo;Kim, Sung Hwan;Lee, Jong Hoon
    • Radiation Oncology Journal
    • /
    • v.31 no.4
    • /
    • pp.252-259
    • /
    • 2013
  • Purpose: To report the results of dosimetric comparison between intensity-modulated radiotherapy (IMRT) using Tomotherapy and four-box field conformal radiotherapy (CRT) for pelvic irradiation of locally advanced rectal cancer. Materials and Methods: Twelve patients with locally advanced rectal cancer who received a short course preoperative chemoradiotherapy (25 Gy in 5 fractions) on the pelvis using Tomotherapy, between July 2010 and December 2010, were selected. Using their simulation computed tomography scans, Tomotherapy and four-box field CRT plans with the same dose schedule were evaluated, and dosimetric parameters of the two plans were compared. For the comparison of target coverage, we analyzed the mean dose, $V_{nGy}$, $D_{min}$, $D_{max}$, radical dose homogeneity index (rDHI), and radiation conformity index (RCI). For the comparison of organs at risk (OAR), we analyzed the mean dose. Results: Tomotherapy showed a significantly higher mean target dose than four-box field CRT (p = 0.001). But, $V_{26.25Gy}$ and $V_{27.5Gy}$ were not significantly different between the two modalities. Tomotherapy showed higher $D_{max}$ and lower $D_{min}$. The Tomotherapy plan had a lower rDHI than four-box field CRT (p = 0.000). Tomotherapy showed better RCI than four-box field CRT (p = 0.007). For OAR, the mean irradiated dose was significantly lower in Tomotherapy than four-box field CRT. Conclusion: In locally advanced rectal cancer, Tomotherapy delivers a higher conformal radiation dose to the target and reduces the irradiated dose to OAR than four-box field CRT.

Radiotherapy for initial clinically positive internal mammary nodes in breast cancer

  • Kim, Jina;Chang, Jee Suk;Choi, Seo Hee;Kim, Yong Bae;Keum, Ki Chang;Suh, Chang-Ok;Yang, Gowoon;Cho, Yeona;Kim, Jun Won;Lee, Ik Jae
    • Radiation Oncology Journal
    • /
    • v.37 no.2
    • /
    • pp.91-100
    • /
    • 2019
  • Purpose: Internal mammary lymph node (IMN) involvement is associated with poor prognosis in breast cancer. This study investigated the treatment outcomes of initial clinically IMN-positive breast cancer patients who received adjuvant radiotherapy (RT), including IMN irradiation, following primary breast surgery. Materials and Methods: We retrospectively reviewed data of 95 breast cancer patients with clinically detected IMNs at diagnosis treated with surgery and RT between June 2009 and December 2015. Patients received adjuvant RT to the whole breast/chest wall and regional lymph node (axillary, internal mammary, and supraclavicular) areas. Twelve patients received an additional boost to the IMN area. Results: The median follow-up was 43.2 months (range, 4.5 to 100.5 months). Among 77 patients who received neoadjuvant chemotherapy, 52 (67.5%) showed IMN normalization and 19 (24.6%) showed a partial response to IMN. There were 3 and 24 cases of IMN failure and any recurrence, respectively. The 5-year IMN failure-free survival, disease-free survival (DFS), and overall survival (OS) were 96%, 70%, and 84%, respectively. IMN failure-free survival was significantly affected by resection margin status (97.7% if negative, 87.5% for close or positive margins; p = 0.009). All three patients with IMN failure had initial IMN size ≥1 cm and did not receive IMN boost irradiation. The median age of the three patients was 31 years, and all had hormone receptor-negative tumors. Conclusion: RT provides excellent IMN control without the support of IMN surgery. Intensity-modulated radiotherapy, including IMN boost for breast cancer patients, is a safe and effective technique for regional lymph node irradiation.