• Title/Summary/Keyword: Intensity of elements

Search Result 373, Processing Time 0.028 seconds

Interlaminar stresses and delamination of composite laminates under extension and bending

  • Nguyen, Tien Duong;Nguyen, Dang Hung
    • Structural Engineering and Mechanics
    • /
    • v.25 no.6
    • /
    • pp.733-751
    • /
    • 2007
  • The metis element method (Hung 1978) has been applied to analyse free edge interlaminar stresses and delamination in composite laminates, which are subjected to extension and bending. The paper recalls Lekhnitskii's solution for generalized plane strain state of composite laminate and Wang's singular solution for determination of stress singularity order and of eigen coefficients $C_m$ for delamination problem. Then the formulae of metis displacement finite element in two-dimensional problem are established. Computation of the stress intensity factors and the energy release rates are presented in details. The energy release rate, G, is computed by Irwin's virtual crack technique using metis elements. Finally, results of interlaminar stresses, the three stress intensity factors and the energy release rates for delamination crack in composite laminates under extension and bending are illustrated and compared with the literature to demonstrate the efficiency of the present method.

Measurement of Stride Length Using Optical Method (광학적 분석방법을 이용한 보폭측정)

  • Jung, Gu-In;Jun, Jae-Hoon;Lee, Kang-Hwi;Song, Min-Sun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.6
    • /
    • pp.1116-1122
    • /
    • 2008
  • Since conventional methods for measuring stride length(distance) are many weaknesses, optical methods have been developed to measure stride length(distance) of human pedestrians. IR(Infrared) elements and Power LED(Light Emitting Diode) with two types of lens were used to correlate detected light intensity with stride length(distance). The suggested methods in this study are simple, convenient, and cost effective. The results can be used to analyze walking patterns of normal and disabled men, and to monitor the recovering processes of the disabled patients.

Noise Contribution Analysis and Noise reduction of a Diesel Engine Fork-lift Truck (디젤 엔진 지게차의 소음원별 기여도 분석과 실내소음 저감)

  • Lee, J.K.;Cho, Y.H.;Kim, G.H.;Park, S.T.;Kim, N.I.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1473-1478
    • /
    • 2000
  • Severe fork-lift truck noise is annoying to an operator as well as one of the noise pollution elements. This paper presents the noise contribution analysis of a cabin type fork-lift truck to identify the major sources and its usage to reduce the interior noise level. The methodologies for this work are sound field analysis, sound intensity test, insertion loss test of duct system and etc. An effective method to suppress interior noise level of fork-lift truck and design guides are suggested.

  • PDF

Fracture analysis for nozzle cracks in nuclear reactor pressure vessel using FCPAS

  • Abdurrezzak Boz;Oguzhan Demir
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2292-2306
    • /
    • 2024
  • This study addresses cracks and fracture problems in engineering structures that may cause significant challenges and safety concerns, with a focus on pressure vessels in nuclear power plants. Comprehensive parametric three-dimensional mixed mode fracture analyses for inclined and deflected nozzle corner cracks with various crack shape aspect ratios and depth ratios in nuclear reactor pressure vessels are carried out. Stress intensity factor (SIF) solutions are obtained using FRAC3D, which is part of Fracture and Crack Propagation Analysis System (FCPAS), employing enriched finite elements along the crack front. Also, improved empirical equations are developed to allow the determination of mixed mode SIFs, KI, KII, and KIII, for any values of the parameters considered in the study. This study provides practical solutions to assess the remaining life and fail-safe conditions of nuclear reactors by providing accurate SIF determination.

A Study on the Tank Liquid-Level Monitoring Sensor Systems for Large Scaled Vessels (대형선박의 액체 탱크용 수위 모니터링 센서 시스템 연구)

  • Sohn, Kyung-Rak;Kim, Jin-Wook;Cho, Seok-Je;Shim, Joon-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.330-335
    • /
    • 2009
  • A fiber-optic liquid level sensor based on bending cantilever beam has been proposed. A fiber Bragg grating(FBG) embedded in the cantilever beam is used to sensing elements. The basic concept is elongation and constriction of the FBG corresponding to the liquid level variation. The best FBG position on the cantilever for obtaining the high sensitivity was 4 cm from the fixing point. When the liquid level moves up and down vertically, the Bragg wavelength is linearly shifted. But, the wavelength sensitivity of the FBG installed on the upper side of cantilever was four times better than that of the FBG equipped in the lateral side due to the difference of unit strain applied to the FBG. Intensity demodulation using the low-cost edge filter is used to interrogate the Bragg wavelength through converting the wavelength signals into the optical intensity ones. Experiment results show that the electrical output is exponentially proportional to the liquid level. But, it should be overcome for applying to the ships.

Effects of Yoga on Pain, Function, and Depression in Individuals with Nonspecific-Low Back Pain

  • Song, Seonghyeok;Choi, Youngam;Cho, Namjeong;Kim, Hyun-Joong
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.2
    • /
    • pp.165-171
    • /
    • 2022
  • Objective: Nonspecific low back pain (NSLBP) is experienced worldwide by many age groups. Yoga is recommended as an exercise to reduce back pain and stress because it is a breathing exercise, posture, and meditation as key elements. The aim of this study is to compare the effects of yoga and stabilization exercise on pain intensity, function, and depression. Design: An open-label, parallel arm, randomized controlled trial Methods: Twenty-four participants were allocated to the experimental and the control group in a ratio of 1:1. Yoga (experimental group) and stabilization exercise (control group) were received twice a week for 6 weeks Participants were assessed at baseline and post-intervention for pain intensity (numeric pain rating scale), function (Aberdeen low back pain scale, flexibility,and strength), and depression (Beck depression inventory). Results: When the experimental group (Yoga) and control group (stabilization exercise) were performed twice a week for 6 weeks, numeric pain rating scale, Aberdeen low back pain scale, and flexibility in post-intervention showed significant improvement in both groups (P<0.05), However, in all variables, the experimental group showed a positive benefit compared to the control group (P<0.05). Conclusions: The results of this study show that yoga has more positive benefits compared to stabilization exercise in pain intensity, function, and depression in individuals with NSLBP.

Integrity Evaluation for 3D Cracked Structures(I) (3차원 균열을 갖는 구조물에 대한 건전성 평가(I))

  • Lee, Joon-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.8
    • /
    • pp.3295-3300
    • /
    • 2012
  • Three Dimensional finite element method (FEM) was used to obtain the stress intensity factor for subsurface cracks and surface cracks existing in inhomogeneous materials. A geometry model, i.e. a solid containing one or several 3D cracks is defined. Several distributions of local node density are chosen, and then automatically superposed on one another over the geometry model. Nodes are generated by the bubble packing, and ten-noded quadratic tetrahedral solid elements are generated by the Delaunay triangulation techniques. To examine accuracy and efficiency of the present system, the stress intensity factor for a semi-elliptical surface crack in a plate subjected to uniform tension is calculated, and compared with Raju-Newman's solutions. Then the system is applied to analyze interaction effects of two dissimilar semi-elliptical cracks in a plate subjected to uniform tension.

Approximate and Three-Dimensional Modeling of Brightness Levels in Interior Spaces by Using Artificial Neural Networks

  • Sahin, Mustafa;Oguz, Yuksel;Buyuktumturk, Fuat
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1822-1829
    • /
    • 2015
  • In this study, artificial neural networks were used to determine the intensity of brightness in interior spaces. The illumination elements to illuminate indoor spaces were considered, not individually, but as a system. So, during the planned maintenance periods of an illumination system, after its design and installation, simple brightness level measurements must be taken. For a three-dimensional evaluation of the brightness level in indoor spaces in a speedy and accurate manner, the obtained brightness level measurement results and artificial neural network model were used. Upon estimation of the most suitable brightness level for indoor spaces by using the artificial neutral network model, the energy demands required by the illumination elements decreased. Consequently, in this study, with estimations of brightness levels, the extent to which the artificial neutral networks become successful was observed and more correct results have been obtained in terms of both economy and usage.

An Evaluation of the Quantitative Risk of Plastic Process Manufacturing Industries by Means of the 4M Method

  • Lee, Dong-Ho;Kim, Jong-In
    • International Journal of Safety
    • /
    • v.6 no.2
    • /
    • pp.8-12
    • /
    • 2007
  • This study includes a case study among plastic process manufacturing companies, based on which, the currently used 4M method is applied in terms of machine, media, man, and management, to conduct quantitative risk evaluation, and thus to contribute to reducing human and material loss as well as preventing accidents in industrial fields. The result of this study is analyzed based on the 4M-risk assessment to find out the hazardous risk elements, and the quantitative evaluation made it predictable the value of risk(frequency $\times$ intensity) in such classified levels as serious risk, critical risk, and intolerable risk. Further, Among the businesses with hazardous risk elements and high frequency of industrial disaster, risk analysis was conducted for each process, and as a result, 38 cases among 76, including those of serious risk, critical risk, and intolerable risk, were improved, and the risk was reduced. Besides, it is thought that with the engineering approach with 4M-Risk Assessment, the attempt to improve safety level contributes to prevention of accidents.

The Study of Designing the Parameters of DC Reactor for Inductive Superconducting Fault Current Limiter By Using Finite Element Method (유한요소법을 이용한 유도형 고온 초전도 한류기용 DC Reactor의 설계 파라미터 결정법에 관한 연구)

  • 김용구;강형구;김태중;윤용수;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.326-329
    • /
    • 2002
  • The dc reactor type superconducting fault current limiter is composed of a power converter, magnetic core reactors and a do reactor that is a superconducting coil. When a fault occurs, the dc reactor maintains the stability of system by limiting its fault current. In this study, we focus on the design of the dc reactor using FEM(Finite Element Method). In order to design it, various elements should be considered such as magnetic field intensity, Lorentz's force, its inductance and so forth. Firstly, we forecast the values of those elements from the simulation of FEM and then measured with a copper wire magnet. Finally, verify the reliability of this FEM method by comparing with two results.

  • PDF