• 제목/요약/키워드: Intensity method

검색결과 4,833건 처리시간 0.037초

맵핑 테이블을 이용한 전역 밝기 보상 (Global Intensity Compensation using Mapping Table)

  • 오상진;이지홍;고윤호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.15-17
    • /
    • 2006
  • This paper presents a new global intensity compensation method for extracting moving object in a visual surveillance system by compensating time variant intensity changes of background region. The method that compensates a little changes of intensity due to time variant illumination change and automatic gain control of camera is called global intensity compensation. The proposed method expresses global intensity change with a mapping table to describe complex form of intensity change while the previous method models this global intensity change with a simple function as a straight line. The proposed method builds the mapping table by calculating the cross histogram between two images and then by selecting an initial point for generating the mapping table by using Hough transform applied to the cross histogram image. Then starting from the initial point, the mapping table is generated according to the proposed algorithm based on the assumption that reflects the characteristic of global intensity change. Experimental results show that the proposed method makes the compensation error much smaller than the previous GIC method

  • PDF

복소음향인텐시티법을 이용한 HVAC의 소음원 검출 (Identification of Noise Source of the HVAC Using Complex Acoustic Intensity Method)

  • 양정직;이동주
    • 한국소음진동공학회논문집
    • /
    • 제20권11호
    • /
    • pp.1089-1096
    • /
    • 2010
  • The relation between the vibration induced from machinery and the radiated sound is complicated. Acoustic intensity method is widely used to obtain the accuracy of noise measurement and noise identification. In this study, as groundwork, the complex acoustic intensity method is performed to identify noise source and transmission path on different free space point source fields. As an industrial application, the complex acoustic intensity method is applied to HVAC to identify sound radiation characteristics in the near field. Experimental complex acoustic intensity method was applied to HVAC, it is possible to identify noise sources in complicated sound field characteristics which noise sources are related with each other, and certificate the validity of complex acoustic intensity. Especially, it can be seen that complex acoustic intensity method using both of active and reactive intensity is vital in devising a strategy for identification of noise. Also, the vector flow of acoustic intensity was investigated to identify sound intensity distributions and energy flow in the near field of HVAC.

수정진도법에 의한 지진시의 사면안정해석에 관하여 (Slope Stability Analysis Using Modified Seismic Intensity Method During Earthquake)

  • 오병현
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.124-131
    • /
    • 2000
  • Numerical analysis of slop stability is carried out using seismic intensity, modified seismic intensity, and response seismic coefficient methods. It is found by comparing each of method that minimum safety factor precedes the required safety factor. It is also proved during analysis that most conservative method is the earthquake response analysis method, next is the response seismic coefficient method, and last one is the seismic intensity method. Usually, seismic intensity method is applied in analysis of slop stability. However, in view of safety factor, modified seismic intensity method is more conservative than seismic intensity method. Also modified seismic intensity method is appropriate when height of structure analyzed is high enough.

  • PDF

순시 인텐시티 측정 기법의 개발 및 응용 (Development and Application of Measuring Method of Instantaneous Intensity)

  • 이장우;김영종;안병하;이운섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.560-563
    • /
    • 1997
  • Sound intensity method is well known as a visualization technique of sound field and sound propagation in noise control. Sound intensity is a vector quantity that describes the magnitude and the direction of net flow of acoustic energy at a given position. The current measuring method is expensive and difficult to identify the noise source exactly. In this paper, we have studied the noise source identification and the characteristics of noise source of rotary compressor for air conditioner using complex sound intensity method. The new method for instantaneous sound intensity is also proposed and it is useful for transient state and steady state. The criteria of these states select auto correlation coefficient. The advantage, simplicity and economic attribution of this method are verified by analyzing the characteristics of noise source with instantaneous sound intensity compared to mean sound intensity.

  • PDF

순시 인텐시티 측정 기법의 개발 및 응용 (Development and Application of Measuring Method for Instantaneous Intensity)

  • 이장우;안병하
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.960-963
    • /
    • 2003
  • Sound intensity method is well known as a visualization technique of sound field and sound propagation in noise control. Sound intensity is a vector quantity that describes the magnitude and the direction of net flow of acoustic energy at a given position. The current measuring method is expensive and difficult to identify the noise source exactly. In this paper, we have studied the noise source identification and the characteristics of noise source of rotary compressor for air conditioner using complex sound intensity method. The new method for instantaneous sound intensity is also proposed and it is useful for transient state and steady state. The criteria of these state, select auto correlation coefficient. The advantage, simplicity and economic attribution of this method are verified by analyzing the characteristics of noise source with instantaneous sound intensity compared to mean sound intensity.

  • PDF

복소음향 인텐시티법을 이용한 소음원검출의 시뮬레이션 및 실차응용 (Computer Simulation for Noise Source Identification and Application to Vehicle Using Complex Acoustic Intensity Method)

  • 오재웅;김상헌;안지훈
    • 한국자동차공학회논문집
    • /
    • 제5권3호
    • /
    • pp.171-171
    • /
    • 1997
  • Sound intensity distributions and energy flow in the near field of dipole source system and flat plate were investigated. First, the effectiveness of complex acoustic intensity was proved by using mathmatical and experimental methods in order to indentify noise sources and transmission paths of dipole field which is effected by the presence of neighbouring coherent sources. Next, analytical complex acoustic intensity method was discussed and the characteristics and energy flow of sound induced from the plate are clarified. The velocity of plate obtained from Finite Element Method was used for calculation of complex acoustic intensity in the near field. Finally experimental complex acoustic intensity method was applied to a passenger car. It can be seen that complex acoustic intensity method using both of active and reactive intensity is vital in devising a strategy for the identification and the reduction of vibration and noise.

혼합모드 균열의 응력확대계수 해석과 정도 개선에 대한 고찰 (Determination of S.I.F. for Mixed Mode Crack and Development of Accuracy)

  • 배원호
    • 한국산업융합학회 논문집
    • /
    • 제7권4호
    • /
    • pp.355-361
    • /
    • 2004
  • The finite element method were used to determine the stress intensity factor of cracked plate. The stress method, displacement method and J Integral are most popular finte element method. ANSYS proposed another a kind of displacement method. In this paper, it was examined that the accuracy and utility of the ANSYS method could believable to determine the stress intensity factors of centered inclined crack. Generally, inclined crack has two portion of stress intensity factors, tensile mode F1 and shear mode F2. For the purpose of increasing the accuracy of stress intensity factors, examined the effect of the numbers of nodes and elements, crack tip element size and number of partition of the crack tip vicinity. It was found that the method proposed by ANSYS is useful and has high accuracy. Accuracy of calculated stress intensity factors was increased by increase of the number of nodes and elements, and at the small size of crack tip elements can get more highly accuracy.

  • PDF

Two Dimensional Complex Sound Intensity를 이용한 압축기 소음원 규명에 관한 연구 (A Study on Noise Identification of Compressor Based on Two Dimensional Complex Sound Intensity)

  • 안병하;김영수
    • 한국정밀공학회지
    • /
    • 제17권1호
    • /
    • pp.83-92
    • /
    • 2000
  • Sound intensity method is well known as a visualization technique of sound field or sound propagation in noise control. Sound intensity or energy flux is a vector quantity which describes the amount and the direction of net flow of acoustic energy at a given position. Especially two dimensional sound intensity method is very useful in evaluating periodic characteristics and acoustic propagation mode of noise source. In this paper, we have studied the noise source Identification, acoustic sound field analysis, and characteristics of noise source of rotary compressor and scroll compressor for air conditioner using complex sound intensity method. Also we proposed a now method of time domain analysis which is used in evaluating of position of noise source in rotary and scroll compressor in this paper This paper presents the advantage, simplicity and economical efficiency of this method by analysing the characteristics of noise source with two dimensional complex sound intensity simultaneously.

  • PDF

Colour Linear Array Image Enhancement Method with Constant Colour

  • Ji, Jing;Fang, Suping;Cheng, Zhiqiang
    • Current Optics and Photonics
    • /
    • 제6권3호
    • /
    • pp.304-312
    • /
    • 2022
  • Digital images of cultural relics captured using line scan cameras present limitations due to uneven intensity and low contrast. To address this issue, this report proposes a colour linear array image enhancement method that can maintain a constant colour. First, the colour linear array image is converted from the red-green-blue (RGB) colour space into the hue-saturation-intensity colour space, and the three components of hue, saturation, and intensity are separated. Subsequently, the hue and saturation components are held constant while the intensity component is processed using the established intensity compensation model to eliminate the uneven intensity of the image. On this basis, the contrast of the intensity component is enhanced using an improved local contrast enhancement method. Finally, the processed image is converted into the RGB colour space. The experimental results indicate that the proposed method can significantly improve the visual effect of colour linear array images. Moreover, the objective quality evaluation parameters are improved compared to those determined using existing methods.

하수관거 통수능 해석을 위한 Huff 모형과 ABM 법의 적용성 분석 (Applicability of Huff Model & ABM Method for Discharge Capacity of Sewer Pipe)

  • 현인환;전승희;김두일
    • 상하수도학회지
    • /
    • 제36권4호
    • /
    • pp.229-237
    • /
    • 2022
  • The sewer capacity design have been based on the Huff model or the rational equation in South Korea and often failed to determine optimal capacity, resulting in frequent urban flooding or over-sizing. A time distribution of rainfall (i.e., Huff or ABM method) could be used instead of a rainfall hyetograph obtained from statistical analysis of previous rainfalls. In this study, the Huff method and the ABM method, which predict the time distribution of rain intensity, which are widely used to calculate sewage pipe drainage capacity using the SWMM, were compared with the standard rainfall intensity hyetograph of Seoul. If the rainfall duration was 30 minutes to 180 minutes, the rainfall intensity value calculated by the Huff model tended to be less than the rainfall intensity value of the standard rainfall intensity in the initial 5-10 minutes. As a result, more than 10% to 30% of under-design would be made. In addition, the rainfall intensity value calculated by the Huff model from the section excluding the initial 5-10 minutes of rainfall to the rainfall duration was calculated larger than the value using the standard rainfall intensity equation, which would result in an over-design of 10% to 30%. In the case of a relatively long rainfall duration of 360 minutes (6 hours) to 1,440 minutes (24 hours), it showed an lower rainfall intensity of 60 to 90% in the early stages of rainfall, but the problem of under-design had been solved as the rainfall duration time had elapsed. On the other hand, in the alternating block method (ABM) method, it was found that the rainfall intensity at the entire period at each assumed rainfall duration accurately matched the standard rainfall intensity hyetograph of Seoul.