• Title/Summary/Keyword: Intensity measures

Search Result 399, Processing Time 0.024 seconds

A Study on Indoor Position-Tracking System Using RSSI Characteristics of Beacon (비콘의 RSSI 특성을 이용한 실내 위치 추적 시스템에 관한 연구)

  • Kim, Ji-seong;Kim, Yong-kab;Hoang, Geun-chang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.17 no.5
    • /
    • pp.85-90
    • /
    • 2017
  • Indoor location-based services have been developed based on the Internet of Things technologies which measure and analyze users who are moving in their daily lives. These various indoor positioning technologies require separate hardware and have several disadvantages, such as a communication protocol which becomes complicated. Based on the fact that a reduction in signal strength occurs according to the distance due to the physical characteristics of the transmitted signal, RSSI technology that uses the received signal strength of the wireless signal used in this paper measures the strength of the transmitted signal and the intensity of the attenuated received signal and then calculates the distance between a transmitter and a receiver, which requires no separate costs and makes to implement simple measurements. It was applied calculating the value for the average RSSI and the RSSI filtering feedback. Filtering is used to reduce the error of the RSSI values that are measured at long distance.It was confirmed that the RSSI values through the average filtering and the RSSI values measured by setting the coefficient value of the feedback filtering to 0.5 were ranged from -61 dBm to - 52.5 dBm, which shows irregular and high values decrease slightly as much as about -2 dBm to -6 dBm as compared to general measurements.

Evaluation of Field Nonlinear Modulus of Subgrnde Soils Using Repetitive Static Plate Bearing Load Test (반복식 평판재하시험을 이용한 노상토의 현장 변형계수 평가)

  • Kim Dong-Soo;Seo Won-Seok;Kweon Gi-Chul
    • Journal of the Korean Geotechnical Society
    • /
    • v.21 no.6
    • /
    • pp.67-79
    • /
    • 2005
  • The field plate load test has a good potential for determining modulus since it measures both plate pressure and settlement. Conventionally the modulus has been assumed to be a constant secant value defined from the settlement of the plate at a given load intensity. A constant modulus (modulus of subgrade reaction, k), however, may not be a representative value of subgrade soil under working load. Field strain(o. stress)-dependent modulus characteristics of subgrade soils, at relatively low to intermediate strains, are important in the pavement design. In this study, the field strain dependent moduli of subgrade soils were obtained using cyclic plate load test. Testing procedure and data reduction method are proposed. The field crosshole and laboratory resonant column tests were also performed to determine field nonlinear modulus at $0.001\%\;to\;0.1\%$ strains, and the modulus values and nonlinear trends are compared to those obtained by cyclic plate load tests. Both modulus values match relatively well when the different state of stress between two tests was considered, and the applicability of field cyclic plate load test for determining nonlinear modulus values of subgrade soils is verified.

A Change of Turbidity on Forest Stands by Rainfall Characteristics in Small Watershed (산지소유역에 있어서 강우특성에 따른 임분별 탁도 변화)

  • Ma, Ho-Seop;Kang, Won-Seok;Kang, Eun-Min
    • Journal of Korean Society of Forest Science
    • /
    • v.101 no.3
    • /
    • pp.381-386
    • /
    • 2012
  • This study was carried out to clarify the turbidity change on three stands (Castanea crenata, Pinus densiflora and Plantation Land) by rainfall characteristics in small watershed. The change of turbidity showed in order of plantation land, Castanea stand and Pinus stand. The linear equations models between turbidity and rainfall intensity were able to account for 91% in Castanea stand, 80% in Pinus stand and 71% in plantation land. The linear equations models between turbidity and duration of rainfall were able to account for about 0-1% in three stands. The linear equations models between turbidity and preceding dry days were able to account for about 30% in three stands. The linear equations models between turbidity and accumulative rainfall were able to account for about 6-22% in three stands. The results indicates that soil runoff by land use and development of forest area could be applied to the mitigation measures such as afforestation and erosion check dam for erosion control and water quality management in small watershed.

Filed Applicability Evaluations of Restoration Material for Underground Cavities Formed by Ground Subsidence (지반침하로 인한 지하공동 복구재료의 현장적용성 평가)

  • Bang, Seongtaek;Baek, Seungju
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.3
    • /
    • pp.5-11
    • /
    • 2020
  • Recently, ground pits that have been occurring frequently in urban areas are hindering traffic flow and causing property damages and loss of human life, acting as factors that are threatening the safety of citizens. Therefore, sunken ground must be quickly restored and provisions must be made for additional damage but current domestic detailed standards regarding ground pits and accurate definitions regarding causes and measures to be taken for reoccurrences are lacking. Restoration methods of sunken ground include backfilling by reusing sunken soil or other fill material and paving the road and while this is the most often used method, this only prevents ground from sinking temporarily and can not serve as a fundamental solution. Also, additional ground pits can occur on ground that is reinforced using this method due to faulty backfill material or faulty hardening. This study used Eco-friendly High-Strength Material (EHSM) as restoration material that can be used in the restoration of underground cavities that have occurred due to ground subsidence to analyze the engineered characteristics of modified dredging clay and test pieces made from changed ratios of EHSM and weathered granite soil were uniaxial compression tests were conducted and freezing-thawing tests were conducted to study strength properties according to environmental changes of restoration material, and after tests were concluded by each level, uniaxial compression tests and dynamic elasticity tests were conducted for intensity analysis. Also, to evaluate strength characteristics of the restored ground, dynamic plate load tests were conducted to verify the improvement effectiveness of the restored ground.

Effectiveness of Cognitive Behavioral Therapy Techniques for Control of Pain in Lung Cancer Patients: An Integrated Review

  • Phianmongkhol, Yupin;Thongubon, Kannika;Woottiluk, Pakapan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.14
    • /
    • pp.6033-6038
    • /
    • 2015
  • Background: Experience of lung cancer includes negative impacts on both physical and psychological health. Pain is one of the negative experiences of lung cancer. Cognitive behavioral therapy techniques are often recommended as treatments for lung cancer pain. The objective of this review was to synthesize the evidence on the effectiveness of cognitive behavioral therapy techniques in treating lung cancer pain. This review considered studies that included lung cancer patients who were required to 1) be at least 18 years old; 2) speak and read English or Thai; 3) have a life expectancy of at least two months; 4) experience daily cancer pain requiring an opioid medication; 5) have a positive response to opioid medication; 6) have "average or usual" pain between 4 and 7 on a scale of 0-10 for the day before the clinic visit or for a typical day; and 7) able to participate in a pain evaluation and treatment program. This review considered studies to examine interventions for use in treatment of pain in lung cancer patients, including: biofeedback, cognitive/attentional distraction, imagery, hypnosis, and meditation. Any randomized controlled trials (RCTs) that examined cognitive behavioral therapy techniques for pain specifically in lung cancer patients were included. In the absence of RCTs, quasi-experimental designs were reviewed for possible conclusion in a narrative summary. Outcome measures were pain intensity before and after cognitive behavioural therapy techniques. The search strategy aimed to find both published and unpublished literature. A three-step search was utilised by using identified keywords and text term. An initial limited search of MEDLINE and CINAHL was undertaken followed by analysis of the text words contained in the title and abstract, and of the index terms used to describe the article. A second search using all the identified keywords and index terms was then undertaken across all included databases. Thirdly, the reference list of all identified reports and articles were searched for additional studies. Searches were conducted during January 1991- March 2014 limited to English and Thai languages with no date restriction. Materials and Methods: All studies that met the inclusion criteria were assessed for methodological quality by three reviewers using a standardized critical appraisal tool from the Joanna Briggs Institute (JBI). Three reviewers extracted data independently, using a standardized data extraction tool from the Joanna Briggs Institute (JBI). Ideally for quantitative data meta-analysis was to be conducted where all results were subject to double data entry. Odds ratios (for categorical data) and weighted mean differences (for continuous data) and their 95% confidence intervals were to be calculated for analysis and heterogeneity was to be assessed using the standard Chi-square. Where statistical pooling was not possible the finding were be presented in narrative form. Results: There were no studies located that met the inclusion requirements of this review. There were also no text and opinion pieces that were specific to cognitive behavioral therapy techniques pain and lung cancer patients.Conclusions: There is currently no evidence available to determine the effectiveness of cognitive behavioural therapy techniques for pain in lung cancer patients.

Deterioration of the Rock-carved Seated Buddha at Golguram Hermitage, Gyeongju and Effect of the Ethylsilicate Consolidant (경주 골굴암 마애여래좌상 구성암석의 손상과 에틸실리케이트 암석강화제의 효과)

  • Do, Jin Young
    • Journal of the Mineralogical Society of Korea
    • /
    • v.30 no.2
    • /
    • pp.71-81
    • /
    • 2017
  • Rock properties and the effects of chemicals that were used for conservation were studied for effective conservation treatment of Seated Buddha rock carving, which is composed of grayish white tuff, at Golguram Hermitage, Gyeongju. The rocks contain 3-5% montmorillonite, a swelling mineral and reacting with water, the d spacing of swelling minerals was increased (1.54-2.69%). On the one hand, the physical properties of the rock samples, such as surface hardness, water absorption rate, and porosity improved after the application of ethyl silicate-based stone strengthener. On the other, the interlayer of swelling minerals decreased and greater the of swelling mineral content, the greater is the extent of swelling (4.23-12.12%). When the ethyl silicate-based stone strengthener was applied after pretreatment with a swelling inhibitor, the physical properties were similar to those of the stone strengthener alone. There was no interlayer spacing change of swelling minerals due to swelling inhibition treatment; however, when the stone strengthener was applied after the swelling inhibitor, interlayer changes were similar to those when only the stone strengthener was treated (4.10-11.85%). Though the peak intensity of swelling minerals in X-ray diffraction pattern decreased, the effect of the swelling inhibitor was almost negligible. Therefore, it is not appropriate to use ethyl silicate-based stone strengthener for Golgulam rock containing swelling minerals and supplementing them with a swelling inhibition system is not effective. Because weathering rapidly progresses when swelling minerals contact moisture, for now, measures to prevent water contact, such as expansion of the canopy, are needed in the lower and side parts of the carving.

Application of Gamma Ray Densitometry in Powder Metallurgy

  • Schileper, Georg
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2002.07a
    • /
    • pp.25-37
    • /
    • 2002
  • The most important industrial application of gamma radiation in characterizing green compacts is the determination of the density. Examples are given where this method is applied in manufacturing technical components in powder metallurgy. The requirements imposed by modern quality management systems and operation by the workforce in industrial production are described. The accuracy of measurement achieved with this method is demonstrated and a comparison is given with other test methods to measure the density. The advantages and limitations of gamma ray densitometry are outlined. The gamma ray densitometer measures the attenuation of gamma radiation penetrating the test parts (Fig. 1). As the capability of compacts to absorb this type of radiation depends on their density, the attenuation of gamma radiation can serve as a measure of the density. The volume of the part being tested is defined by the size of the aperture screeniing out the radiation. It is a channel with the cross section of the aperture whose length is the height of the test part. The intensity of the radiation identified by the detector is the quantity used to determine the material density. Gamma ray densitometry can equally be performed on green compacts as well as on sintered components. Neither special preparation of test parts nor skilled personnel is required to perform the measurement; neither liquids nor other harmful substances are involved. When parts are exhibiting local density variations, which is normally the case in powder compaction, sectional densities can be determined in different parts of the sample without cutting it into pieces. The test is non-destructive, i.e. the parts can still be used after the measurement and do not have to be scrapped. The measurement is controlled by a special PC based software. All results are available for further processing by in-house quality documentation and supervision of measurements. Tool setting for multi-level components can be much improved by using this test method. When a densitometer is installed on the press shop floor, it can be operated by the tool setter himself. Then he can return to the press and immediately implement the corrections. Transfer of sample parts to the lab for density testing can be eliminated and results for the correction of tool settings are more readily available. This helps to reduce the time required for tool setting and clearly improves the productivity of powder presses. The range of materials where this method can be successfully applied covers almost the entire periodic system of the elements. It reaches from the light elements such as graphite via light metals (AI, Mg, Li, Ti) and their alloys, ceramics ($AI_20_3$, SiC, Si_3N_4, $Zr0_2$, ...), magnetic materials (hard and soft ferrites, AlNiCo, Nd-Fe-B, ...), metals including iron and alloy steels, Cu, Ni and Co based alloys to refractory and heavy metals (W, Mo, ...) as well as hardmetals. The gamma radiation required for the measurement is generated by radioactive sources which are produced by nuclear technology. These nuclear materials are safely encapsulated in stainless steel capsules so that no radioactive material can escape from the protective shielding container. The gamma ray densitometer is subject to the strict regulations for the use of radioactive materials. The radiation shield is so effective that there is no elevation of the natural radiation level outside the instrument. Personal dosimetry by the operating personnel is not required. Even in case of malfunction, loss of power and incorrect operation, the escape of gamma radiation from the instrument is positively prevented.

  • PDF

A Study about Improvement of Multiple Odor of Public Toilet (Dong-gu, Daejeon) (공중화장실 복합악취 및 개선에 관한 연구 (대전광역시 동구))

  • Jo, Soo-Jun;Shin, Je-Youn;Oh, Sang-Soo;Yu, Dae-Yong;Lee, Sung-Jae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.4
    • /
    • pp.240-245
    • /
    • 2015
  • This study aimed to provide the basic data to establish measures for the management of the public toilets and reduction of the offensive odor through the air dilution olfactory method and instrumental analysis about offensive odor dilution rate of public toilets, focusing on the Dong-gu, Daejeon Metropolitan City, Korea. The offensive odor intensities ranged from 10 degree to 669 degrees in the urinal toilets and from 31 to 464 in closet bowl toilets. Meanwhile, toilets that had offensive odor of more than 2.5, of which a civil complaint can be filed, were researched 6 (33%). Offensive odor intensities were different according to the closet bowl toilets of the flush, fermented and conventional methods and the year of their installation, but not according to the area of the toilets. As a result of the instrumental analysis targeting 6 public toilets to identify the offensive odor substance, the maximal concentration of $NH_3$ was 2.04 ppm and the average concentration was 0.67 ppm, but $H_2S$, $CH_3SH$ and $(CH_3)_3N$ were not detected. In the fermented and conventional public toilets were not soaps, air fresheners and wastebaskets. Just 50% of the flush toilets had toilet tissue.

Alteration of Forearm Local Temperature and Median Nerve Conduction Velocity by Therapeutic Ultrasound in Healthy Adult Subjects (초음파에 의한 전완 국소 온도와 정중 운동 신경전도 속도의 변화)

  • Jeon, Cha-Sun;Kim, Taek-Yean
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.12 no.1
    • /
    • pp.37-43
    • /
    • 2006
  • PURPOSE: Previous studies have documented the lack of ultrasound's non-thermal effects on nerve conduction using frequencies of 1 MHz and 870 kHz. The purpose of this study was to determine the biophysical effects of continuous ultrasound on median local forearm temperature and motor nerve conduction velocities using frequencies of 3.0 MHz. SUBJECTS: Twelve healthy subjects (6 males, 6 females, age $22.30{\pm}2.41$ yrs, weight $61.33{\pm}10.16$ kg, height $167.58{\pm}8.04$ cm) without a history of neurological or musculoskeletal injury to their dominant arm volunteered for this study. METHODS AND MATERIALS: Each subject received a total of five treatments, one each at .0, 0.5, 1.0, 1.5, 2.0 W/$cm^2$ of 3 MHz continuous ultrasound on the anterior surface of the middle area of dominant forearm for 10 minutes. Dependent measures for forearm local temperature and median motor nerve conduction velocity (MNCV) were taken pretreatment and immediately post-treatment. One-way ANOVA were used for each dependent measure. RESULTS: The posttreatment forearm local temperature were differed significantly (p<0.001) between intensities of ultrasound. The posttreatment forearm local temperature of the ultrasound treated with 1.0 w/$cm^2$, 1.5 w/$cm^2$ and 2.0 w/$cm^2$ were significantly higher than 0.5 w/$cm^2$ and 0.0 w/$cm^2$ of ultrasound (p<0.05). The posttreatment median MNCV were differed significantly from the respective pretreatment velocities (p<0.001). The MNCV of the ultrasound treated with 0.0 w/$cm^2$ and 0.5 w/$cm^2$ were significantly (p<0.05) slower than that observed pretreatment, while the three ultrasound intensities produced significantly increased posttreatment MNCV: 1.0 w/$cm^2$ and 1.5 w/$cm^2$ and 2.0 W/$cm^2$. The posttreatment MNCV at 2.0 w/$cm^2$ and 1.5 w/$cm^2$ was significantly faster than that at 0 w/$cm^2$, 0.5 w/$cm^2$ and 1.0 w/$cm^2$ (p<0.05), the MNCV at 1.0 w/$cm^2$ was significantly faster than that associated with 0 w/$cm^2$ and 0.5 w/$cm^2$ of ultrasound (p<0.05). CONCLUSIONS: The decreased median motor forearm local temperature and MNCV of the ultrasound treated with 0.0 w/$cm^2$ and 0.5 w/$cm^2$ were attributed to the cooling effect by ultrasound transmission gel. Local forearm temperature and nerve conduction velocity were directly related to the intensity of ultrasound. Alterations in MNCV from ultrasound on healthy nerves appeared to be related to temperature changes induced by thermal effects of ultrasound.

  • PDF

Standardization of Trail Difficulty based on Energy Consumption (에너지 소모량에 기초한 탐방로 난이도 표준화 연구)

  • Hong, Suk-Hwan;Kwon, Tae-Ho;Choi, Song-Hyun;Kim, Kyung-Tae;Kim, Dong-Pil
    • Korean Journal of Environment and Ecology
    • /
    • v.29 no.4
    • /
    • pp.626-635
    • /
    • 2015
  • Recently, the number of trail users in Korea has risen tremendously. Consequently, the cost of safety measures related to hiking is sharply increasing. Despite the safety cost input, the number of heart-related adverse events has been not decreasing. Therefore, this research aims to suggest the use of objective and quantitative trail use information in terms of course difficulty. The study site is Jirisan Dullegil (Jirisan Forest Trail). The currently available trail difficulty information either provides the difficulty rating in terms of 3 to 5 levels according to several empirical difficulty factors reported by staff who maintain the forest or simply states the distance of each trail. Thus, many trail visitors feel a great gap between the given information and actual difficulties they experience. In this study, we tried to assess the degree of difficulty by actual energy consumption. Calculating the volumetric oxygen consumption (VOC) by the distance and gradient not only makes possible an absolute rating but a comparison among the trails as well. Also, it is highly effective to simply describe the exercise intensity of a certain trail. Further, it is easy to check the VOCs' changes by switching the start-end points of the same trail. Providing the trail information of VOCs by sections and directions, we expect to prevent heart-related accidents.