• Title/Summary/Keyword: Intensity limit

Search Result 360, Processing Time 0.024 seconds

Fragility Assessment of Damaged Piloti-Type RC Building With/Without BRB Under Successive Earthquakes (연속 지진에 의하여 손상된 필로티 RC 건축물의 BRB 보강 전/후의 취약성 평가)

  • Shin, Jiuk;Kim, JunHee;Lee, Kihak
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.17 no.3
    • /
    • pp.133-141
    • /
    • 2013
  • This paper presents the seismic evaluation and prediction of a damaged piloti-type Reinforced Concrete (RC) building before and after post-retrofitting under successive earthquakes. For considering realistic successive earthquakes, the past records measured at the same station were combined. In this study, the damaged RC building due to the first earthquake was retrofitted with a buckling-restrained brace (BRB) before the second earthquake occurred. Nonlinear Time History Analysis (NTHA) was performed under the scaled intensity of the successive ground motions. Based on the extensive structural response data obtained form from the NTHA, the fragility relationships between the ground shaking intensity and the probability of reaching a pre-determined limit state was were derived. In addition, The the fragility curves of the pre-damaged building without and with the BRBs were employed to evaluate the effect of the successive earthquakes and the post-retrofit effect. Through the seismic assessment subjected to the successive records, it was observed that the seismic performance of the pre-damaged building was significantly affected by the severity of the damage from the first earthquake damages and the hysteresis behavior of the retrofit element.

A Chemiluminescence Method for the Determination of Ascorbic Acid based upon Its Reaction with Cerium(IV) in the Presence of $Ru(bipy)_3^{2+}$

  • Lee, Sang-Hak;Bae, Hyun-Sook;karim, Mohammad-Mainul;Kim, Chang-Jin;Kim, Young-Sun;Lee, Hyun-Sook;Hong, Sang-Beom
    • Journal of Photoscience
    • /
    • v.12 no.3
    • /
    • pp.149-153
    • /
    • 2005
  • A chemiluminescence (CL) method for the determination of ascorbic acid was proposed, which is based on the enhancement of the CL intensity of $Ru(bipy)_3^{2+}$ - Ce (IV) system with the addition of ascorbic acid. The CL intensity is proportional to the concentration of ascorbic acid in the range of $1{\times}10^{-10}\;to\;1{\times}10^{-5}M$ with a correlation coefficient of 0.9985. The detection limit is $3{\times}10^{-11}M$. The relative standard deviation (R.S.D.) of 10 determinations of 0.1 mM ascorbic acid was 1.75%. The proposed method has been successfully applied to the determination of ascorbic acid in the commercia] drinks. The possible mechanism of the CL reaction was studied.

  • PDF

Optical Probe for Determination of Chromium(III) Ion in Aqueous Solution Based on Sol-Gel-Entrapped Lucigenin Chemiluminescence

  • Li, Ming;Kwak, Jun-Hee;Kim, Chang-Jin;Lee, Sang-Hak
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2003.11a
    • /
    • pp.103-108
    • /
    • 2003
  • A method to determine chromium(III) ion in aqueous solution by chemiluminescence method using a lucigenin entrapped silica sol-gel film has been studied. An optical probe for chromium(III) ion has been prepared by entrapping lucigenin into silica sol-gel film coated on a glass support by dip coating. The chromium(III) optical sensor is based on the catalytic effect of chromium(IIII) ion on the reaction between lucigenin and hydrogen peroxide in basic solutions. The effects of Nafion, DMF and Triton X-100 were investigated to find the optimum condition to minimize cracking and leaching from the probe. The effects of pH and concentrations of lucigenin and hydrogen peroxide on the chemiluminescence intensity were investigated. The chemiluminescence intensity was increased linearly with increasing chromium(III) concentration from $2.5{\times}10^{-4}$M to $8.0{\times}10^{-7}$M and the detection limit was $4.0{\times}10^{-7}$M.

  • PDF

Experimental Evaluation of Fatigue Threshold for SA-508 Reactor Vessel Steel (SA-508 압력용기용 강에 대한 피로균열성장 하한계 조건의 실험 평가)

  • Rhee, Hwan-Woo
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.160-167
    • /
    • 2012
  • This paper is concerned with a particular fracture mechanics parameter ${\Delta}K_{th}$, known as the 'threshold stress intensity range', or 'fatigue threshold'. This threshold ${\Delta}K_{th}$ constitutes, as it were, a hinge between the notion of crack initiation and the notion of crack growth. It has often been thought that, like the endurance limit, it could be an intrinsic criterion of the material. The study was conducted on a SA-508 pressure vessel steel used in the nuclear power industry. This material exhibits a typical threshold effect in the range of the crack growth rates which were determined; that is, below approximately $da/dN=10^{-6}mm/cycle$, the slope of the da./dN versus ${\Delta}K$ curve is almost vertical. The value of ${\Delta}K_{th}$ was determined at a growth rate of $10^{-7}$ mm/cycle according to the ASTM Standard for threshold testing. The fatigue threshold values are in the range 21 $kg/mm^{3/2}$ to 12 $kg/mm^{3/2}$ depending on the stress ratio effect.

Spectrofluorimetric determination of EDTA with Cu(II)-tiron chelate (Cu(II)-tiron 킬레이트를 이용한 EDTA 분광형광법 정량)

  • Choi, Hee-Seon
    • Analytical Science and Technology
    • /
    • v.24 no.3
    • /
    • pp.231-235
    • /
    • 2011
  • A spectrofluorimetric method for the determination of EDTA in real samples such as mayonnaise, powder detergent and cleansing cream with tiron (4,5-dihydroxy-1,3-benzenedisulfonic acid) as a fluorimetric reporter was developed. When tiron is chelated with Cu(II), the fluorescent intensity is decreased by a quenching effect. However, when Cu(II)-tiron chelate reacts with EDTA, fluorescent intensity is increased as tiron is released. Several experimental conditions such as pH of the sample solution, the amount of Cu(II), the amount of tiron, heating temperature and heating time were optimized. Fe(III) interfered more seriously than any other ions, interference of Fe(III) could be disregarded, because Fe(III) was scarcely contained in selected real samples. The linear range of EDTA was from $8.0{\times}106{-8}\;M$ to $2.0{\times}10^{-6}\;M$. With this proposed method, the detection limit of Fe(III) was $5.2{\times}10^{-8}\;M$. Recovery yields of 92.7~99.3% were obtained. Based on experimental results, it is proposed that this technique can be applied to the practical determination of EDTA.

Chemiluminescence Determination of Balofloxacin Based on Europium (III)-Sensitized KBrO3-Na2S2O4 Reaction in Micellar Medium

  • Zhao, Fang;Qi, Yu;Xiong, Wei
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.204-208
    • /
    • 2012
  • A novel chemiluminescence (CL) flow injection method for the determination of balofloxacin is described. The method is based on the weak CL signal arising from the reaction of $KBrO_3$ with $Na_2S_2O_4$ in acidic medium being significantly enhanced by balofloxacin in the presence of europium (III) ion and sodium dodecyl benzene sulfonate (SDBS). The experimental conditions that affected CL intensity were carefully optimized and the CL reaction mechanism was briefly discussed. Under the optimum conditions, the relative CL intensity was proportional to the concentration of balofloxacin in the range of $7.0{\times}10^{-11}$ to $3.0{\times}10^{-7}g\;mL^{-1}$. The detection limit was $2.7{\times}10^{-11}g\;mL^{-1}$ and the relative standard deviation was 2.1% for $7.0{\times}10^{-10}g\;mL^{-1}$ balofloxacin (n = 13). The proposed method was successfully applied to the determination of balofloxacin in pharmaceutical formulations and biological fluids.

A New Chemiluminescence Method for Determination of Cytosine Arabinoside in Pharmaceutical Preparations

  • Cai, Z.;Zhang, X.;Lu, D.F.;Gan, J.N.
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.1
    • /
    • pp.171-176
    • /
    • 2012
  • A novel chemiluminescence (CL) system was established for the determination of cytosine arabinoside (Ara-C) in pharmaceutical preparations. It was showed that a clear CL signal was observed when Eosin Y mixed with Fenton reagent. The CL intensity was decreased significantly when Ara-C was added to the reaction system and partially scavenged the hydroxyl radicals in the solution. The extent of decrease in the CL intensity had a good stoichiometrical relationship with the Ara-C concentration. Based on this, we developed a new method for the determination of Ara-C using a flow injection analysis (FIA) technique with CL detection. Under the optimal conditions, the linear range of Ara-C concentration was $6.0{\times}10^{-9}\sim1.0{\times}10^{-7}mol/L$ (R = 0.9982) with a detection limit of $7.6{\times}10^{-10}mol/L$ (S/N=3), the RSD was 5.6% for $6.0{\times}10^{-8}mol/L$ Ara-C (n = 11). The method was successfully applied to the determination of Ara-C in injection samples. The possible chemiluminescence reaction mechanism was discussed.

Fragility Analysis of Staggered Wall Structures (격간벽 구조의 취약도 해석)

  • Beak, Donggirl;Kwon, Kwangho;Kim, Jinkoo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.5
    • /
    • pp.397-404
    • /
    • 2012
  • Fragility curves show the probability of a system reaching a limit state as a function of some measure of seismic intensity. To obtain fragility curves of six and twelve story staggered wall structures with middle corridor, incremental dynamic analyses were carried out using twenty two pairs of earthquake records, and their failure probabilities for various intensity of seismic load were investigated. The performances of staggered wall structures with added columns along the central corridor and the structures with their first story walls replaced by columns were compared with those of the regular staggered wall structures. Based on the analysis results it was concluded that staggered wall structures with central columns have the largest safety margin for the same level of seismic load.

Fatigue Characteristics of SPFC590 Laser Welded Sheet Metal for Automobile Body Panel (자동차 차체용 SPEC590강 레이저 용접판재의 피로특성)

  • 한문식;이양섭
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.11 no.1
    • /
    • pp.143-150
    • /
    • 2003
  • Experimental research has been carried out to investigate the characteristics of the fatigue crack initiation and propagation behavior of Tailor Welded Blank(TB) sheet used for vehicle body. We used three types of specimens which were machined of the same base metal: one is 1.4mm thick, another is 1.6mm thick, and the third(TB specimen) is laser-welded of two specimens(1.4mm and 1.6mm thick ones). The results of tensile and hardness test indicate that the yield strength of the TB specimen is the highest, and the hardness around welding bead is higher than that of base metal. Fatigue strength and fatigue limit of the TB specimen are much superior to those of the base metal up to $10^6$ cycles. The fatigue crack propagation of the heat-affected zone of the TB specimen is slower than that of the base metal. Welding bead has the fastest crack Propagation in the low stress intensity factor range$(\DeltaK)$ region, but the slowest in the high $\DeltaK$ region. The fatigue propagation characteristic of the TB specimen is relatively stable in comparison with that of the base metal in the high ${\Delta}K$ region around over $28MPa\sqrt{m}$.

Effect of the Hose Slurry Spreader on Oder Reduction (호스지표살포기의 악취감소효과 분석)

  • 오인환;김기덕
    • Journal of Animal Environmental Science
    • /
    • v.7 no.2
    • /
    • pp.119-126
    • /
    • 2001
  • For the odor test, it was chosen the conventional spreader, the hose spreader, and its combination with disk harrow and spring harrow as a slurry spreader. By the odor tester (Kalmor-$\sum$) with dairy slurry, the conventional spreader has the average $\sum$ value of 270, which means that one fells substantial odor and torment. In the cases of hose spreader and its combination with disk harrow, $\sum$ value was 217 and 182 respectively, which means a normal person does not smell any odor. Spreading the swine slurry with a conventional spreader shows $\sum$ value of 440, which means one feels unpleasant. The hose spreader shows $\sum$ value of 258, which lies in the limit one feels some odor and torment. Its combination with disk harrow has $\sum$ value 184, which means that a normal person can not smell any more. For the conventional spreader, the odor intensity indices from air dilution sensual test and 3 point odor bag as a sensual test were 66.9 and 35.4 respectively. On the other hand, the indices were 9.65 and 11.10 by hose spreader and its combination with disk harrow, which were lower than that of the regulation for industry. Therefore, the developed hose spreader showed an excellent effect on decreasing odor. The correlation between the results from odor tester and 3 point odor bag has shown 0.997 by swine slurry.

  • PDF