• Title/Summary/Keyword: Intensity Difference

Search Result 1,921, Processing Time 0.031 seconds

The Study on Receptive Attitude of Advertising Message Forms and Information Sources According to SNS' Type and Use Intensity (SNS 유형과 이용강도에 따른 광고 메시지 형태 및 정보원별 수용태도에 관한 연구)

  • Kim, Hwa-Dong
    • Journal of Digital Convergence
    • /
    • v.16 no.11
    • /
    • pp.255-265
    • /
    • 2018
  • This study investigated what kind of message forms and information sources more effect according to SNS' type and use intensity. To this end, this study did experimental analysis using collected data by survey which manufactured message forms and situational contents of information sources. According to analysis results, the effect of message forms showed difference according to SNS' type and use intensity. Realistic message showed greater effect in interest-based SNS and high use intensity. Evaluative message showed greater effect in relation-based SNS regardless of use intensity. The effect of information sources showed difference according to SNS' type. Friend or college and knower showed greater effect in relation- based SNS, and company showed greater effect in interest-based SNS. In the case of use intensity, friend or college showed the greatest effect without difference. Such results can provide a practical contribution in planning SNS advertising strategy. Future Studies need to expand survey variously into SNS and subject.

Physiological Index of the Elderly with Diabetes According to Dance Based Low Intensity Combined Kinesitherapy (무용기반 저강도 복합운동요법이 당뇨노인의 생리적 지표에 미치는 효과)

  • Kim, Su-Jin
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.5
    • /
    • pp.683-694
    • /
    • 2018
  • The purpose of this study was to investigate the effect of low intensity combined kinesitherapy on type 2 diabetes mellitus and to compare the effects of exercise and methodology aspects, the difference in the post - test scores between fasting glucose and blood lipids in the control group (exercise group) and the control group (exercise group) that prescribed the dance - exercise and low intensity combined exercise for the elderly diabetic patients for 12 weeks sample t-test. the main results of the study are summarized as follows. first, fasting blood sugar showed difference in pre - post - difference of group compared to control group. second, the total cholesterol was found to have a statistically significant difference in the experimental group from pre - post - difference. third, the neutral region showed no statistically significant differences in both experimental and comparator groupsfrom pre - post - difference. fourth, high-density lipoprotein cholesterol levels showed no statistically significant difference in both experimental and comparator groups from pre - post - difference. fifth, low density lipoprotein cholesterol showed statistically significant difference in the experimental group from pre - post - difference group. in conclusion, this study is significant in that the combined effects of dance - motion activities and low intensity combined exercise for elderly with type 2 diabetes were quantitatively proved by using physiological index who had not been treated previously.

Simultaneous Detection Properties of Organic Vapor, Pressure Difference and Magnetic Field using a Rugate-structured Free-standing Porous Silicon Film (Rugate 구조를 갖는 자립형 다공성 실리콘 박막을 이용한 유기 증기, 압력차, 자기장의 동시 감응 특성)

  • Han, Seong-Beom;Lee, Ki Won
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.3
    • /
    • pp.186-191
    • /
    • 2017
  • In this study, we investigated the simultaneous detection properties of organic vapor, pressure difference, and magnetic field using a single rugate-structured free-standing porous silicon (RFPS) thin film. Both the wavelength and the intensity of the rugate peaks were changed in the reflectivity spectrum measured at the thin film surface while the organic vapor was exposed to the RFPS thin film. However, when the pressure difference and the magnetic field were exposed to the film, only the rugate peak intensity was changed. Therefore, it is possible to distinguish whether or not the organic vapor is detected by simultaneously changing the rugate peak wavelength and intensity. In addition, a method of distinguishing between the pressure difference and the magnetic field detection signal has been derived by rapidly modulating the direction of the magnetic field. This study shows that it is possible to simultaneously detect and distinguish various objects using a single RFPS thin film, and it is found that porous silicon can be utilized as a sensor sufficiently.

Comparative Analysis of Pain Disorder Factors and Subjective Pain Reduction Effect after Functional Adjustment Procedure Therapy for Shoulder Pain Patients (직장인 어깨 통증 환자의 기능교정 치료 후 통증 장애 요인과 자각적 통증 감소 효과 비교분석)

  • Kim, Hee-Hyeon;Lim, Dong-Ho
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.15 no.4
    • /
    • pp.87-99
    • /
    • 2020
  • PURPOSE: This study examines the therapeutic effect of functional adjustment procedure therapy (FAPT), by comparatively analyzing behavioral disorders due to shoulder pain and subjective pain intensity subsequent to therapy, in patients with shoulder pain. METHODS: The intervention was performed on 48 employee patients with shoulder pain, Patients were administered 16 sessions of FAPT for 8 weeks, twice a week for 30 minutes per session. This study applied the neck pain and disability scale (NPDS) as a measurement tool, and used the questionnaire to measure subjective pain intensity to investigate the difference before and after administering FAPT to employee patients with shoulder pain. RESULTS: Statistically significant difference was obtained between the mean difference in shoulder pain disorder, before and after FAPT. Assessing gender and age differences in the reduction effect of shoulder pain, showed significant difference in 8 of the 10 factors examined. Finally, examining the difference in the effect of reducing subjective shoulder pain by gender and age, we observed that gender-based disability reduction was significant for all 12 factors examined. CONCLUSION: Taken together, the results of this study, validate the therapeutic efficacy of FAPT for patients with shoulder pain. We believe that this data will provide basic information to understand the health conditions and psychological variables of patients with shoulder pain.

Analysis of the Effect of Heat Island on the Administrative District Unit in Seoul Using LANDSAT Image (LANDSAT영상을 이용한 서울시 행정구역 단위의 열섬효과 분석)

  • Lee, Kyung Il;Ryu, Jieun;Jeon, Seong Woo;Jung, Hui Cheul;Kang, Jin Young
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_3
    • /
    • pp.821-834
    • /
    • 2017
  • The increase in the rate of industrialization due to urbanization has caused the Urban Heat Island phenomenon where the temperature of the city is higher than the surrounding area, and its intensity is increasing with climate change. Among the cities where heat island phenomenon occurs, Seoul city has different degree of urbanization, green area ratio, energy consumption, and population density in each administrative district, and as a result, the strength of heat island is also different. So It is necessary to analyze the difference of Urban Heat Island Intensity by administrative district and the cause. In this study, the UHI intensity of the administrative gu and the administrative dong were extracted from the Seoul metropolitan area and the differences among the administrative districts were examined. and linear regression analysis were conducted with The variables included in the three categories(weather condition, anthropogenic heat generation, and land use characteristics) to investigate the cause of the difference in heat UHI intensity in each administrative district. As a result of analysis, UHI Intensity was found to be different according to the characteristics of administrative gu, administrative dong, and surrounding environment. The difference in administrative dong was larger than gu unit, and the UHI Intensity of gu and the UHI Intensity distribution of dongs belonging to the gu were also different. Linear regression analysis showed that there was a difference in heat island development intensity according to the average wind speed, development degree, Soil Adjusted Vegetation Index (SAVI), Normalized Difference Built-up Index (NDBI) value. Among them, the SAVI and NDBI showed a difference in value up to the dong unit and The creation of a wind route environment for the mitigation of the heat island phenomenon is necessary for the administrative dong unit level. Therefore, it is considered that projects for mitigating heat island phenomenon such as land cover improvement plan, wind route improvement plan, and green wall surface plan for development area need to consider administrative dongs belonging to the gu rather than just considering the difference of administrative gu units. The results of this study are expected to provide the directions for urban thermal environment design and policy development in the future by deriving the necessity of analysis unit and the factors to be considered for the administrative city unit to mitigate the urban heat island phenomenon.

Oscillator Strengths and Intensity Parameters of Ln(III) Complexes with 12-Crown-4 and 15-Crown-5 Ethers in Acetonitrile (Ln = Ho and Er)

  • 강준길;윤수경;김은정;김종구;김윤두
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.3
    • /
    • pp.232-237
    • /
    • 1995
  • The absorption spectra of holmium nitrate and erbium nitrate and the difference absorption spectra of their complexes with crown ethers were measured in acetonitrile. The crown ethers used in this study are 12-crown-4 and 15-crown-5. The oscillator strengths for the 4f→4f multiplet-to-multiplet transitions are empirically determined from the absorption spectra in combination with the difference spectra. The intensity parameters Ωλ (λ=2, 4, 6) for the systems are also evaluated by applying the Judd-Ofelt theorem to the observed oscillator strengths. The values of the intensity parameters are compared and discussed to investigate the sensitivity of the intensity parameters to the ligand environment.

Evaluation of Muscle Activity according to Exercise Intensity during the Deadlift and Upright Row (데드리프트와 업라이트로우 시 운동강도에 따른 근활성도 평가)

  • Cho, Won Jun;Song, Ju Won;Choi, Myung Soo;Kim, Nam Yim;Kim, Ryong;Lee, Chang Min;Hong, Jae Heon;Kang, Gun Woo;Moon, Young Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.4
    • /
    • pp.270-275
    • /
    • 2021
  • Objective: The purpose of this study was to evaluate 16 muscles activity according to three exercise intensity when performing Deadlift and Upright row. Method: To accomplish the purpose of the study, subjects (n=10) were performed Electromyography (EMG) measurement for 16 different muscles. The experimental movements were Deadlift and Upright row, measured five times for each intensity (40%, 60%, 80%) of 1RM. This study normalized the EMG values through RVC for comparative analysis. Results: The results were summarized as follows: As a result of Deadlift, there was significant difference in the mean EMG value according to the exercise intensity in all muscles except RA, PM and BB (p<.05). As a result of Upright row, There was significant difference in the mean EMG value according to the exercise intensity in all muscles except BF, TA, GN, RA and UT (p<.05). Conclusion: This study allowed us to know the activities of major muscles according to the exercise intensity for 16 different muscles when performing Deadlift and Upright row.

Improvement of the Dose Calculation Accuracy Using MVCBCT Image Processing (Megavoltage Cone-Beam CT 영상의 변환을 이용한 선량 계산의 정확성 향상)

  • Kim, Min-Joo;Cho, Woong;Kang, Young-Nam;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.62-69
    • /
    • 2012
  • The dose re-calculation process using Megavoltage cone-beam CT images is inevitable process to perform the Adaptive Radiation Therapy (ART). The purpose of this study is to improve dose re-calculation accuracy using MVCBCT images by applying intensity calibration method and three dimensional rigid body transform and filtering process. The three dimensional rigid body transform and Gaussian smoothing filtering process to MVCBCT Rando phantom images was applied to reduce image orientation error and the noise of the MVCBCT images. Then, to obtain the predefined modification level for intensity calibration, the cheese phantom images from kilo-voltage CT (kV CT), MVCBCT was acquired. From these cheese phantom images, the calibration table for MVCBCT images was defined from the relationship between Hounsfield Units (HUs) of kV CT and MVCBCT images at the same electron density plugs. The intensity of MVCBCT images from Rando phantom was calibrated using the predefined modification level as discussed above to have the intensity of the kV CT images to make the two images have the same intensity range as if they were obtained from the same modality. Finally, the dose calculation using kV CT, MVCBCT with/without intensity calibration was applied using radiation treatment planning system. As a result, the percentage difference of dose distributions between dose calculation based on kVCT and MVCBCT with intensity calibration was reduced comparing to the percentage difference of dose distribution between dose calculation based on kVCT and MVCBCT without intensity calibration. For head and neck, lung images, the percentage difference between kV CT and non-calibrated MVCBCT images was 1.08%, 2.44%, respectively. In summary, our method has quantitatively improved the accuracy of dose calculation and could be a useful solution to enhance the dose calculation accuracy using MVCBCT images.

A Study of Influencing Factors in Acupuncture De Qi Sensation (득기 감각에 영향을 미치는 인자에 대한 연구)

  • Shin, Kyung Min;Jung, Dal Lim;Kim, Eun Jung;Lee, Seung Deok
    • The Journal of Korean Medicine
    • /
    • v.34 no.1
    • /
    • pp.15-28
    • /
    • 2013
  • Objectives: The purpose of this study was to investigate the differences in kind, intensity and depth of de Qi sensation by patients' gender, age, BMI and sensitivity. Methods: Sixty-four healthy volunteers (mean age $26.51{\pm}4.72$, range 22-39) who had been studying anatomy, meridianology, acupuncture & moxibustion for more than five years at Dongguk University, Go-yang, Korea, were invited to take part in an investigation of the sensations associated with acupuncture needling. Needling was self-administered on Hegu (LI4) in the hand and Zusanli (ST36) in the leg randomly. After obtaining de Qi, the participants were asked the kind, intensity and depth of de Qi sensation. Results: There was no statistically significant difference in the kind of de Qi sensation found by acupoints and needling methods (p>0.05). Hegu (LI4) was found to be significantly higher in the intensity (p<0.001), and the depth of de Qi sensation was significantly higher in Zusanli (ST36) than Hegu (LI4) (p<0.001). There was statistically significant difference found in the intensity of de Qi sensation by depth and sensitivity (p<0.05). In the depth of de Qi sensation, there was statistically significant difference found by sensitivity (p<0.05). In de Qi sensation of practitioners, there was statistically significant difference found by gender, BMI, the intensity of de Qi sensation (VAS) and sensitivity. Conclusions: Further study involving acupuncture de Qi sensation and the influencing factors is needed.

The Effects of Transcranial Direct Current Stimulation Combined High Intensity Interval Training on Aerobic Exercise Capacity of the Soccer Player (tDCS를 결합한 고강도 인터벌 훈련이 축구선수의 유산소 운동능력에 미치는 영향)

  • Yang, Dae-Jung;Uhm, Yo-Han
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.4
    • /
    • pp.105-117
    • /
    • 2021
  • Purpose : This study examined the effect of transcranial direct current stimulation (tDCS) combined high intensity interval training (HIIT) on the aerobic exercise capacity of college soccer players. Methods : The subjects of this study were 30 college soccer players. They were divided into a high intensity interval training group combining transcranial direct current stimulation (Group I) and a high intensity interval training group (Group II). Each group had 15 subjects randomly assigned. After receiving general soccer training, each group additionally received high intensity interval training combined with transcranial direct current stimulation and high intensity interval training for 30 minutes 5 times a week for 8 weeks. Their VO2max and 20 meter shuttle run test, Yo-Yo intermittent recovery test were analyzed before the intervention. After 8 weeks of intervention, the above items were re-measured and an intergroup analysis was performed. Results : As a result of comparative analysis of VO2max intake between groups, 20 meter shuttle run test and Yo-Yo intermittent recovery test, a statistically significant difference was found. The high intensity interval training group (Group I) combined with transcranial direct current stimulation showed a significant difference in aerobic exercise capacity compared to the high intensity interval training group (Group II). Conclusion : These results showed that high intensity interval training group combined with transcranial direct current stimulation was more effective for aerobic exercise. Based on this study, this study proposes an effective program for patients as well as elite athletes. In the future, it is necessary to develop an effective transcranial direct current stimulation program and to study how to apply it for various patients.