• Title/Summary/Keyword: Intensity Difference

Search Result 1,938, Processing Time 0.026 seconds

Observations of Oxygen Administration Effects on Visuospatial Cognitive Performance using Time Course Data Analysis of fMRI (뇌기능 자기공명영상의 시계열 신호 분석에 의한 공간인지과제 수행시 산소 공급의 효과 관찰)

  • Sohn Jin-Hun;You Ji-Hye;Eom Jin-Sup;Lee Soo-Yeol;Chung Soon-Cheol
    • Investigative Magnetic Resonance Imaging
    • /
    • v.9 no.1
    • /
    • pp.9-15
    • /
    • 2005
  • Purpose : This study attempted to investigate the effects of supply of highly concentrated $(30\%)$ oxygen on human ability of visuospatial cognition using time course data analysis of functional Magnetic Resonance Imaging (fMRI). Materials and Methods : To select an item set in the visuospatial performance test, two questionnaires with similar difficulty were developed through group testing. A group test was administered to 263 college students. Two types of questionnaire containing 20 questions were developed to measure the ability of visuospatial cognition. Eight college students (right-handed male, average age of 23.5 yrs) were examined for fMRI study. The experiment consisted of two runs of the visuospatial cognition testing, one with $21\%$ level of oxygen and the other with $30\%$ oxygen level. Each run consisted of 4 blocks, each containing control and visuospatial items. Functional brain images were taken from 37 MRI using the single-shot EPI method. Using the subtraction procedure, activated areas in the brain during visuospatial tasks were color-coded by t-score. To investigate the time course data in each activated area from brain images, 4 typical regions (cerebellum, occipital lobe, parietal lobe, and frontal lobe) were selected. Results : The average accuracy was $50.63{\pm}8.63$ and $62.50{\pm}9.64$ for $21\%\;and\;30\%$ oxygen respectively, and a statistically significant difference was found in the accuracy between the two types of oxygen (p<0.05). There were more activation areas observed at the cerebellum, occipital lobe, parietal lobe and frontal lobe with $30\%$ oxygen administration. The rate of increase in the cerebellum, occipital lobe and parietal lobe was $17\%$ and that of the frontal lobe, $50\%$. Especially, there were increase of intensity of BOLD signal at the parietal lobe with $30\%$ oxygen administration. The increase rate of the left parietal lobe was $1.4\%$ and that of the right parietal lobe, $1.7\%$. Conclusion : It is concluded that while performing visuospatial tasks, high concentrations of oxygen administration make oxygen administration sufficient, thus making neural network activate more, and the ability to perform visuospatial tasks increase.

  • PDF

Physicochemical Characteristics and Sensory Properties of Commercial Mukeunji Products (국내 시판 묵은지의 이화학적 및 관능적 특성)

  • Hur, Sung-Won;Ko, Myeung-Sin;Kim, Mi-Ran;Lee, Hye-Ran;Chung, Seo-Jin;Cho, Mi-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.44 no.5
    • /
    • pp.702-708
    • /
    • 2015
  • The aim of this study was to investigate the physicochemical characteristics of commercial Mukeunji product along with its sensory properties. Six different types of commercial Mukeunji products were purchased through an on-line market, and each product had a different fermentation period. General commercial Baechu Kimchi was compared with commercial Mukeunji products in order to standardize quality properties of Mukeunji. As a result, commercial Mukeunji showed a lower pH value (pH 3.96, mean value) than commercial Baechu Kimchi (pH 5.92), whereas commercial Mukeunji samples showed higher acidity and salinity. Color values (L, a, and b) of commercial Mukeunji decreased as the storage period increased. Hardness and thickness of commercial Mukeunji showed a lower range compared to Baechu Kimchi. The reducing sugar content decreased as the storage period of commercial Mukeunji increased. Acetic, lactic, and succinic acids were detected in commercial Mukeunji samples, whereas citric acid and malic acid were additionally detected in Baechu Kimchi. Commercial Mukeunji samples showed lower contents of acetic and succinic acid and higher content of lactic acid than Baechu Kimchi. Commercial Mukeunji samples showed a significant difference in all descriptive sensory attributes except for bitterness. Overall intensity, sourness, moldy odor, redness, sour smell, saltiness, and carbonated taste increased as the storage period increased, whereas cabbage flavor, crispiness, sweetness, firmness, and savory taste decreased as the storage period increased.

Diel Horizontal Migration of Planktonic Copepods in the Surf Zone of Yongil Bay, Korea (영일만 쇄파대에 나타나는 부유성 요각류의 주야 수평이동)

  • Suh Hae-Lip;Yu Ok-Hwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.29 no.4
    • /
    • pp.527-536
    • /
    • 1996
  • The patterns of diel horizontal migration (DHM) of 7 copepod species are compared as part of a general investigation of the zooplankton adaptations to the surf zone habitats. In a sandy shore surf zone of Yongil Bay, 3 sites such as the bottom and surface of 1 m water depth and water's edge are sampled with a sledge net(n=108). The surf zone copepod assemblage is dominated by 7 species; Acartia hudsonica, Fseudodiaptomus marinus, Paracalanus indicus, Calanus sinicus, Oithona similis, Sinocalanus tenellus and Labidocera bipinnata. Threefold variations in copepod abundance are observed within a diel cycle. Abundances of 7 dominant species and total copepods captured in the surface exhibit significant diel differences, but those taken in the bottom are not significantly affected by diel period. It is shown that about $90\%$ of the surf zone copepods performed DHM. The nocturnal high densities of copepods occurred for a neap tide when the offshore winds prevailed, suggesting the animals' ability for horizontal orientation and an active locomotion without invoking passive transportation by currents. Photoreactive behavior of copepods triggered by relative changes in light intensity may be a primary factor inducing DHM by aggregating in the surf zone during the night and spreading out at day; then copepods may reduce encounters with visual predators. In A. hudsonica, ontogenetic variations in timings of DHM are evident. Such variations are likely to minimize intraspecific competition for diets. Data on shoreward migration of copepods indicate that A. hudsonica, P. indicus, O. similis and S. tenellus can maintain swimming velocities of about $20m\;h^{-1}$ for durations of more than an hour. Our observations of strong diel difference in abundances point out the need for both day and night samplings in surf zone habitats, if the importance of these habitats to planktonic copepods are to be fully understood.

  • PDF

Study on the Various Size Dependence of Ionization Chamber in IMRT Measurement to Improve Dose-accuracy (세기조절 방사선치료(IMRT)의 환자 정도관리에서 다양한 이온전리함 볼륨이 정확도에 미치는 영향)

  • Kim, Sun-Young;Lee, Doo-Hyun;Cho, Jung-Keun;Jung, Do-Hyeung;Kim, Ho-Sick;Choi, Gye-Sook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.1
    • /
    • pp.1-5
    • /
    • 2006
  • Purpose: IMRT quality assurance(Q.A) is consist of the absolute dosimetry using ionization chamber and relative dosimetry using the film. We have in general used 0.015 cc ionization chamber, because small size and measure the point dose. But this ionization chamber is too small to give an accurate measurement value. In this study, we have examined the degree of calculated to measured dose difference in intensity modulated radiotherapy(IMRT) based on the observed/expected ratio using various kinds of ion chambers, which were used for absolute dosimetry. Materials and Methods: we peformed the 6 cases of IMRT sliding-window method for head and neck cases. Radiation was delivered by using a Clinac 21EX unit(Varian, USA) generating a 6 MV x-ray beam, which is equipped with an integrated multileaf collimator. The dose rate for IMRT treatment is set to 300 MU/min. The ion chamber was located 5cm below the surface of phantom giving 100cm as a source-axis distance(SAD). The various types of ion chambers were used including 0.015cc(pin point type 31014, PTW. Germany), 0.125 cc(micro type 31002, PTW, Germany) and 0.6 cc(famer type 30002, PTW, Germany). The measurement point was carefully chosen to be located at low-gradient area. Results: The experimental results show that the average differences between plan value and measured value are ${\pm}0.91%$ for 0.015 cc pin point chamber, ${\pm}0.52%$ for 0.125 cc micro type chamber and ${\pm}0.76%$ for farmer type 0.6cc chamber. The 0.125 cc micro type chamber is appropriate size for dose measure in IMRT. Conclusion: IMRT Q.A is the important procedure. Based on the various types of ion chamber measurements, we have demonstrated that the dose discrepancy between calculated dose distribution and measured dose distribution for IMRT plans is dependent on the size of ion chambers. The reason is small size ionization chamber have the high signal-to-noise ratio and big size ionization chamber is not located accurate measurement point. Therefore our results suggest the 0.125 cc farmer type chamber is appropriate size for dose measure in IMRT.

  • PDF

Evaluation of Setup Error Correction for Patients Using On Board Imager in Image Guided Radiation Therapy (Image Guided Radiation Therapy (IGRT) 시 On Board Imager를 이용한 환자 Setup Error 보정평가)

  • Kang, Soo-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.2
    • /
    • pp.69-81
    • /
    • 2008
  • Purpose: To reduce side effects in image guided radiation therapy (IGRT) and to improve the quality of life of patients, also to meet accurate SETUP condition for patients, the various SETUP correction conditions were compared and evaluated by using on board imager (OBI) during the SETUP. Materials and Methods: Each 30 cases of the head, the neck, the chest, the belly, and the pelvis in 150 cases of IGRT patients was corrected after confirmation by using OBI at every 2∼3 day. Also, the difference of the SETUP through the skin-marker and the anatomic SETUP through the OBI was evaluated. Results: General SETUP errors (Transverse, Coronal, Sagittal) through the OBI at original SETUP position were Head & Neck: 1.3 mm, Brain: 2 mm, Chest: 3 mm, Abdoman: 3.7 mm, Pelvis: 4 mm. The patients with more that 3 mm in the error range were observed in the correction devices and the patient motions by confirming in treatment room. Moreover, in the case of female patients, the result came from the position of hairs during the Head & Neck, Brain tumor. Therefore, after another SETUP in each cases of over 3 mm in the error range, the treatment was carried out. Mean error values of each parts estimated after the correction were 1 mm for the head, 1.2 mm for the neck, 2.5 mm for the chest, 2.5 mm for the belly, and 2.6 mm for the pelvis. Conclusion: The result showed the correction of SETUP for each treatment through OBI is extremely difficult because of the importance of SETUP in radiation treatment. However, by establishing the average standard of the patients from this research result, the better patient satisfaction and treatment results could be obtained.

  • PDF

The usefulness of the contrast agent high in gadolinium for the contrast-enhanced magnetic resonance hip arthrography (고관절의 자기공명관절조영검사 시 가돌리늄 함유량이 높은 조영제의 유용성)

  • Choi, Kwan-Woo;Kim, Yoon-Shin;Son, Soon-Yong;Lee, Ho-Beom;Na, Sa-Ra;Min, Jung-Whan;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.11
    • /
    • pp.5682-5688
    • /
    • 2013
  • The purpose of this study is to maximize diagnositc usefulness with increasing signal to noise ratio(SNR) and contrast to noise ratio(CNR) by using a 1mmol/mL gadolinium contrast agent. From January 2012 to June 2013 fourty-seven patients were underwent the MRI scanning to investigate the contrast difference in gadolinium content. Twenty of the patients were injencted the commercial contrast agent containing 0.5mmol/mL gadolinium and the rest of them were injected the new contrast agent containing 1mmol/mL gadolinium called gadobutrol. We measured and evaluated each SNR and CNR of the hip joint space, iliopsoas muscle and femoral head. As a result, using the 1mmol/mL gadolinium contrast agent had the higher SNR results than using the 0.5mmol/mL agent(27% in the hip joint, 30.01% in the femoral head). Also CNR using the 1mmol/mL gadolinium agent was proved to be higher than that of using 0.5mmol/mL agent(28.31% in the ilopsoas muscle and 26.74% in the femoral head). Therefore, the contrast agent containing more gadolinium like 1mmol/mL used in this study is more effective to shorten T1 relaxation time, so it increases the signal intensity and CNR and furthermore maximizes diagnostic value. This study reports the usefulness of the 1mmol/mL contrast agent in the contrast-enhanced magnetic resonance hip arthrography for the first. Therefore, it can be considered to have an meaningful academic value as showing the method for increasing the diagnostic usefulness by using the 1mmol/mL contrast agent.

17 beta-Estradiol Increases Peak of $\textrm{Ca}^{2+}$ Current in Mouse Early Embryo (에스트로겐이 생쥐 초기배의 $\textrm{Ca}^{2+}$ 전류에 미치는 영향)

  • 강다원;신용원;김은심;홍성근;한재희
    • Journal of Embryo Transfer
    • /
    • v.16 no.2
    • /
    • pp.79-89
    • /
    • 2001
  • Steroid hormones control the expression of many cellular regulators, and a role thor estrogen in mouse oocytes has been well documented. The preovulatory $E_2$increment is generally accepted as the endocrine process regulating induction of in vivo oocyte maturation To address whether the activity of the T-type $Ca^{2+}$ channel is altered by 17 beta-estradiol ( $E_2$), we examined the actions of $E_2$on the calcium channel of mouse oocytes and early embryos. Oocrtes were collected from the oviduct of mice treated with pregnant mare's serum gonadotropin (PMSG) and human choronic gonadotropin (hCG). Whole cell voltage clamp technique and confocal microscopy were used to examine that $E_2$increase intracellular $Ca^{2+}$ concentration ([C $a^{2+}$]$_{i}$ ) via voltage dependent $Ca^{2+}$ channel (VDC) and estrogen receptor (FSR), and $E_2$concentration by the use of radioimmunoassay (RIA) were examined in mouse. The results obtained were as follows: The peak of $Ca^{2+}$ current induced by $E_2$increased 122% to 1.50$\pm$0.03 nA from 1.23$\pm$0.21 nA (n=15) in the presence of 5 mM extracellular $Ca^{2+}$ concentration ([C $a^{2+}$]$_{o}$ ). The increased $Ca^{2+}$ current was temporally associated with $Ca^{2+}$ transients. The intracellular $Ca^{2+}$ level increased 207%~30 s following the addition of 1${\mu}{\textrm}{m}$ $E_2$(relative fluorescence intensity: 836.4$\pm$131.2 for control, n=10, 1736.4$\pm$192.0 in the presence of $E_2$, n=10). $E_2$increased amplitude of $Ca^{2+}$ current and [C $a^{2+}$]$_{i}$ . $E_2$-induced $Ca^{2+}$ current and $E_2$concentration in blood were showed difference on the stage of embryo. These results suggest that $E_2$modulate $Ca^{2+}$ channel to increase $Ca^{2+}$ influx.$Ca^{2+}$ influx.

  • PDF

Effect of MRI Media Contrast on PET/MRI (PET/MRI에 있어 MRI 조영제가 PET에 미치는 영향)

  • Kim, Jae Il;Kim, In Soo;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.19-25
    • /
    • 2014
  • Purpose: Integrated PET/MRI has been developed recently has become a lot of help to the point oncologic, neological, cardiological nuclear medicine. By using this PET/MRI, a ${\mu}-map$ is created some special MRI sequence which may be divided parts of the body for attenuation correction. However, because an MRI contrast agent is necessary in order to obtain an more MRI information, we will evaluate to see an effect of SUV on PET image that corrected attenuation by MRI with contrast agent. Materials and Methods: As PET/MRI machine, Biograph mMR (Siemens, Germany) was used. For phantom test, 1mCi $^{18}F-FDG$ was injected in cylinderical uniformity phantom, and then acquire PET data about 10 minutes with VIBE-DIXON, UTE MRI sequence image for attenuation correction. T1 weighted contrast media, 4 cc DOTAREM (GUERBET, FRANCE) was injected in a same phatnom, and then PET data, MRI data were acquired by same methodes. Using this PET, non-contrast MRI and contrast MRI, it was reconstructed attenuation correction PET image, in which we evanuated the difference of SUVs. Additionally, for let a high desity of contrast media, 500 cc 2 plastic bottles were used. We injected $^{18}F-FDG$ with 5 cc DOTAREM in first bottle. At second bottle, only $^{18}F-FDG$ was injected. and then we evaluated a SUVs reconstructed by same methods. For clinical patient study, rectal caner-pancreas cancer patients were selected. we evaluated SUVs of PET image corrected attenuastion by contrast weighted MRI and non-contrast MRI. Results: For a phantom study, although VIBE DIXON MRI signal with contrast media is 433% higher than non-contrast media MRI, the signals intensity of ${\mu}-map$, attenuation corrected PET are same together. In case of high contrast media density, image distortion is appeared on ${\mu}-map$ and PET images. For clinical a patient study, VIBE DIXON MRI signal on lesion portion is increased in 495% by using DOTAREM. But there are no significant differences at ${\mu}-map$, non AC PET, AC-PET image whether using contrast media or not. In case of whole body PET/MRI study, %diff between contras and non contrast MRAC at lung, liver, renal cortex, femoral head, myocardium, bladder, muscle are -4.32%, -2.48%, -8.05%, -3.14%, 2.30%, 1.53%, 6.49% at each other. Conclusion: In integrated PET/MRI, a segmentation ${\mu}-map$ method is used for correcting attenuation of PET signal. although MRI signal for attenuation correciton change by using contrast media, ${\mu}-map$ will not change, and then MRAC PET signal will not change too. Therefore, MRI contrast media dose not affect for attenuation correction PET. As well, not only When we make a flow of PET/MRI protocol, order of PET and MRI sequence dose not matter, but It's possible to compare PET images before and after contrast agent injection.

  • PDF

Electronic Sensors and Multivariate Approaches for Taste and Odor in Korean Soups and Stews (전자센서와 다변량 분석을 이용한 국내 국·탕류의 향미 특성 분석)

  • Boo, Chang Guk;Hong, Seong Jun;Cho, Jin-Ju;Shin, Eui-Cheol
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.5
    • /
    • pp.430-437
    • /
    • 2020
  • This is an approach study on the sensory properties (taste and odor) of 15 types of Korean conventional soups and stews using electronic nose and tongue. The relative sensor intensity for the taste components of the samples using electronic tongue was demonstrated. By SRS (sourness) sensor, sogogi-baechuguk (beef and cabbage soup) had the highest rate of 9.0. The STS (saltiness) sensor showed the highest score of 8.2 for ojingeoguk (squid soup). For the UMS (umami) sensor, which identifies savoriness, the sogogi-baechuguk was the highest at 10.1. The SWS (sweetness) sensors showed relatively little difference, with sigeumchi-doenjangguk (spinach and bean paste soup) at the highest of 7.3. According to the BRS sensor, which tests for bitterness, the siraegi-doenjangguk (dried radish green and bean paste soup) was the highest at 7.8. By principal component analysis (PCA), we observed variances of 56.21% in principal component 1 (PC1) and 25.23% in PC2. For each flavor component, we observed -0.95 and -0.20 for factor loading of PC1 and PC2 for SRS sensors, 0.96 and 0.14 for STS sensors, and -0.94 and 0.22 for PC1 and PC2 for UMS sensors, and PC1 and 0.22 for PC1 and PC2 loading for SWS sensors. The similarity between the samples identified by clustering analysis was largely identified by 4 clusters. A total of 25 kinds of volatile compounds in 15 samples were identified, and the ones showing the highest relative content in all samples were identified as ethanol and 2-methylthiophhene. The main ingredient analysis confirmed variances of 28.54% in PC1 and 20.80% in PC2 as a result of the pattern for volatile compounds in 15 samples. In the cluster analysis, it was found to be largely classified into 3 clusters. The data in this study can be used for a sensory property database of conventional Korean soups and stews using electronic sensors.

Physicochemical Properties of Powdered Green Teas in Korea (국내 시판 가루녹차의 이화학적 품질특성)

  • Lee, Lan-Sook;Park, Jong-Dae;Cha, Hwan-Soo;Lee, You-Min;Park, Jae-Woong;Kim, Sang-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.1
    • /
    • pp.33-38
    • /
    • 2010
  • This study was conducted to compare the physicochemical properties of powdered green teas produced in Korea and Japan including particle size, color, chlorophyll, caffeine and theanine. The average particle size of Korean powered green tea ($14.63-25.39\;{\mu}m$) was similar to that of Japanese powdered green tea ($15.46-21.02\;{\mu}m$). The surface color of shade-cultivated Haenam Green Tea (HN-1) had the highest negative 'a' value, which represents 'green' color. When the TCD (total color difference value) was measured in the samples, HN-1 was most similar to the premium powdered green tea of Japan (JA-1). Domestic shade-cultivated powdered green teas had 1.5-2 times greater chlorophyll content than powdered green teas produced from plants that were not cultivated in the shade. The presence of chlorophyll a resulted in a higher intensity of green color than the presence of chlorophyll b. A significant negative correlation was also observed between the color and the chlorophyll a, chlorophyll b and total chlorophyll contents. Specifically, chlorophyll a had the greatest impact on the green color of powdered green tea. The content of catechins, caffeine and theanine in Korean powdered green teas ranged from 14.679-20.128, 1.496-3.237 and 0.926-1.977 g/100 g, respectively. The caffeine and theanine contents were high in shade-cultivated powdered green teas. Based on the above results, domestic powdered green teas cultivated under shaded conditions had a quality similar to that of medium-quality green teas produced in Japan, and the overall quality of Korean powdered green tea was poorer than that of Japanese powdered green tea.