• 제목/요약/키워드: Intensity Difference

Search Result 1,921, Processing Time 0.03 seconds

Probeless Estimation of Electroluminescence Intensities Based on Photoluminescence Measurements of GaN-Based Light-Emitting Diodes

  • Kim, Jongseok;Jeong, Hoon;Choi, Won-Jin;Jung, Hyundon
    • Current Optics and Photonics
    • /
    • v.5 no.2
    • /
    • pp.173-179
    • /
    • 2021
  • The electroluminescence (EL) intensities of GaN-based light-emitting diodes (LEDs) are estimated based on their photoluminescence (PL) properties. The PL intensity obtained under open-circuit conditions is divided into two parts: the PL intensity under a forward bias lower than the optical turn-on voltage, and the difference between the PL intensities under open-circuit conditions and under forward bias. The luminescence induced by photoexcitation under a constant forward bias lower than the optical turn-on voltage is primarily the PL from the excited area of the LED. In contrast the intensity difference, obtained by subtracting the PL intensity under the forward bias from that under open-circuit conditions, contains the EL induced by the photocarriers generated during photoexcitation. In addition, a reverse photocurrent is generated during photoexcitation under constant forward bias across the LED, and can be correlated with the PL-intensity difference. The relationship between the photocurrent and PL-intensity difference matches well the relationship between the injection current and EL intensity of LEDs. The ratio between the photocurrent generated under a bias and the short-circuit current is related to the ratio between the PL-intensity difference and the PL intensity under open-circuit conditions. A relational expression consisting of the ratios, short-circuit current, and PL under open-circuit conditions is proposed to estimate the EL intensity.

Intensity Characteristics of Korean Obstruents (한국어 장애음의 강도 특성)

  • Park Hansang
    • MALSORI
    • /
    • no.47
    • /
    • pp.73-84
    • /
    • 2003
  • This study investigates differences in intensity across the three different Korean obstruent types in terms of the RMS amplitude of both the entire section and the first 512 samples of the immediately following vowel in two positions. The results showed that for the utterance initial position the RMS amplitude of both the entire section and the first 512 samples of the vowel was greatest for fortis obstruents, intermediate for aspirated ones, and weakest for lenis ones, with a significant difference between each pair of them. For the intervocalic position, in contrast, the intensity of the entire vowel was greatest for fortis obstruents, intermediate for lenis ones, and weakest for aspirated ones, with no significant difference between the last two groups, whereas the intensity of the first 512 samples of the vowel was greatest for fortis obstruents, intermediate for lenis ones, and weakest for aspirated ones, with a significant difference between each pair of the three groups. This means that the intensity of the earlier part of the vowel functions as a discriminator of Korean obstruents. The positional difference is due to the different behavior of the lenis obstruents in the intervocalic position, such that the intensity build-up is already on its way with voice lead.

  • PDF

Improved Fluorometric Assay Method for Ribonuclease Activity

  • Lee, Jong-Soo;Choi, Jong-Soo
    • BMB Reports
    • /
    • v.30 no.4
    • /
    • pp.258-261
    • /
    • 1997
  • A simple quantitative assay method for ribonuclease activity has been developed. This method is based on the decrease of fluorescence intensity emitted by the ethidium bromide bound to RNA due to the degradation of RNA by ribonuclease. The substrate RNA was reacted with ribonuclease A and the fluorescence intensity was measured after the addition of ethidium bromide. The intensity difference was calculated using a blank reaction mixture containing no RNase. Whole cellular RNA substrate produced a significant error and was not suitable for this assay method possibly because of local microheterogeniety caused by high molecular weight rRNA. but satisfying results were obtained with tRNA substrate. The intensity difference increased linearly by raising enzyme concentration up to $2{\times}10^{-4}$ Kunitz Units of ribonuclease A. More refined and reliable results were obtained by use of initial reaction velocities which were calculated from the plots of intensity difference vs time. A linear relationship between initial velocities and enzyme concentrations was observed up to 0.01 Kunitz Units of enzyme.

  • PDF

The Comparison of Effect of MC Intensity in Pain and ROM in Delayed Onset Muscle Soreness (미세전류 자극 강도에 따른 지연성 근육통의 통증과 관절가동범위에 미치는 영향)

  • Kim, Seun-Deuck;Park, Hye-Mi;Jung, Hwa-Su
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.7 no.1
    • /
    • pp.1-6
    • /
    • 2009
  • Purpose : We investigated the effects of microcurrent(MC) electrical stimulation on each intensity($100{\mu}A,\;200{\mu}A,\;500{\mu}A$ - 30pps frequency was same) on delayed onset muscle soreness(DOMS). Methods : Subjects were assigned randomly divided into three groups of eight for three different treatment protocoals($100{\mu}A,\;200{\mu}A,\;500{\mu}A$-experimental groups). Twenty-four healthy males and females subjects were participated in this study. All subjects performed eccentric exercise of elbow flexor(biceps brachii) until exhausted. The measured items of elbow flexor muscle strength were Nicholas Manual Muscle Taster(NMMT). The measured items of elbow joint range of motion ROM) were Goniometer. The measured items of elbow flexor muscle pain were visual analogue scale(VAS). Treatment were applied at 30 minute exercise after and again at 24 hours and at 48 hours and at 72 hours after. Measurements were taken after treatment. Analysis of Results using repeated measures analysis of variance(ANOVA) and post hoc tests were as follows: two-way ANOVA with repeated measurement for muscle strength, flexion ROM, extension ROM and VAS. Results : This results showed eccentric exercise casused DOMS, DOMS response to eccentric exercise were reduces by microcurrent therapy. DOMS was significant decreased at $100{\mu}A,\;200{\mu}A,\;500{\mu}A$. Muscle strength was significant difference at all intensity. Elbow flexion ROM was significant difference at all intensity but elbow extension ROM was insignificant difference at all intensity. VAS score was significant difference at $100{\mu}A$ and $500{\mu}A$ but insignificant difference at $200{\mu}A$. All experimental groups showed insignificant difference with all intensity MENS. Conclusion : These findings indicate that microcurrent therapy is had effect on recovery from exercise induced muscle damage. In our's suggestion, microcurrent therapy is particularly more appropriate therapeutic modality.

Monitoring of Water Quality Parameters using Spectroscopic Characteristics of River Water - Ulsan Area (하천 분광특성을 이용한 수질항목 모니터링 연구 - 울산 지역)

  • Hur, Jin;Kim, Mi-Kyung;Shin, Jae-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.6
    • /
    • pp.863-871
    • /
    • 2007
  • Spectroscopic characteristics of river water from four major watersheds in the Ulsan area were measured to examine their potential for estimating water quality parameters. The total 176 river samples were collected from 44 sites of small streams within the watersheds during the year 2006. Spectroscopic characteristics investigated included protein-like fluorescence (FLF) intensity, fulvic-like fluorescence (FLF) intensity, terrestrial humic-like fluorescence (TLF) intensity, UV absorbance at 254 nm, and UV absorbance difference at 220 nm and 254 nm. Protein-like fluorescence intensity showed linear relationships with biochemical oxygen demand (BOD), chemical oxygen demand (COD), total phosphorous (TP) concentrations of the samples with the correlation of 0.784, 0.779, and 0.733, respectively. Due to the UV absorption characteristics of nitrate at 220 nm, UV absorbance difference at 220 nm and 254 nm was selected to represent total nitrogen (TN) concentration. Exclusion of some samples with PLF intensity higher than 5.0 improved the correlation between the UV absorbance difference and TN as demonstrated by the increase of the correlation coefficient from 0.392 to 0.784. Instead, for the samples with PLF intensity lower than 5.0, the highest correlation of TN was achieved with UV absorbance at 254 nm. The results suggest that PLF intensity could be used as the estimation index for BOD, COD, and TP concentration of river water, and as the primary screening index for the prediction of TN using UV absorbance difference. Some BOD-based water quality levels among the river water were statistically discriminated by the PLF intensity. Low p-values were obtained from the t-tests on the samples with the first level and the second level (p=0.0003) and the samples with the second and the third levels (p=0.0413). Our combined results demonstrated that the selected spectroscopic characteristics of river water could be utilized as a tool for on-site real-time monitoring and/or the primary estimation of water quality.

A Study on Speaker Identification by Difference Sum and Correlation Coefficient of Intensity Levels from Band-pass Filtered Sounds (대역별로 여과한 음성 강도의 차이값과 상관계수에 의한 화자확인 연구)

  • Yang, Byung-Gon
    • Speech Sciences
    • /
    • v.10 no.2
    • /
    • pp.249-258
    • /
    • 2003
  • This study attempted to examine a speaker identification method using difference sum and correlation coefficient determined from a pair of intensity level matrices of band-pass-filtered numeric sounds produced by ten female speakers of similar age and height. Subjects recorded three digit numbers at a quiet room at a sampling rate of 22 kHz on a personal computer. Collected data were band-pass-filtered at five different band ranges. Then, matrices of five intensity levels at 100 proportional time points were obtained. Pearson correlation coefficients and the sum of absolute intensity differences between a pair of given matrices were determined within and across the speakers. Results showed that very high correlation coefficient and small difference sum generally occurred within each speaker but some individual variation was also observed. Thus, the matrix pair with a higher coefficient and a smaller difference sum was averaged to form each individual's model. Comparison among the speakers yielded generally low coefficients and large differences, which suggests successful speaker identification, but among them there were a few cases with very high coefficients and small differences. Future studies will focus on finer band ranges and additional spectral parameters at some peak points of the intensity contour at a low frequency band.

  • PDF

A Study on the Optimal Exercise Intensity for the Fat Oxidation of Fat Women (비만여성의 지방연소를 위한 최적운동강도에 관한 연구)

  • Choi, Young-Deog;Oh, Kyung-Hwan;Lim, Jong-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.2
    • /
    • pp.1039-1045
    • /
    • 2001
  • The aim of this study is to show the results which we analyse the interrelation among the physiological variable elements. We survey thirty fat women who don't do exercise regularly and are thirties. in order to offer basic data for setting the optimal exercise intensity through the efficient fat oxidation. We use RAMP II protocol of the Ever Green Hospital. The results are followings: 1. When the optimal exercise intensity for fat oxidation is done, there's a meaningful relation among the fat oxidation, $O_2$ max, and respiratory change. 2. When the optimal exercise intensity for fat oxidation is done, there's no meaningful relation statistically in $O_2$ max, heart rate, respiratory change, and caloric rate. 3. When the optimal exercise intensity for fat oxidation is done, there's a meaningful difference among three groups in %$VO_2$ max. However, there's a meaningful difference between group C and group A. B, and there's no meaningful difference between group B and group A.

  • PDF

Studies on the Optimum Light Intensity for Growth of Panu ginseng (II) Study on the difference of the optimum light intensity for the growth of ginseng Plant accordingto the root age (인삼생육의 최적광량에 관한 연구 (제2보) 인삼생육에 대한 최적광량의 년생간 차이에 관하여)

  • 이종철;천성기
    • Journal of Ginseng Research
    • /
    • v.6 no.2
    • /
    • pp.149-153
    • /
    • 1982
  • To investigate the effect of light intensity on the growth of shoots and roots, water and chlorophyll contents in the ginseng leaf were determined at 5%, l0%, 20%, 30% light transmittance rate (LTR) with 1,2 and 4 year-old ginseng plants in the field. Stem length, size of the leaf, water and chlorophyll contents were decreased as the increase of the light intensity in all ages of ginseng plants. The degree of decrease was severe in the one year-old ginseng compared to that of 2, or 4 year-old ginseng, while there was no difference between the 2 and 4 year-old plants. Root weight per plant was highest at 5% LTR in the one year-old plants, while it was at 20% LTR in the 2 and 4 year-old plants. Generally, demand of light for the growth of one year-old ginseng was lower than those of 2 or 4 year-old plants there was no difference of it among the ginseng plants older than 2 years.

  • PDF

Signatures Verification by Using Nonlinear Quantization Histogram Based on Polar Coordinate of Multidimensional Adjacent Pixel Intensity Difference (다차원 인접화소 간 명암차의 극좌표 기반 비선형 양자화 히스토그램에 의한 서명인식)

  • Cho, Yong-Hyun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.26 no.5
    • /
    • pp.375-382
    • /
    • 2016
  • In this paper, we presents a signatures verification by using the nonlinear quantization histogram of polar coordinate based on multi-dimensional adjacent pixel intensity difference. The multi-dimensional adjacent pixel intensity difference is calculated from an intensity difference between a pair of pixels in a horizontal, vertical, diagonal, and opposite diagonal directions centering around the reference pixel. The polar coordinate is converted from the rectangular coordinate by making a pair of horizontal and vertical difference, and diagonal and opposite diagonal difference, respectively. The nonlinear quantization histogram is also calculated from nonuniformly quantizing the polar coordinate value by using the Lloyd algorithm, which is the recursive method. The polar coordinate histogram of 4-directional intensity difference is applied not only for more considering the corelation between pixels but also for reducing the calculation load by decreasing the number of histogram. The nonlinear quantization is also applied not only to still more reflect an attribute of intensity variations between pixels but also to obtain the low level histogram. The proposed method has been applied to verified 90(3 persons * 30 signatures/person) images of 256*256 pixels based on a matching measures of city-block, Euclidean, ordinal value, and normalized cross-correlation coefficient. The experimental results show that the proposed method has a superior to the linear quantization histogram, and Euclidean distance is also the optimal matching measure.

The Analysis of Cognitive Reaction Time to the Intensity of Auditory Stimuli in Older People (청각자극의 세기에 따른 노인의 인지 반응시간 분석)

  • Kim, Kyeong-Mi;Chang, Moon-Young;Hong, Eun-Kyoung
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.5 no.1
    • /
    • pp.31-40
    • /
    • 2007
  • Objective: The purpose of this study was to get the cognitive reaction time according to the intensity of auditory stimuli in older people and to differentiate the cognitive reaction time between older people and adults. Method: 49 subjects consisted of 32 older people and 17 adults. Cognitive reaction time was assessed with Simple Auditory Reaction of Foundation I in PSS CogReHab. Analysis of the data was done by using independent t-test. Results: The results were as follows: 1. There was a significant difference of the mean of cognitive reaction time to the intensity of auditory stimuli. 2. There was no significant difference from older people regardless of sexual distinction in mean of cognitive reaction time. However, there was a significant difference of the mean of cognitive reaction time in adults. 3. There was a significant difference between older people who got a job or not in 90 dB of auditory stimuli. 4. The mean of cognitive reaction time to the intensity of auditory stimuli in older people was slower than adults. There was a significant difference of the mean of cognitive reaction time between older people and adults in 70 dB of auditory stimuli. 5. The mean of cognitive reaction time to the intensity of auditory stimuli in older people did not have the significant difference in scholastic ability. Conclusions: The results of the study showed slowing of the cognitive reaction time in auditory stimuli to aging in older people. Therefore, applying silver industry and development of equipment for older people may maintain independent life.

  • PDF