Integrity Evaluation Model for a Straight Pipe with Local Wall Thinning Defect (직관 배관의 국부 감육결함에 대한 건전성 평가 모델)

  • Park Chi Yong;Kim Jin Weon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.29 no.5 s.236
    • /
    • pp.734-742
    • /
    • 2005
  • The present study proposes the integrity evaluation model for a straight pipe with local wall thinning defect, which reflects the characteristics of training shape and loading condition in the Piping of nuclear power plant. For this purpose, a series of finite element analyses are performed under various defect geometries and loading conditions, and real pipe experiment data performed previously is employed. The model includes the effect of thinning length as well as thinning depth and width, and also it considers the combined loading effect between internal pressure and bending moment. The proposed model has been validated using the results of finite element analysis and pipe experiment data. The results indicate that the proposed model provides more reliable predictions of pipe failure than the current existing model, in terms of accuracy, consistency, and conservativeness of results.

Design of a Mobile Robot System for Integrity Evaluation of Large Sized Industrial Facilities (대형 산업설비 안전성 진단용 이동로봇 시스템 설계)

  • Lee Ho-Gil;Ryuh Young-Sun;Son Woong-Hee;Jeong Hee-Don;Park Sangdeok
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.11 no.7
    • /
    • pp.595-601
    • /
    • 2005
  • A mobile robot system utilizing NDT (Non-Destructive Testing) method is designed and fabricated f3r automatic integrity evaluation of large sized industrial reservoirs and pipelines. The developed mobile robot can crawl over the outer surface of the industrial facilities even though the shape of the structures is various and unsymmetric. The robot detects defects such as pinholes, cracks and thickness reduction at the wall of the facilities using EMAT (Electro-Magnetic Acoustic Transducer). Image processing technology for weld line detection at the surface of the target and host programs including defect detecting algorithms are also developed. Automation of defect detection for these kinds of large facilities using mobile robots is helpful to prevent significant troubles of the structures without danger of human beings under harmful environment.

Evaluation of Structural Integrity in the Squirrel Cage of Traction Motor (견인전동기의 농형 구조 안전성 평가)

  • Hong, Dan-Bi;Cheong, Choon-Sahng
    • Proceedings of the KSME Conference
    • /
    • 2001.06a
    • /
    • pp.825-830
    • /
    • 2001
  • Many techniques have been developed to evaluate the structural integrity for the traction motor with squirrel cage. However, the former approaches are not appropriate to our problems and there is no reliable specification for evaluation of squirrel cage motor. In this study, an improved boundary condition and the criteria for evaluation are proposed. Using 3-dimensional solid element, finite element model is generated. The number of meshes can be reduced by considering the symmetry of geometry. Stress analyses are carried out for three types of traction motors.

  • PDF

Integrity Evaluation of Semi-Elliptical Crack Under Thermal Shock (열충격하에 있는 반타원균열에 대한 파괴건전성 평가)

  • 이강용;김종성;김건영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.12
    • /
    • pp.3136-3148
    • /
    • 1994
  • This paper proposed the method of fracture integrity evaluation for semi-elliptical crack. Plane strain fracture toughnesses are used to compare with the thermal shock stress intensity factors for semi-elliptical crack obtained by Vainshtok weight function method. The method is applied to the finite Cr Mo V and 2.25Cr Mo steel plates with semi-elliptical crack under the thermal shock. For the purpose, tensile property and fracture toughness with respect to the temperature are measured. To verify the method, thermal shock experiments are carried. The theoretical predictions are in good agreement with the experiments.

A Study on the Systematic Mechanical Integrity Evaluation Methods of Water-Cooled Generator Stator Windings (수냉각 발전기 고정자의 기계적 건전성 평가방법)

  • Bae, Yong-Chae;Kim, Hee-Soo;Lee, Wook-Ryun;Lee, Doo-Young;Choi, Hong-Il;Yeon, Se-Heum
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.3059-3066
    • /
    • 2008
  • It is reported that the life of generator stator windings is expected about 30 years and a leak and water absorption phenomena can be progressed by fatigue, vibration, and corrosion. The water-cooled generator stator windings which were operated over 15 years are over 20 units and the mechanical problems such as leak and water absorption were found in the generator stator windings. In this paper, the systematic mechanical integrity evaluation methods which are applied to the water-cooled generator stator windings within the country are introduced.

  • PDF

Integrity Evaluation of Bogie Frame by Ultrasonic Fractography Analysis (초음파 파면해석에 의한 대차 프레임의 건전성 평가)

  • 윤인식;권성태;선종성;명노종;정우현;손태순;김경국;김순철
    • Journal of the Korean Society for Railway
    • /
    • v.3 no.2
    • /
    • pp.77-83
    • /
    • 2000
  • This study proposes the integrity evaluation of the bogie frame using ultrasonic fractography analysis. Analysis objectives in this study are to investigate fracture planes of damaged zone by the A-scan method. The surface condition of fracture planes shows degree of degradation by the stress concentration. The detection of the natural defects in the bogie frame is performed using the characteristics of echodynamic pattern in ultrasonic signal. Results of ultrasonic testing agree fairly well with those of actual fracture plane. In quantitative fractography analysis, microstructures of actual fracture plane turned out to be intergranular and transgranular fracture. Proposed ultrasonic fractography analysis in this study can be used for the integrity evaluation of the bogie frame.

  • PDF

Evaluation of Dynamic Characteristics of the Box Beam of HANARO Reactor Pool (하나로 원자로 수조내 사각보의 동특성 평가)

  • Kim, Seong-Ho;Dan, Ho-Jin;Ryu, Jeong-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.525-525
    • /
    • 2005
  • This study is for the seismic analysis and the structural integrity evaluation of the box beam for supporting nuclear fuel-transfer-basket of the HANARO reactor pool. For performing the seismic analysis and evaluating the structural integrity in air or submerged condition, the finite element model of the fuel-transfer-basket and its supporting box beam(the coupled model) was developed. The hydrodynamic effect is also considered by using added mass concept. The seismic response spectrum analyses of the coupled model under the design floor response spectrum loads of Safe Shutdown Earthquake(SSE) were performed. Through the numerical experiments, the analysis results show that the stress values of the coupled model lot the structural integrity are within the ASME Code limits.

  • PDF

Development of a Piping Integrity Evaluation Simulator Based on the Hardware-in-the-Loop Simulation (하드웨어-인-더-루프 기반의 배관 평가 시뮬레이터의 개발)

  • Kim, Yeong-Jin;Heo, Nam-Su;Cha, Heon-Ju;Choe, Jae-Bung;Pyo, Chang-Ryul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.7
    • /
    • pp.1031-1038
    • /
    • 2001
  • In order to verify the analytical methods predicting failure behavior of cracked piping, full-scale pipe tests are crucial in nuclear power plant piping. For this reason, series of international test programs have been conducted. However, full-scale pipe tests require expensive testing equipment and long period of testing time. The objective of this paper is to develop a test system which can economically simulate the full-scale pipe test regarding the integrity evaluation. This system provides the failure behavior of cracked pipe by testing a wide-plate specimen. The system provides the failure behavior of cracked pipe by testing a wide-plate specimen. The system was developed for the integrity evaluation of nuclear piping based on the methodology of hardware-in-the-loop (HiL) simulation. Using this simulator, the piping integrity can be evaluated based on the elastic-plastic behavior of full-scale pipe, and the high cost full-scale pipe test may be replaced with this economical system.

Numerical Analysis of Hydrograph Determination for Cohesive Soil Levee (조립토 하천제방의 수위파형결정에 관한 수치해석적 연구)

  • Kim, Jin-Man;Kim, Ji-Sung;Oh, Eun-Ho;Cho, Won-Beom
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.4
    • /
    • pp.81-92
    • /
    • 2014
  • The integrity evaluation of river levee includes slope stability evaluation of riverside land and protected low-land, and safety of piping with respect to critical gradient and critical velocity based on related regulations, such as Design Criteria Rivers Commentary (2009), Structural Design Criteria Based Commentary (2009). The design hydro-graph is the most important design input factor for the integrity evaluation; it can be inaccurate due to the absence of its decision methods suggested by the national level. The authors in this paper evaluated numerical analytic levee integrity for piping and slope stability by changing each design hydro-graph, including rising ordinary water level, lasting flood water level, falling water level, and flood frequency for Mun-san-jae on Nak-dong River. Finally, the authors suggested that the levee integrity of piping and slope stability are very sensitive to the changes of increasing time of ordinary water level by 57 hours and lasting time of the flood water level by 53 hours, respectively, for Mun-san-jae.

An Evaluation of Structural Integrity and Fatigue Strength for the Bogie Frame of Monorail (모노레일 대차 프레임에 대한 구조 안전성 및 피로강도 평가)

  • Ko, Hee-Young;Shin, Kwang-Bok;Lee, Kwang-Seop;Lee, Eun-Gyu
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.5
    • /
    • pp.469-475
    • /
    • 2010
  • In this paper, the structural integrity and fatigue strength for the bogie frame of Monorail being developed in domestic was evaluated. Presently, the standard of evaluation for the bogie frame of monorail was not regulated. Therefore, the evaluation of the structural integrity and fatigue strength for the bogie frame was performed on the basis of the UIC 615-4 standard. The structural integrity of the designed bogie frame was evaluated by displacement and Von-Mises stress under each load conditions. And the fatigue strength was evaluated by combined main in-service load conditions specified at UIC 615-4 standard and it was compared with result of fatigue analysis using winLIFE v3.1 with the function of batch processing. The results shows that the structural integrity and fatigue strength of the designed bogie frame was satisfied, and the fatigue analysis using batch processing was more effective than conventional fatigue analysis using combined load conditions.