• 제목/요약/키워드: Integrated reactor

검색결과 257건 처리시간 0.024초

다차원 노심열수력 현상이 소듐고속로 고유안전성에 미치는 영향 (Impact of Multi-dimensional Core Thermal-hydraulics on Inherent Safety of Sodium-Cooled Fast Reactor)

  • 권영민;정해용;하귀석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3175-3180
    • /
    • 2008
  • A metal-fueled pool-type liquid metal fast reactor (LMFR) provides large margins to sodium boiling and fuel damage under accident conditions. The favorable passive safety results are obtained by both a reactivity feedback mechanism in the core and a passive decay heat removal system. Among the various reactivity feedbacks, the ones by a thermal expansion of a radial dimension of the core and by the control rod drivelines are strongly dependent on the flow conditions in the core and the hot pool, respectively. The effects of multidimensional thermal hydraulic characteristics on these reactivity feedbacks are investigated by the system-wide safety analysis code SSC-K with advanced thermal hydraulics models. Particularly a detailed three dimensional thermal hydraulics reactor core model is integrated into SSC-K for use in a whole system analysis of the passive safety aspects of LMR designs. The model provides fuel and cladding temperatures for every fuel pin in a reactor and coolant temperatures for every coolant sub-channel in the reactor.

  • PDF

Characteristics of the Integrated Steam Generators for a Liquid Metal Reactor

  • Sim Yoon Sub;Kim Eui Kwang
    • Nuclear Engineering and Technology
    • /
    • 제36권2호
    • /
    • pp.127-141
    • /
    • 2004
  • Various types of integrated steam generators, which integrate IHTS and a steam generator into a single unit of equipment for an LMR, were analyzed using an analytic solution with some simplification. The analysis showed that the undesirable reversed heat transfer, of which occurrence was previously observed only in an integrated single-region bundle type, can also occur in an integrated double-region bundle type. The mechanism of the reversed heat transfer occurrence in the double-region type is explained and it is shown the mechanism in the double-region type is completely different from that in the single-region type. Based on this finding, a method for preventing the aforementioned heat transfer is suggested. The performance of the four types of the integrated steam generators is assessed. For this assessment, a SG is actually designed for each type and the optimization in the geometric parameters and flow rate are optimized.

SP-100 우주선 원자로를 위한 고장진단 및 제어 통합 시스템 (A Fault Diagnosis and Control Integrated System for an SP-100 Space Reactor)

  • 나만균;양헌영;임동혁;이윤준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.231-232
    • /
    • 2007
  • In this paper, a fault diagnosis and control integrated system (FDCIS) was developed to control the thermoelectric (TE) power in the SP-100 space reactor. The objectives of the proposed model predictive control were to minimize both the difference between the predicted TE power and the desired power, and the variation of control drum angle that adjusts the control reactivity. Also, the objectives were subject to maximum and minimum control drum angle and maximum drum angle variation speed. A genetic algorithm was used to optimize the model predictive controller. The model predictive controller was integrated with a fault detection and diagnostics algorithm so that the controller can work properly even under input and output measurement faults. With the presence of faults, the control law was reconfigured using online estimates of the measurements. Simulation results of the proposed controller showed that the TE generator power level controlled by the proposed controller could track the target power level effectively even under measurement faults, satisfying all control constraints.

  • PDF

Development of a multi criteria decision analysis framework for the assessment of integrated waste management options for irradiated graphite

  • Abrahamsen-Mills, Liam;Wareing, Alan;Fowler, Linda;Jarvis, Richard;Norris, Simon;Banford, Anthony
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1224-1235
    • /
    • 2021
  • An integrated waste management approach for irradiated graphite was developed during the European Commission project 'Treatment and Disposal of Irradiated Graphite and other Carbonaceous Waste'. This included the identification of potential options for the management of irradiated graphite, taking account of storage, retrieval, treatment and disposal methods. This paper describes how these options can be assessed using multi-criteria decision analysis (MCDA) for a case study relating to a generic power reactor. Criteria have been defined to account for safety, environmental, economic and socio-political factors, including radiological impact, resource usage, economic costs and risks. The impact of each option against each criterion has been assessed using data from the project and the wider literature. A linear additive approach has been used to convert the calculated impacts to scores. To account for the relative importance of the criteria, example weightings were allocated. This application has shown that MCDA approaches can be used to support complex decisions regarding irradiated graphite management, accounting for a wide range of criteria. Use of this approach by individual countries or organisations will need to account for the specific options, scores, weightings and constraints that apply, based on their national strategies, regulatory requirements and public acceptability.

분리형 개질기를 이용한 고효율 일체형 개질기 개발에 관한 연구 (Research of High Efficiency Integrated Reforming System Using Separated Reforming System)

  • 박상현;김철민;손성효;장세진;김재동;방완근;이상용
    • 한국수소및신에너지학회논문집
    • /
    • 제29권1호
    • /
    • pp.11-18
    • /
    • 2018
  • A high efficiency integrated reforming system for improving the efficiency of the 5 kW PEMFC system used as the back up power of building was studied. The separated reforming system consisted of three parts - A steam reformer with two stage concentric circular shape, a heat exchanger type steam generator and a CO shift reactor. Temperature and steam carbon ratio (SCR) were control variables during operation. The operating conditions were optimized based on the thermal efficiency of the steam reformer as reformate gas composition changes at different temperature. In experiments, water was fully vaporized in the steam generator up to SCR 3.5 and the maximum thermal efficiency was achieved at the operating temperature around $700^{\circ}C$ in the steam reforming reactor. With the results of the separated reforming system research, we improved the shape of high efficiency integrated reformer. The performance evaluation of the integrated reformer was based on optimized operating conditions in SCR 3.5. As a result, the developed integrated reforming system maintained an efficiency of 76% and constant performance over 3,000 hours.

냉각재(冷却材) 상실사고시(喪失事故時) 1300 MWe 급(級) PWR원전(原電) 주제어실(主制御室)의 선량평가(線量評價) (A Control Room Dose Assessment for a 1300 MWe PWR Following a Loss of Coolant Accident)

  • 장시영;하정우
    • Journal of Radiation Protection and Research
    • /
    • 제14권1호
    • /
    • pp.34-45
    • /
    • 1989
  • 프랑스의 1300 MWe 급(級) 표준(標準) P'4형 PWR 원전(原電)의 일차냉각재상실사고(一次冷却材喪失事故)(LOCA)시(時) 원전(原電) 주제어가내(主制御家內) 운전원(運轉員)에 대한 고사선(故射線) 피습선량(被濕線量)을 계산하여 주제어실(主制御室)의 체류안전성(滯留安全性)을 평가(評價)하였다. 본(本) 평가(評價)에서 사용(使用)된 제가정(諸假定)은 프랑스의 표준안전성분석보고서(漂準安全性分析報告書)에 따랐다. 본(本) 평가(評價)를 위하여 LOCA 사고시(事故時) 원자로건물외(原子爐建物外)로 방출(放出)되는 방사핵종(放射核種)의 방사능(放射能), 주제어실(主制御室)에서의 체적인자(體積因子) 및 제어실내(制御室內) 운전원(運轉員)의 전신(全身) 및 갑상선(甲狀膳) 피폭선량(被爆線量)을 사고발생후(事故發生後) 30일까지 전산(電算)할 수 있는 간단한 전산(電算)프로그램, COREX를 개발(開發)하였다. 본(本) 연구(硏究)에서 얻어진 계산결과(計算結果)는 대체적으로 프랑스의 EDF(불란서 전력주식회사(電力株式會社) 에서 제안(提案)한 결과(結果)와 대체적으로 잘 일치(一致)하였으나, 전신외부피폭선량(全身外部被爆線量)의 값은 일부(一部) 체적인자(體積因子) 값의 차이로 인(因)하여 일부 편차(偏差)를 보였다.

  • PDF

System dynamics simulation of the thermal dynamic processes in nuclear power plants

  • El-Sefy, Mohamed;Ezzeldin, Mohamed;El-Dakhakhni, Wael;Wiebe, Lydell;Nagasaki, Shinya
    • Nuclear Engineering and Technology
    • /
    • 제51권6호
    • /
    • pp.1540-1553
    • /
    • 2019
  • A nuclear power plant (NPP) is a highly complex system-of-systems as manifested through its internal systems interdependence. The negative impact of such interdependence was demonstrated through the 2011 Fukushima Daiichi nuclear disaster. As such, there is a critical need for new strategies to overcome the limitations of current risk assessment techniques (e.g. the use of static event and fault tree schemes), particularly through simulation of the nonlinear dynamic feedback mechanisms between the different NPP systems/components. As the first and key step towards developing an integrated NPP dynamic probabilistic risk assessment platform that can account for such feedback mechanisms, the current study adopts a system dynamics simulation approach to model the thermal dynamic processes in: the reactor core; the secondary coolant system; and the pressurized water reactor. The reactor core and secondary coolant system parameters used to develop system dynamics models are based on those of the Palo Verde Nuclear Generating Station. These three system dynamics models are subsequently validated, using results from published work, under different system perturbations including the change in reactivity, the steam valve coefficient, the primary coolant flow, and others. Moving forward, the developed system dynamics models can be integrated with other interacting processes within a NPP to form the basis of a dynamic system-level (systemic) risk assessment tool.