• Title/Summary/Keyword: Integrated magnetic

Search Result 285, Processing Time 0.023 seconds

RF Integrated Electromagnetic-Noise Filters Incorporated with Nano-granular Co41Fe38AI13O8 Soft Magnetic Thin Films on Coplanar Transmission Line

  • Sohn, Jae-Cheon;Yamaguchi Masahiro;Lim, Sang-Ho;Han, Suk-Hee
    • Journal of Magnetics
    • /
    • v.10 no.4
    • /
    • pp.163-170
    • /
    • 2005
  • The RF integrated noise filters are fabricated by photolithography. The stack for the electromagnetic noise filters consists of the nano-granular ($Co_{41}Fe_{38}AI_{13}O_8$) soft magnetic film / $SiO_2$ / Cu transmission line / seed layer (Cu/Ti) / $SiO_2$-substrate. A good signal-attenuation feature along with a low signal-reflection feature is observed in the present filters. Especially in the noise filter incorporated with a $Co_{41}Fe_{38}AI_{13}O_8$ magnetic film with lateral dimensions of $2000{\mu}m$ wide, 15 mm long and $1{\mu}m$ thick, the maximum magnitude of signal attenuation reaches -55 dB, and the magnitude of signal reflection is below -10 dB in the overall frequency range. And this level of signal attenuation is much larger than that of a noise filter incorporated with a Fe magnetic film.

Magnetic beads separation using a multi-layered microfluidic channel (다층구조의 미세유체채널을 이용한 자성입자 분리)

  • Lee, Hye-Lyn;Song, Suk-Heung;Jung, Hyo-Il
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1685-1686
    • /
    • 2008
  • This paper presents the design and experiment results of a multi-layered microsystem for magnetic bead applications. The magneto-microfluidic device is designed for capable of separating magnetic beads. In the presence of the magnetic field, magnetic beads are attracted and moved to high gradient magnetic fields. A multi-layered microfluidic channel consists of top and bottom layers in order to separate magnetic beads in the vertical direction. Our channel is easily integrated magnetic cell sorter, especially on-chip microelectromagnet or permanent magnet device. Fast separation of magnetic beads in top and bottom channels can be used in high throughput screening to monitor the efficiency of blood and drug compounds.

  • PDF

Magnetic Force Analysis and Design Methodology of Magnetic Gear in the Magnetic Geared Motor (마그네틱 기어드 모터의 자석 기어 자기력 해석 및 설계)

  • Kwangsuk Jung
    • Journal of Institute of Convergence Technology
    • /
    • v.13 no.1
    • /
    • pp.7-12
    • /
    • 2023
  • The built-in motor with an integrated magnetic gear can realize high torque without a separate reduction device. In this paper, the main design parameters of the magnetic gear constituting the magnetic geared motor are derived and the sensitivity analysis results according to these design parameters are discussed. In particular, processing and assembly issues of modulators sandwiched between rotating bodies are discussed, and loss and magnetic force characteristics of various types of modulators are introduced. Since the modulator, which plays a key role in converting the torque of the magnetic gear, is desirable to have a separate form, it is inevitable to add a non-magnetic support to add torsional stiffness according to high-speed rotation, so the effect of this is also analyzed.

Correlation analysis of human urinary metabolites related to gender and obesity using NMR-based metabolic profiling

  • Kim, Ja-Han;Park, Jung-Dae;Park, Sung-Soo;Hwang, Geum-Sook
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.16 no.1
    • /
    • pp.46-66
    • /
    • 2012
  • Metabolomic studies using human urine have shown that human metabolism is altered by a variety of environmental, cultural, and physiological factors. Comprehensive information about normal human metabolite profiles is necessary for accurate clinical diagnosis of disease and for disease prevention and treatment. In this study, metabolite correlation analyses, using $^1H$ nuclear magnetic resonance (NMR) spectroscopy coupled with multivariate statistics, were performed on human urine to compare metabolic differences based on gender and/or obesity in healthy human subjects. First, we applied partial least squares discriminant analysis to the NMR spectral data set to verify the data's ability to discriminate by gender and obesity. Then, the differences in metabolite-metabolite correlation between male and female, and between normal and high body mass index (obese) subjects were investigated through pairwise correlations. Creatine and several metabolites, including isoleucine, trans-aconitate, and trimethylamine N-oxide (TMAO), exhibited different quantitative relationships depending on gender. Dimethylamine had a different correlation with glycine and TMAO, based on gender. The correlation of TMAO with amino acids was considerably lower in obese, compared to normal, subjects. We expect that the results will shed light on the metabolic pathways of healthy humans and will assist in the accurate diagnosis of human disease.

The Effects of Repetitive Transcranial Magnetic Stimulation Integrated Mirror Therapy on the Gait of Chronic Stroke Patients

  • Cha, Hyun-Gyu;Kim, Myoung-Kwon
    • Journal of Magnetics
    • /
    • v.20 no.2
    • /
    • pp.133-137
    • /
    • 2015
  • This study was conducted to determine the effects of repetitive transcranial magnetic stimulation (rTMS) integrated mirror therapy on the gait of post-stroke patients. Thirty patients who were six months post-stroke were assigned to either the experimental group (n = 15) or the control group (n = 15). Stroke patients in the experimental group underwent rTMS and mirror therapy for the lower limbs, while those in the control group underwent rTMS and sham therapy. Participants in both groups received therapy five days per week for four weeks. A significant difference in post-training gains for the single support phase, step length, stride length and velocity was observed between the experimental group and the control group (p < 0.05). The experimental group showed a significant increment in the single support phase, step length, stride length, swing phase, velocity, cadence, double support phase and step width as compared to pre-intervention (p < 0.05). The control group showed a significant increment in step length, velocity, cadence and step width compared to preintervention (p < 0.05). Further investigation of the availability and feasibility of rTMS integrated mirror therapy for post-stroke patients as a therapeutic approach for gait rehabilitation is warranted.

An integrated DNA barcode assay microdevice for rapid, highly sensitive and multiplex pathogen detection at the single-cell level

  • Jung, Jae Hwan;Cho, Min Kyung;Chung, So Yi;Seo, Tae Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.276-276
    • /
    • 2013
  • Here we report an integrated microdevice consisting of an efficient passive mixer, a magnetic separation chamber, and a capillary electrophoretic microchannel in which DNA barcode assay, target pathogen separation, and barcode DNA capillary electrophoretic analysis were performed sequentially within 30 min for multiplex pathogen detection at the single-cell level. The intestine-shaped serpentine 3D micromixer provides a high mixing rate to generate magnetic particle-pathogenic bacteria-DNA barcode labelled AuNP complexes quantitatively. After magnetic separation and purification of those complexes, the barcode DNA strands were released and analyzed by the microfluidic capillary electrophoresis within 5 min. The size of the barcode DNA strand was controlled depending on the target bacteria (Staphylococcus aureus, Escherichia coli O157:H7, and Salmonella typhimurium), and the different elution time of the barcode DNA peak in the electropherogram allows us to recognize the target pathogen with ease in the monoplex as well as in the multiplex analysis. In addition, the quantity of the DNA barcode strand (~104) per AuNP is enough to be observed in the laser-induced confocal fluorescence detector, thereby making single-cell analysis possible. This novel integrated microdevice enables us to perform rapid, sensitive, and multiplex pathogen detection with sample-in-answer-out capability to be applied for biosafety testing, environmental screening, and clinical trials.

  • PDF

Magnetic Sensor-Based Detection of Picoliter Volumes of Magnetic Nanoparticle Droplets in a Microfluidic Chip

  • Jeong, Ilgyo;Eu, Young-Jae;Kim, Kun Woo;Hu, XingHao;Sinha, Brajalal;Kim, CheolGi
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.302-307
    • /
    • 2012
  • We have designed, fabricated and tested an integrated microfluidic chip with a Planar Hall Effect (PHE) sensor. The sensor was constructed by sequentially sputtering Ta/NiFe/Cu/NiFe/IrMn/Ta onto glass. The microfluidic channel was fabricated with poly(dimethylsiloxane) (PDMS) using soft lithography. Magnetic nanoparticles suspended in hexadecane were used as ferrofluid, of which the saturation magnetisation was 3.4 emu/cc. Droplets of ferrofluid were generated in a T-junction of a microfluidic channel after hydrophilic modification of the PDMS. The size and interval of the droplets were regulated by pressure on the ferrofluid channel inlet. The PHE sensor detected the flowing droplets of ferrofluid, as expected from simulation results. The shape of the signal was dependent on both the distance of the magnetic droplet from the sensor and the droplet length. The sensor was able to detect a magnetic moment of $2{\times}10^{-10}$ emu at a distance of 10 ${\mu}m$. This study provides an enhanced understanding of the magnetic parameters of ferrofluid in a microfluidic channel using a PHE sensor and will be used for a sample inlet module inside of integrated magnetic lab-on-a-chip systems for the analysis of biomolecules.

The analysis of magnetic circuit for the Three-Level converter using IM(Integrated Magnetics) (IM(Integrated Magnetics) 방식을 이용한 Three-Level 컨버터의 자기회로 해석에 관한 연구)

  • Bae, Jin-Yong;Kim, Yong;Kwon, Soon-Do;Cho, Kyu-Man;Lee, Kyu-Hoon;Choi, Geun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.218-222
    • /
    • 2007
  • This paper present the Three-Level converter for high power application. In converter system, magnetic components are important devices used for energy storage, energy transfer, galvanic isolation and filtering. The proposed Three-Level converter is to reduce the number of magnetic components. The secondary rectification was discussed by a single core transformer winding. The result of the analysis are verified using 1kW prototype.

  • PDF

A Fully Integrated Thin-Film Inductor and Its Application to a DC-DC Converter

  • Park, Il-Yong;Kim, Sang-Gi;Koo, Jin-Gun;Roh, Tae-Moon;Lee, Dae-Woo;Yang, Yil-Suk;Kim, Jung-Dae
    • ETRI Journal
    • /
    • v.25 no.4
    • /
    • pp.270-273
    • /
    • 2003
  • This paper presents a simple process to integrate thin-film inductors with a bottom NiFe magnetic core. NiFe thin films with a thickness of 2 to 3${\mu}m$ were deposited by sputtering. A polyimide buffer layer and shadow mask were used to relax the stress of the NiFe films. The fabricated double spiral thin-film inductor showed an inductance of 0.49${\mu}H$ and a Q factor of 4.8 at 8 MHz. The DC-DC converter with the monolithically integrated thin-film inductor showed comparable performances to those with sandwiched magnetic layers. We simplified the integration process by eliminating the planarization process for the top magnetic core. The efficiency of the DC-DC converter with the monolithic thin-film inductor was 72% when the input voltage and output voltage were 3.5 V and 6 V, respectively, at an operating frequency of 8 MHz.

  • PDF

A New Soft Switching DC-to-DC Converter Employing Transformer-coupled inductor (인덕터 결합 변압기를 이용한 소프트 스위칭 하프브릿지 컨버터에 관한 연구)

  • Lee, Dal-Woo;Ahn, Tae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.126-128
    • /
    • 2007
  • This paper presents a new soft switching dc-to-dc converter that employs IM transformer. Detailed analysis and design considerations of the proposed circuits are presented. By applying the proposed magnetic integration procedure, new integrated magnetic circuits featuring low loss, simple structure are then developed to overcome the limitations of prior art. Consequently, the power loss and the size of the integrated magnetic device are greatly reduced. The operation and performance of the proposed converter are demonstrated with an experimental converter that delivers a 5V/5A output from a 48V input at the maximum efficiency of 90 %.

  • PDF