• 제목/요약/키워드: Intake Duct

검색결과 58건 처리시간 0.022초

스테레오 PIV를 이용한 워터젯 흡입덕트 내부의 난류유동측정 (Stereoscopic PIV Measurement on Turbulent Flows in a Waterjet Intake Duct)

  • 권성훈;윤상열;전호환;김경천
    • 대한기계학회논문집B
    • /
    • 제28권5호
    • /
    • pp.612-618
    • /
    • 2004
  • Stereoscopic PIV measurements were made in the wind tunnel with the actual size waterjet model. The main wind tunnel provides the vehicle velocity while the secondary wind tunnel adjusts the jet issuing velocity. Experiments were performed at the range of jet to vehicle velocity ratio (JVR), 3.75 to 8.0 and the Reynolds number of 220,000 based on the jet velocity and the hydraulic diameter of the waterjet intake duct. Wall pressure distributions were measured for various JVRs. Three dimensional velocity fields were obtained at the inlet and outlet of the intake duct. It is found that severe acceleration is occurred at the lip region while deceleration is noticeable at the ramp side. The detailed three dimensional velocity fields can be used as the accurate velocity input for the CFD simulation. It is interesting to note that there are many different types of vortices in the instantaneous velocity field. It can be considered that those vortices are generated by the corner of rectangular section of the intake and Gortler vortices due to the curved wall. However, typical secondary flow with a pair of counter rotating vortex pair is clearly seen in the ensemble averaged velocity field.

Sensitivity of Hot Film Flow Meter in Four Stroke Gasoline Engine

  • Lee, Gangyoung;Lee, Cha--Myung;Park, Simsoo;Youngjin Cho
    • Journal of Mechanical Science and Technology
    • /
    • 제18권2호
    • /
    • pp.286-293
    • /
    • 2004
  • The air fuel ratios of current gasoline engines are almost controlled by several air flow meters. When CVVT (Continuous Variable Valve Timing) is applied to a gasoline engine for higher engine performance, the MAP (Manifold Absolute Pressure) sensor is difficult to follow the instantaneous air fuel ratio due to the valve timing effect. Therefore, a HFM (Hot Film Flow Meter) is widely used for measuring intake air flow in this case. However, the HFMs are incapable of indicating to reverse flow, the oscillation of intake air flow has an negative effect on the precision of the HFM. Consequently, the various duct configurations in front of the air flow sensor affect the precision of HFM sensitivity. This paper mainly focused on the analysis of the reverse flow, flow fluctuation in throttle upstream and the geometry of intake system which influence the HFM measurement.

흡기계의 동적효과가 기관성능에 미치는 영향 (The dynamic effects of intake system on the engine performance)

  • 조진호;김병수
    • 오토저널
    • /
    • 제9권3호
    • /
    • pp.85-93
    • /
    • 1987
  • The intake system of 4-cycle, 4-cylinder reciprocating engine is investigated the simple model composed of vessel, duct and throttling part. The numerical calculation based on the simulation is performed for the flow phenomena including heat transfer, friction and bend of duct at each part. In the multi-cylinder engine, the volumetric efficiency is increased a little as the junction location is closed to cylinder at the engine speed having maximum volumetric efficiency. The configuration and dimension of intake system have an influence on the inertia effect by resistance and pressure variation, and the magnitude of that is varied by the engine speed. Thus the volumetric efficiency is correlative to them. The volumetric efficiency is high as the intake valve close is advanced at the low engine speed, and is delayed at high speed.

  • PDF

물분사 추진기 관내 점성유동해석 (Viscous Flow Analysis of the Waterjet Duct)

  • 왕정용;전호환;박일룡;차상명
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 추계학술대회 논문집
    • /
    • pp.68-72
    • /
    • 2000
  • In the present paper, the numerical calculations for the viscous duct flow of water jet propulsion systems ship are carried out. The governing equation, incompressible Navier-Stokes equation, is discretized and analysed by a Method with the stcandard turbulence modeling. For the calculations the duct flow which h e intake flows disturbed by the ship, the results dcuhted by the potenti used Numerical results show fairly good agreement with the experimental data

  • PDF

입사각에 따른 반원형 입구형상 S-Shaped Intake에 대한 유동특성 연구 (A study on Flow Characteristics of the Semi-Circular inlet S-Shaped Intake at Various Angle of Incidence)

  • 이지형;조진수
    • 융복합기술연구소 논문집
    • /
    • 제5권2호
    • /
    • pp.27-32
    • /
    • 2015
  • Air intakes are an essential component of aircraft engines. They are mainly used to offer uniform airflows to engine faces. Fighter aircraft have to mask the engine face inside the fuselage in order to reduce the Radar Cross Section(RCS). Therefore, offset intakes like a S-Duct are one of promising components for this purpose. During a fight, it is unavoidable that the flow will enter the intakes at some face angles other than zero. In this case, the performance of the aircraft engine will be influenced to the angle of incidence. In this study, the CFD analysis of the semi-circular S-Duct with AR(0.5,0) is performed to investigate the influence of the angle of incidence on the performance of the S-Duct using a distortion coefficient. To consider the adverse pressure gradient, a $k-{\omega}$ SST turbulence model is employed. The secondary flow and flow separation are observed for all computational cases. It is found that the positive incidence angle produces the best performances.

자동차 흡기계 공기 여과기 필터의 음향학적 모델 (Acoustic modeling of an air cleaner filter in the engine intake system)

  • 이정권;강장훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.114-117
    • /
    • 2006
  • The air filter in engine intake system has a function of filtrating the dirt in the scavenging air as well as attenuating the noise. The noise attenuation within the air cleaner filter, however, has been regarded as negligible by the field engineers. In this paper, for the analysis of the acoustical performance of air filter, an acoustical model was suggested and the characteristics of air filter system were investigated. Fibrous structure of the filter element was modeled as a micro-perforated panel using the flow resistivity and porosity. The pleated geometry of the filter element was modeled as two coupled ducts that have permeable walls, in which each duct area was assumed being constant. Using such simplified geometry, a mathematical model was developed for the sound propagation within a narrow duct system. Visco-thermal effect was considered in modeling the sound propagation through such tubes; the filter box was modeled as a rigid rectangular box. By combining two models, a four-pole transfer matrix was derived. For the validation purpose, transmission loss was measured for a plastic rectangular box containing an air filter. A noticeable effect of the air filter element was observed by including the filter into the box. Comparing the predicted and measured data, we found that the predicted TL agrees well with experimental results, in particular, in magnitude and frequency at TL troughs.

  • PDF

흡기계 능동소음제어를 위한 적응형 필터 알고리즘의 개발 (Design of a New VSS-Adaptive Filter for a Potential Application of Active Noise Control to Intake System)

  • 김의열;김호욱;이상권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2009년도 추계학술대회 논문집
    • /
    • pp.231-239
    • /
    • 2009
  • The filtered-x LMS (FX-LMS) algorithm has been applied to the active noise control (ANC) system in an acoustic duct. This algorithm is designed based on the FIR (finite impulse response) filter, but it has a slow convergence problem because of a large number of zero coefficients. In order to improve the convergence performance, the step size of the LMS algorithm was modified from fixed to variable. However, this algorithm is still not suitable for the ANC system of a short acoustic duct since the reference signal is affected by the backward acoustic wave propagated from a secondary source. Therefore, the recursive filteredu LMS algorithm (FU-LMS) based on infinite impulse response (IIR) is developed by considering the backward acoustic propagation. This algorithm, unfortunately, generally has a stability problem. The stability problem was improved by using an error smoothing filter. In this paper, the recursive LMS algorithm with variable step size and smoothing error filter is designed. This recursive LMS algorithm, called FU-VSSLMS algorithm, uses an IIR filter. With fast convergence and good stability, this algorithm is suitable for the ANC system in a short acoustic duct such as the intake system of an automotive. This algorithm is applied to the ANC system of a short acoustic duct. The disturbance signals used as primary noise source are a sinusoidal signal embedded in white noise and the chirp signal of which the instantaneous frequency is variable. Test results demonstrate that the FU-VSSLMS algorithm has superior convergence performance to the FX-LMS algorithm and FX-LMS algorithm. It is successfully applied to the ANC system in a short duct.

  • PDF

흡기계 능동소음제어를 위한 적응형 필터 알고리즘의 개발 (Design of a New VSS-Adaptive Filter for a Potential Application of Active Noise Control to Intake System)

  • 김의열;김병현;김호욱;이상권
    • 한국소음진동공학회논문집
    • /
    • 제22권2호
    • /
    • pp.146-155
    • /
    • 2012
  • The filtered-x LMS(FX-LMS) algorithm has been applied to the active noise control(ANC) system in an acoustic duct. This algorithm is designed based on the FIR(finite impulse response) filter, but it has a slow convergence problem because of a large number of zero coefficients. In order to improve the convergence performance, the step size of the LMS algorithm was modified from fixed to variable. However, this algorithm is still not suitable for the ANC system of a short acoustic duct since the reference signal is affected by the backward acoustic wave propagated from a secondary source. Therefore, the recursive filtered-u LMS algorithm(FU-LMS) based on infinite impulse response(IIR) is developed by considering the backward acoustic propagation. This algorithm, unfortunately, generally has a stability problem. The stability problem was improved by using an error smoothing filter. In this paper, the recursive LMS algorithm with variable step size and smoothing error filter is designed. This recursive LMS algorithm, called FU-VSSLMS algorithm, uses an IIR filter. With fast convergence and good stability, this algorithm is suitable for the ANC system in a short acoustic duct such as the intake system of an automotive. This algorithm is applied to the ANC system of a short acoustic duct. The disturbance signals used as primary noise source are a sinusoidal signal embedded in white noise and the chirp signal of which the instantaneous frequency is variable. Test results demonstrate that the FU-VSSLMS algorithm has superior convergence performance to the FX-LMS algorithm and FX-LMS algorithm. It is successfully applied to the ANC system in a short duct.

무인기 S형 흡기구의 단면 형상에 따른 흡기구 성능 특성 (Intake Performance Characteristics according to S-duct Cross-section Shape in UAV)

  • 엄희옥;배지열;이남규;김지혁;남주영;조하나;조형희
    • 한국추진공학회지
    • /
    • 제23권5호
    • /
    • pp.107-114
    • /
    • 2019
  • 다양한 군용기에서, S자 형상의 디퓨저(흡입구)는 터보팬 엔진의 블레이드가 외부에 노출되는 것을 방지하기 위해 사용된다. 군용 항공기의 흡입구 형상은 F-22와 같은 직사각형, F-16과 같은 초승달모양, MG-25와 같은 타원형 등으로 다양하다. 본 연구에서는 수치해석을 통해 다양한 입구 형상을 갖는 S자 디퓨저의 공력 성능을 평가하였다. 또한, S형 덕트 중단부 단면 형상을 초승달 모양으로 변경하여 공력 성능에 미치는 영향을 분석하였다. 결과적으로, 공력 성능은 다양한 입구 모양에 따라 압력회복률에 약간의 차이를 보였다. 또한 압력왜곡은 직사각형 입구 형태에서 가장 낮았다. 중간단면의 형상이 타원형에서 초승달 모양으로 변경되었을 때, 전체 압력 회복은 높은 수준을 유지했다. 압력왜곡의 경우 초승달 형의 중간 단면을 갖는 덕트가 타원형 중간 단면 덕트보다 균일한 압력 분포를 나타내었다.