Surface Reforming of Engineering Plastic for adding nano-ATH (nano-ATH 첨가를 통한 엔지니어링 플라스틱의 표면개질)

  • Heo, Jun;Lee, Seung-Su;Jung, Eui-Hwan;Lim, Kee-Joe;Kang, Seong-Hwa
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.259-259
    • /
    • 2009
  • Surface contamination and leakage current have caused operating problems. A flashover in a substation may result in destruction of an insulator or many others electrical equipment. Engineering plastics have good characteristic (light weight, good productivity and little of void) as compare with epoxy or porcelain insulators. Outdoor insulator must have resistance to contamination. However, they are not suited to outdoor insulator by reason of being not good hydrophobic. RTV has a good property of hydrophobic and ATH has characteristic obstructing exothermic reaction. In order to reduce the incidence of insulator flashover and damage, the silicon rubber contained nano size ATH coat on surface of engineering plastics. In this paper, it compares resistance tracking of the engineering plastic coated RTV with that of non-coated engineering plastic and ATH filled composites performed much better than non-filled composites.

  • PDF

A Study on the Effect of Porous CaCO3 on Micro-cellular Plastics as an Additive for Nucleation (다공성 $CaCO_{3}$가 발포핵제로서 초미세 발포에 미치는 영향)

  • Lee, Dong-Wook;Cha, Sung-Woon;Yoon, Jae-Dong
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.991-996
    • /
    • 2004
  • Plastics are widely used in industry, because they are light, easily manufactured, and have high specific strength. And many researches to increase the strengths and to reduce the price are being conducted at now. One of these researches is concerning to additives. Foaming techniques are used to endow insulation properties, to improve specific strength, or reduce the material cost. Due to their unique properties, foamed plastics are applied to refrigerator, pipe, and insulators. Micro-cellular foaming is the latest foaming technique that was invented at 1980 in MIT. It is known that many tiny small cells are generated in the polymer matrices and micro-cellular foamed plastics show relatively high specific strength. We investigated the role of CaCO3 which is one of the most widely used additives in plastics industry as an additive for nucleation in view of cell morphology. CaCO3 used in this paper was treated to increase the dispersibility and to lower the density, so it has many pores at his body. Two experiments were conducted, in order to check the role of an additive for nucleation. One is compound-ability and the other one is role of nucleation agents.

  • PDF

A Study on th Applicatioin of Rubber Insulators for Noise and Vibration Control in Mortor Vehivel(I) (자동차 진동, 소음 저감을 위한 방진고무의 응용에 대하여(I))

  • 김중희;김기세
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.7 no.4
    • /
    • pp.41-48
    • /
    • 1985
  • 자동차 태수의 급격한 증가 및 일상생활에 있어서의 자동차 사용할 때간 증대는 곧 개개인의 생 활공간에 대한 자동차의 점유비율이 높아가고 있음을 입증한다. 따라서 거주성, 안락감, 쾌적성 등 종합적 주거환경에 관한 고객의 요구 역시 높은 수준으로 만족되어야 한다. 그러나 연비, 생 산성향상 등 경제적 측면의 요구에 부합하기 위한 자량의 경량화, 소형화 추세는 위에서 언급된 차내 주거환경을 저해하는 여러 가지 난제를 안겨주고 있다. 특히 안락감, 쾌적성의 저해는 가 장 직접적으로 나타나는 문제이며, 이는 차체의 진동입력에 대한 감수성 증대와 진동전달계류의 단서화에 따른 절연능력의 저하에 기인하는 것으로 보인다. 더구나 이와같은 진동문제는 대부분 차내소음을 유발시키며 넓은 주파수범위(홍80-120Hz)에 걸쳐 이들 두가지가 서로 달성되는 경우 가 많기 때문에 대적성의 저해요인으로 가장 크게 주목되고 있다. 자동차 진동 소음의 저감을 위한 노력은 실험적, 이론적 해석방법의 진보에 힘입어 꾸준한 소모로 실현되고 있으며 발생기구, 전달계류, 응답계류을 통틀어 부분적 또는 종체적인 연구가 계속되고 있다. 이와같은 세가지 계류중 전달계류은 발생기구와 응답계류 각각의 특성에 대하여 상호보완적인 역할을 수행해야 하기 때문에 항시 까다로운 요구조건을 안락시키도록 연구되어야 한다. 본고에서는 진동 소음의 전달계류중 가장 중요한 위치를 차지하고 있는 방진고무의 기본적역할 및 이들의 동력학적 측 면에서의 응용원리에 대해 검토하고 최근 급변하는 신기술동향에 대해 소개하고자 한다.

  • PDF

The Fire Hazard of Screwed Electric Contacts Due to Mechanical Vibration at Low Voltage Equipment

  • Choi, Chung-Seog;Kim, Young-Seok;Kim, Hyang-Kon
    • International Journal of Safety
    • /
    • v.4 no.2
    • /
    • pp.18-23
    • /
    • 2005
  • There are many electrical connections in the electric apparatus and most fires due to a fault contact result from a failure or misuse of electric apparatus and installation. The fault contact happens between electrical connections by the loose and the mechanical vibration. In this paper, we have investigated thermal and electrical properties of screwed electric contacts due to the mechanical vibration. The exciter was connected to a signal generator and power amplifier that provided the vibration frequency and amplitude. The vibration, temperature and voltage data were sent to a data acquisition system (DAQ). In the case that fault contact took place, the arc happened between the screwed electric contact and electric wire, heat due to the arc was transmitted to the adjacent insulators, for which the oxide could be generated more. In addition, a spark was generated and the insulator began to melt. Thus, the possibility of electrical fire became the highest in this case. Finally, when the fault contact takes place due to vibration, the hazard of an electric accident is very high.

A Study on Environmental Characteristic of Insulators for Ultra High Voltage Using ESDD and NSDD Measurement (초고압애자의 ESDD 및 NSDD 측정을 통한 내환경 특성 연구)

  • Lee, Sang-Yun;Lim, Yun-Seog;Lee, Won-Kyo;Lee, Dong-Il;Shin, Koo-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.2095_2096
    • /
    • 2009
  • 송배전용 설비에 사용되는 애자의 신뢰성은 전기적인 절연성질과 기계적인 내구성 뿐만 아니라 애자가 설치된 송전선로의 오손에 의한 내환경성에 의해서도 결정될 수 있다. 지금까지 염분 및 분진이 심한 지역에서 오손물이 애자에 미치는 영향에 대한 연구는 전기적, 기계적 신뢰성에 영향을 미치는 오손물질의 성분 분석 등을 통해 저압과 고압의 환경에서 진행되어 왔다.[1] 본 논문에서는 2003년부터 우리나라에서 운전해 오고 있는 765kV 애자오손 신뢰성 검토와 미국 전력연구원(EPRI)에서 수탁받은 765kV 고분자애자 특성연구의 일환으로, 765kV 상용선로에 사용되는 애자류에 대한 장기열화특성을 연구하기 위해 765kV 실증 시험설비를 구축하였다. 아울러, 765kV 애자 장기열화특성 분석을 위한 기초연구로 염분 및 분진 오손도를 측정하여 765kV 환경에서 애자종류에 따른 오손 특성을 검토하였다. 그 결과, RTV 실리콘고무 코팅 애자가 자기 및 유리재 애자에 비해 염분 오손도 면에서 비교적 우수한 특성을 지님을 확인 할 수 있었다.

  • PDF

Investigation of tracking resistance of engineering plastic and engineering plastic coated silicon rubber (엔지니어링 플라스틱과 실리콘 고무가 코팅된 엔지니어링 플라스틱의 내트래킹성 검토)

  • Heo, Jun;Jung, Eui-Hwan;Lim, Jong-Nam;Lim, Kee-Joe;Kang, Seong-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1449_1450
    • /
    • 2009
  • Surface contamination and leakage current have caused operating problems. A flashover in a substation may result in destruction of an insulator or many others electrical equipment. Engineering plastics have good characteristic (light weight, good productivity and little of void) as compare with epoxy or porcelain insulators. Outdoor insulator must have resistance to contamination. However, they are not suited to outdoor insulator by reason of being not good hydrophobic. RTV has a good property of hydrophobic and ATH has characteristic obstructing exothermic reaction. In order to reduce the incidence of insulator flashover and damage, the silicon rubber contained nano size ATH coat on surface of engineering plastics. In this paper, it compares resistance tracking of the engineering plastic coated RTV with that of non-coated engineering plastic and ATH filled composites performed much better than non-filled composites.

  • PDF

A research on the tunnel insulator pollution characteristic in Korea Railroad (철도 터널구간 애자류 오염도 분석에 관한 연구)

  • Jeon, Yong-Joo;Lee, Tea-Hoon;Choi, Kyoung-Il;Lee, Shi-Bin;Han, Sang-Gil
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1169_1170
    • /
    • 2009
  • This paper introduces insulator pollutant accumulate pattern in the tunnel of korea railroad. To accomplish this goal, effective sample collecting method was proposed for the first step. Dust at the surface was collected directly. Distilled water and brush was used while collecting. Through this method dust is easily and accurately collected. The second step is pollutant analysis. Several analyze item is selected such as quantity, conductivity, contact angle, Optical Microscope(OM), IR, Equivalent Salt Deposit Density(ESDD), and ICP-AES. The third step, best represent tunnel was selected considering location, length and natural surroundings. Also to consider the difference at inside the tunnel, several bracket insulators were selected along to the location. To make the result precise, above procedure was repeated several times at the same target. Finally relation among type of train, numbers of movement, surroundings, length will be considered in combination with the pollution. With this result pollute map for KORAIL could be accomplished and inspect period will be optimized case by case.

  • PDF

The Inner Defect Detection of Suspension Insulators by Lightning Impulse (뇌 임펄스를 이용한 현수애자의 내부결함 검출)

  • 송일근;곽희로
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.6
    • /
    • pp.83-90
    • /
    • 1995
  • This paper analyzed the electrical field strength of porcelain suspension insulator used various testing methods in order to present the causes and countermeasure for the puncture failure by the inner minute defect. A power frequency puncture test and a step-front-of-wave flashover voltage test were conducted. The failed specimen of these samples was analyzed material characteric observed the cross-sectional picture by the scanning electron microscope, and tested the autoclave expansion for the portland cement using the metal bond agent. The porcelain made a progress the failure by the thermal expansion coefficient of the different material. The inner detecting technique on behalf of the puncture failure protection is presented such as the steep-front-of-wave flashover voltage test.

  • PDF

Operating Process Design and Verification on the Oxidizer Filling Ground Facility for Liquid Rocket (액체로켓 산화제 지상공급시스템의 운용 프로세스 설계 및 검증)

  • Kim, Ji-Hoon;Park, Soon-Young;Park, Pyun-Goo;Yoo, Byung-Il
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.11a
    • /
    • pp.781-783
    • /
    • 2011
  • The oxidizer filling system, ground facility of the launch complex, should accept difficult requirements from the launcher sufficiently. The launcher do not have unnecessary insulators for mass reduction and manages liquid oxygen mass fastidiously to satisfy the mission requirement. So, the ground facility should be able to accept its requirements, then we should make the operating process being adjusted. In this paper, the operating process design and verification results on the oxidizer filling ground facility for liquid rocket is demonstrated.

  • PDF

A study on the effects of a conducting metallic barrier on the surface creepage flash over discharge (연면방전에 미치는 도전층의 영향에 관한 연구)

  • Sung Kae Chung
    • 전기의세계
    • /
    • v.17 no.3
    • /
    • pp.7-28
    • /
    • 1968
  • When a insulator plate is inserted to the discharge path of a space discharge gap in which the field strength is not uniform, the spark voltage under the atmospheric pressure between the electrodes decreases or rises according to the position of the insulating plate. Also it is reported that if a metallic barrier plate is inserted to the discharge path of the same space discharge gap, similar variations of spark voltage are found. Speaking briefly, mensioned above are the spark voltage characteristics when an insulator or metallic barrier is inserted to the space discharge gap. Also some experimental results, concerning to the surface creepage flash over characteristics at the case when an insulator barrier is inserted to the discharge path of a surface creepage discharge gap, were reported by Peek. But up to now there are no reports on surface flash over voltage characteristics at the case when a metallic barrier is inserted to the surface creepage gap. In this study the effects of a conducting metallic barrier inserted to the path of a surface creepage discharge gap on the flash over voltage characteristics are investigated theoretically and experimentally, and got some important results, clearing the effects of the position and width of a conducting barrier is inserted, the surface flash over voltage characteristics appear as an Inverse N or W Characteristics. Such theoretical or experimental results may have some relation not only with the effects of dry belt and snow on suspension insulators, but also with the effects of dirty zone or water drops on the surface creepage flash over voltage.

  • PDF