• Title/Summary/Keyword: Insulators

Search Result 652, Processing Time 0.028 seconds

Effects of annealing temperatures on the electrical properties of Metal-Ferroelectric-Insulator-Semiconductor(MFIS)structures with various insulators

  • Jeong, Shin-Woo;Kim, Kwi-Jung;Han, Dae-Hee;Jeon, Ho-Seoung;Im, Jong-Hyun;Park, Byung-Eun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.112-112
    • /
    • 2009
  • Temperature dependence of the ferroelectric properties of poly(vinylidefluoride-trifluoroethylene) copolymer thin films are studied with various insulators such as $SrTa_2O_6$ and $La_2O_3$. Thin films of poly(vinylidene fluoridetrifluoroethylene) 75/25 copolymer were prepared by chemical solution deposition on p-Si substrate. Capacitance-voltage (C-V) and current density (J-V) behavior of the Au/P(VDF-TrFE)/Insulator/p-Si structures were studied at ($150-200\;^{\circ}C$) and dielectric constant of the each insulators were measured to be about 15 at $850\;^{\circ}C$ for 10 minutes. Memory window width at 5 V bias the MFIS(metal-ferroelectric-insulator-semiconductor) structure with as deposited films was about 0.5 V at high temperature ($200\;^{\circ}C$). And the memory window width increased as voltage increased from 1 V to 5 V.

  • PDF

A Study on Selection of Cleaning Period and Pollution Analysis of Insulators in Tunnel (터널 애자류 오염도 분석과 세정주기 선정에 관한 연구)

  • Kim, Young-Seok;Shong, Kil-Mok;Choi, Myeong-Il
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.149-155
    • /
    • 2010
  • This paper was carried out to estimate pollution levels of various insulators in tunnel and establish cleaning period in each tunnel section. We estimate pollution level that is attached to insulators in environmental pollution area, industrial area, salt damage area. These results that the pollution quantity and conductivity were increased by pollution accumulation period. However, the conductivity showed each other big difference in each tunnel. In particular, the conductivity showed big in environmental pollution(tunnel A) and salt damage(tunnel C) area, It is considered to prevent accident that manage establishing periodic state of cleaning plan. Also, the Grease that spread on the insulator surface in existing is considered that it can prevent accident for long-term by restrain use.

Multi-Stress Aging Test Technology for Suspension Polymer Insulator (폴리머 현수애자의 복합가속열화 평가기술)

  • Park, Hoy-Yul;Kang, Dong-Pil;Kim, Ik-Soo;Shin, Young-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.481-484
    • /
    • 2003
  • Recently polymer insulators are being used for outdoor high voltage applications. Polymer insulators have significant advantages over porcelain and glass insulators. With the gradual improvement of their design and material, their reliability has also increased. It is however difficult to establish how they will perform after several years of service. Aging of the insulator weathershed may lead to damages such as excessive chalking and crazing, erosion and tracking which affect the insulator performance. In service insulator are subjected to aging stresses such as humidity, pollution and electrical field which act singly or in combination. There have been numerous accelerated laboratory tests developed with the intention of evaluating suitability of polymeric materials. Some of these are strictly material tests, where as, others evaluate full scale devices. Service experience plays a key role in the utility selection of polymer insulator, but is time consuming, and may not always be available. Hence there is a need for a meaningful and reliable accelerated aging test for polymer insulator. This paper describes multi-stress aging test for reliability of polymer insulator This paper presents the rule of multi-stress aging test and test chamber for polymer insulator in korea electrotechnology research institute.

  • PDF

Study on the Organic Gate Insulators Using VDP Method (VDP(Vapor Deposition Polymerization) 방법을 이용한 유기 게이트 절연막의 대한 연구)

  • Pyo, Sang-Woo;Shim, Jae-Hoon;Kim, Jung-Soo;Kim, Young-Kwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.185-190
    • /
    • 2003
  • In this paper, it was demonstrated that the organic thin film transistors were fabricated by the organic gate insulators with vapor deposition polymerization (VDP) processing. In order to form polyimide as a gate insulator, vapor deposition polymerization process was also introduced instead of spin-coating process, where polyimide film was co-deposited by high-vacuum thermal evaporation from 4,4'-oxydiphthalic anhydride (ODPA) and 4,4'-oxydianiline (ODA) and 2,2-bis(3,4-dicarboxyphenyl)hexafluoropropane dianhydride (6FDA) and ODA, and cured at $150^{\circ}C$ for 1hr. Electrical output characteristics in our organic thin film transistors using the staggered-inverted top-contact structure obtained to the saturated slop in the saturation region and the subthreshold non-linearity in the triode region. Field effect mobility, threshold voltage, and on-off current ratio in $0.45\;{\mu}m$ thick gate dielectric layer were about $0.17\;cm^2/Vs$, -7 V, and $10^6\;A/A$, respectively. Details on the explanation of compared to organic thin-film transistors (OTFTS) electrical characteristics of ODPA-ODA and 6FDA-ODA as gate insulators by fabricated thermal co-deposition method.

  • PDF

The Characteristic of Tracking Phenomena and Surface Discharge at the atmospheric Pressure (대기압하의 액체질소중 트래킹현상 및 연면방전 특성)

  • Park, Kwang-Seo;Sin, Dong-Hwa;Sin, Ho-Young;Ju, Jae-Hyun;Choi, Byoung-Ju;Lee, Kwang-Sik;Lee, Dong-In;Byon, Sung-Bong
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1699-1701
    • /
    • 1998
  • This paper was studied on the surface discharge characteristics on the solid insulators in the Liquid Nitrogen($LN_2$) at atmospheric pressure. Liquid Nitrogen has been widely used as a tooling and insulating materials for superconducting and cryogenic cable. Considering the effect of bubbles, we observed tracking Phenomena on the surface of solid insulators and investigated surface breakdown characteristics of several solid insulators.

  • PDF

Malfunction Detection of High Voltage Equipment Using Microphone Array and Infrared Thermal Imaging Camera (Microphone Array와 열화상 카메라를 이용한 고압설비 고장검출)

  • Han, Sun-Sin;Choi, Jae-Young;Lee, Jang-Myung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • The paper proposes a hierarchical fault detection method for the high voltage equipment using a microphone array which detects the location of fault and the thermal imaging and CCD cameras which verifies the fault and stores the image, respectively. There are partial arc discharges on the faulty insulators, which generates a specific pattern of sound. Detecting the signal using the microphone array, the location of the faulty insulator can be estimated. The 6th band-pass filter was applied to remove noise signal from wind or external influence. When the mobile robot carries the thermal and CCD cameras to the possible place of the fault insulator, the fault insulators or power transmission wires can be detected by the thermal images, which are caused by the aging or natural erosion. Finally, the CCD camera captures the image of the fault insulator for the record. The detection scheme of fault location using the microphone array and the thermal images have been proved to be effective through the real experiments. As a result of this research, it becomes possible to use a mobile robot with the integrated sensors to detect the fault insulators instead of a human being.

Leakage Current Waveforms and Spectrum Analysis of EPDM Polymer Insulator according to Environment Condition (환경조건에 따른 EPDM 고분자 애자의 누설전류파형과 스펙트럼 분석)

  • Park, Jae-Jun;Kim, Jeong-Boo;Song, Young-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.05b
    • /
    • pp.82-86
    • /
    • 2004
  • This research is about the result of leakage current waveform about the situation of surface leakage current and environmental changes(Salt fog, clean fog and rain) by EPDM polymer insulators' amount of salt. The researcher presents the result of changing about fundamental harmonic, 3rd harmonic and 5th harmonic from starting point of supplying power to flashover. In this study, researched environmental affects (clean fog, salt fog and rain) about surface aging of polymer insulators and used frequency spectrum of leakage current waveform to develop the diagnostic technique of surface aging. When amount of salt contents changed, surface aging stage and the degree of aging (distortion factor) about 3rd and 5th harmonic waveform on low frequency harmonic wave. The distortion factor which is harmonic percentage about basic harmonic is important pointer to evaluate the surface condition of polymer insulators.

  • PDF

Electrical Insulation Characteristics of Insulators in Cryogenic Liquid for a HTS Apparatus (고온초전도 기기를 위한 극저온 액체 중 절연물의 전기적 특성)

  • Baek, Seung-Myeong;Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Choi, Jae-Hyeong;Kim, Sang-Hyun;Kim, Hyun-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.263-264
    • /
    • 2006
  • For practical electrical insulation design of high temperature superconducting (HTS) power apparatuses, knowledge of the dielectric behavior of insulators in cryogenic liquid such as liquid nitrogen ($LN_2$) is essential. So in this paper, we discussed experimental investigations of breakdown and V-t characteristics of several insulators such as Kapton and glass fiber reinforced plastic (GFRP) that are candidates of insulator for HTS apparatus in cryogenic liquid. And we investigated the degradation of these insulation samples after breakdown with the microscope and SEM photograph. Moreover, survival and hazard analysis were performed.

  • PDF

Analysis on Solid Insulator Flashover Characteristics on Moisture Contamination for Electrical Insulation Improvement of ESS (ESS 안전성 개선을 위한 결로 운전 조건 고려 고체절연물 연면 절연파괴특성 분석)

  • Kim, Jin-Tae;Lee, Seung-Yong;Kim, Ji-young;Seok, Bok Yeol
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.2
    • /
    • pp.317-321
    • /
    • 2021
  • As the large-scale renewable energy power plant increases, the high-capacity and compact Energy Storage System (ESS) is required. However, this trend could reduce the insulation reliability of ESS. In this study, the surface flashover characteristics for four types of solid insulators are investigated in the uniform electric field with AC and Lightning Impulse (LI) voltage waveforms under various contamination levels. In addtion, insulator surfaces are compared based on the contact angle before and after surface flashover. The experimental results show that AC flashover voltage is dependent on the materials and the contamination level, but LI flashover voltage is only associated with the contamination level. Especially, AC flashover voltage of PC (PolyCarbonate) is higher than that of other insulators, which is associated with the unique and sequential creepage discharge propagation pattern of PC. The localized discharges on the surface of PC form corresponding tracking points. Then, the interconnected trackings result in the complete flashover. This flashover patterns degrade the surface of PC much more than that of epoxy and Bulk Molding Compoud (BMC). Thus, the contact angle of PC is significantly reduced compared to that of other insulators. The increased hydrophilicity in the surface of PC enhances the insulator surface conductivity.

Analysis on the Power Handling Capability of Ground Navigation Loran-C Transmitting Antenna (지상항법 로란-C 송신 안테나의 출력 처리 용량 분석)

  • Jang-Han Kim
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.17 no.5
    • /
    • pp.351-357
    • /
    • 2024
  • The power handling capacity of the Loran-C transmitting antenna for terrestrial navigation was analyzed in this paper. The power handling capacity of a shortened umbrella-type monopole antenna for terrestrial navigation is determined by the insulation voltages of the base and guy insulators used in the antenna in addition to the effective height of the antenna. In this paper, the insulation voltage of the base insulator according to the transmitting antenna power was derived, and in order to obtain the insulation voltages of the points where the antenna and the guy lines are connected, the antenna voltages for the antenna height were derived. By comparing with the insulation voltages of the insulators used, the power handling capacity of the antenna can be analyzed. As a result of comparative analysis of the insulation characteristics of the insulators used for the transmitter antenna, the guy line insulation voltages were approximately 69[kV]~128[kV] depending on the antenna output of 50[kW]~100[kW], so the method of using two guy insulators in series was appropriate, and the insulation voltages at the base of the antenna were 64.8[kV]~91.7[kV], so it was possible to have a power handling capacity that could operate the antenna output power from 50[kW] to 100[kW].