Partial Discharge Quality Measurement improvement of XLPE Cable of 154kV by new method of FSA (박 센서 배열에 따른 154kV XLPE 케이블의 부분방전 검출 특성 연구)

  • Shin, Dong-Hoon;Yang, Jong-Seok;Lwin, Kyaw-Soe;Lim, Jong-Cheon;Hwang, Doo-Hyun;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.11a
    • /
    • pp.158-159
    • /
    • 2006
  • The system measuring the Partial discharge(PD) is very essential to investigate the hazard defects in the insulation systems of the high voltage engineering. We included two parts in this discussion; The proposed method of Foil Sensor Array and the normally used method m the practice. Firstly, it will be shown the improved sensitivity of our proposed FSA sensor compare with the existing normal foil sensor. And then, the linearity of detecting sensitivities of various kinds of FSA sensors such as $2{\times}2$, $2{\times}4$, $3{\times}3$ etc. using in our experiments, was shown. From the obtained results, we can see that FSA sensor is more sensitivity than normal foil sensor and the linear increment property of FSA sensitivities.

  • PDF

A Study on Evaluation of the Building Energy Rating depending on the Thermal Performance of Balcony Window with Low-E glazing (로이유리 발코니 창호의 단열성능에 따른 공동주택 건축물 에너지효율등급 평가 연구)

  • Lee, Na-Eun;Ahn, Byung-Lip;Jang, Cheol-Yong;Leigh, Seung-Bok
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.58-63
    • /
    • 2012
  • As the exterior of building has been considered one of th important parts, the use of glass that is suitable to express various appearances gets raised. However, windows have 6~7times lower insulating performance than insulated walls. Lately, highly efficient windows are required as the needs for reduction of energy consumption come to the force. Therefore, Nowadays more people use cooling systems in summer, more the use of Low-E glazing is increasing. Because it is good to block Solar Radiant Energy which can cause much of heat loss while cooling system is working. This study measures U-value of the double Low-E glazing window and commonly used single Low-E glazing window. And then the effect of each window on the efficiency rating has been analyzed applying to the certification system of the building energy efficiency rating which has implemented.

Measurements of the floor impact sound level for floating screeds in apartment house (共同住宅 뜬바닥構造의 바닥 衝擊音레벨 測定)

  • Park, Byeong-Jeon;Shin, Young-Moo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.11 no.2
    • /
    • pp.38-49
    • /
    • 1992
  • The structure borne sound is one of the most important factor in building acoustics. Nevertheless, there is not yet sufficient knowledge to predict its behavior in preparing the acoustical design of a building. We are concerned with the concrete floating floor construction, which is one of the most promising ways to control floor impact sound. This study is to develop floating screeds isolated from the conventional concrete floor structures, to improve the concrete floor systems for the purpose of the good sound insulation performance which protects the propagation of the structure borne sound. Floor impact sound in many apartment house buildings and developed floating floors was measured, and we can save many floor impact sound data.

  • PDF

Architectural Design Elements for Hazard-Resistant and Reduction House (방재 및 감재주택을 위한 건축 계획 요소의 설정)

  • Kim, Hyeong-Eon
    • KIEAE Journal
    • /
    • v.16 no.6
    • /
    • pp.77-82
    • /
    • 2016
  • Purpose: Almost every research carried out in our country against the natural disaster is focused on the temporary facilities such as temporary housing, emergency shelter and as a result, it is very hard to find out researches on the ordinary houses which installed integrated systems of hazard-resistant against the natural disaster. Method: To conduct this research, categorizing process for design, structural, environmental and installation elements found in the Hazard-Resistant and Reduction House built for sale in Japan was performed. Result: In this study, several design concepts and subordinate items are recommended for hazard-resistant housing. First, design concept of 'Preparedness' which means security and access to the storage storing goods especially food & beverage for the emergencies is needed. The subordinate items consist of security of stocking space, diversified and circular storage system, and safety storage system. Second, design concept of 'Security' which means security of physical safety space and rapid recovery to returning to daily life against natural disaster is needed. The subordinate items consist of many items including not only structure and facilities but also architectural design method. And finally, design concept of 'Maintenance, Support and Return' which means minimizing the physical and psychological damages and support safety and physical conditions of the victims from the impact of the disaster to returning to daily life is needed. The subordinate items consist of high efficiency insulation/airtightness design, microclimate design, combination of photovoltaic system and storage battery, non-power appliance system against the power failure, storing system for drinking water, rainwater storing and utilization system.

A New Method for Elimination of Zero-Sequence Voltage in Dual Three-Level Inverter Fed Open-End Winding Induction Motors

  • Geng, Yi-Wen;Wei, Chen-Xi;Chen, Rui-Cheng;Wang, Liang;Xu, Jia-Bin;Hao, Shuang-Cheng
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.67-75
    • /
    • 2017
  • Due to the excessive zero-sequence voltage in dual three-level inverter fed open-end winding induction motor systems, zero-sequence circumfluence which is harmful to switching devices and insulation is then formed when operating in a single DC voltage source supplying mode. Traditionally, it is the mean value instead of instantaneous value of the zero-sequence voltage that is eliminated, through adjusting the durations of the operating vectors. A new strategy is proposed for zero-sequence voltage elimination, which utilizes unified voltage modulation and a decoupled SVPWM strategy to achieve two same-sized equivalent vectors for an angle of $120^{\circ}$, generated by two inverters independently. Both simulation and experimental results have verified its efficiency in the instantaneous value elimination of zero-sequence voltage.

A Study on Electric Field Dispersion Techniques of Epoxy-Nanocomposites for Application of High Voltage Power Apparatus (고전압 전력기기응용을 위한 에폭시-나노콤포지트의 전기장 분산기술연구)

  • Lee, Chang-Hoon;Kim, Hyo-Chul;Cho, Young-Haw;Kim, Hyun;Jo, Sung-Choe;Park, Jae-Jun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.97-97
    • /
    • 2010
  • A new electric application method was developed to prepare epoxy/organoclay nanocomposite for the electrical insulation in the AC electric fields and it could be also used in the field of various viscous polymer/organoclay systems. The applied AC electric field condition was as follows; (1) inter-electrode distance: 40 mm, (2) application voltage: 3-11 kV, (3) frequency: 60~1,000 Hz, and (4) application time: 0~60 min. To characterize the epoxy/clay nanocomposite, WAXS and TEM analyses were confirmed. In order to explain how the organic modifier affects the exfoliation phenomena, a mechanism of the oscillating collision of the quaternary ammonium head was proposed and the effects of the AC voltage and frequency and the organoclay content were studied.

  • PDF

A Study on FSA Application and Standardization for Partial Discharge Measurement of 154 kV XLPE Cable (154 kV XLPE 전력케이블의 부분방전 측정을 위한 FSA의 적용 및 표준화 연구)

  • Shin, Dong-Hoon;Lwin, Kyawsoe;Yang, Jong-Seok;Hwang, Doo-Hyun;Lim, Jong-Chun;Park, Noh-Joon;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.5
    • /
    • pp.462-466
    • /
    • 2007
  • The measuring system of the Partial discharge(PD) is very essential to investigate the hazard defects in the insulation systems of the high voltage engineering. We will discussed this research which has included two parts. The proposed method of Foil Sensor Array(FSA) and the normally used method in the practice. Firstly, it will be shown the improved sensitivity of a FSA sensor, which is our aim, compare with the existing normal foil sensor. And then, the linearity of detecting sensitivities of various kinds of FSA sensors was shown. According to our experiments, we can see that FSA sensor is more sensitivity than normal foil sensor and the linear increment property of FSA sensitivities.

Development of Global Insulation Assessment System for Medium Voltage power Cable System (배전용 전력케이블 시스템 포괄진단 설비 개발)

  • 이동영
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.2
    • /
    • pp.66-72
    • /
    • 2003
  • The global assessment system for medium voltage power cable systems has been developed The minimum purpose of diagnostic activity is the economic discrimination and maintenance of bad cables which is likely to cause cable system failure. I have adapted the Aging Time Constant Method to construct the power cable assessment system for the diagnostic purpose. From the field application test and breakdown test results, it could be concluded that the diagnostic system was successful art convenient for the discrimination and maintenance of the bad cables, which is likely to fail sooner or later, economically.

Study on the Analysis and the Application of State-of-the-Art Daylighting Design Cases - Based on the Case Studies of LEED(Leadership in Energy and Environmental Design) Multi-Family housing - (최신 자연채광 디자인 사례들 분석 및 그 적용에 관한 연구 - 미국 LEED 인증 공동주택 사례분석을 바탕으로 -)

  • Yoon, Hea-Kyung
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.1
    • /
    • pp.265-273
    • /
    • 2013
  • The purpose of this study is to analyze the state-of-the-art daylighting design among LEED(Leadership in Energy and Environmental Design) multi-family housing cases and to explore the feasibilities for their applications in domestic housing design. Occupants in multi-family houses are reported to consume more electricity power than those in single houses. That may imply the problems of daylighting design in domestic housing design for multi-family houses have better insulation system and less windows and outside walls than single houses. Therefore two systems, daylight delivery system and daylight control system, are scrutinized for daylighting design with LEED cases. The findings show when windows as a daylight delivery system are combined with overhangs, fins, louvers, fenestration materials, speciality fenestration, or interior controls as a daylight control system, the outcome goes with more energy savings and better facade design. Beside those, lightshelves as a daylight delivery system seem to have potentials in domestic multi-family houses with deep plans and less outside walls. Daylighting designs in domestic multi-family houses need to pursue available options more to achieve the integration of energy and aesthetics values.

A Study on the Electrical Physical Properties of Organic Thin Films for Manufacture in Power Device

  • Song, Jin-Won;Lee, Kyung-Sup
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.1
    • /
    • pp.18-21
    • /
    • 2005
  • Monolayers of lipids on a water surface have attracted much interest as models of biological membranes, but also as precursors of multilayer systems promising many technical applications. Until now, many methodologies have been developed in order to gain a better understanding of the relationship between the structure and function of the monolayers. Maxwell displacement current (MDC) measurement has been employed to study the dielectric property of Langmuirfilms. MDC flowing across monolayers is analyzed using a rod-like molecular model. A linear relationship between the monolayer compression speed a and the molecular area Am. Compression speed a was about 30, 40, and 50 mm/min. Langmuir-Blodgett(LB) layers of Arachidic acid deposited by LB method were deposited onto slide glass as Y-type film. The structure of manufactured device is Aul Arachidic acid! AI, the number of accumulated layers are $9{\sim}21$. Also, we then examined of the Metal-Insulator-Metal(MIM) device by means of I-V. The I-V characteristics of the device are measured from -3 to+3 V. The insulation property of a thin film is better as the distance between electrodes is larger.