• Title/Summary/Keyword: Insulation reinforcement

Search Result 48, Processing Time 0.019 seconds

Survey Research on Thermal Situation of Office Buildings (사무소 건축물의 단열상황에 관한 조사연구)

  • Jung, Ui In;Kim, Bong Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.3
    • /
    • pp.145-152
    • /
    • 2013
  • This study is to evaluate the thermal insulation of the curtain wall of the buildings constructed since the 1990s to the buildings currently under construction in 2011 and to provide the basic data for repairing and reinforcing and designing the thermal insulation. To this effect, the temperature difference by part was analyzed through measuring the inside and outside surface temperature of the curtain wall of the office building, and thereafter, the conditions of the thermal insulation and the thermal bridge part were examined. The result of the study is as follows; Not only in the winter season when the temperature difference between the indoor-outdoor is over $20^{\circ}C$, but also in the summer season when there is a small temperature difference, the temperature difference between the inside and outside of the frame is $2^{\circ}C{\sim}4^{\circ}C$ equally. Under such conditions as stated above, the thermal bridge occurred, which resulted from the heat flow of the steel frame part (mullion, transom), and therefore, the reinforcement of the thermal insulation is considered to be needed.

A Study on the Heat Transfer Phenomenon through the Glazing System (창호를 통한 열전달 현상에 관한 연구)

  • Kang, Eun-Yul;Oh, Myung-Won;Kim, Byung-Sean
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.32-37
    • /
    • 2009
  • An energy loss through the window system occupies about 10 to 30 percent on energy consumption of the whole building. That is the reason, several elements for a building composition of window system are the weakest from the heat. Insulation performance increases for the reducing heat loss. Heat transfer through the window system that is reducing heat transfer through conduction, convection and radiation. Insulation performance reinforcement methods classify improving heat specific quality of window system and improving efficiency of whole window system. The most application method among each methods is reducing emission ratio of the window system(Low-E glass), increasing a number of glazing(multiple window) and a method of vacuuming between glazing and glazing. Therefore this study is investigated a sort of glazing and specific character, U-value calculation with changing glazing thickness and calculation of temperature distribution and U-value with a glazing charging gas kind from double glazing. For a conclusion, an aspect of U-value figure at the smallest value case of vacuum glazing with Low-E coating. That means insulation efficiency is the best advantage during a building plan selecting vacuum glazing with Low-E coating for a energy saving aspect. In this way, U-value become different the number of glazing, coating whether or not and selecting injection gas. Therefore selecting of glazing is very important after due consideration by a characteristic and use of building and consideration of strong point and weak point.

  • PDF

Numerical analysis on the behaviour of reinforced concrete frame structures in fire

  • Dzolev, Igor M.;Cvetkovska, Meri J.;Ladinovic, Dorde Z.;Radonjanin, Vlastimir S.
    • Computers and Concrete
    • /
    • v.21 no.6
    • /
    • pp.637-647
    • /
    • 2018
  • Numerical approach using finite element method has been used to evaluate the behaviour of reinforced concrete frame structure subjected to fire. The structure is previously designed in accordance with Eurocode standards for the design of structures for earthquake resistance, for the ductility class M. Thermal and structural response are obtained using a commercially available software ANSYS. Temperature-dependent nonlinear thermal and mechanical properties are adopted according to Eurocode standards, with the application of constitutive model for the triaxial behaviour of concrete with a smeared crack approach. Discrete modelling of concrete and reinforcement has enabled monitoring of the behaviour at a global, as well as at a local level, providing information on the level of damage occurring during fire. Critical regions in frame structures are identified and assessed, based on temperatures, displacements, variations of internal forces magnitudes and achieved plastic deformations of main reinforcement bars. Parametric analyses are conducted for different fire scenarios and different types of concrete aggregate to determine their effect on global deformations of frame structures. According to analyses results, the three-dimensional finite element model can be used to evaluate the insulation and mechanical resistance criteria of reinforced concrete frame structures subjected to nominal fire curves.

Relationship of Ceramic Insulation Panel System Development and Verification of LCC

  • Han, Min-Cheol;Jeon, Kyu-Nam;Lee, Gun-Cheol;Kim, Tae-Hui
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.4
    • /
    • pp.386-392
    • /
    • 2012
  • In this study, life cycle cost (LCC) is analyzed according to insulation panel system type using a deterministic LCC analysis method. Through this analysis, it was found that the construction cost in the deterministic LCC analysis for Ceramic panels was low compared to the construction cost for metal and stone panels. Also, the difference in cost between the Ceramic panel and the metal panel was about 2 times. In the area of maintenance cost, it was found to be similar to the previously analyzed construction cost, in which the metal panel has the highest cost due to the high cost of construction and the frequent need for maintenance. In the case of the stone panel, a small difference in cost is shown compared with that of the Ceramic panel, but the cost is higher than the Ceramic panel. Regarding the cost of waste disposal, the Ceramic panel can reduce the cost by at least 1.5 times and up to 2 times compared to other panel systems. Finally, in the analysis of sensitivity according to changes in discount rates, the Ceramic panel and metal panel systems have a similar cost, and the cost of the metal panel is a bit larger than that of other panel systems. Thus, in the subjects used in the analysis, the Ceramic panel system shows the highest economic benefits.

Flexural Characteristics of Sheets Reinforced ALC Panel (시트 부착 ALC 패널의 휨강도 특성)

  • Lee, Dong-Weon;Kim, Jin-Man;Choi, Hong-Beom;Yu, Jae-Seong;Li, Kun-Mao;Sun, Joung-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.28-29
    • /
    • 2015
  • Although there are many applications with gypsum board because of its economical and construction advantages, four-layer construction technique, (hollow area between two-layer panel sets) is the general case to achieve the insulation, and resistance of horizontally applied force. Since this construction method has many problems such as complicate construction steps and increased cost, it is needed that the two-layer panel for improved construction and economical advantage for lightweight pane: thick panel with favorable performances. Therefore, in this research, based on the ALC panel with 10 to 30mm depth, feasibility of the paper reinforced panel as a lightweight wall material. As a result, favorable performance with increased flexural strength were achieved with paper reinforcement.

  • PDF

Upgrading flexural performance of prefabricated sandwich panels under vertical loading

  • Kabir, M.Z.;Rezaifar, O.;Rahbar, M.R.
    • Structural Engineering and Mechanics
    • /
    • v.26 no.3
    • /
    • pp.277-295
    • /
    • 2007
  • 3-D wall panels are used in construction of exterior and interior bearing and non-load bearing walls and floors of building of all types of construction. Fast construction, thermal insulation, reduced labor expense and weight saving are the most well pronounced advantage of such precast system. When the structural performance is concerned, the main disadvantage of 3D panel, when used as floor slab, is their brittleness in flexure. The current study focuses on upgrading ductility and load carrying capacity of 3D slabs in two different ways; using additional tension reinforcement, and inserting a longitudinal concentrated beam. The research is carried on both experimentally and numerically. The structural performance in terms of load carrying capacity and flexural ductility are discussed in details. The obtained results could give better understanding and design consideration of such prefabricated system.

Properties of Silicon-deposited Meta-aramid Fabrics by RF Magnetron Sputtering (RF 마그네트론 스퍼터링에 의해 실리콘이 증착된 메타아라미드 직물의 성질 분석)

  • Park, Jong Hyeon;Lee, Sun Young;Kim, Chun Su;Kang, Song Hee;Kim, Eui Hwa;Lee, Seung Goo
    • Textile Coloration and Finishing
    • /
    • v.29 no.1
    • /
    • pp.18-24
    • /
    • 2017
  • Meta-aramid fabric has been widely used as the reinforcement of composites due to its high flame resistance and tearing strength. Functionality such as abrasion resistance of fabric is very important for specialty fabrics used in car racing suits. In this study, to improve abrasion resistance property of meta-aramid fabric, silicon deposition was conducted by utilizing RF magnetron sputtering. The sputtering process parameters effects were investigated as sputtering power and substrate temperature. The obtained results suggest that the silicon deposition on the meta-aramid fabric has obvious effect upon increasing the abrasion resistance, the thermal insulation and the electric resistance condition for silicon deposition was established. In conclusion, the results of this study have made it possible to manufacture meta-aramids with higher abrasion strength.

(An) experimental study on the development of lightweight concrete using the PCM (PCM 혼입 경량기포콘크리트 패널 개발을 위한 기초적 연구)

  • Lim, Myung Kwan;Enkhbold, Odontuya;Kim, Young Ho;Choi, Dong Uk
    • KIEAE Journal
    • /
    • v.14 no.4
    • /
    • pp.133-138
    • /
    • 2014
  • The present study was carried out to assess the basic material properties and thermal behavior of light-weight foamed concrete panel mixed with PCM (Phase Changing Material). To do so, this study fabricated light-weight foamed concrete (1.0kg/m3) in pre-foaming method and mixed it with PCM micro capsule of 1-dodecanol and melamine to examine its physical and thermal properties. The results confirmed strength reinforcement effect by proper replacement ratio of fly-ash, which is an industrial by-product, and PCM. In addition, it found out that PCM-mixed light-weight foamed concrete had time delay and temperature reduction effect within the range of PCM phase transition according to the rise of outdoor temperature. It was also observed that the insulation performance of PCM-mixed light-weight foamed concrete was more dependent upon thickness than PCM replacement ratio.

Development of $20\;Nm^3$/hr Hydrogen Generator for Hydrogen Fueling Station (수소스테이션용 $20\;Nm^3$/hr급 수소제조장치 개발)

  • Oh, Young-Sam;Baek, Young-Soon
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.3
    • /
    • pp.263-271
    • /
    • 2006
  • In this study, $20\;Nm^3/hr$ scale compact hydrogen generator which can be apply to the hydrogen station was manufactured and tested. The design of $20\;Nm^3/hr$ scale compact hydrogen generator was upgraded on the base of $5\;Nm^3/hr$ scale plate hydrogen generator concept stacking the plate reactors. Ideas for improving system efficiency such as heat recovery from the exhaust, exhaust duct which is especially design for plate type reactor, reinforcement of insulation, enlargement of heat exchange area of reactor, introduction of desulphurizer reactor and PROX rector in a compact design etc. were applied. From the performance test, we can learn that the $20\;Nm^3/hr$ scale compact hydrogen generator can be operated steadily at 100% road condition and the methane conversion of over 94%(at S/C=3.75) was obtained. This result shows that the concept of plate type hydrogen generator can be scale-up to the $20\;Nm^3/hr$ scale and fit for hydrogen generator for on site hydrogen station application.

Insulation Reinforcement of the Electrical Power Cable Degradated by the Water Tree Using Silicon (실리콘을 이용한 수트리 열화된 전력 케이블의 절연 보강)

  • Kang, Hyeong-Gon;Park, Jun-Chae;Ko, Seok-Cheol;Lim, Sung-Hun;Lee, C.H.;Hanh, Y.B.;Han, B.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.468-471
    • /
    • 2003
  • Fault of under ground power cable occurs usually from the water tree such as the vented tree, the bow tree and the water-rich halo. The water tree penetrates to the polyethylene cable insulations. Sometimes, the water tree also diffuses to mother cable in the substation. In this paper, instead of replacement of the faulty cable, we tried to cure an electrical power cable degraded by the water trees with silicon injection method. And measured the results with the isothermal relaxation current analysis method. After cable cure, Chonil line was improved from 2.27 to 1.96 in a phase, from 2.148 to 2.020 in b phase, and from badness to 2.192 in c phase. And Keumam line was also improved from 2.419 to 1.920 in a phase, from 2.301 to 2.000 in b phase, and from badness to 1.957 in c phase.

  • PDF