• Title/Summary/Keyword: Insulation life

Search Result 285, Processing Time 0.032 seconds

Warm-up and Cool-down Characteristics of Cryogenic Insulation Materials in Liquid Nitrogen (액체질소에서의 극저온 절연매질의 Warm-up/Cool-down 특성)

  • Lee, Sang-Hwa;Shin, Woo-Ju;Khan, Umer Amir;Oh, Seok-Ho;Sung, Jae-Kyu;Lee, Bang-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.119-119
    • /
    • 2010
  • Among the various factors influencing the service life of the electric equipment, the performance of dielectric insulation materials has an important role to determine their whole service life. In order to determine the degradation of insulating materials immersed in extremely low temperature media such as liquid nitrogen, the abrupt temperature change from cryogenic to normal room temperature should be considered. But the assessments of low-temperature aging test method for the dielectric materials immersed in liquid nitrogen considering these conditions were not fully reported. Therefore, for the fundamental step to establish the suitable degradation test methods for cryogenic dielectric materials, we focused on the evaluation of ageing test methods for dielectric materials exposed to low temperature environments considering thermal shock by cool-down and warm up test.

  • PDF

Analysis of Adhesion Characteristics of Solid Propellants by Kind of Barrier Coat (접착 보조제 종류에 따른 고체 추진제 접착 특성 분석)

  • Jang, Myungwook;Koo, Myungjun;Yun, Jaeho;Lee, Dug Bum
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.4
    • /
    • pp.33-40
    • /
    • 2020
  • A sturdy on the adhesion properties of solid propellants, liners, and insulation was carried out according to the types of barrier coats. A barrier coats were used to prevent migration of the plasticizer or curative between the propellant/liner/insulation, and the barrier coat was selected out of Isocyanates with different molecular weight and number of -NCO in one molecule. As a result, it was found that the more the -NCO group and the larger molecular weight, the stronger adhesion. In addition, as a result of experiments about effects of the pot life after applying the barrier coat on bond strength, the adhesion strength was shown to increase as the pot life was short.

Assessment on Thermal Transmission Property of Wall Through a Scaled Model Test (축소모형 실험을 통한 벽체의 열관류 측정)

  • Chang, Yoon-Seong;Kim, Sejong;Shim, Kug-Bo;Lee, Sang-Joon;Han, Yeonjung;Park, Yonggun;Yeo, Hwanmyeong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.884-889
    • /
    • 2015
  • Appropriate evaluation of thermal insulation property of structural member and valid control of cooling/heating energy are important for improving building's energy efficiency. The typical heating system of house in Korea is the floor heating one. The radiation heating system is not only appropriate to climate and geographic conditions of Korea, but also advantageous to provide emotional comfort by the warm feeling of floor. Based on living conditions in Korea, scaled models of the wooden house and concrete house were designed. The ceiling was made of styrofoam insulation and the four sided walls and bottom were made of plywood and concrete, respectively. The floor was heated by heating film. Indoor vertical temperature distributions by floor heating system were measured by thermocouple, and surface temperatures on walls were measured by infrared thermography. Also, thermal insulation property of wooden wall was evaluated to build database for improving energy efficiency of wooden building. It is expected that collected data during tests of various types of floor and wall composition could be referenced for evaluating thermal environment of actual conditions of houses.

Evaluation of Thermal Insulation and Hypothermia for Development of Life Raft (해상 구명정의 단열성능평가 및 저체온증 예측 수치해석 연구)

  • Hwang, Se-Yun;Jang, Ho-Sang;Kim, Kyung-Woo;Lee, Jang-Hyun
    • Journal of Navigation and Port Research
    • /
    • v.39 no.6
    • /
    • pp.485-491
    • /
    • 2015
  • The technology review about risk of hypothermia of victim according to heat transfer characteristic of life raft and sea state can use accident correspondence of standing and sinking of ship. This study studied heat transfer characteristics required for the design of life raft and thermal insulation property analysis and evaluation methods. In addition, it is study for comprehend the risk of hypothermia and suggest analysis result that is experiment of thermal insulation property and body temperature property for decide of prediction the body temperature decline Thermal Analysis apply the finite element analysis method is comprehended the property of heat conductivity, convective effect of sea water and properties changes according to property of insulation material. it measure the heat flux with attach temperature sensor on body in order to comprehend the variation of body temperature with boarding a life raft experiment on a human body. This study validate results by comparing variation of temperature measured from experiment on a body with variation of temperature from finite element analysis model. Also, the criteria of hypothermia was discussed through result of finite element analysis.

A Study on the Development of Low-loss Type Hybrid Insulation Pole Transformers and (저손실형 복합절연 주상변압기 개발 및 단락특성에 관한 연구)

  • Min, Yun-Hong;You, Ho-Keun;Bae, Sun-Ki;Kim, Ho-Chul;Lee, Yun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.607-612
    • /
    • 2002
  • This paper presents the first domestic model product of hybrid Insulation low-loss type pole transformer, with increased overload ability, increased life, reduced loss, focusing improved short-circuit characteristics. The capacity of this transformer is 100 KVZ, rates first voltage 13200 V and secondary voltage 230/115 type. The volume of model transformer that was produced in high temperature using hybrid insulation can be reduced to 10-20% in comparison with that of present transformer with the same capacity. In this paper, we did short-circuit test and tested general characteristics of model transformer. In addition, we suggested design application new concept and methods thorough this experiment.

  • PDF

A Study on the Electrical Characteristics by Accelerating Degradation for Traction Motor in Urban Transit EMU (전동차용 견인전동기의 가속열화에 의한 전기적 특성 연구)

  • Park, H.J.;Kim, G.D.;Jang, D.U.;Choi, J.S.;Kim, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1235-1237
    • /
    • 2002
  • Insulation system(200 class} for stator coil is designed for traction motor with VVVF inverter. Sample coils for stator of the traction motor were tested by accelerative thermal degradation which composed of heat, vibration, moisture, and overvoltage apply. Reliability and expected life were evaluated on the insulation system for 200 class traction motor. After aging of 10 cycles, tan ${\delta}$ increased with voltage. This result is due to increase of internal defects and change of insulation structure.

  • PDF

A Study on Life Estimate of Insulation Cable for Image Processing of Electrical Tree (전기트리의 영상처리를 이용한 절연케이블의 수명예측에 관한 연구)

  • 정기봉;김형균;김창석;최창주;오무송;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.319-322
    • /
    • 2001
  • The proposed system was composed of pre-processor which was executing binary/high-pass filtering and post-processor which ranged from statistic data to prediction. In post-processor work, step one was filter process of image, step two was image recognition, and step three was destruction degree/time prediction. After these processing, we could predict image of the last destruction timestamp. This research was produced variation value according to growth of tree pattern. This result showed improved correction, when this research was applied image Processing. Pre-processing step of original image had good result binary work after high pass- filter execution. In the case of using partial discharge of the image, our research could predict the last destruction timestamp. By means of experimental data, this Prediction system was acquired ${\pm}$3.2% error range.

  • PDF

Problem considerations and expectations in applying vegetable oil to power transformer (식물성 절연유의 전력용 변압기 적용에 따른 문제점 고찰 및 전망)

  • Park, Hyun-Soo;Kim, Ji-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.184-186
    • /
    • 2009
  • In past, transformer connection study was concentrated on efficiency improvement and life time broadening. But environmental side began to become important recently. In existing, quick transaction of mineral oil used to insulation oil of transformer is possibility to be difficult and causes environmental pollution in case of was outpoured and there is worry of fire occurrence. Accordingly, nonflammable performance becomes many interest in excellent vegetable oil because ignition point is high than mineral oil and environment friendly material. But, vegetable oil is cooling of transformer and insulation problem of insulating paper for cause of insulation oil special quality. Therefore, in this paper, special quality of vegetable oil that there are being a lot of mineral oil and the latest interest examined about problem and consideration item to be solved to analyzed comparison and applies vegetable oil to transformer for electric power.

  • PDF

A Study on The Insulation Diagnostic and Life Evaluation for the Pumped Storage Generator/Motor (양수 발전 전동기 고정자 권선 절연진단 및 수명평가에 관한 연구)

  • Park, Jong-Jeong;Kim, Hee-Dong;Lee, Young-Jun;Ju, Young-Ho;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1717-1720
    • /
    • 1998
  • In pumped storage Generator-motor stator windings gradually deteriorates due to mechanist, thermal, electrical stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Since the degration of generator-motor is gradually occurred, regular inspection system is necessary to monitor degrading. The result of this diagnosis is a basic for the maintxnance of generator-motor.

  • PDF