HVDC 케이블 평가방법 연구 (Study on the Evaluation Methode of HVDC Cable)

  • 안용호;장태인;정길조;유희영;김정년;전승익;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.229-231
    • /
    • 2005
  • HVDC(High Voltage Direct Current) is an underwater cable between Jeju Island and Haenam in main land and supplies approximately 50% of electrical usage in Jeju Island. If there is any power failure due to HVDC, it will cost approximately 50,000 US dollars per day including Thermal Electrical Generation. Therefore it is absolutely necessary to recover the problem in rapid timely basis. In conclusion, evaluation methode of HVDC cable is needed urgently to upgrade current HVDC underwater cable repair technique in Korea to minimize the cost and time factors.

  • PDF

Bayesian Analysis for Multiple Change-point hazard Rate Models

  • Jeong, Kwangmo
    • Communications for Statistical Applications and Methods
    • /
    • 제6권3호
    • /
    • pp.801-812
    • /
    • 1999
  • Change-point hazard rate models arise for example in applying "burn-in" techniques to screen defective items and in studing times until undesirable side effects occur in clinical trials. Sometimes in screening defectives it might be sensible to model two stages of burn-in. In a clinical trial there might be an initial hazard rate for a side effect which after a period of time changes to an intermediate hazard rate before settling into a long term hazard rate. In this paper we consider the multiple change points hazard rate model. The classical approach's asymptotics can be poor for the small to all moderate sample sizes often encountered in practice. We propose a Bayesian approach avoiding asymptotics to provide more reliable inference conditional only upon the data actually observed. The Bayesian models can be fitted using simulation methods. Model comparison is made using recently developed Bayesian model selection criteria. The above methodology is applied to a generated data and to a generated data and the Lawless(1982) failure times of electrical insulation.

  • PDF

커튼월 이중 유리 외장재 파단에 대한 실험 및 수치해석 연구 (Experimental and Numerical Studies on the Failure of Curtain Wall Double Glazed for Radiation Effect)

  • 남지우;유홍선;김동준;김성원;남준석;조성욱
    • 한국화재소방학회논문지
    • /
    • 제29권6호
    • /
    • pp.40-44
    • /
    • 2015
  • 국내외 유리 외장재에 대한 기준은 풍압 및 단열 성능에만 집중되어 있고, 화재 및 지진과 같은 재난에 대한 기준은 미비한 실정이다. 특히 초고층 건물의 화재 발생 시 유리 외장재의 파손으로 인한 상부층 화재 확산은 재산 및 인명 피해를 극대화한다. 따라서 유리 외장재의 파손으로 인한 화재 확산을 축소하기 위해서는 유리 외장재의 화재 취약성을 검토하고 파손 방지 기술 개발이 필요하다. 초고층 건물의 한정된 소방용수를 사용하여 효과적으로 파손을 막기 위해서는 유리 외장재의 파손 시점을 예측하고 원인 인자를 판단하는 것이 중요하다. 본 연구에서는 이중 유리 외장재의 열적 특성을 분석하기 위해 복사열 실험을 수행하고, 화염의 고온 고압에 직접적으로 노출이 되지 않았음에도 파단이 일어난 현상을 분석하기 위한 수치해석을 수행하였다. 구체적으로 ISO 9705 Room에 3장의 커튼월 유리 외장재를 설치하고, 방열판을 이용해서 유리 외장재를 복사열에 노출시키며 각 유리의 중요 위치에서 열전대를 이용하여 온도를 측정하였다. 최종적으로 현재 널리 사용되고 있는 이중 유리 외장재에 대한 화재 취약성을 분석하였다.

열저항 효과를 고려한 $9\%$ 니켈강재식 LNG 저장탱크의 누설 안전성에 관한 연구 (On the Leakage Safety Analysis of $9\%$ Nickel Type LNG Storage Tank with Thermal Resistance Effects)

  • 김청균;조승현;서홍석;홍성호;이승림;김영규;권부길
    • 한국가스학회지
    • /
    • 제9권1호
    • /
    • pp.1-8
    • /
    • 2005
  • 본 연구에서는 $9\%$ 니켈강재식 LNG저장탱크에 대한 누설 안전성을 여러 가지 단열재와 코너 프로텍션, PC 구조물 사이에 존재하는 열저항 평형온도 효과를 고려하여 유한요소법으로 해석하였다. FEM 계산결과에 따르면, 파이버 글라스 블랑켓, 펄라이트 파우더, 셀루러 글라스 단열재 등은 재질의 취약한 강도 때문에 누설 LNG에 의한 하중이 가해지면 단열재 자체가 파손되므로 누설 안전성을 보장할 수 없게 된다. 그러나, 내부탱크와 단열재가 동시에 파손되어도 $9\%$ 니켈강재로 제작된 코너 프로텍션(CP) 예응력 콘크리트(PC)구조물의 외부탱크는 LNG의 복합하중에 대하여 강도 안전성을 확보하고 있으므로, 누설 LNG를 최소한 10일 정도는 안전하게 체류시킬 수 있다. 따라서, $9\%$ 니켈강제식 LNG 저장탱크 시스템은 이들 두 가지 구조물에 의해 누설 안전성이 확보된다.

  • PDF

수치해석을 이용한 Mark-III LNG 1차 방벽에 대한 피로 평가 (A numerical study on the fatigue evaluation of mark-III LNG primary barrier)

  • 권순범;김명성;이제명
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제41권4호
    • /
    • pp.337-344
    • /
    • 2017
  • 환경 문제로 인해 기존 연료를 대체하는 천연가스의 수요가 증가하고 있다. 이에 따라, 액화천연가스 운반선의 화물창이 거대화되면서 화물창 내의 슬로싱 하중이 증가하게 된다. 액화천연가스 화물창의 종류 중 하나인 Mark-III 타입의 1차 방벽은 액화천연가스와 직접적으로 접촉하고 있으며 슬로싱 하중 및 액화천연가스의 자중을 받는다. 슬로싱 하중에 의해 다양한 범위의 하중이 1차 방벽에 지속적으로 작용하며 이로 인해 피로 파괴를 유발할 수 있다. 따라서 본 연구에서는 Mark-III 타입의 1차 방벽을 포함한 단열시스템을 유한요소 모델로 구성하였으며 1차 방벽에 대해 피로수명을 평가하여 피로 특성을 확인하였다. 수치해석을 통해 주응력 범위 및 최대 주응력이 발생하는 위치를 계산하였으며 이를 통해 1차 방벽의 피로수명을 수치적으로 평가하였다. 또한, 다양한 단열시스템 타입에 대해 모델링을 실시하였으며, 피로수명 평가 결과를 통해 1차 방벽의 피로 파괴 안전성을 확보하는 최적의 단열시스템에 대해 제안하였다. 본 연구의 결과는 Mark-III 타입 1차 방벽의 피로 기반 설계에 있어 활용가치가 있을 것으로 판단된다.

Effect of Applied Voltage Bias on Electrochemical Migration in Eutectic SnPb Solder Alloy

  • Lee, Shin-Bok;Jung, Ja-Young;Yoo, Young-Ran;Park, Young-Bae;Kim, Young-Sik;Joo, Young-Chang
    • Corrosion Science and Technology
    • /
    • 제6권6호
    • /
    • pp.282-285
    • /
    • 2007
  • Smaller size and higher integration of electronic systems make narrower interconnect pitch not only in chip-level but also in package-level. Moreover electronic systems are required to operate in harsher conditions, that is, higher current / voltage, elevated temperature / humidity, and complex chemical contaminants. Under these severe circumstances, electronic components respond to applied voltages by electrochemically ionization of metals and conducting filament forms between anode and cathode across a nonmetallic medium. This phenomenon is called as the electrochemical migration. Many kinds of metal (Cu, Ag, SnPb, Sn etc) using in electronic packages are failed by ECM. Eutectic SnPb which is used in various electronic packaging structures, that is, printed circuit boards, plastic-encapsulated packages, organic display panels, and tape chip carriers, chip-on-films etc. And the material for soldering (eutectic SnPb) using in electronic package easily makes insulation failure by ECM. In real PCB system, not only metals but also many chemical species are included. And these chemical species act as resources of contamination. Model test systems were developed to characterize the migration phenomena without contamination effect. The serpentine-shape pattern was developed for analyzing relationship of applied voltage bias and failure lifetime by the temperature / humidity biased(THB) test.

수냉각 발전기 고정자 권선의 건조 과정 분석을 통한 누설 및 흡습 예측 진단에 관한 실험적 연구 (Experimental Study on Prediction and Diagnosis of Leakage and Water Absorption in Water-Cooled Generator Stator Windings by Drying Process Analysis)

  • 김희수;배용채;이욱륜;이두영
    • 대한기계학회논문집B
    • /
    • 제34권9호
    • /
    • pp.867-873
    • /
    • 2010
  • 수냉각 발전기 고정자 권선에서의 냉각수 누수 및 흡습에 의한 절연파괴 손상사례가 국내 및 국외에서 자주 발생되고 있다. 이러한 사고는 막대한 경제적 피해뿐만 아니라 전력의 안정적 공급 측면에서 매우 심각한 계통 사고로 연결될 수 있다. 특히 국내 발전기는 15년 이상 운전되어 열화가 진행된 발전기가 50% 이상이며, 계획예방정비 기간 중에 권선에서의 누설 및 흡습 권선이 종종 발견되고 있다. 기존에는 누수 시험 전 과정인 권선 건조 과정을 무시한 채 누수 시험 결과만으로 권선 누설 여부를 진단하였으나 본 논문에서는 누수 시험을 위한 준비 단계인 진공 건조 시의 권선 내부의 진공도 패턴 분석을 통해 권선 누설 및 흡습 여부를 예측진단할 수 있는 방법을 실험적으로 증명하였다.

마이카 고전압 커패시터의 환경시험과 가속 수명시험을 통한 신뢰성 평가 (Reliability assessment of mica high voltage capacitor through environmental test and accelerated life test)

  • 박성환;함영재;김정석;김경훈;소성민;전민석
    • 한국결정성장학회지
    • /
    • 제29권6호
    • /
    • pp.270-275
    • /
    • 2019
  • 마이카 커패시터는 세라믹 커패시터에 비해 내고충격 특성이 우수하여 다양한 유도무기체계의 고전압 기폭장치에 적용된다. 본 연구에서는 국산화된 마이카 고전압 커패시터의 고전압 기폭장치 적용을 위해 단자강도시험, 내습성시험, 열충격시험과 같은 환경시험과 함께 가속 수명 시험을 진행하였다. 마이카 고전압 커패시터의 고장모드는 절연저항 감소 및 이를 통한 절연 파괴이다. 가속수명모델의 중요 상수를 실험적으로 도출하였으며 전압계수 n 및 활성화 에너지 Ea는 각각 5.28 및 0.805 eV이었다. 가속모델식을 이용하여 도출한 가속계수는 496이었으며 가속수명시험을 통해 도출된 정상 사용 조건에서의 마이카 고전압 커패시터의 수명은 38.5년으로 기폭장치 적용에 문제가 없는 것으로 확인되었다.

EPR의 가속 열화에 의한 기계적 특성 및 통계적 평가 (Mechanical Properties and Statistical Evaluation of EPR According to the Accelerated Degradation)

  • 김지연;양종석;이길수;성백용;방정환;박대희
    • 한국전기전자재료학회논문지
    • /
    • 제28권8호
    • /
    • pp.501-507
    • /
    • 2015
  • In this paper, EPR (ethylene propylene rubber) insulation material was accelerated degradation test at $121^{\circ}C$, $136^{\circ}C$, $151^{\circ}C$, and experiment the typical EAB (elongation at break) at mechanical characteristics analysis. It is shown that the failure-time at the point of 50% of the initial value of Elongation rate to obtain the activation energy. The failure-time was shown each 5,219 hr, 3,165 hr, and 668 hr at three temperatures. In order to derive the activation energy, Arrhenius methodology was applied. Also, we got the Arrhenius plot from three accelerated temperatures. The activation energy values got 0.98 eV from EAB test. The experimental data were evaluated for estimating the probability density, and the suitable distribution by using statistical program MINITAB. It is shown that EAB data by the acceleration thermal degradation is most suitable for the Weibull distribution.

절연유(絶緣油) 열화(劣化)센서 특성(特性) 연구(硏究) (A Study on the characteristics of degradation sensor for insulation oil)

  • 전영갑;선종호;강동식;주병수;윤진열;정상진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1371-1374
    • /
    • 1995
  • It is well known that the degradation of transformer oil conseqently lead to the failure of transformer. This paper discussed the characteristics of the degradation sensor checking transformer oil condition in live line. The degadation sensor is composed of base ring, electrodes and porous ceramic, passed through the transformer oil and checks the transformer oil condition through sensor's leakage current. So it is important to minimize the leakage current of base ring and connection parts. To investigate the leakage current of base ring and connection parts the characteristics of V-T-I and DC 2 KV and other examinations were performed. It is verified that ionized transformer oil caused by the expansion of temperature increases in the leakage current of porous ceramic sensor. It is certification that the leakage current of other parts of porous ceramic is very small(about 2%) compared with the porous ceramic body and it is confirmed that the leakage current in porous ceramic is changed sensitively according to the new oil(NO) and and the degradation oil(DO).

  • PDF