• Title/Summary/Keyword: Insulation defect

Search Result 103, Processing Time 0.033 seconds

A Field Investigation of Defect Type for Development of Maintenance Manual of Han-ok (한옥 유지관리매뉴얼 개발을 위한 결함 유형 현장 조사)

  • Lee, Jong Shin;Choi, Gwang Sik;Yang, Jeong Moo
    • Journal of the Korea Furniture Society
    • /
    • v.24 no.3
    • /
    • pp.302-308
    • /
    • 2013
  • To collection of field data for development of maintenance manual of Han-ok, we investigated defects which occurred in members of Han-ok by field investigation. The noticeable defects were wood cracks, gaps that developed between wood pillar and wall or wood window frame and tenon joints. The most common biological defect was blue stain which was created in log. The mold generation was observed on exterior wood and wall which get wet by precipitation. The gaps between members of Han-ok pointed out as defect that is urgently improved by residents of Han-ok. The reason is mainly due to poor of insulation in winter by bad confidentiality. The maintenance work of defect such as gap was conducted personally. As a result, the repair parts were ugly for unfamiliar repair work.

  • PDF

Analysis on Defect Disputes in Housing & Interior Design from Consumers' Perspective and Interior Design Service Evaluation (소비자 관점에서 본 주택 및 인테리어 하자 실태 분석 및 인테리어 서비스 평가)

  • Lee, So Young;Jun, Gyung Min
    • Journal of the Korean housing association
    • /
    • v.27 no.5
    • /
    • pp.65-72
    • /
    • 2016
  • The purpose of the study was to investigate defect cases in residential interior design, to identify the state of defects, and to categorize types of defect and disputes. In addition, consumer appraisal to residential interior design service were analyzed. The results of this study could provide fundamental information regarding the defects and claims in residential interior design. First, we did literature review for defect disputes in architectural design and interior design. We identify the definition of defects by building life cycle, by state of construction, by activity, and by design performance. Second, we analysed interior design defects cases reported in Korea Consumer Agency & Ministry of Land, Infrastructure and Transport. A total of 49 cases of defect disputes in residential interior design from 2000 to 2015 were investigated. As a result, many defects appeared during the construction stage. A majority of defects cases fall into insulation, water-proofing/leakage work. In terms of design aspects claim, functional and aesthetic defects were claimed. Third, from Consumer Market Evaluation Indicators, raw data from 500 respondents were investigated for the housing repair and interior design. It is found that information comparability, responsiveness to consumer claim, price, and safety are important factors for consumer satisfaction in interior design.

Judgement Criterion of Insulation Deterioration in 4.16kV and 6.6kV Motor Stator Windings (4.16kV 및 6.6kV 전동기 고정자 권선의 절연열화 판정기준)

  • Kim, Hee-Dong
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.4
    • /
    • pp.788-794
    • /
    • 2009
  • To assess the condition of stator insulation, nondestructive tests were performed on twenty five coil groups and twenty six motors. The stator windings has nominal ratings of 6.6kV and are classified into five coil groups ;one group with healthy insulation and four groups with four different types of artificial defects. After completing nondestructive tests, the AC voltage applied to the stator windings was gradually increasing until insulation failure in order to obtain the breakdown voltage. No.1, No.2 and No.6 of 6.6kV motors failed near rated voltage of 14kV, 8.7kV and 14kV, respectively. The breakdown voltage of three motors was lower that expected for good quality coils(14.2kV) in 6.6kV motors. No.3 and No.6 of 4.16kV motors failed near rated voltage of 5.6kV and 4.2kV, respectively. Almost all of failures were located in a line-end coil at the exit from the core slot. The breakdown voltages and the types of defects showed strong relation to the stator insulation tests such as in the case of AC current, dissipation factor(tan${\delta}$) and partial discharge magnitude.

Partial Discharge Process and Characteristics of Oil-Paper Insulation under Pulsating DC Voltage

  • Bao, Lianwei;Li, Jian;Zhang, Jing;Jiang, Tianyan;Li, Xudong
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.2
    • /
    • pp.436-444
    • /
    • 2016
  • Oil-paper insulation of valve-side windings in converter transformers withstand electrical stresses combining with AC, DC and strong harmonic components. This paper presents the physical mechanisms and experimental researches on partial discharge (PD) of oil-paper insulation at pulsating DC voltage. Theoretical analysis showed that the phase-resolved distributions of PDs generated from different insulated models varied as the increase of the applied voltages following a certain rule. Four artificial insulation defect models were designed to generate PD signals at pulsating DC voltages. Theoretical statements and experimental results show that the PD pulses first appear at the maximum value of the applied pulsating DC voltage, and the resolved PD phase distribution became wider as the applied voltage increased. The PD phase-resolved distributions generated from the different discharge models are also different in the phase-resolved distributions and development progress. It implies that the theoretical analysis is suitable for interpretation of PD at pulsating DC voltage.

Characteristic Analysis and Origin Positioning of Acoustic Signals Produced by Partial Discharges in Insulation Oil

  • Park, Dae-Won;Jo, Hyang-Eun;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1468-1473
    • /
    • 2013
  • This paper dealt with the propagation characteristics of acoustic signals produced by partial discharges and the positioning of PD origin in insulation oil to develop insulation diagnostic techniques of oil-immerged transformers. Electrode systems such as needle to plane, plane to plane, and particle electrodes were fabricated to simulate some defects of power transformers. In addition, the frequency spectrum and propagation characteristics of acoustic signals with partial discharge (PD) in insulation oil were analyzed. Although there were differences based on the type of defect, the frequency spectra of the acoustic signals measured by wide and narrow band acoustic emission (AE) sensors were distributed in the range of 50 kHz-400 kHz. Therefore, a narrowband AE sensor is suitable for the diagnosis of oil-immersed power transformers. We could find the position of the PD source with an error margin of 10% in the experiments by calculating the position of the PD occurrence using the time difference of arrival measured by five AE sensors.

Comparative Performance Evaluation by Winter Apartment Temperature on the Outer Surface of the Insulation (동계 아파트 외표면 온도에 의한 단열성능 비교평가)

  • Park, Jung-Hun;Kim, Bong-Joo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.4
    • /
    • pp.91-100
    • /
    • 2013
  • This research is to measure and analyze the thermal performance of the apartment structure and to evaluate and establish standards of thermal insulation defect in order to make the basic data necessary for determining the degree of the thermal performance degradation and for repairing and reinforcing the exterior wall of the existing apartment. Furthermore, it is to predict the part of occurrence of the thermal bridge and condensation at the apartment building structure. On the other one hand, it is also to analyze the degree of thermal insulation performance according to the standards of thermal insulation and elapsed time, through the analysis by the workability of concrete.

Defect detection of vacuum insulation panel using image analysis based on corner feature detection (코너 특정점 기반의 영상분석을 활용한 진공단열재 결함 검출)

  • Kim, Beom-Soo;Yang, Jeonghyeon;Kim, Yeonwon
    • Journal of the Korean institute of surface engineering
    • /
    • v.55 no.6
    • /
    • pp.398-402
    • /
    • 2022
  • Vacuum Insulation Panel (VIP) is an high energy efficient insulation system that facilitate slim but high insulation performance, based on based on a porous core material evacuated and encapsulated in a multi-barrier envelope. Although VIP has been on the market for decades now, it wasn't until recently that efforts have been initiated to propose a standard on aging testing. One of the issues regarding VIP is its durability and aging due to pressure and moisture dependent increase of the initial low thermal conductivity with time. It is hard to visually determine at an early stage. Recently, a method of analyzing the damage on the a material surface by applying image processing technology has been widely used. These techniques provide fast and accurate data with a non-destructive way. In this study, the surface VIP images were analyzed using the Harris corner detection algorithm. As a result, 171,333 corner points in the normal packaging were detected, whereas 32,895 of the defective packaging, which were less than the normal packaging. were detected. These results are considered to provide meaningful information for the determination of VIP condition.

A study on the sound insulation performance of damping sheet attached to the train wall (철도차량벽체의 차음 성능에 대한 제진시트의 영향 고찰)

  • Seo, Dae-Hoon;Kim, Yang-Hann
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.97-100
    • /
    • 2007
  • This study deals with the sound insulation performance of the damping sheet, which is widely used in a train. The wall of train is assumed to be a plate made of steel and two damping sheets. In case of damping sheet only, the sound transmission loss follows the mass law. If a steel plate is attached to damping sheet, the transmission loss is found to be higher than single of only steel plate, as we can anticipated, about $3{\sim}5$ dB. This is very well known consequence that is because the density of area increases. However, the increase of the transmission loss is not higher than what we can expect by the mass law. That's because the steel is perfectly blocked from the transmission of the air ; There is no defect in that material.

  • PDF

Analysis of Insulation Aging in Operating High Voltage Motors (운전중인 고압전동기에서 절연열화 분석)

  • Kim, Hee-Dong;Ju, Young-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2175-2178
    • /
    • 2005
  • During normal machine operation, partial discharge(PD) measurements were performed with turbine generator analyzer(TGA) in five high voltage motors(rated 6.6kV). These high voltage motors were installed with 80pF capacitive couplers at the terminal box. The PD patterns were displayed two dimensional and three dimensional. TGA summarizes each plot with two quantities such as the normalized quantity number(NQN) and the peak PD magnitude(Qm). Off-line PD measurements were conducted on five motors. These motors were energized to 3.81kV. The PD levels in pC were measured with a conventional digital PD detector. The comparison of positive to negative PD indicates whether the defect elements of PD are within the insulation or on the insulation surface. Internal discharges were generated in phase A, B and C of COP-B and pulv.-B, in phase B of Pulv. C and in phase C of Pulv.-D motor. Discharge at conductor surface was discovered in phase A of Pulv. D motor. Slot discharges occurred in three phases of Pulv. E motor.

  • PDF

Partial Discharge Diagnosis of Interface Defect by the Distribution Statistical Analysis (분포 통계 해석에 의한 계면 결함 부분방전 진단)

  • Cho, Kyung-Soon;Lee, Kang-Won;Kim, Won-Jong;Hong, Jin-Woong;Shin, Jong-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.4
    • /
    • pp.348-353
    • /
    • 2008
  • Most of the high voltage insulation systems, such as the power cable joint having hetero interface, are composed of more than two different insulators to improve insulating performance. The partial discharge(PD) in these hetero interface is expected to affect the total insulation performance. Thus, it is important to study electrical properties on these interfaces. This study described the influence of copper and semiconductive substance defects on $\Phi$-q-n distribution between the interface of the model cable joints to classify PD source. PD was sequentially detected for 600 cycles of the applied voltage. The K-means cluster analysis has been analyzed to investigate the $\Phi$-q-n distribution. The skewness-kurtosis(Sk-Ku) plot from K-means clustering results was defined to quantify cluster distribution and classify distribution patterns. The Sk-Ku plot is composed of skewness and kurtosis along abscissa and ordinate which indicate the asymmetry and the sharpness of distribution. As a result of the Sk-Ku plot, it was confirmed that the data was distributed in 1st 2nd and 3rd quadrant at copper foreign substance defect, but in case of semiconductive foreign substance, the data was distributed in 2nd quadrant only.