• 제목/요약/키워드: Insulation breakdown test

검색결과 158건 처리시간 0.023초

Correlation between Insulation Diagnostic Test and AC Breakdown Test for 3.3 kV Class Induction Motor

  • Byun, Doo-Gyoon;Hong, Jin-Woong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.262-266
    • /
    • 2006
  • The insulation diagnostic test and the AC breakdown test were performed under off-line using the 3.3 kV class induction motor which have been served for 10 years. These tests were conducted in means of nondestructive and destructive test. In this paper, we compared the correlation between the nondestructive and destructive test. Furthermore we setup an experimental condition with moisture and compared the insulation characteristics between moist and dry sample. From the results of the nondestructive and destructive test, it was found that the second AC current, which is the previous step of insulation breakdown, suddenly increased at a point of around 8.5 kV. The insulation breakdown of moist sample occurred at 12-14 kV, which is 4-5 kV lower than dry sample.

Characteristics of Insulation Diagnosis and Failure in Gas Turbine Generator Stator Windings

  • Kim, Hee-Dong
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.280-285
    • /
    • 2014
  • In order to evaluate the insulation deterioration in the stator windings of five gas turbine generators(137 MVA, 13.8 kV) which has been operated for more than 13 years, diagnostic test and AC dielectric breakdown test were performed at phases A, B and C. These tests included measurements of AC current, dissipation factor, partial discharge (PD) magnitude and capacitance. ${\Delta}I$ and ${\Delta}tan{\delta}$ in all three phases (A, B and C) of No. 1 generator stator windings showed that they were in good condition but PD magnitude indicated marginally serviceable and bad level to the insulation condition. Overall analysis of the results suggested that the generator stator windings were indicated serious insulation deterioration and patterns of the PD in all three phases were analyzed to be internal, slot and spark discharges. After the diagnostic test, an AC overvoltage test was performed by gradually increasing the voltage applied to the generator stator windings until electrical insulation failure occurred, in order to determine the breakdown voltage. The breakdown voltage at phases A, B and C of No. 1 generator stator windings failed at 28.0 kV, 17.9 kV, and 21.3 kV, respectively. The breakdown voltage was lower than that expected for good-quality windings (28.6 kV) in a 13.8kV class generator. In the AC dielectric breakdown and diagnostic tests, there was a strong correlation between the breakdown voltage and the voltage at which charging current increases abruptly ($P_{i1}$, $P_{i2}$).

견인전동기 고정자 권선의 절연상태 분석 (Analysis of Insulation Condition in Traction Motor Stator Windings)

  • 김희동;박영
    • 한국전기전자재료학회논문지
    • /
    • 제20권7호
    • /
    • pp.631-635
    • /
    • 2007
  • Diagnostic, surge and ac breakdown tests are widely used to evaluate the insulation condition of stator winding in traction motor. Diagnostic test included ac current, tan delta and maximum partial discharge. The result of diagnostic test indicates that five kinds of stator windings are good condition. Surge test was peformed to confirm the healthy of turn insulation in stator windings. This test is very easy to detect the turn insulation failure between normal and defect stator windings. After completing the diagnostic test, ac breakdown test has conducted gradually increasing ac voltage, until the stator winding punctured. No. 5 stator windings failed near rated voltage of 18.9 kV The breakdown voltage of No. 1 stator windings was 13.0 kV The ac breakdown voltage of normal winding is about 1.45 times higher than that of defect windings. The failure was located in a line-end coil at the exit from the core slot.

절연파괴시험법을 이용한 3.3[kV] 유도전동기의 절연물 열화특성 분석 (Analysis of Aging Insulation Characteristics of 3.3[kV] Class Induction Motor with AC Breakdown Test)

  • 이주;김현일;김윤현;손영규
    • 조명전기설비학회논문지
    • /
    • 제21권10호
    • /
    • pp.141-149
    • /
    • 2007
  • 본 논문은 유도전동기 고정자권선의 절연물에 대하여 비파괴 및 파괴시험을 실시하여 절연물의 비파괴특성과 내전압강도와의 상호관계를 비교, 평가, 분석함으로써, 향후 전동기의 절연상태 평가시 수명 및 절연진단의 신뢰성을 도모하고자 제안하였다. 본 논문에서는 비파괴시험과 파괴시험과의 상관관계를 평가하기위하여 비파괴시험으로 절연저항시험, 성극지수시험, 유전정접시험, 부분방전시험을 실시하였으며, 파괴시험은 60[kV] AC 내전압를 이용하여 실시하였다. 또한 장기간 사용된 전동기 권선의 절연물에 대한 연구결과로부터 기존 선진국의 진단방법 및 판정기준이 국내에서 제작된 전동기에 대한 절연특성 평가 및 분석에도 타당함을 증명하였으며, 향후 본 논문에서 제시한 자료들은 유사조건의 산업현장에서 운용중인 유도전동기의 수명 및 상태 평가를 위한 기초자료로 유용하게 사용될 수 있으리라 기대된다.

절연파괴시험을 통한 3.3kV 유도전동기의 절연특성 연구 (A study on insulation characteristics with AC Breakdown Test for Stator Winding of 3.3kV class Induction Motor)

  • 이동근;이광호;최교남;김현일;곽희진;오봉근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2118-2122
    • /
    • 2005
  • This test was performed to assess the corelation of insulation deterioration condition with breakdown voltage of the stator winding of 3.3kV class induction motors which have been in service for 10 years after being installed in 1993. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor$({\Delta}tan{\delta})$, maximum partial discharges (Qmax) and AC breakdown test. we evaluated the corelation of insulation diagnostic test with AC breakdown test for stator wilding of high voltage induction motor.

  • PDF

Electrical Insulation Breakdown Strength in Epoxy/Spherical Alumina Composites for HV Insulation

  • Park, Jae-Jun
    • Transactions on Electrical and Electronic Materials
    • /
    • 제14권2호
    • /
    • pp.105-109
    • /
    • 2013
  • In order to develop high voltage (HV) insulation materials, epoxy/spherical alumina composites with two different particle sizes (in ${\mu}m$) were prepared and a dynamic mechanical analysis (DMA) and electrical insulation breakdown strength test were carried out in sphere-sphere electrodes and the data were estimated using Weibull statistical analysis. Alumina content varied from 50 to 70 wt%. The electrical insulation breakdown strength for epoxy/alumina (50 wt%) was 44.0 kV/1 mm and this value decreased with increasing alumina content. The effects of insulation thickness and alumina particle size on the insulation breakdown strength were also studied. The insulation thickness varied from 1 mm to 3 mm, and the particle sizes were 7.3 or $40.3{\mu}m$.

고압유도전동기 절연특성시험의 신뢰도 평가 (Evaluation of Insulation Diagnostic Test Reliability for Stator Winding of High Voltage Induction Motor)

  • 이광호;김현일;곽희진;오봉근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1838-1841
    • /
    • 2004
  • This test was performed to assess the correlation between insulation diagnostic tests and breakdown voltage strength of the stator winding of 6.6kV class induction motor in insulation deterioration condition which have been in service for 5 years after being installed in 1998. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor(${\triangle}tan{\delta}$), maximum partial discharges(Qmax) and AC breakdown test. we evaluated the correlation between insulation diagnostic test and AC breakdown test for stator winding of high voltage induction motor.

  • PDF

고압유도전동기 절연특성시험의 신뢰도 평가 (Evaluation of Insulation Diagnostic Test Reliability for Stator Winding of High Voltage Induction Motor)

  • 이광호;김현일;곽희진;오봉근
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.46-49
    • /
    • 2004
  • This test was performed to assess the correlation between insulation diagnostic tests and breakdown voltage strength of the stator winding of 6.6kV class induction motor in insulation deterioration condition which have been in service for 5 years after being installed in 1998. The insulation diagnostic tests include resistance, polarization index(P.I), dissipation factor(${\Delta}tan{\delta}$). maximum partial discharges(Qmax) and AC breakdown test. we evaluated the correlation between insulation diagnostic test and AC breakdown test for stator winding of high voltage induction motor.

  • PDF

전극 형태와 전극 간 거리에 따른 전기적 특성 분석 (Electrical Characteristics Analysis According to Electrode Shape and Distance Between Electrodes)

  • 김태희;이순형;황미용;최용성
    • 한국전기전자재료학회논문지
    • /
    • 제36권4호
    • /
    • pp.408-412
    • /
    • 2023
  • In this paper, in order to analyze high electrical insulation and cooling performance using mineral oil, the liquid insulating oil was changed in electrode shape and distance between electrodes to compare and analyze electrical characteristics according to equal electric field, quasi-equivalent electric field, and unequal electric field. As a result, the breakdown voltages were 36,875 V and 36,875 V in the form of sphere-sphere and plate-plate electrodes with equal electric fields. The breakdown voltage was 31,475 V in the sphere-plate electrode type, which is a quasi-equilibrium field, and the breakdown voltage was 28,592 V, 27,050 V, and 22,750 V in the needle-needle, sphere-needle, and needle-plate electrode types, which are unequal fields. Through this, it is possible to know the difference in breakdown voltage according to the type of electric field. The more equal the field, the higher the breakdown voltage, and the more unequal field, the lower the breakdown voltage. The difference in insulation breakdown voltage could be seen depending on the type of electric field, the insulation breakdown voltage was higher for the more equal electric field, and the insulation breakdown voltage was lower for the more unequal electric field. Also, it was confirmed that the closer the distance between the electrodes, the higher the insulation breakdown voltage, the higher the insulation breakdown current, and the insulation breakdown voltage and the insulation breakdown current were proportional.

154 kV급 HTS 케이블의 절연설계 및 굴곡시험 (Design of Insulation and Bending Test for a 154 kV Class HTS Cable)

  • 최진욱;최재형;임응춘;김해종;조전욱;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제21권11호
    • /
    • pp.1024-1028
    • /
    • 2008
  • It is important that study on cryogenic electrical insulation design to develop the cold dielectric(CD) type HTS cable because the cable is operated under the high voltage environment in cryogenic temperature. This paper proposes two types of insulation design to carry out the maximum insulation design for 154 kV-class HT cable. The proposed insulation design method takes into consideration AC and lightning impulse withstand voltage so as to prevent AC breakdown for power frequency operating voltage during operating the cable and breakdown for lightning impulse voltage. The final insulation thickness is determined by selecting high value out of two insulation thickness calculated through the two insulation design methods. And we researched electrical insulation characteristics of HTS cable according to bending ratio and the number of bending.