• 제목/요약/키워드: Insulation and Condensation Performance Evaluation

검색결과 14건 처리시간 0.022초

Calculation of Adequate Remodeling Period for The Improvement of Thermal Insulation Performance of External Walls in Deteriorated Apartments

  • Choi, Doo-Sung;Lee, Myung-Eun
    • KIEAE Journal
    • /
    • 제17권2호
    • /
    • pp.5-12
    • /
    • 2017
  • Purpose: Under the purpose of presenting the adequate remodeling period for the improvement of thermal insulation performance of external walls in deteriorated buildings, the change in external wall and residential environment problem(dew condensation) due to aged deterioration after the apartments were constructed in Korea were analyzed. Method: Temperature Difference Ratio Outside(TDRo) and Heat Flow Meter(HFM) were used as measurement methods to evaluate the thermal insulation performance of deteriorated buildings. For TDR evaluation, thermo-graphic camera was used to measure and analyze the surface temperature of external wall. Also, dew condensation evaluation was analyzed using the Temperature Difference Ratio Inside(TDRi). Result: As a result of analyzing thermal performance through TDRo, the first decline point of thermal insulation performance began after 14-16 years have passed since construction was completed, and after 20 years have passed the decline point of thermal insulation performance reappeared. As a result of analyzing U-value with HFM measurement method, the decline rate of external wall's thermal insulation performance is lower than 2% in average at around 5 years after completion, and 8.7% in average at 10-15 years, and over 10.2% in average at 20 years.

Prototype Development for BIM based Thermal Insulation and Condensation Performance Evaluation of Apartment Housings

  • Oh, Hyangok;Cho, Daegu;Jang, Hyang-In;Hong, Soungwook;Lee, Myung Sik
    • Architectural research
    • /
    • 제17권2호
    • /
    • pp.75-81
    • /
    • 2015
  • Insulation and condensation performance evaluation (I&CPE) is an important energy analysis. While considerable amount of data are already represented in a Building Information Model (BIM), the lack of interoperability between BIM modeling and I&CPE programs prevents the simulation process from being efficient and accurate. This study proposes a prototype of a BIM-based I&CPE simulation program, in order to enhance the interoperability between BIM modeling and I&CPE programs. This study discusses the information flow process, defines the required information and its level of detail, develops standardized libraries, and finally proposes a prototype that consists of a data extraction module, conversion module, and performance module. The assurance of interoperability between systems might greatly benefit architects and energy professionals.

3차원 정상상태 해석에 의한 공동주택 단열성능 평가 - TDR(온도상대비)을 중심으로 - (Insulation Performance Evaluation of Apartment Housing Bying a Three-Dimensional Steady State Simulation)

  • 최보혜;최경석;강재식;이승언;이용준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.730-735
    • /
    • 2009
  • The purpose of this study is to consider improvement performance to prevent condensation and draw the optimum insulation design method for building using simulation tool. In this study, the three corners, weak part in condensation, were conducted by three-dimensional steady state simulation. From the results, it is required to strengthen insulation design, and it is founded that existing insulation system typically applied to most Korean apartment buildings has serious insulation defect that insulation is disconnected by structural components at the joints of wall-slab and wall-wall in envelope. So, it is considerate to need a concrete technology improvement.

  • PDF

적외선 열화상을 이용한 공동주택 단열성능 평가 : TDR(온도차비율)을 중심으로 (Thermal Performance Evaluation of Apartment Housing Using Infra-red Camera)

  • 최경석;손장열
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.404-412
    • /
    • 2010
  • The purpose of this study is to accomplished an in-site evaluation method for existing building insulation status using Infra-red camera and to consider improvement performance to prevent condensation and draw the optimum insulation design method for building using simulation tool. The research contents of this study are to evaluate validity and suitability of building insulation defect survey using Infra-red camera for apartment housing with temperature and heat flow pattern analyze method. Based on this research, the three corners, weak part in condensation, were selected in apartment building and conducted simulation by three-dimensional steady state. From the results, it is required to strengthen insulation design, and it is founded that existing insulation system typically applied to most Korean apartment housings have serious insulation defect that insulation is disconnected by structural components at the joints of wall-slab and wall-wall in envelope. Thus, it is considerate to need a concrete technology improvement.

An Experimental Study on the Evaluation of Fastening Unit Insulation Developed for the Insulation of Curtain Wall

  • Kim, Bong-Joo;Kim, Kyeong-A
    • 한국건축시공학회지
    • /
    • 제12권2호
    • /
    • pp.243-256
    • /
    • 2012
  • This study is the experimental study to improve the insulation of the fastening unit system, which has the most vulnerable insulation in the curtain walls. The Fastening Units were designed and fabricated to minimize the connection part of mullions. In addition, slight movements were taken into account and the performance of the middle layer was evaluated by forming an insulation layer with the vibration-proof rubber and the silicon to satisfy the mechanical and thermal performance criteria. A total of 10 experiments were performed under various conditions, such as indoor-outdoor temperature difference, type of insulation material, thickness of insulation material, and others. using the fabricated Fastening Units. As a result, the vibration-proof rubber insulation showed the temperature difference of $2.2^{\circ}C-5.0^{\circ}C$, and the silicon insulation showed the temperature difference of $2.8^{\circ}C-4.5^{\circ}C$, compared to the non-insulated Fasteniirature difference, typesng Units. When these results were compared with the psychometric chart graph, the insulated Fastening Unit designed in this study can be considered to prevent the dew condensation.

ALC 패널 커튼월의 패스닝 유닛의 단열 방법과 성능 평가 (Insulation Method and Performance Evaluation for Fastening Unit of ALC Pannel-Curtain wall)

  • 김봉주;김경아;박재민
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 춘계 학술논문 발표대회 1부
    • /
    • pp.107-110
    • /
    • 2011
  • 커튼월의 단열성이 가장 취약한 패스닝 유닛 부분의 단열성을 향상시키기 위한 연구이다. 멀리온과 연결부위가 최소화 되도록 고안하여 제작하였고, 중간에 방진고무 및 실리콘으로 단열층을 형성하여 그 성능을 평가하였다. 무단열에 비해 방진고무 단열은 2.6℃~4.0℃의 온도차를 보였으며, 실리콘 단열은 2.4℃의 온도차를 보였다. 따라서 패스닝 유닛에는 단열층이 필요하다고 판단된다.

  • PDF

고무 발포 배관 보온 단열재의 성능 기준 및 평가 (Performance Standards and Evaluation of Elastomeric Flexible Cellular Insulation)

  • 전현석;최현중;최경석;강재식;이승언;정광섭
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.614-617
    • /
    • 2009
  • Elastomeric Flexible Cellular Insulation is widely used in construction fields to prevent condensation and frozen pipes, reduce energy, and improve insulation. However, when Elastomeric Flexible Cellular Insulation has been installed in buildings in Korea, there was no standardization, which resulted in heat loss Therefore, insulation design standards need to be developed and from these standards, pipe insulation should be improved to increase its efficiency. This study estimates temperature and surface-emissivity according to the thickness of insulation to evaluate thermal performance.

  • PDF

WUFI 시뮬레이션 프로그램을 이용한 목조주택 벽체 레이어 구성에 따른 hygrothermal 성능 평가 (Evaluation of The Hygrothermal Performance by Wall Layer Component of Wooden Houses Using WUFI Simulation Program)

  • 강유진;김수민
    • Journal of the Korean Wood Science and Technology
    • /
    • 제44권1호
    • /
    • pp.75-84
    • /
    • 2016
  • 건물에너지 저감에 효과적으로 기여하는 건축 재료를 이용하는 목조주택을 기반으로 단열 성능이 향상되고 있다. 그러나 고단열 고기밀화로 인한 습기 제어가 어려워져 외벽의 결로 및 곰팡이 발생으로 인하여 성능이 저하될 수 있다. 이에 열 습기 시뮬레이션 프로그램을 이용하여 선정한 5가지 형태의 목조주택 외벽의 열 습기 성능, 결로 발생 및 곰팡이 성장 위험을 평가하였다. 목조주택은 농촌주택 표준설계도 '10과 '14, $2^{{\prime}{\prime}}{\times}6^{{\prime}{\prime}}$형, EIFS 그리고 목조형 패시브 하우스로 선정하였고, 각 벽체 레이어를 구성에 따라 벽 A, B, C, D, E로 구분하였다. 벽체의 열관류율은 각각 0.171, 0.172, 0.221, 0.150, $0.079W/m^2K$이다. 벽 A와 C의 OSB 절대함수량은 기준치 20%를 초과하는 값이 나타났고, 결로 평가를 통하여 단열재 내부 표면에서 겨울철에 결로가 발생할 수 있음을 확인하였다. 벽 D와 E는 외단열 벽체로 다른 벽체에 비하여 함수량 평가와 결로 평가에서 우수한 결과를 보여주었다. 그러나 곰팡이 성장 위험 평가에서 5가지 형태의 벽체 모두 곰팡이 성장 위험성이 있음을 확인하였다. 이에 따라 외벽의 열 습기 성능의 차이는 열적 성능에 의한 발생보다는 레이어 구성에 따른 차이가 발생하는 것으로 판단되었다. 모든 벽체는 비슷한 열적 성능을 가지고 있으나 레이어에 따라 동일한 조건에서의 적합성이 다르게 나타나는 것을 확인하였다.

기존 공동주택 붙박이장에서 겨울철 결로 방지를 위한 보조난방장치 운전 성능 평가 (Operation Performance Evaluation on Auxiliary Heating Device to Prevent Condensation adjacent to Built-in Furniture of Apartment Units in Winter)

  • 이채린;이현화;임재한;송승영
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.567-578
    • /
    • 2018
  • The purpose of this study was to evaluate condensation prevention for condensation vulnerable areas around built-in furniture of apartment buildings by applying auxiliary heating device. Recently, the condensation and mold problems of apartment buildings has been growing due to high insulation and high air-tightness performance for energy saving. Condensation at built-in furniture were generally found in winter at the of furniture's back panels, adjacent surfaces of wall, floor and ceiling. These problems are related to the weather conditions and indoor room conditions in winter. To solve these problems, auxiliary heating device was developed and could be installed. The aim of paper is to analyze the thermal environment around the built-in furniture which were applied and not applied auxiliary heating device in winter. In results, it was possible to increase the surface temperature of vulnerable areas around built-in furniture by applying auxiliary heating device, and to minimize condensation problems by using the minimum device.

동계 아파트 외표면 온도에 의한 단열성능 비교평가 (Comparative Performance Evaluation by Winter Apartment Temperature on the Outer Surface of the Insulation)

  • 박정훈;김봉주
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제17권4호
    • /
    • pp.91-100
    • /
    • 2013
  • 이 연구에서는 기존아파트 외벽체의 단열 성능저하 및 보수보강에 필요한 기초 자료를 만들기 위해서 아파트의 구조체 단열성능 측정분석과 함께 단열하자에 대한 기준수립 및 평가를 하고자 한다. 또한 아파트 건축물 구조체의 열교 및 결로발생 부분을 예측하고자 하였다. 한편 시공연도별 분석에 의하여 단열기준 및 시간 경과에 따른 단열성능 정도를 분석하기 위함이다.