• Title/Summary/Keyword: Insulation Strength

Search Result 636, Processing Time 0.027 seconds

A Study on the Strength Properties and the Temperature Hysteresis of Winter Concrete according to the difference of Curing Method in Mock-up Test (실물대시험에서의 양생방법 차이에 따른 한중콘크리트의 온도이력 및 강도특성에 관한 연구)

  • Won, Cheol;Han, Cheon-Goo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.4
    • /
    • pp.87-94
    • /
    • 2003
  • This study is to investigate the temperature hysteresis and development of compressive strength due to the curing conditions and to evaluate the optimum curing condition of test specimens showing the same development of strength to that of real structures in cold weather. The results of temperature curve with curing conditions in mock-up tests showed the trend of decrease plain concrete with insulation form, plain concrete with heating, concrete with accelerator for freeze protection, and control concrete in turn. The strength development of plain concrete of inside and outside of shelter showed the very slow strength gains due to early freezing, but that of concrete with accelerator for freeze protection showed the gradual increase of strength with time. From this, it is clear that accelerator for freeze protection has the effects of refusing the freezing temperature and accelerating the hardening under low temperature. Strength test results of small specimens embedded in members and located in insulation boxes at the site are similar to that of cores drilled from the members at the same ages, thus it is clear that these curing methods are effective for evaluating in-place concrete strength

Making the Insulation Mortar Mixed with Waste Paper and Sawdust (종이와 톱밥을 혼입한 단열 모르타르 재료 개발에 관한 연구)

  • Lee, Seung-Young;Son, Ki-Sang
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.3
    • /
    • pp.78-82
    • /
    • 2010
  • This study is to test insulation mortar mixed with wastepaper and sawdust to find out its insulation performance. Therefore, wastepaper and sawdust have been added to normal mortar. They are analyzed for the above purpose using compressive strength and insulation performance. It is found that the more wastepaper and sawdust will be mixed, the lower heat conductivity will be taken. Wastepaper and sawdust mixture will be more 2.0% then the insulation mortar quality can be compatible with the 3rd kind of the standard. Optimal mixture for insulation will be wast paper:sawdust=4:6. Cohesive test of materials showed that test material has stronger than stand are $0.10N/mm^2$. It is satisfactory the test result showed a range of $0.12{\sim}0.15N/mm^2$ from the test result. Optimal mixture of wastepaper and sawdust have been found out from the study comprehensively, exclusive of the proportion of wastepaper:sawdust = 8:2. It is thought that standard of length deformation; 0.5% is reasonable. This means that deformation of mortar itself can be considered. But it is also Shown that water mixture has also been sharply changed at first flow test. Therefore, it is thought that absorbed water content in the material gave considerable effect to variation rate.

Lightning Impulse Breakdown Characteristic of Dry-Air/Silicone Rubber Hybrid Insulation in Rod-Plane Electrode

  • Kwon, Jung-Hun;Seo, Cheong-Won;Kim, Yu-Min;Lim, Kee-Joe
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.1181-1187
    • /
    • 2015
  • Sulfur hexafluoride (SF6) gas is used widely in electric power equipment such as Gas Insulated Switchgear (GIS), Gas Insulation transmission Line (GIL), and Gas Circuit Breaker (GCB). But applications of SF6 should be restricted because SF6 gas is one of the greenhouse effect gases. To reduce use of SF6 gas, a study on eco-friendly alternative insulation medium is needed. In this paper, we investigated lightning impulse (LI) breakdown of dry-air which is attracting attention as an ecofriendly alternative gas and the LI breakdown of hybrid insulation combined with dry-air and solid insulation (Room-Temperature Vulcanizing Silicone Rubber-RTV SIR) and dry-air in inhomogeneous fields according to gap distance and pressure. The experiment results showed that the LI breakdown strength of hybrid insulation system was higher than that of dry-air insulation system. It was verified that the development of technology related to eco-friendly power apparatus compact such GIS, GCB and GIL can be used as basic research data.

Predicting the moment capacity of RC slabs with insulation materials exposed to fire by ANN

  • Erdem, Hakan
    • Structural Engineering and Mechanics
    • /
    • v.64 no.3
    • /
    • pp.339-346
    • /
    • 2017
  • Slabs prevent harmful effects of fire that may occur in any floor. However, it is necessary to protect the slabs from fire. Insulation materials may be appropriate to protect reinforced concrete (RC) slab from elevated temperature. In the present study, a model has been developed in artificial neural network (ANN) to predict the moment capacity ($M_r$) of RC slabs exposed to fire with insulation material. 672 data were obtained for ANN model through author's prepared program. Input layer in model consisted of seven input parameters; such as effective depth (d), ratio of d'/d, thermal conductivity coefficient ($k_{insulation}$), insulation materials thickness ($L_{insulation}$), reinforcement area ($A_{st}$), fire exposure time ($t_{\exp}$), and concrete compressive strength ($f_c$). The predicted $M_r$ by ANN was consistent with the obtained $M_r$ by author. It is proposed to ease computational complexity in determining $M_r$ using ANN. The effects of using insulation material on the moment capacity in RC slabs were also investigated. Insulating material with low thermal conductivity has been found to be more effective for durability to high temperature.

Dielectric Insulation Properties of Double Pancake Coil Type HTS Transformer (Double Pancake Coil형 고온초전도 변압기의 전기적 절연 특성)

  • 백승명;정종만;이현수;한철수;김상현
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.2
    • /
    • pp.151-156
    • /
    • 2003
  • High temperature superconductor can only be applied against an engineering specofication that has to be determined for each particular application form the design requirements for economic viability and for operation margins in service. However, in order to realize the HTS transformer, it is necessary to establish the high voltage insulation technique in cryogenic temperature. Therefore, the composite insulation of double pancake coil type transformer are described and AC breakdown voltage characteristics of liquid nitrogen(LN$_2$) under HTS pancake coil electrode made by Bi-2223/Ag are studied. The Breakdown of LN$_2$ is dominated electrode shape and distance. The influence of pressure on breakdown voltage is discussed with th different electrode. For the electrical insulation design of turn-to-turn insulation for the HTS transformer, we tested breakdown strength of insulation sheet under varying pressure. And we investigated surface flashover properties of LN$_2$ and complex conition of cryogenic gaseous nitrogen(CGN$_2$) obove a LN$_2$ surface. The surface voltage of GFRP was measured as a function of thickness and electrode distance in LN$_2$ and complex condition of CGN$_2$ above a LN$_2$ surface. this research presented information of electrical insulation design for double pancake coil(DPC) type HTS transformer.

The Character of Electron Ionization and Attachment Coefficients in Perfluoropropane(C3F8) Molecular Gas by the Boltzmann Equation (볼츠만 방정식에 의한 C3F8분자가스의 전리 및 부착 계수에 관한 연구)

  • Song, Byoung-Doo;Jeon, Byoung-Hoon;Ha, Sung-Chul
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.4
    • /
    • pp.375-380
    • /
    • 2005
  • CF₄ molecular gas is used in most of semiconductor manufacture processing and SF/sub 6/ molecular gas is widely used in industrial of insulation field. but both of gases have defect in global warming. C₃F/sub 8/ gas has large attachment cross-section more than these gases, moreover GWP, life-time and price of C₃F/sub 8/ gas is lower than them, therefor it is important to calculate transport coefficients of C₃F/sub 8/ gas like electron drift velocity, ionization coefficient, attachment coefficient, effective ionization coefficient and critical E/N. The aim of this study is to get these transport coefficients for imformation of the insulation strength and efficiency of etching process. In this paper, we calculated the electron drift velocity (W) in pure C₃F/sub 8/ molecular gas over the range of E/N=0.1∼250 Td at the temperature was 300 K and gas pressure was 1 Torr by the Boltzmann equation method. The results of this paper can be important data to present characteristic of gas for plasma etching and insulation, specially critical E/N is a data to evaluate insulation strength of a gas.

Field Application of Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather (이중버블시트를 이용한 단열양생공법의 한중콘크리트 현장적용)

  • Hong, Seak-Min;Baek, Dae-Hyun;Kim, Jong;Jeon, Chung-Kun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.57-60
    • /
    • 2008
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in slab concrete and mass concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 6 and 15℃ even in case outside temperature drops -9℃ below zero until the 2nd day from piling, and in the case of mass concrete, with the maximum temperature difference between the center and surface less than 4℃, crack occurrence index was close to 2 and no hydration heat crack occurred by internal constraint. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

Field Application of Insulation Curing Method for the Concrete applying Double Layer Bubble Sheets Subjected to Cold Weather (이중버블시트를 이용한 단열보온 양생공법의 한중콘크리트 현장적용)

  • Hong, Seak-Min;Son, Ho-Jung;Oh, Chi-Hyun;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.05a
    • /
    • pp.83-85
    • /
    • 2011
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that concrete was protected from early freezing by remaining between 7℃ and 3℃ even in case outside temperature drops -7℃ below zero until the 3d day from piling. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF

Field Application of Insulation Curing Method with Double Bubble Sheets Subject to Cold Weather (이중버블시트를 이용한 단열양생공법의 한중콘크리트 현장적용)

  • Hong, Seak-Min;Lee, Il-Sun;Baek, Dae-Hyun;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.05b
    • /
    • pp.25-28
    • /
    • 2009
  • This study investigated the results of insulation heat curing method using double layer bubble sheet in slab concrete in cold weather environment. First of all, when double bubble sheets are applied, it was shown that slab concrete was protected from early freezing by remaining between 5 and $l0^{\circ}C$ even in case outside temperature drops $-11^{\circ}C$ below zero until the 4nd day from piling. The insulation heat preservation curing method using the double bubble sheet applied in this field prevented early freezing owing to stable curing temperature management, deterring concrete strength development delay at low temperature, and obtained the needed strength. Also, it was proven that the method is highly effective and economic for cold weather concrete quality maintenance through curing cost reduction like construction period shortening and labor cost reduction, etc by reducing the process of temporary equipment installation and disassembling.

  • PDF