• Title/Summary/Keyword: Insulation Performance of the Window

Search Result 126, Processing Time 0.027 seconds

The Evaluation of Thermal Performance of Double Vent Window System (Double Vent 창호 시스템의 단열성능평가)

  • Ryu, Seung-Ho;Park, Jin-Woo;Moon, Hyeun-Jun
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.557-560
    • /
    • 2008
  • Window system is an essential component for ventilation, lighting, and thermal environment in buildings. However, window system has the lowest insulation performance and may cause high energy consumptions, if it is not properly designed. Thus, performance of window systems play an important role in built environment. This study proposes a new window systems for balcony, which has double vents and analyses the thermal performance using an intergrated simulation method with Therm 6.1 and Widow 6.1. The result shows higher U-factor than conventional window systems. It is expected that the double vent window system can increase thermal performance and save energy in apartment houses.

  • PDF

Development of the Aircap Module Attached to the Window Through Rolling (롤링을 통한 창호부착형 에어캡 모듈 개발)

  • Her, Ji Un;Seo, Jang Hoo;Kim, Yong Seong;Lee, Heang Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.11
    • /
    • pp.559-569
    • /
    • 2017
  • Various studies examining how to conserve building energy have been conducted recently. From such studies it has been determined that insulation performance of an aircap is viable and therefore aircaps are used as material for improving insulation performance of windows. However, the aircap for improving insulation performance of a window is attached on the front, causing infringement of the prospect right. Therefore, the purpose of this study is to develop an aircap module attached to the window through rolling, conducting performance verification throughfull-scale testbed and verifying its effectiveness. Findings of this study are as follow : 1) The module suggested in this study enables setting of an area wherein the aircap is attached through rolling so that the aircap rolls up using Velcro tape, and an insulation bar is suggested to block the gap between the aircap and window glass. 2) When the aircap is applied to the window, consumption of lighting energy increased during summer and winter by 2.8%~16.4% and 0%~76.2% respectively in comparison to no aircap application, indicating that it is unsuitable for conserving lighting energy. 3) In terms of conserving cooling and heating energy, an advantageous or effective aircap attachment method is the method whereby an aircap is attached to the front surface of a window. However, the method whereby an aircap is attached to a part of a window and where no aircap is attached increases consumption of cooling and heating energy during summer and winter by 6.0%~35.7% and 2.7%~41.6% respectively in comparison to the method wherein an aircap is attached to the front surface of a window. 4) In consideration of conserving cooling, heating and lighting energy, the attachment of an aircap to the front surface of window is the most appropriate method, and it is appropriate to attach the aircap at a position that is 1,500 mm or higher from the floor to secure the prospect right and minimize energy loss.

Study on the Evaluation of Regional Building Energy Efficiency Rating According to the Insulation Performance of Double Skin Window in Apartment Houses Expanded Balcony (발코니 확장형 공동주택의 이중외피 창호 열성능에 따른 지역별 건축물에너지 효율등급 평가)

  • Jang, Cheol-Yong;Ahn, Byung-Lip;Kim, Chi-Hoon;Hong, Won-Hwa
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.5
    • /
    • pp.32-37
    • /
    • 2010
  • In order to handle the crisis about energy-environment problem, it is necessary to develop the future-oriented and innovative energy technology in architecture area. So the development of new technology for energy saving and alternative energy use has been spurred in this area. Double skin window system, which is an active covering to respond to the exterior change of the environment, is the skill that can reduce the indoor cooling and heating load and the environmental architecture can be realized. This study works out U-value of windows using the window-simulation program with the development and study of the double skin. In addition, the effect of the double skin insulation on the efficiency rating has been analyzed, applying to the certification system of the building energy efficiency rating which has implemented.

An Experimental Study on the Sound Insulation Performance of Korean Traditional Windows by Using a Scale Model House (축소모형주택을 이용한 전통창호의 차음성능에 관한 실험적 연구)

  • Shin, Hoon;Jang, Gil-Soo;Song, Min-Jeong
    • Journal of the Korean housing association
    • /
    • v.17 no.5
    • /
    • pp.47-54
    • /
    • 2006
  • This study aims to evaluate the sound insulation performance of Korean traditional paper(Hanji) windows as a material of environmental friendly building. Six types of traditional windows with 4 types of traditional window positions, were installed in l/2.5 scale model house. And then according to KS F 2235, comparative sound level differences between outdoor and indoor were measured. The main results are as follows; 1) TL(Transmission Loss) of Korean traditional paper windows, which cover one eighth of total balcony window, are ranged from 15 to 19 dB(A) in the living room and from 8 to 11 dB(A) in the balcony space. 2) TL of Korean traditional paper windows, which cover one fourth of total balcony window, are ranged from 10 to 19 dB(A) in the living room and from 8 to 10 dB(A) in the balcony space. 3) TL of Korean traditional windows with one side-one layer paper is ranged from 10 to 21 dB(A) and two side-one layer paper is 15 to 23 dB(A) and two side-two layer paper is 19 to 23 dB(A) respectively.

Variations of the Sound Insulation Performance of the Windows for the Sound Source Angle in the Field Test (현장실험에서 음원의 입사각도에 따른 창의 차음성능 변화)

  • Kim, Sun-Woo;Kim, Ki-Yong;Lee, Ok-Kyun;Park, Hyeon-Ku;Song, Hyuk
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1180-1186
    • /
    • 1999
  • The aim of this study is to investigate the sound insulation performance of windows according to the sound source in the field test. For this purpose, an experiment was performed by KSF 2235(method for field measurements of sound insulation of windows and doors). Based on this code, the sound insulation performance fo the windows was measured for different incident angles of the sound and the effect of incident angle was obtained and discussed. Finally, it was found that the sound insulation performance of the windows was affected by the incident angle of sound source, and the sound insulation rating scale was different for the same window. The main factor changing insulation rating scale is considered to be the sound transmission through the carck of the folding part between the two pieces of wndows. Therefore, when evaluating the sound insulation performance of the windows for the field test, first of all the place of the sound source should be identified and generalized.

  • PDF

An Experimental Study on the Effect of Hanji Windows on Indoor Air Temperature and Humidity Control (한지창호의 실내 온.습도 조절효과에 관한 실험적 연구)

  • Jang Gil-Soo;Park Sa-Keun;Song Min-Jeong;Shin Hoon
    • Journal of the Korean housing association
    • /
    • v.17 no.2
    • /
    • pp.125-134
    • /
    • 2006
  • The tightness of windows have devoted to the improvement of thermal insulation and energy saving in buildings. But it is known that this tightness causes some side effects such as low ventilation, low capacity to humidity and temperature control and these are not profitable for inhabitants. To act on these side effects, Korean traditional windows which are composed of Han-Ji(Koreand traditional paper) and Chang-Sal(Korean traditional wooden frame) have been studied to get a reasonable solutions for these problems. In this study, to compare the thermal and humidity control performance of current window(12 mm pair) and Korean traditional windows, frames which are made of existing window and Korean traditional windows are adapted to scale model house and then humidity and temperature of in and out of scale model house are measured and analysed. The results of this study are followings ; 1) When Korean traditional window charges 20cm(1/8 of total window area) from total window area, Han-Ji window has higher thermal insulation than that of existing window in daytime. There is the most big thermal difference when double faced with double-ply Han-Ji window is placed to mock-up house. In night-time, the temperature difference is very small so this means that Korean traditional window is good to cover direct sunlight in daytime and reduce the temperature of balcony. One faced with one-ply han-Ji window has the best humidity penetration performance among three type of Korean traditional windows. 2) When Korean window area enlarged to 40cm(1/4 of total window area), the function of 40cm width Han-Ji window is higher than that of 20cm's. This means that enlargement of Han-Ji window cover direct sunlight more and is more efficient in humidity penetration.

Thermal Performance Evaluation of Junction Thermal Bridge according to Installation Position of Window

  • Lee, Soo-Man;Kim, Dong-Yun;Ahn, Jung-Hyuk;Eom, Jae-Yong;Shin, U-Cheul
    • KIEAE Journal
    • /
    • v.17 no.3
    • /
    • pp.15-21
    • /
    • 2017
  • Purpose: "Building energy design standard" is used to limit the thermal transmittance of building in Korea. However, it only covers the insulation standard for each appropriate elements of a building, not the thermal performance of Junction thermal bridge of windows and doors installed in wall. Therefore in this study, we have evaluated the thermal performance of Junction thermal bridge depending on installation method and position of windows and provide it as design data. Method: We analyzed heat transfer of 4-Track sliding window and tilt & turn triple glazed window that are placed in the first class category on window energy efficiency rating using Window 7.4 and Therm 7.4. Result : First, linear thermal transmittance of 4-Track sliding window differs by 2.2 times or more depending of installation method and location. It is higher than the linear thermal transmittance, 0.01W/mK, proposed by Passivhaus. Second, linear thermal transmittance of Tilt & turn triple glazed window differs by 7.7 times or more depending of installation method and location. The average linear thermal transmittance was less than 0.01W /mK when windows were installed on the internal wall insulation by the fixed hardware attachment method. Third, the thermal losses of a window caused by a junction thermal bridge are inversely proportional to the window area and converge gradually as the area increased.

Thermal Performance Evaluation of Movable Insulation System in Apartments (공동주택 발코니창에 설치된 가동단열 시스템의 열성능 평가)

  • Yoon, Jong-Ho;Kim, Byoung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.28-35
    • /
    • 2008
  • The aim of this study was to analysis the Heating/cooling performance of movable insulation system built in apartments. The process of this study is as follows: 1) Test-cells of movable insulation are designed through the investigation of previous paper and work. The type of the movable insulation used in test-cell is low emissivity(5%) insulation, measured for heating season and the thermal effects are analyzed. 2) The simulation program(Design Builder) was used in energy performance analysis. the reference model of simulation was made up to analysis energy performance on movable insulation system. 3) Selected reference model(Floors:15, Area of Unit:115.5$m^2$) for heating/cooling energy analysis, Energy performance simulation with various variants, such as slate angle of movable insulation(5$^{\circ}$, 30$^{\circ}$, 50$^{\circ}$) and position of movable insulation. Consequently, When movable insulation system is equipped with balcony window of Apartment, Annual heating energy of reference model was cut down at the average of 5.4kWh/$m^2$ or 4.6% of heating/cooling energy.

An experimental study for the evaluation of airborne sound insulation performance of the small window (소형 창문의 차음 성능 평가에 관한 실험적 고찰)

  • Choi, Dool;Moon, Soon-Sung;Goo, Hee-Mo;Kim, Hang;Park, Hyeon Ku
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.1-1
    • /
    • 2014
  • Side scuttle in the shipboard windows is used in a smaller size in order to prevent damage to the glass. This shipboard windows should have high sound insulation performance (More than $R_w$ 53 dB) according to norsok standards. However, side scuttle having a small size and high sound insulation material is difficult to measure exact result without a suitable filler wall. In this study, the test was conducted according to the number of changes in the small window. As a result, before starting the test should be conducted to the selection of the suitable filler wall or secure a specimen area.

  • PDF

Investigation of the required performance to develop a performance-based indicator for balcony window systems in apartment houses (공동주택 발코니 창호의 성능기반지표 개발을 위한 요구성능 조사)

  • Moon, Hyeun-Jun;Ryu, Seung-Ho;Yang, Gi-Young
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.102-107
    • /
    • 2009
  • Window system is an essential component for lighting, ventilation and thermal environment in buildings. Moreover, as balcony extension in apartment houses become legalized, the performance requirements of window systems in balcony space are getting complicated. However, at this moment, five properties of the windows are used to represent the performance aspects of the system, including wind resistance, air tightness, water tightness, sound insulation, thermal resistance. And such single properties are not capable to express the performance of a space with the window systems in terms of performance concept. A performance analysis with wholistic approach is required to see the effect of the window system in built environment. Thus, performance-based approach should be established, which will be able to evaluate the goal/function and comfort of occupants/owners. As the first step to develop the performance indicator for the window systme for balcony space, this study conducts a survey to find the required performance aspects. A complete set of performance-based indicators will be developed with verification methods in the later stage of research.

  • PDF