• 제목/요약/키워드: Insulation Oil

검색결과 258건 처리시간 0.038초

Analysis of DC insulation and properties of epoxy/ceramic composites with nanosized ZnO/TiO2 fillers

  • Kwon, Jung-Hun;Kim, Yu-Min;Kang, Seong-Hwa;Kim, Pyung-Jung;Jung, Jong-Hoon;Lim, Kee-Joe
    • Journal of Ceramic Processing Research
    • /
    • 제13권spc2호
    • /
    • pp.332-335
    • /
    • 2012
  • A molded transformer is maintenance-free, which makes it unnecessary to replace the insulating material, like in an oil-filled transformer, because the epoxy, which is a molded insulating resin, does not suffer variations in its insulating performance for heat cycles over a long time, as compared to insulating oil. In spite of these advantages, a molded transformer may still be accessed by the user, which is not good in regards to reliability or noise compared to the oil transformers. In particular, a distrust exists regarding reliability due to the long-term insulating performance. These properties have been studied in regards to the improvement of epoxy composites and molded transformer insulation. There have nevertheless been insufficient investigations into the insulation properties of epoxy composites. In this study, it is a researching of the epoxy for insulating material. In order to prepare the specimens, a main resin, a hardener, an accelerator, and a nano/micro filler were used. Varying amounts of TiO2 and ZnO nano fillers were added to the epoxy mixture along with a fixed amount of micro silica. This paper presents the DC insulation breakdown test, thermal expansion coefficient, and thermal conductivity results for the manufactured specimens. From these results, it has been found that the insulating performance of nano/micro epoxy composites is improved as compared to plain molded transformer insulation, and that nano/micro epoxy composites contribute to the reliability and compactness of molded transformers.

유중 방전에 의한 초음파 측정용 광섬유 센서 특성 및 측정 데이터 분석 (Characteristics and Signal Analysis of Fiber-optic Sensor for Detecting Ultrasonic Waves Generated by Discharge in Insulation Oil)

  • 이상훈;송현직;이광식;김달우
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권10호
    • /
    • pp.481-486
    • /
    • 2003
  • It is well known that a discharge in oil is the source of various physical phenomena. Ultrasonic-wave detection is a useful method to the diagnosis of the transformer-insulation condition. Conventionally, ultrasonic waves are detected by Piezo-electric transducer, and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based on the needle-plane electrode system in oil and applied AC high voltage. Ultrasonic waves were detected and analyzed with wavelet transform.

변압기 열열화 모의 고장어 대한 유중가스 분포연구 (A study on gas dissolved distribution in oil for simulated transformer thermal faults)

  • 선종호;이상화;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1800-1802
    • /
    • 2003
  • This paper describes a study on gas dissolved distribution in oil for simulated transformer thermal faults. Experimental chamber was setup for simulation of transformer thermal faults or discharge in oil with or without insulation paper. The experimental results showed that dissolved gases in oil excluding the paper did not evolved upto $150^{\circ}C$. Hereafter the planned gas dissolved analysis will be continuously carried out for transformer fault conditions with or without insulation paper related to water absorption, arc and partial discharge.

  • PDF

공기 매질에 의한 압전 세라믹스의 분극효과 (Poling Effect on Piezoeletric Ceramics for Air Medium)

  • 김용혁
    • 한국전기전자재료학회논문지
    • /
    • 제23권6호
    • /
    • pp.464-470
    • /
    • 2010
  • A new method for the poling of piezoelectric ceramics with an air insulation medium in stead of silicon oil is described. A similar variation of electromechanical coupling coefficient $K_t$, for an air medium is observed in comparison to that of the material poled by the conventional poling method using a silicon oil medium. Different poling parameters such as dielectric constant $\varepsilon^T$ and frequency deviation ${\Delta}f$ are studied as well as the influence on the aging effect. The required poling factors to achieve the optimal piezoelectric characteristics are electric field, 2 kV/mm, temperature $100^{\circ}C$, and poling time 30 Min. From this result electric field 3 kV/mm atmosphere airs there being will be able to use with the polarization insulation medium about the piezoelectric material, confirmed.

Electrical Breakdown Strength of Insulation under Combined DC-AC Voltages

  • Grzybowski, S.
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제11권10호
    • /
    • pp.32-39
    • /
    • 1998
  • Electrical breakdown strength of paper-oil and polypropylene/film-oil insulation samples was measured under dc, ac and pulsating voltages. The latter was obtained by superimposing ac upon dc volate and provides an attractive method for a simultaneous testing and assessment of the state of insulation of the various parts of HV apparatus in service. The measurements were carried out over a wide range of the pulsation ratio defined as p=Eac/Edc. The results obtained under pulsating voltages follow colsely an experssion which relates the breakdown strength to the sum of arc tangent and arc cotangent function of the parameter p. The study was carried out using dry paper as well as paper containing various degrees of moisture. The presence of moisture showed a pronounced effect upon the breakdown strength which varied with the pulsation parameter p.

  • PDF

계면조건에 따른 에폭시와 고무 거시계면의 절연내력 (Dielectric Strength of Macro Interface between Epoxy and Rubber According to the Interface Condition)

  • 오용철;배덕권;김진사;김충혁
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권12호
    • /
    • pp.581-585
    • /
    • 2006
  • Macro interfaces between two different bulk materials which affect the stability of insulation system exist inevitably in the complex insulation system using in extra high voltage (EHV) electric devices. In this paper, Interface between epoxy and ethylene propylene diene terpolymer (EPDM) was selected as an interface in electrical insulation system and the AC dielectric strength of the interface was investigated. Air compress system was used to give pressure to the interface. Specimens were prepared in various ways to generate different surface conditions for each type of interface. Increasing interfacial pressure, decreasing surface roughness and spreading oil over surfaces improve the AC interfacial dielectric strength. Especially, the dielectric strength was saturated at certain interfacial pressure.

Tan Delta 측정을 이용한 유침 절연지의 열화특성 분석 (Analysis of Degradation Characteristics for Oil-Paper Insulation using Tan Delta Measurement)

  • 김정태;김우빈
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1518-1523
    • /
    • 2016
  • In this study, in order to understand the degradation characteristics of oil-paper insulation for power transformers and OF cables, tan delta was measured using cable model specimens with long-term accelerated thermal and electrical aging. In addition, to find out the degradation level due to the accelerated aging, tensile strengths of aged papers were measured. As a result, tan ${\delta}$ showed the characteristics of slight decrease at the first stage and then increase with the aging time, which could be analyzed due to the evaporation of remaining moisture and the change of aging rate with time. Also, the trend of tensile strengths with aging temperature and time was appeared to be exponentially decreased and by use of these data equivalent calculated lifetimes and accelerated aging factors were derived for each aging temperatures. After then, tan ${\delta}$ was analyzed with the equivalent operating years. For all different aging temperatures, the aged data were very well fit to the equivalent operating years and it is shown that tan ${\delta}$ was increased with the decrease of tensile strength.

Study on Influences and Elimination of Test Temperature on PDC Characteristic Spectroscopy of Oil-Paper Insulation System

  • Liu, Xiao;Liao, Ruijin;Lv, Yandong;Liu, Jiefeng;Gao, Jun;Hao, Jian
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1107-1113
    • /
    • 2015
  • Test temperature is an important factor affecting the measurement results of dielectric response of field power transformers. In order to better apply the polarization and depolarization current (PDC) to the condition monitoring of oil-paper insulation system in power transformers, the influences and elimination method of test temperature on PDC characteristic spectroscopy (PDC-CS) were investigated. Firstly, the experimental winding sample was measured by PDC method at different test temperatures, then the PDC-CS was obtained from the measurement results and its changing rules were discussed, which show that the PDC-CS appears a horizontal mobility with the rise of temperature. Based on the rules, the “time temperature shift technique” was introduced to eliminate the influence of test temperature. It is shown that the PDC-CS at different test temperatures can be converted to the same reference temperature coincident with each other.

풍력발전기용 밀폐형 변압기의 식물성 절연유에 대한 열적특성 연구 (Thermal Analysis of Vegetable Insulation Oil for Hermetically Sealed Wind Turbine Transformer)

  • 이성원;이준엽;김준수;우재희;김동해
    • 대한기계학회논문집B
    • /
    • 제36권1호
    • /
    • pp.97-102
    • /
    • 2012
  • 변압기 외부에 방열핀을 설치한 밀폐형 오일변압기는 절연유의 온도상승으로 인해 부피가 팽창할 경우 방열핀의 내부 부피가 확장되어 압력상승을 방지한다. 본 연구에서는 생분해도가 높아 환경친화적 이고, 인화점 및 발화점이 높아 화재의 위험도가 낮은 식물성 절연유를 이용하여 당사 풍력발전기에 적용할 밀폐형 오일변압기를 개발하였다. 열 유동 전산수치해석 기법을 이용하여 식물성 절연유 냉각성능을 광유 및 실리콘유와 비교 분석 하였으며, 밀폐형 오일변압기의 개발을 위하여 변압기 중신부의 열적 안전성을 확보하고 절연유의 온도변화에 따른 내부 압력변화에 대응이 가능한 팽창형 방열핀을 개발하였다. 추가로 온도상승시험을 통하여 수치해석 결과와 시험 결과를 비교 분석 하였으며, 식물성 절연유를 사용한 밀폐형 오일 변압기의 설계 고려사항을 도출하였다.

전기용량형 센서를 이용한 변압기 절연유 열화진단용 예방진단기법 개발 (Development of Preventive Diagnosis Techniques for Transformer Oil by Capacitive Sensor)

  • 김주한;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2061_2062
    • /
    • 2009
  • Within serviced period of time in transformer, thermal stress is the most influential parameter affecting the aging behavior of an insulation system. The thermal stress on the insulation system may occur from operation in a high temperature environment due to Joule's heat at winding coils. This paper describes a development of capacitive sensor and preventive diagnosis techniques for electrical insulating oil, widely used for power and distribution transformer. To survey the dielectric properties of the virgin and used mineral insulating oil, we utilized the highly precise measuring system of KRISS. And the results were used to determine the design factors of the sensor. To evaluate diagnosis by the sensor, we performed accelerated aging test about insulating oils. The condition of aged specimens were investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor.

  • PDF