용해로의 공정상 온도상승 및 과전류에 따른 케이블의 절연저항 특성 (Characteristics of Insulation Resistance of Cable according to Temperature Rise and Over-Current for Process of the Melting Furnace)

  • 고봉석;김두현;김성철
    • 한국안전학회지
    • /
    • 제39권2호
    • /
    • pp.22-27
    • /
    • 2024
  • The purpose of this study is to explore the trend in insulation resistance values according to temperature and overcurrent by conducting an investigation on the actual condition and experiments on the electrical wiring during the melting furnace process. In addition, the Arrhenius equation is used to determine whether temperatures in the furnace operating process can be applied to the actual field. In the investigation of the actual condition, the insulation resistance started to decrease seven years after replacement, even though cables in oil pump A were replaced in 2010. Both the experimental and theoretical values of the insulation resistance obtained using the Arrhenius equation decreased with an increase in temperature. Errors in insulation resistance (MΩ) values between tests and the Arrhenius equation ranged from ±2 to ±10, demonstrating a high similarity. Results revealed that when the insulation resistance cannot be measured in a manufacturing workplace (quarterly analysis), it can be estimated by partially applying the Arrhenius equation.

Recovery Voltage Measurements of Oil-immersed Transformer

  • Li, Ming-Hua;Dong, Ming;Qu, Yan-Ming;Yan, Zhang
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권5호
    • /
    • pp.230-234
    • /
    • 2006
  • One of the methods currently being investigated as a possible non-intrusive diagnostic tool for condition monitoring of power transformer and cable is the recovery voltage measurement, which will be improving the ability to detect the content of water concentration and the ageing process in the insulation system and may thus be an indicator of insulation quality and its ageing status. The polarization phenomenon was studied using RVM with oil-paper samples. In order to interpret its mechanism, the Extended Debye model was introduced. With different circuit parameters, various simulation results were gotten. Furthermore, with the test samples of different ageing condition, measurements are accomplished in the lab. On the basis of this experiment as well as theoretical analysis, correlations between polarizations and ageing were analyzed.

절연유-절연지에서 이중 임피던스에 의해 부분방전측정 (Partial Discharge Measurement of Oil-Paper Insulation by Dual Measuring Impeadance)

  • 김광화;류희석;선종호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1778-1780
    • /
    • 1996
  • In this paper, we describe the partial discharge measurement with measuring impedance to have two wide frequency band transformers(filters) in the oil-paper and air insulation. The measuring impedance consists of high and low limiting frequency transformers. This measuring impedance could be measured the partial discharge current wave. We have the results that the amplitude partial discharge pulse ratio of low limiting frequency tranformer to high limiting frequency one is varied in the condition(in oil-paper insulation and air) to generate partial discharge.

  • PDF

주상변압기 열적 특성 향상을 위한 복합절연 시스템 적용 (The Study on Application of Hybrid Insulation System for Thermally Upgraded Distribution pole Transformers)

  • 이병성;송일근;이재봉;김동명;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1896-1898
    • /
    • 2002
  • In this paper, to developing thermally and mechanically upgraded ones, we dismounted pole transformers used in the fields for over 13 years and conducted aged oil analysis. Also, when the cellulose and aramid papers in test cell were aging with oil at $130^{\circ}C$ for 3000 hours, with the testing period cellulose paper deteriorated more rapidly than the others. For example dielectric strength and dissipation factor of papers deteriorated with aging time. For evaluation of thermal aging characteristics, a mineral oil-immersed transformer was constructed with hybrid insulation system comprised of aramid paper and cellulose insulation. A Hybrid system has economic advantages. Cellulose materials are confined to cooler regions of the transformer winding. And aramid papers are served to insulate contact parts of hot conductors.

  • PDF

식물성절연유를 사용한 친환경 주상변압기의 절연 특성 연구 (Study on Dielectric Characteristics of the Environmental-friendly Pole Transformer using Vegetable Oil)

  • 곽동순;최재형;민치현;박태수;김상현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.921-922
    • /
    • 2007
  • In recent years, environmental concerns have been raised on the use of poorly biodegradable fluids in electrical apparatus in regions where spills from leaks and equipment failure could contaminate the surroundings. For development of the environmental-friendly pole transformer using vegetable oil, we discussed the insulation construction of the transformer and the dielectric characteristics of the Nomex insulation paper in vegetable oil. Based on the experimental data, the insulation of the transformer is designed.

  • PDF

The Investigation on Thermal Aging Characteristics of Oil-Paper Insulation in Bushing

  • Liao, Rui-jin;Hu, En-de;Yang, Li-jun;Xu, Zuo-ming
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권3호
    • /
    • pp.1114-1123
    • /
    • 2015
  • Bushing is the key link to connect outer and inner insulating systems and also the essential electric accessory in electric power system, especially in the high voltage engineering (AC 1000kV, DC 800kV). This paper presented the experimental research of thermal aging characteristic of oil-paper insulation used in bushing. A thermally accelerated aging experiment at 90℃ was performed. The bushing models containing five layers of paper were sealed into the aging vessels and further aged for 250 days. Then several important parameters associated with the aging were observed and evaluated. The results showed that the degree of polymerization (DP) of papers gradually decreased. The DP values of outermost layer and middle layer fit well into the second-order kinematic model and first-order kinematic model, respectively. Less deterioration speed of the inter-layer paper than outer layer was confirmed by the variation of DP. Hydrolysis was considered as the main cause to this phenomenon. In addition, the logarithm of the furfural concentrations in insulation oil was found to have good linear relationship with DP of papers. Interestingly, when the aging time is about 250 days and DP is 419, the aging process reaches an inflection point at which the DP approaches the leveling off degree of polymerization (LODP) value. Both tanδ and acid number of oils increased, while surface and volume resistivity of papers decreased. The obtained results demonstrated that thermal aging and moisture absorbed in papers brought great influence to the degradation of insulating paper, leading to rapid decrease of DP and increase of the tanδ. Thus, the bushing should be avoided from damp and real-time monitoring to the variation of tanδ and DP values of paper is an effective way to evaluate the insulation status of bushing.

Toughened 에폭시와 실리콘고무 계면의 교류 절연파괴 현상에 관한 연구 (Study on the AC Interfacial Breakdown Properties in the Interface between toughened Epoxy and Silicone Rubber)

  • 박우현;이기식
    • 한국전기전자재료학회논문지
    • /
    • 제15권12호
    • /
    • pp.1079-1084
    • /
    • 2002
  • Because complex insulation method is used in EHV(extra high voltage) insulation systems, macro Interfaces between two different bulk materials which affect the stability of insulation system exist inevitably. Interface between toughened epoxy and silicone rubber was selected as a interface in EHV insulation systems and tested AC interfacial breakdown properties with variation of many conditions to influence on electrical Properties, such as interfacial pressure, roughness and oil. Specimen was designed to reduce the effect of charge transport from electrode in the process of breakdown and to have the tangential electrical potential with the direction of the interface between epoxy and silicone rubber by using FEM(finite elements method). It could control the interfacial pressure, roughness and viscosity of oil. From the result of this study, it was shown that the interfacial breakdown voltage is improved by increasing interfacial Pressure and oil. In particular, the dielectric strength saturates at certain interracial Pressure level. The decreasing ratio of the interfacial breakdown voltage in non-oiled specimen was increased by the temperature rising, while oiled specimen was not affected by temperature.

Investigation on Oil-paper Degradation Subjected to Partial Discharge Using Chaos Theory

  • Gao, Jun;Wang, Youyuan;Liao, Ruijin;Wang, Ke;Yuan, Lei;Zhang, Yiyi
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권5호
    • /
    • pp.1686-1693
    • /
    • 2014
  • In this paper, oil-paper samples composed of transformer windings were used to investigate the insulation degradation process subjected to partial discharge (PD), with artificial defects inside to simulate the PD induced insulation degradation. To determine appropriate test voltages, the breakdown time obtained through a group of accelerated electrical degradation tests under high voltages was firstly fitted by two-parameter Weibull model to acquire the average breakdown time, which was then applied to establish the inverse power law life model to choose advisable test voltages. During the electrical degradation process, PD signals were synchronously detected by an ultra-high frequency (UHF) sensor from inception to breakdown. For PD analysis, the whole degradation process was divided into ten stages, and chaos theory was introduced to analyze the variation of three chaotic parameters with the development of electrical degradation, namely the largest Lyapunov exponent, correlation dimension and Komogorov entropy of PD amplitude time series. It is shown that deterministic chaos of PD is confirmed during the oil-paper degradation process, and the obtained results provide a new effective tool for the diagnosis of degradation of oil-paper insulation subjected to PD.

유입식 변압기의 열화시간에 따른 절연 열화특성 및 선형회귀법을 이용한 상관관계 분석 (Analysis for Insulating Degradation Characteristics with Aging Time for Oil-filled Transformers and/or Correlation between using Linear Regression Method)

  • 이승민
    • 전기학회논문지
    • /
    • 제59권4호
    • /
    • pp.693-699
    • /
    • 2010
  • General transformer's life is known as paper insulation' life. If a transformer is degraded by these aging factors, it is known that electrical, mechanical and chemical characteristics for transformer's oil-paper are changed. When the kraft paper is aged, the cellulose polymer chains break down into shorter lengths. It causes decrease in both tensile strength and degree of polymerization of paper insulation. The paper breakdown is accompanied by an increase in the content of furanic compounds within the dielectric liquid. In this paper it is aimed at analysis on correlation between aging characteristics for insulating diagnosis of thermally aged paper. For investigating the accelerated aging process of oil-paper samples accelerating aging cell was manufactured for estimating variation of paper insulation during 500 hours at $140^{\circ}C$ temperature. To derive the results, it was performed analysis such as tensile strength(TS), depolymerization(DP), dielectric strength(DS), relative permittivity, water content(WC) and furan compound(FC) for aged paper. Also for analyzing correlation between insulating degradation characteristics, we used linear regression method. As as results of linear regression analysis, there was a close correlation between TS and DP. WC, FC. But dielectric strength was a weak correlation with aging time.

광섬유 Mach-Zehnder 간섭계를 이용한 부분방전 초음파 검출특성 (Detecting Characteristics of Ultrasonics Generated by Partial Discharge in Insulating Oil Using the Optical Fiber Mach-Zehnder Interferometer)

  • 이상훈;심승환;이광식;김달우
    • 조명전기설비학회논문지
    • /
    • 제17권4호
    • /
    • pp.50-56
    • /
    • 2003
  • 본 논문에서는 유입변압기 진단을 목적으로 부분방전시 발생하는 여러 가지 물리적 화학적 현상중 초음파를 검출하기 위하여 광섬유 Mach-Zehnder 간섭계를 구성하였다. 구성된 광섬유 센서의 초음파 검출 평가 실험을 실시하고, 절연유 중에 배치한 침-평판전극에 교류 고전압을 인가하여 방전시 발생하는 초음파를 측정하고 퓨리에 변환 및 wavelet 변환을 이용한 데이터 분석 결과를 나타냈다.