• 제목/요약/키워드: Insulation Oil

검색결과 258건 처리시간 0.027초

유중방전 초음파 신호의 광학적 측정 및 wavelet 분석 (The optical measurement and wavelet analysis about ultrasonic signals by discharge in oil)

  • 이상훈;이현철;지승욱;김충년;송현직;이광식
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.298-303
    • /
    • 2004
  • It is well known that a discharge in oil is the source of various physical phenomena. Ultrasonic-wave detection is a useful method to the diagnosis of the transformer-insulation condition. Conventionally, ultrasonic waves are detected by Piezo-electric transducer, and we use optical method that has many advantages. In this paper, we constructed a Mach-Zehnder interferometer with optical fiber and investigated the principle of operation. Test arrangement is based rut the needle-plane electrode system in oil and applied AC high voltage Ultrasonic waves were detected and showed signal- analysis results with wavelet transform.

  • PDF

변압기 절연물의 열화에 따른 화화적 특성 (Chemical Characteristics of Transformer Insulations by the Thermal Aging)

  • 김재훈;이원영;이병성;이세현;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.1912-1914
    • /
    • 2005
  • The electrical, chemical and mechanical characteristics in transformer insulations are changed due to thermal stress. It is known that characteristics of transformer insulations is deteriorated such as decrease of dielectric strength, deterioration of dielectric constant and tensile strength of paper as transformer oil and paper are aged by thermal stress. Furthermore, chemical characteristics of them are deteriorated as like increment of moisture contents and dissolved by-products in oil, etc. In this paper we have been investigated chemical characteristics of transformer by accelerated thermal aging. For this working we have made experimental test cell and aged at a temperature up to $140^{\circ}C$ for 500 hours. The oil-paper insulation samples have been measured at intervals of 100 hours. For analysis we used Karl-Fisher titration method and high performance liquid chromatography (HPLC).

  • PDF

대두유 에스테르계 절연유의 합성과 분석 (Study on the synthesis and characterization of soybean based transformer oils)

  • 한동희;조한구;한세원;안명상;오대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.244-245
    • /
    • 2005
  • Electrical insulation is one of the most important parts in a high voltage apparatus. Traditionally mineral oils and synthetic esters have been widely used as dielectric coolants for power transformers. Recently, researchers are interested in the environmental friendly vegetable oil from environmental viewpoint. This paper reports on the synthesis and characterization of soybean based ester oils. Two different types of soybean based transformer oils, named as methyl ester and isopropyl ester were synthesized. The synthesis of these esters was achieved by transesterification reactions of soybean oil and alcohol in the presence of catalyst. The GC and NMR spectroscopic analysis of the esters have been performed. The thermal stability of the esters was determined by thermal gravimetric analysis(TGA).

  • PDF

파괴 및 비파괴진단 비교분석을 통한 케이블 열화특성평가 (Insulation Aging Characteristic Assessment on the Power cables with the Comparative Analysis Between Destructive and Nondestructive Diagnosis)

  • 이동영
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.104-108
    • /
    • 2009
  • 본 논문에서는 지중전력케이블을 대상으로 케이블의 절연열화특성 분석시험을 통해 케이블의 절연열화와 절연 진단결과 및 파괴강도와의 상관관계에 대한 실증연구를 수행하였다. 시험대상 선로의 제조결함 여부를 확인하기 위해 가교도분석, 핫오일테스트 등을 실시한 결과 제조결함은 없는 것으로 확인되었다. 진단대상 선로는 3상 모두 장기간 사용에 의해 열화가 많이 진전되었고, 특히 B상이 수트리 길이 및 화학구조결함 농도 면에서 가장 열화된 케이블인 것으로 판단되며, C상, A상의 순으로 열화정도가 다소 감소함을 확인하였다. 상기 결과는 진단시험 및 파괴 강도시험 결과와 일치하며, 따라서 열화시정수법을 이용한 진단장치가 열화상태가 심각한 케이블의 선별에 효과적인 진단법임을 확인하였다.

전동기 안전진단시스템 개발에 관한 연구 (Development of Intelligent safety diagnosis system of motor)

  • 강대규;이성근
    • 한국정보통신학회논문지
    • /
    • 제5권1호
    • /
    • pp.125-132
    • /
    • 2001
  • 본 논문에서는 선박에서 사용되고 있는 전동기의 절연저항 및 전류를 검출하여 안전진단을 행하는 안전진단시스템을 제안한다. 선박용 전동기는 상시 해풍·기름 등의 오염물질에 노출되어있기 때문에 절연저항의 감소, 과전류 등의 문제점이 야기될 수 있다. 이러한 문제는 선박의 안전항해에 막대한 영향을 주어 크나큰 인명과 재산상의 손실을 초래하게 된다. 제안된 시스템은 전동기의 절연저항 및 전류를 검침하여 이를 현장에서는 물론 제어실에서 확인 관리함으로서 사고가 발생하기 전에 전통기의 이상여부를 확인 할 수 있도록 한다. 제안된 방법의 타당성을 3상 유도전동기를 대상으로 확인한다.

  • PDF

지역별 건물에너지 효율에 관한 슈퍼윈도우 단열 성능 평가 연구 (A Study on the Insulation Performance of the Super window considering the evaluation of Building Energy Rating)

  • 장철용;안병립;김치훈;홍원화
    • 한국태양에너지학회 논문집
    • /
    • 제29권6호
    • /
    • pp.39-44
    • /
    • 2009
  • Entering in the time of high oil price, seriousness of an energy effect sector has given a huge impact and the importance of energy is growing. Especially, building energy occupying 24% of total demand of energy is expected to be possible to reduce energy demand more than other section. To reduce the building energy consumption, this study analyzes function and thermal performance of Super window by heat experimental apparatus. Super window is a 2-track low-e glazing window for high insulation efficiency. By applying the results of this experiment to building energy efficience rating tool, this study compares energy efficiency rates depending on a region.-Jeju, South, Central. And it shows how much does Super window reduce Building energy consumption.

선박용 전동기 진단장치 개발에 관한 연구 (Development of diagnosis system of motor for a ship.)

  • 강대규;김종윤;이성근;김윤식
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2001년도 춘계종합학술대회
    • /
    • pp.474-478
    • /
    • 2001
  • 본 논문에서는 선박에서 제공하는 전동기의 절연저항 및 전류를 상시 검출하여 진단을 행하는 진단 시스템을 제안한다. 선박공 전동기는 상시 해풍ㆍ기름 등의 오염물질에 노출되어있기 때문에 절연저항의 감소, 과전류 등의 문제점이 야기될 수 있다. 이러한 문제는 선박의 안전항해에 막대한 영향을 주어 크나큰 인명과 재산상의 손실을 초래하게된다. 제안된 진단장치는 전동기의 절연저항 및 전류를 연속적으로 감시할 뿐만 아니라 제어실에서도 데이터를 획득찬 수 있도록 설계한다. 제안된 방법의 타당성을 3상 유도전동기를 대상으로 확인한다.

  • PDF

절연물의 열화에 의한 AE신호와 변압기 외함의 AE노이즈 분포 (Distribution Characteristics of AE Signals in Insulation Deterioration and AE Noise in Cast Resin transformer)

  • 이상우;김인식;김이국;박원주;이광식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1865-1867
    • /
    • 2002
  • In this paper, frequency spectra of AE signals detected from respective the insulation deterioration were analysed to under ac high-voltage application using epoxy resin sample and insulation oil. Also, frequency spectra of AE signals generated from the load currents in the actual operating transformer of 500[kVA] under distribution system of 22.9[kVJ] were also analysed to distinguish the AE signals due to void discharges from the magnetic circuit noises in transformer. As the experimental results, we could distinguish the AE signals whether those signals were caused due to the void discharges or due to the magnetic circuit noises by analyzing the frequency spectrum of AE signals.

  • PDF

전기차단성 소재 기술 (Technology of Electrical Barrier Material)

  • 신은미
    • Elastomers and Composites
    • /
    • 제46권1호
    • /
    • pp.22-28
    • /
    • 2011
  • 전기의 흐름을 막는 절연재료는 다양한 전기/전력기구에서 도체에 흐르는 전기를 차단하면서 도체와 외부를 분리/지지하는데 사용한다. 절연재료에는 유리, 절연유, 가스, 종이, 고분자가 있으며 현재는 주로 고분자 절연재료가 전선에 사용된다. 최근 환경규제 및 친환경 소재로의 변화에 따라 고분자 절연재료에 사용되는 물질들도 친환경 화하고 있다.

변압기 절연유 중 PCBs, Co-PCBs 및 PCDD/PCDFs 오염수준 및 이성체 분포 (Contamination level and congener profiles of PCBs, Co-PCBs and PCDD/DFs in transformer insulation oil samples)

  • 김경수;김종국;신선경;김경심;송병주
    • 분석과학
    • /
    • 제19권3호
    • /
    • pp.263-271
    • /
    • 2006
  • 변압기 절연유 중 PCBs, Co-PCBs 및 PCDD/Fs를 GC/ECD와 HRGC/HRMS를 이용하여 정량한 결과 각각 N.D.~77.3 ppm, 0.0863~2.49 ppm과 N.D.~0.00241 ppm으로 검출되었다. WHO-TEQ 농도는 Co-PCBs가 23.3~600 pgTEQ/g, PCDD/Fs가 N.D.~128 pgTEQ/g (${\Sigma}Co$-PCBs+PCDD/Fs은 24.4~728 pgTEQ/g)으로 검출되어, 총 TEQ 농도 중 PCDD/Fs가 차지하는 비율은 12% 이하였으나, 변압기 절연유 중에 미량의 다이옥신이 존재하는 것으로 나타났다. 총 10개의 시료 중 4개의 시료에서 현행 기준인 2 ppm을 초과하였으며, 시료에 따라서 Aroclor 1242, 1248, 1254 및 1260이 단품 혹은 혼합품의 형태로 포함되어 있었다. 또한 Co-PCBs와 PCDD/Fs의 농도사이에 상관성이 나타났으나 (P<0.003), 변압기의 제작년도와 농도사이에 상관성은 나타나지 않았다. Co-PCBs 이성체 분포에 있어서 non-ortho 치환 이성체에 비해 mono-ortho 이성체가 높은 비율을 차지하였으며, PCB-118 이성체가 모든 시료에서 42% 이상으로 가장 높은 비율을 차지하였다. PCDD/Fs 이성체 분포에 있어서는 OCDD가 53% 이상으로 다른 이성체에 비해 높은 비율을 차지했다. 또한 일부 시료 중 Co-PCBs의 이성체패턴은 환경 대기시료 뿐만 아니라 PCBs 제품인 Aroclor와 유사한 패턴을 나타내어, 변압기 절연유가 대기 중 PCBs의 오염원 중 하나라는 것이 시사되었다.